• Title/Summary/Keyword: Signal Evaluation

Search Result 1,915, Processing Time 0.03 seconds

Artifacts Improvement by using the Echo Planar Imaging and Pre-Saturation Pulse Band techniques of Reduced Field-Of-View in Breast Magnetic Resonance Imaging Examination (유방 자기공명영상검사에서 감소된 영상영역의 에코평면영상기법과 사전포화기법 사용에 의한 인공물 개선)

  • Lee, Jaeheun;Kim, Hyunjin;Im, Inchul
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.307-314
    • /
    • 2015
  • This study was conducted in reducing the involuntary motion artifacts because of lungs and heart movements as well as the aliasing artifacts generated during the use of the reduced-FOV EPI technique while performing breast MRI. Performed on a total of 38 obesity female subjects who visited the clinic for pre-examination before surgery within the period from August 1 to November 30, 2014. The 3.0T MRI scanner equipped with a breast scanning coil. Qualitative and quantitative analyses were each used for the evaluation of the acquired images while an Paired T-test and Wilcoxon rank test were performed to check the statistical significance. The variation ratio rose by 15.69% with the additional application of a pre-saturation pulse in the lesion, by 13.72% near the lesion, and 20.63% in the fat and the contrast-to-noise ratio rose by 10.58% in and near the lesion and by 12.03% in the lesion and fat, respectively. there were increases of 22.05% and 21.42% at 0 and 1000 respectively in qulitative evaluation and growth of 16.10% in apparent diffusion coefficient. it showed a statistically significant result(p<0.05) in signal to noise ratio, contrast to noise ratio, diffusion slope coefficient and apparent diffusion coefficient. The involuntary movements artifacts that occur in the phase encoding direction and the aliasing artifacts are considered to be reduced to obtain the best image in the additional use of the pre-saturation pulse as DWI is acquired.

Characterization of Pv92, a Novel Merozoite Surface Protein of Plasmodium vivax

  • Lee, Seong-Kyun;Wang, Bo;Han, Jin-Hee;Nyunt, Myat Htut;Muh, Fauzi;Chootong, Patchanee;Ha, Kwon-Soo;Park, Won Sun;Hong, Seok-Ho;Park, Jeong-Hyun;Han, Eun-Taek
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.4
    • /
    • pp.385-391
    • /
    • 2016
  • The discovery and understanding of antigenic proteins are essential for development of a vaccine against malaria. In Plasmodium falciparum, Pf92 have been characterized as a merozoite surface protein, and this protein is expressed at the late schizont stage, but no study of Pv92, the orthologue of Pf92 in P. vivax, has been reported. Thus, the protein structure of Pv92 was analyzed, and the gene sequence was aligned with that of other Plasmodium spp. using bioinformatics tools. The recombinant Pv92 protein was expressed and purified using bacterial expression system and used for immunization of mice to gain the polyclonal antibody and for evaluation of antigenicity by protein array. Also, the antibody against Pv92 was used for subcellular analysis by immunofluorescence assay. The Pv92 protein has a signal peptide and a sexual stage s48/45 domain, and the cysteine residues at the N-terminal of Pv92 were completely conserved. The N-terminal of Pv92 was successfully expressed as soluble form using a bacterial expression system. The antibody raised against Pv92 recognized the parasites and completely merged with PvMSP1-19, indicating that Pv92 was localized on the merozoite surface. Evaluation of the human humoral immune response to Pv92 indicated moderate antigenicity, with 65% sensitivity and 95% specificity by protein array. Taken together, the merozoite surface localization and antigenicity of Pv92 implicate that it might be involved in attachment and invasion of a merozoite to a new host cell or immune evasion during invasion process.

The Effect of An Increase of Closed Quotient on Improvement of Voice Quality after Type I Thyroplasty in Patients with Unilateral Vocal Cord Paralysis (일측 성대마비 환자에서 성대내전술 후 성대접촉율의 증가가 음질 개선에 미치는 영향)

  • Kim, Han-Su;Choi, Seung-Hee;Lim, Jae-Yol;Choi, Hong-Shik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.1
    • /
    • pp.16-20
    • /
    • 2004
  • Purpose : To assess perceptual, acoustic and aerodynamic measure of voice quality in patients with unilateral vocal cord paralysis before and after type I thyroplasty. Methods : The clinical records of patients operated type I thyroplasty in the Departement of otorhinoalryngolgy, Yongdong Severance hospital from November 2001 to November 2003 were reviewed. All patients uderwent a vocal function evaluation including perceptual, acoustic and aerodynamic measures of voice preoperative and on $60^{th}$ postoperative day. The perceptual and acoustic measures were obtained from recording of patients' reading a 'Sanchak' passage. The perceptual evaluation was performed by 2 speech pathologist using a 4-point rating scale. Acoustic parameters(voice range profile low(RAL), voice range profile high(RAH), average fundamental frequency(AFX), closed quotient, harmonic to noise ratio, jitter and shimmer) were investigated by Lx speech studio. Mean flow rate(MFR), subglottic pressure(Psub) and intensity were measured using the Phonatory function analyzer. The maximum phonation time was also measured. The data were statistically analyzed. A paired t-test (p<0.1) was used to compare preoperative and postoperative results. And multiple regression test was used to find which parameter was most correlated to improvement of postoperative voice quality. Results : Among aerodynamic parameters, Psub $(88.11mmH_2O{\rightarrow}58.7mmH_2O)$, MPT(7.87sec${\rightarrow}$12.53sec), MFR (359.8ml/sec${\rightarrow}$161.06ml/sec) were statistically improved. AFx(205.5Hz${\rightarrow}$163.27Hz), AQx(23.9%${\rightarrow}$48.3%), RAL, RAH. Jotter and shimmer were improved. In multiple regression test, AFx and AQx was noted as the two meost correlated parameters to improvement of postoperative breathiness. But general grade of voice quality was more correlated to Psub and shimmer. Conclusion : Vocal fold medialization procedures effectively reduce glottic gap. Increasing of contact area of both vocal folds induced improvement in aerodynamic parameters and leaded stabilizing of vocal fold vibration. That effect results in improvement in acoustic parameters (shimmer, jitter, signal-to-noise ratio, voice range profile) and voice quality.

  • PDF

PSNR Evaluation of P Company DSA System between Server Display Monitor and Client Display Monitor (P사 DSA 시스템의 Server Display Monitor와 Client Display Monitor의 PSNR 평가)

  • Lee, Junhaeng
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.43-49
    • /
    • 2014
  • PACS is needed medical imaging with large-capacity storage device. Slower transmission degrades the performance of the PACS. Thus, the image read by the reading of the long-term stored image without compromising the quality of the video, which does not affect future readings in the range will be compressed and stored. Compression and video storage, and video transport Noise generated during storage and transmission of medical images and the resulting loss of information that occurs when the monitor output from many problems. The study estimates server display monitor and client display monitor of philips DSA system, and suggests that the evaluation and improvement about PSNR, process from server display signal obtaining to client display monitor. P company DSA is used in the test. Two monitors that are $1280{\times}1024$ pixel monitor of P company and 1536x2048 pixel monitor of Wide are used displaying angiography picture. MARO-view is taken in PACS program, and Visual $C^{++}$ is taken as accomplishing PSNR measurement program. As a result of experiment, no change in No 1, 3 of PSNR appear that there is no error in telephotograph and display. In terms of compressibility, low compressibility has small change of definition, and there was not remarkable drawback of compressibility which has little change in definition.

1V 1.6-GS/s 6-bit Flash ADC with Clock Calibration Circuit (클록 보정회로를 가진 1V 1.6-GS/s 6-bit Flash ADC)

  • Kim, Sang-Hun;Hong, Sang-Geun;Lee, Han-Yeol;Park, Won-Ki;Lee, Wang-Yong;Lee, Sung-Chul;Jang, Young-Chan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.9
    • /
    • pp.1847-1855
    • /
    • 2012
  • A 1V 1.6-GS/s 6-bit flash analog-to-digital converter (ADC) with a clock calibration circuit is proposed. A single track/hold circuit with a bootstrapped analog switch is used as an input stage with a supply voltage of 1V for the high speed operation. Two preamplifier-arrays and each comparator composed of two-stage are implemented for the reduction of analog noises and high speed operation. The clock calibration circuit in the proposed flash ADC improves the dynamic performance of the entire flash ADC by optimizing the duty cycle and phase of the clock. It adjusts the reset and evaluation time of the clock for the comparator by controlling the duty cycle of the clock. The proposed 1.6-GS/s 6-bit flash ADC is fabricated in a 1V 90nm 1-poly 9-metal CMOS process. The measured SNDR is 32.8 dB for a 800 MHz analog input signal. The measured DNL and INL are +0.38/-0.37 LSB, +0.64/-0.64 LSB, respectively. The power consumption and chip area are $800{\times}500{\mu}m2$ and 193.02mW.

A Novel Design of a Low Power Full Adder (새로운 저전력 전가산기 회로 설계)

  • Kang, Sung-Tae;Park, Seong-Hee;Cho, Kyoung-Rok;You, Young-Gap
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.3
    • /
    • pp.40-46
    • /
    • 2001
  • In this paper, a novel low power full adder circuit comprising only 10 transistors is proposed. The circuit is based on the six -transistor CMOS XOR circuit, which generates both XOR and XNOR signals and pass transistors. This adder circuit provides a good low power characteristics due to the smaller number of transistors and the elimination of short circuit current paths. Layouts have been carried out using a 0.65 ${\mu}m$ ASIC design rule for evaluation purposes. The physical design has been evaluated using HSPICE at 25MHz to 50MHz. The proposed circuit has been used to build 2bit and 8bit ripple carry adders, which are used for evaluation of power consumption, time delay and rise and fall time. The proposed circuit shows substantially improved power consumption characteristics, about 70% lower than transmission gate full adder (TFA), and 60% lower than a design using 14 transistors (TR14). Delay and signal rise and fall time are also far shorter than other conventional designs such as TFA and TR14.

  • PDF

Comparison of peripheral vascular compliance between normal and diabetic groups using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Nam, Ki-Chang;Kim, Su-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.15-20
    • /
    • 2007
  • Recently the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal(n=850) and diabetic(n=50) groups vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of the second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a rapresents vascular compliance. This study found out that when vascular compliance is decreased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy, $-1.09{\pm}0.14$ is statistically lower than the normal group, $-0.81{\pm}0.09$ (p<0.05). In conclusion, we suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

Total Degradation Performance Evaluation of the Time- and Frequency-Domain Clipping in OFDM Systems (OFDM 시스템에서 시간 및 주파수 영역 클리핑의 Total Degradation 성능평가)

  • Han, Chang-Sik;Seo, Man-Jung;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.17-22
    • /
    • 2007
  • OFDM (Orthogonal Frequency Division Multiplexing) is a special case of multicarrier transmission, where a single data stream is transmitted over a number of lower-rate subcarrier. One of the main reasons to use OFDM is to increase robustness against frequency-selective fading or narrowband interference. Unfortunately, an OFDM signal consists of a number of independently modulated subcarriers, which can give a large PAPR (Peak-to-Average Power Ratio) when added up coherently. In this paper, we investigate the performance of a simple PAPR reduction scheme, which requires no change of a receiver structure or no additional information transmission. The approach we employed is clipping in the time and frequency domains. The time-domain clipping is carried out with a predetermined clipping level while the frequency-domain clipping is done within EVM (Error Vector Magnitude). This approach is suboptimal with lower computational complexity compared to the optimal method. This evaluation is carried out on the OFDM system with an nonlinear amplifier. The simulation results demonstrated that the PAPR reduction algorithm is one of ways to reduce the effects of the nonlinear distortion of an HPA (High Power Amplifier).

A Convergence Study on effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb (하지동맥 전산화단층촬영 검사 시 생리식염수 희석을 통한 조영제 사용량 감소의 융복합 효용성 연구)

  • Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.431-437
    • /
    • 2015
  • This convergence study analyzed the effectiveness of contrast agent reduction by normal saline solution dilution in the computed tomography of arteries of lower limb. 48 patients of 125 cc contrast agent and 30 patients of the same amount divided at a ratio of 7:3 for the contrast agent and normal saline solution were studied. The average attenuation coefficient(HU) and signal to noise ratio(SNR) of abdominal aorta, femoral artery, popliteal artery and posterior tibial artery at each image were evaluated quantitatively and the four criteria in the five point scale was conducted qualitatively by two radiologists and four radiological technologists. In the quantitative evaluation, both HU and SNR had high average score before dilation but there were no statistical significance by independent t-test(p>0.05). In the qualitative evaluation, there were a little differences in the average scores between 4.86~4.77 of original contrast agent and 4.83~4.67 of dilated contrast agent but there were no statistical significance(p>0.05). In the computed tomography of arteries of lower limb, the dilated contrast agent doesn't influence image quality and reduces overall contrast agent and lowers iodine content per unit of molecular therefore will contribute to decrease side effect of contrast agent.

Evaluation of Field Application of Portable Near Infrared Reflectance Spectrometer (NIRS) for Quality Evaluation of Italian Ryegrass Silages (신속한 이탈리안라이그라스 사일리지의 품질평가를 위한 소형 근적외선분광기(NIRS)의 현장 적용성 평가)

  • Park, Hyung-Soo;Lee, Sang-Hoon;Kim, Jong-Gun;Choi, Ki-Choon;Seo, Sung;Kim, Won-Ho;Lee, Hyo-Won;Lim, Young-Chul
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.4
    • /
    • pp.415-422
    • /
    • 2011
  • This study evaluated the feasibility of using a portable near infrared reflectance spectrometer working in the 900~1,600 nm range for the measurement of quality-related parameters (moisture, pH, Acid detergent fiber (ADF), Neutral detergent fiber (NDF), Crude protein (CP), lactic acid) in intact silage. The calibration result for the Phazir (handheld, Polychromix) was compared with the result for the Spectrastar (Lab. based, Unity). A total of 67 Italian ryegrass silages were used to build calibration models using different spectral signal pre-treatments and the partial least squares regression (PLS) method. The good calibration statistics in two instruments was obtained for moisture content of Italian ryegrass silages with over $R^2$ = 0.95. The Phazir spectrometer was less accurate in measuring of ADF, NDF and CP contents. The Spectrastar instrument yielded greater precision for pH and lactic acid content; statistic values were over $R^2$ = 0.82 and the standard error of calibration (SEC) = 0.21% and 0.24%. Thus, the NIR measurement of forage quality in the field by portable NIR analyzers was shown not to be feasible, but additional investigations are required to discern the key instrumental and operational parameters that may influence the portable NIR measurement.