• Title/Summary/Keyword: Side-lobe

Search Result 308, Processing Time 0.034 seconds

Efficient Doppler Spectrum Estimation in Radar Systems (레이다 시스템에서의 효율적인 도플러 스펙트럼 추정)

  • Lee, Jonggil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.605-608
    • /
    • 2009
  • It is necessary to estimate the Doppler spectrum for each range cell for the extraction of useful information from the return echoes in radar systems used for the remote sending purpose. However, The conventional spectrum estimation method, FFT(Fast Fourier Transform), called the Doppler filter bank, causes the frequency resolution problem if the dwell time is relatively short. This short acquisition time also spreads the side lobe levels of return echoes further, resulting in difficulties for the discrimination of weak target signals included in relatively strong target echoes. Therefore, in this paper, the efficient Doppler spectrum estimation methods are compared and investigated through the parameter spectrum estimation in the time domain to overcome these problems.

  • PDF

Design of Optimized Two Baseline Waveguide Slot Array Antenna for Interferometric Radar Altimeter (기저선이 최적화된 간섭계 레이다 고도계용 도파관 슬롯 배열 안테나 설계)

  • Yoon, Nanae;Kim, Jihyung;Kim, Jinsu;Jang, Jonghun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.2
    • /
    • pp.135-143
    • /
    • 2022
  • In this paper, the compact waveguide slot array antenna for interferometric radar altimeter is proposed. The proposed antenna structure consist of corrugation structure which is applied between each channel to improve isolation, three-channel waveguide slot array antenna and feeder. In addition, to reduce the occurrence of phase ambiguity, the baseline spacing of the three-channel antenna is analyzed and the results are applied to the design. For compact design, reduced height and SMP connector structure are used and the dip brazing method which is the conjugation method after dipping to flux is used for the fabrication of the lightweight antenna. The measurement result of the proposed antenna shows less than 1.41 : 1 (VSWR) and 48.3 dBc (isolation). The antenna gain is higher than 20.2 dBi and the side lobe levels are lower than 18.8 dB (vertical plane) and 10.0 dB (horizontal plane).

A Study on Optimization of Structure for Hexagon Tile Sub-array Antenna System (Hexagon 타일 부배열 안테나 시스템 구조 최적화에 관한 연구)

  • Jung, Jinwoo;Pyo, Seongmin
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.129-132
    • /
    • 2022
  • In this paper, a technique for optimizing the sub-array system structure that can minimize the side lobe level of the phased-array antenna is proposed. Optimization of the proposed array antenna structure is to adjust the spacing between sub-arrays and sub-arrays by using a hexagonal array structure of one sub-array and a hexagonal sub-array for six hexagonal arrays, and thus the entire phased array antenna system of the radiation pattern was optimized. Compared to the 2-dimensional planar antenna system, the proposed technique maintains a gain of 24.3 dBi and a half-power beam-width of 8.46 degrees without change, and only reduces -3.4 dB and -6.5 dB in the x-axis and y-axis directions, respectively.

Analysis of the Radiation Pattern of Conformal Array Transducers (곡면 배열 트랜스듀서의 방사 특성 해석)

  • Kim, Hoe-Yong;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.7
    • /
    • pp.431-438
    • /
    • 2010
  • The radiation pattern of conformal transducers installed on a curved surface is likely to be complicated depending on the array pattern on the curved surface. In this research, the acoustic sources constituting a conformal transducer are arrayed in equi-angle, equi-interval, and geodesic dome forms, and the radiation pattern function of each of the array geometries has been derived, and therewith the radiation pattern has been analyzed for each array geometry. Based on the analysis result, we have determined the equi-interval array geometry that provides the widest beam width with the lowest side lobe level among the three array geometries. Results of the present work are expected to be utilized to the design of conformal transducer structures.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

A Case of Metastatic Oral Carcinoma from Rectal Cancer (직장암 유래 전이성 구강 암종의 진단예)

  • Shin, Keum-back;Kang, Kee-hyun;Chae, Gyu-sam
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.2
    • /
    • pp.171-179
    • /
    • 1999
  • The authors experienced a oral carcinoma involving the medial cortex of the right ramus of mandible and the left side of the maxilla which was metastasized from primary rectal adenocarcinoma based on the comprehensive evaluation of data obtained from (1) the past medical history of primary rectal adenocarcinoma, (2) the computerized tomographic views of the homogeneous mass on the anteromedial region of the right ramus of mandible destructing the medial cortex of the right ramus of mandible, and the irregular mass around the clivus spreading into the sphenoid sinus and destructing the left side of the maxilla ; the bone scanning of hot spots on the nasal region and the left side of maxilla ; the posteroanterior chest radiographic view of multiple nodular radiopacities on the lung, (3) the retrospective review of the sonographic view of a hypoechoic, well-demarcated, target-like mass with central hyperechoic focus on right lobe of liver in a Korean female of 49-year-old who complained the ptosis of left eyelid, the swelling on left zygomatic area, the left facial paralysis, the facial asymmetry and a round-shaped, elevated lesion with a hematoma on the mucosa covering the right ramus of mandible.

  • PDF

Design of Ground Clutter Prevention Fences for Radar Wind Profiler (연직바람 관측장비를 위한 지형 클러터 방지 펜스 설계)

  • WooJae Jung;JongChul Lee;JungIk Jeon;HyeongKi Lee
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.6
    • /
    • pp.241-249
    • /
    • 2022
  • This paper discusses the design of a ground clutter prevention fence for a radar wind profiler (RWP). The design point of the clutter fence is to improve the quality of the received signal by removing the non-weather clutter coming from the side. In this paper, a clutter prevention fence composed of a metallash mesh around the RWP is proposed, and the phase center of the antenna, the length, and height of the down fence, and the height and slop of the top fence through M&S are designed. The designed ground clutter prevention fence and 256 active phase array antennas were used as basic data. The effectiveness of the design was confirmed by a simulation. The side lobe in the ±90° direction was reduced by more than 30dB depending on the presence or absence of the designed ground clutter prevention fence. The fence was manufactured by 3D modeling, and the clutter shielding performance of approximately 20dB or more on the side of the antenna (±90°) was confirmed by applying it to the currently operated RWP.

Depth Extraction of Integral Imaging Using Correlation (상관관계를 활용한 집적 영상의 깊이 추출 방법)

  • Kim, Youngjun;Cho, Ki-Ok;Kim, Cheolsu;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.7
    • /
    • pp.1369-1375
    • /
    • 2016
  • In this paper, we present a depth extraction method of integral imaging using correlation between elemental images with phase only filter. Integral imaging is a passive three-dimensional (3D) imaging system records ray information of 3D objects through lenslet array by 2D image sensor, and displays 3D images by using the similar lenslet array. 2D images by lenslet array have different perspectives. These images are referred to as elemental images. Since the correlation can be calculated between elemental images, the depth information of 3D objects can be extracted. To obtain high correaltion between elemental images effectively, in this paper, we use phase only filter. Using this high correlation, the corresponding pixels between elemental images can be found so that depth information can be extracted by computational reconstruction technique. In this paper, to prove our method, we carry out optical experiment and calculate Peak Sidelobe Ratio (PSR) as a correlation metric.

A Case of Epithelioid Hemangioendothelioma Involving the Lung, Pleura and Liver (흉막과 간을 동시에 침범한 폐의 유상피 혈관내피종 1예)

  • Na, Joo Ock;Seo, Ki Hyun;Park, Ji Young;Kim, Jung Hoon;Kim, Tae Hoon;Choi, Jae Sung;Kim, Yong Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.179-184
    • /
    • 2005
  • Epithelioid hemangioendothelioma (EH) is a rare borderline malignant tumor which originating from vascular endothelial cells and occurs in many organs such as soft tissues, lung, liver and bone. But, pulmonary EH which simultaneously involves pleura and liver is very rare. In the present report, we describe an uncommon case of EH involving the lung, pleura and liver in a 26-year-old woman. Chest CT showed single nodule in right upper lobe with large amount of pleural effusion at ipsilateral side and abdominal CT multiple round low densities in liver. The EH was confirmed by microscopic analysis and immunohistochemical staining of CD34+ from open lung biopsy specimen.

Performance Analysis of the PCAE and PCAD in FO-CDMA Communication Network (FO-CDMA 통신망에서 PCAE와 PCAD 동작특성 분석)

  • Kang, Tae-Gu;Choi, Young-Wan
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.2 no.4
    • /
    • pp.5-16
    • /
    • 2003
  • We have analyzed the performance of optical matched filters in the fiber-optic code division multiple access (FO-CDMA) system based on optical parallel coupler access encoder (PCAE) and parallel coupler access decoder (PCAD) by experiment. In previous studies, the performance evaluation of the FO-CDMA system using SCAE and SCAD was not sufficiently accurate because they analyzed system performance only considering the first order signals. Since optical SCAE and SCAD intrinsically have high order signals of various patterns as the number of coupler increases, they change auto- and cross-correlation intensities. Thus, it is necessary to investigate properties of the PCAE and PCAD so that we may analyze the exact performance of system. In this paper, it is found that the peak to sidelobe ratio using the PCAE and PCAD increases as $\alpha$ (coupling coefficient) value increases. Also, we found that the proposed PCAE and PCAD are superior to SCAE and SCAD in performance improvement.

  • PDF