• Title/Summary/Keyword: Side-Load

Search Result 1,240, Processing Time 0.033 seconds

An Improvement Scheme of Direct Load Control Program for Electric Power Demand Management (합리적 전력수요관리를 위한 직접부하제어 사업의 개선 방안)

  • Kim, Kyu-Ho;Choi, Seung-Kil;Song, Kyung-Bin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.8
    • /
    • pp.81-86
    • /
    • 2007
  • This paper proposes the scheme to improve the current direct load control(DLC) program by inspecting the problems of the DLC program. In order to increase the number of the customers participating DLC program, a reduction of the base incentive and an increase of the direct load control incentive are suggested based on the interruption cost of electric power considering the characteristics of load types and the introduction of demand side bidding is recommended. Secondly, the standards of power system operations is required to control DLC program efficiently for the penalty, interruption times, the number of interrupting loads, notice time for the load interruption and the periods of the DLC program contract.

Effects of rock-support and inclined-layer conditions on load carrying behavior of piled rafts

  • Roh, Yanghoon;Kim, Garam;Kim, Incheol;Lee, Junhwan
    • Geomechanics and Engineering
    • /
    • v.18 no.4
    • /
    • pp.363-371
    • /
    • 2019
  • In this study, the load carrying behavior of piled rafts installed in inclined bearing rock layer was investigated for rock-mounted and -socketed conditions. It was found that settlements induced for an inclined bearing rock layer are larger than for a horizontal layer condition. The load capacity of piled rafts for the rock-mounted condition decreased as rock-layer inclination angle (${\theta}$) increased, while vice versa for the rock-socketed condition. The load capacities of raft and piles both decreased with increasing ${\theta}$ for the rock-mounted condition. When bearing rock layer was inclined, loads carried by uphill-side piles were greater than those by downhill-side piles. The values of differential settlements of rock-mounted and -socketed conditions were not significantly different whereas slightly higher for the rock-socketed condition. The values of load sharing ratio (${\alpha}_p$) and its variation with settlement were not markedly changed by the inclination of bedrock. It was shown that ${\alpha}_p$ for piled rafts installed in rock layer was not affected by ${\theta}$ whereas actual loads carried by raft and piles may vary depending on the pile installation and rock-layer inclination conditions.

A Study on the Design and Performance Test of Side Thruster (사이드 스러스터 설계 및 성능평가에 관한 연구)

  • Kim, Hyeong-Min;Kim, Lae-Sung;Cho, Sung-Hyun;Lyu, Sung-Ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.2
    • /
    • pp.1-6
    • /
    • 2017
  • In this paper, we present a study concerning the design of a 400 N class side thruster for small ships. The side thrusters used in Korea are imported from abroad. The performance and durability of the imported products employed in Korea are not adequate, therefore the side thrusters which will be suitable for Korean domestic needs to be re-designed. The strength calculation of the side thruster was performed by KS standard. Strength calculation and design were made to meet design requirements. Structural analysis and safety factor analysis were carried out to confirm the validity of strength calculations and design. After manufacturing the bevel gear, a back lash test was conducted. We also conducted a no-load test, a rated load, and an overload test for a performance test and a durability test of the design while satisfying the design conditions.

A Constant-Current and Constant-Voltage Control Method for Primary-Side Regulated Fly-Buck Converter (1차 측 제어 플라이벅 컨버터의 정전류 및 정전압 제어)

  • Younghoon Cho;Paul Jang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.30-38
    • /
    • 2023
  • In this paper, a constant current(CC) and constant voltage(CV) control method using a primary-side regulated(PSR) fly-buck converter is proposed. Because the primary-side structure of the fly-buck converter is the same as that of the synchronous buck converter, it always operates in continuous conduction mode(CCM). Therefore, in the proposed method, the load information on the secondary side can always be easily estimated by measuring the primary inductor current at the midpoint of the switch-on period. An accurate CC/CV control can be achieved through simple calculations based on this estimated information. Consequently, the proposed method is advantageous for optimizing the control performance of the PSR converter. The validity of the proposed control was verified using a 5 W prototype of a PSR fly-buck converter. The experimental results confirmed that the current reference of 500 mA was followed within the error range of 1.2%, and that the voltage reference of 12 V was followed within the error range of 1.8% despite the indirect control of the load current and output voltage from the primary side.

A study on the Reactive Power Compensation Effect Calculation by Determining an Accurate Voltage Collapse Point (정확한 전압붕괴점 결정에 의한 무효전력 보상 효과 산정 방법에 관한 연구)

  • Kim, Jung-Hoon;Ham, Jung-Pil;Lee, Byung-Ha;Won, Jong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.7-9
    • /
    • 2001
  • Many developing countries has been voltage unstable and the inter- change capability in Korea is limited by voltage instability. In analyzing voltage stability, load model has been considered as constant power, but actual loads vary as voltage changes. In order to incorporating voltage-dependent load model. we need the low-side of P-V curve that can not be obtained by general load flow algorithm. This paper proposes a modified GCF algorithm to obtain a full low-side of P-V curve and a accurate voltage assessment index considering load model. 5-bus sample system and 19-bus real power system are applied to simulate the proposed GCF. Also. the effect of reactive power compensation is illustrated in same systems.

  • PDF

An Assessment of Derailment Safety of Railway Vehicle depending on Curve Rail Condition (곡선부 선로 조건에 따른 차량의 탈선안전도평가)

  • Yoo, Hee-Sang;Park, Kwang-Soo;Lee, Hi-Sung
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.953-958
    • /
    • 2007
  • To assess the derailment safety of the Samaeul Train, We developed a fleet analysis model and carried out sensitivity analysis of the variables related to derailment factors with ADAMS/Rail computing analysis method. Depending on the variation of the running speed in curve section, derailment coefficient and wheel load reduction rate are high at right side wheels in slow running speed section and low at left side wheel in high running speed. According to decreasing the radius of curve, derailment coefficient and wheel load decreasing rate are increased. Derailment coefficient is proportional to transition curve length and wheel load decreasing rate is constant. Cant value rising causes wheel load deduction rate rising.

  • PDF

Building AHU Load Control Algorithm based on Demand Response (DR 기반의 건물 공조 부하관리 알고리즘)

  • Kim, Jeong-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1225-1228
    • /
    • 2011
  • This paper presents an advanced energy saving algorithm in building. It is important to aggregate a various demand side resource which is controllable on demand response environment. Previous demand side algorithm for building is restricted on peak power. In this paper, we suggest duty cycle algorithm for AHU on demand response to reduce the quantity of building power consumption. The test results show that the proposed algorithm is very effective.

An New Load Control Algorithms based on Power Consumption (전력사용량 기반의 새로운 부하제어 알고리즘)

  • Kim, Jeong-Uk
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.9
    • /
    • pp.1658-1662
    • /
    • 2010
  • This paper presents an advanced energy saving algorithm in building. It is important to aggregate a various demand side resource which is surely controllable at the peak power time to reduce the energy cost. Previous demand side algorithm appropriate for building is based on peak power. In this paper, we develop the new energy saving algorithm to reduce the quantity of power consumption. The simulation results show that the proposed tem is very effective.

Power Consumption Management Algorithm Based on OpenADR (OpenADR 기반의 전력사용량 관리 알고리즘)

  • Kim, Jeong-Uk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.991-994
    • /
    • 2016
  • This paper presents a load management method based on OpenADR of smart grid. Previous demand side algorithm is restricted on reducing peak power. But, in this paper we suggest a method of performing the energy-saving control according to the power price utilizing building automatic control system installed on the customer side in the case of hourly differential pricing signal is transmitted to the open automated demand response system. And, we showed the integrated demand management software for 3 buildings.