• Title/Summary/Keyword: Side step

Search Result 575, Processing Time 0.036 seconds

A Study On High Power Factor Sine Pulse Type Power Supply For Atmospheric Pressure Plasma Cleaning System with 3-Phase PFC Boost Converter (3상 PFC 부스트 컨버터를 채용한 상압플라즈마 세정기용 고역률 정형파 펄스 출력형 전원장치에 관한 연구)

  • Han, Hee-Min;Kim, Min-Young;Seo, Kwang-Duk;Kim, Joohn-Sheok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.1
    • /
    • pp.72-81
    • /
    • 2009
  • This paper presents quasi-resonant type high power factor ac power supply for atmospheric pressure plasma cleaning system adopting three phase PFC boost converter and it's control method. The presented ac power supply consists of single phase H-bridge inverter, step-up transformer for generating high voltage and three phase PFC boost converter for high power factor on source utility. Unlikely to the traditional LC resonant converter, the propose one has an inductor inside only. A single resonant takes place through the inside inductor and the capacitor from the plasma load modeled into two series capacitor and one resistance. The quasi-resonant can be achieved by cutting the switching signal when the load current decrease to zero. To obtain power control ability, the propose converter controlled by two control schemes. One is the changing output pulse period scheme in the manner of PFM(Pulse Frequency Modulation) control. On the other, to provide more higher power to load, the DC rail voltage is directly controlled by the 3-phase PFC boost converter. The significant merits of the proposed converter are the uniform power providing capability for high quality plasma generation and low reactive power in AC and DC side. The proposed work is verified through digital simulation and experimental implementation.

Design of High Average Power Pulse Transformer for 30-MW Klystron of L-Band Linac Application (산업용 선형가속기 시스템 적용을 위한 30-MW 클라이스트론용 고 평균전력 펄스 트랜스포머의 설계)

  • Jang, S.D.;Son, Y.G.;Gwon, S.J.;Oh, J.S.;Bae, Y.S.;Lee, H.G.;Moon, S.I.;Kim, S.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1550-1551
    • /
    • 2006
  • An L-band linear accelerator system for e-beam sterilization is under design for bio-technology application. The klystron-modulator system as RF microwave source has an important role as major components to offer the system reliability for long time steady state operation. A PFN line type pulse generator with a peak power of 71.5-MW, $7{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present a system overview and initial design results of the high power pulse transformer.

  • PDF

Wafer-Level Fabrication of a Two-Axis Micromirror Driven by the Vertical Comb Drive (웨이퍼 레벨 공정이 가능한 2축 수직 콤 구동 방식 마이크로미러)

  • Kim, Min-Soo;Yoo, Byung-Wook;Jin, Joo-Young;Jeon, Jin-A;Park, Il-Heung;Park, Jae-Hyoung;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.148-149
    • /
    • 2007
  • We present the design and fabrication prcoess of a two-axis tilting micromirror device driven by the electrostatic vertical comb actuator. A high aspect-ratio comb actuator is fabricated by multiple DRIE process in order to achieve large scan angle. The proposed fabrication process enables a mirror to be fabricated on the wafer-scale. By bonding a double-side polished (DSP) wafer and a silicon-on-insulator (SOI) wafer together, all actuators on the wafer are completely hidden under the reflectors. Nickel lines are embedded on a Pyrex wafer for the electrical access to numerous electrodes of mirrors. An anodic bonding step is implemented to contact electrical lines with ail electrodes on the wafer at a time. The mechanical angle of a fabricated mirror has been measured to be 1.9 degree and 1.6 degree, respectively, in the two orthogonal axes under driving voltages of 100 V. Also, a $8{\times}8$ array of micromirrors with high fill-factor of 70 % is fabricated by the same fabrication process.

  • PDF

An Efficient and Secure Query Processing on Valid XML Streams (유효한 XML 스트링에 대한 효율적이고 안전한 질의 처리)

  • Byun, Chang-Woo;An, Eun-Ju;Park, Seog
    • Journal of KIISE:Databases
    • /
    • v.36 no.3
    • /
    • pp.235-246
    • /
    • 2009
  • As demands intending to treat an access control on a client side that was conventionally controlled at a server are surged. it needs a way to treat query processing in effective and secure manners in an environment that has limited resources. Because the access control having been previously performed was only focused on safety, there was little effort to consider the access control in terms of efficiency. Researches about security including access control are started as the security issues are cropped up in a recent stream environment. This paper proposes a method for efficient and secure query processing of XML data streams like a PDA and a portable terminal at the client that is in limited resources. Specifically, this study suggests (1) an access control processing that possesses small overhead for attaining a secure result in a limited memory and (2) a way to enhance the performance, finding the parts being capable of optimizing in each processing step for offsetting the overhead caused by an addition of the access control processing. Superiority of the new method was analyzed by experiment.

Parameter Evaluation of High-Power Pulse Transformer for L-Band 30-MW Klystron (L-band 30-MW 클라이스트론용 고출력 펄스트랜스포머의 파라미터 평가)

  • Jang, S.D.;Son, Y.G.;Kwon, S.J.;Oh, J.S.;Kim, S.H.;Yang, H.R.;Moon, S.I.;Kwon, B.H.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1079-1081
    • /
    • 2007
  • An L-band Linear Accelerator System for E-beam sterilization is under construction for bio-technology application. The klystron-modulator system as an RF microwave source has an important role as major components to offer the system reliability for long time steady-state operations. A PFN line type pulse generator with a peak power of 71.5-MW, $7\;{\mu}s$, 285 pps is required to drive a high-power klystron. The high power pulse transformer has a function of transferring pulse energy from a pulsed power source to a high power load. The pulse transformer producing a pulse with a peak voltage of 275 kV is required to produce 30-MW peak and 60 kW average RF output power at the frequency of 1.3-GHz. We have designed the high power pulse transformer with 1:13 step-up ratio. The peak and average power capability is 71.5-MW (275 kV, 260 A at load side with $7\;{\mu}s$ pulse width) and 130 kW, respectively. In this paper, we present measurements and its analysis on the design parameters, and an initial test result as well as a design concept on the high-power pulse transformer.

  • PDF

A Planning for Agricultural.Rural Communities Theme Park in Yesan County (예산군 농업.농촌 테마공원 계획)

  • Lee, Gyeong-Jin;Song, Byeong-Hwa
    • Journal of Korean Society of Rural Planning
    • /
    • v.15 no.1
    • /
    • pp.89-99
    • /
    • 2009
  • I wish to establish Kwang-shi Han-woo agriculture theme park furtherance plan that take advantage of unique area resource of homebred cattle meat sale restaurant of the Chungchong-namdo Yesan County Kwang-Shi Ran-woo village. Improve regional income that develops Kwang-shi Ran-woo area that is made up a rest and experience space that escapes in sightseeing of Ran-woo meat putting first that is food, and contribute in economy activation by promotes City-Farm exchange, and is behind present, and is expected that contributes in farm village area activation that is stagnated Ran-woo specialization area of whole country scale. Kwang-shi Han-woo agriculture-farm village theme park plan is thought that active participation of thorough environmental protection and local resident is necessary condition as plan that take advantage of peculiar latency resource of area. In plan process, reflected various opinion of local resident representatives to space but there is a little insufficient page, and sees that also thorough environment analysis should be preceded. Hereafter, see that correction' repletion need a little through thorough grasping of latency resource that put together thorough natural environment investigation. in Yesan County with analysis at final design step. But, see that plan of theme park that take advantage of characteristic resource in farm village, especially situation of Ran-woo farmhouses that is suffering now difficulty as plan that do appropriateness of city in area activation and economical income guarantee side of farmhouse inhabitants.

Application of a Selective Emitter Structure for Ni/Cu Plating Metallization Crystalline Silicon Solar Cells (Selective Emitter 구조를 적용한 Ni/Cu Plating 전극 결정질 실리콘 태양전지)

  • Kim, Min-Jeong;Lee, Jae-Doo;Lee, Soo-Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.7
    • /
    • pp.575-579
    • /
    • 2010
  • The technologies of Ni/Cu plating contact is attributed to the reduced series resistance caused by a better contact conductivity of Ni with Si and the subsequent electroplating of Cu on Ni. The ability to pattern narrower grid lines for reduced light shading was combined with the lower resistance of a metal silicide contact and an improved conductivity of the plated deposit. This improves the FF (fill factor) as the series resistance is reduced. This is very much requried in the case of low concentrator solar cells in which the series resistance is one of the important and dominant parameter that affect the cell performance. A Selective emitter structure with highly dopeds regions underneath the metal contacts, is widely known to be one of the most promising high-efficiency solution in solar cell processing In this paper the formation of a selective emitter, and the nickel silicide seed layer at the front side metallization of silicon cells is considered. After generating the nickel seed layer the contacts were thickened by Cu LIP (light induced plating) and by the formation of a plated Ni/Cu two step metallization on front contacts. In fabricating a Ni/Cu plating metallization cell with a selective emitter structure it has been shown that the cell efficiency can be increased by at least 0.2%.

A Case Report of the Mesocaval Shunt in the Failed Splenorenal Shunt (선천성 문정맥의 기형으로 인한 문맥압항진증에 시행한 Shunt 의 1례 보고)

  • 정성규
    • Journal of Chest Surgery
    • /
    • v.5 no.2
    • /
    • pp.107-112
    • /
    • 1972
  • Recently we experienced a case of the portal hypertension, extrahepatlc origin in the National Medical Center, Seoul. The case was a male aged 19 who was undergone the elective splenorenal shunt with splenectomy 9 years ago and emergency ligation of the coronary vein because of recurred variceal rupture 6 years later and had recurring esophageal varices with bleeding this time.At the age of 10 he had been occasionally suffering from nasal bleeding and visited to our Pediatric department, when there was encountered for the first time the splenomegaly, esophageal varices in the lower third esophagus on the esophagogram, and stenosis and kinking of the portal vein with rich collateral circulation on the splenoportography without hepatic functional impairment.The elective splenorenal shunt with splenectomy was undergone under the diagnosis of portal hypertension due to congenital anomaly of the portal vein and postoperatlvely no troubles had been obtained until postoperative 1st attack of massive hematemesis due to esophagenl variceal rupture recurred about 6 years later which was confirmed by control esophagogram and it was resulted by stenosis of previous anastomotic site of the splenorenal shunt.Then emergency ligation of the coronary vein was only made for bleeding control and no episodes of hematemesis had been encountered thereafter until April 1972 about 3 years after the 2nd operation, when hematemesis recurred again. In this time, recurring esophageal varices were noted in the lower third esophagus on the control esophagogram and he was employed side to end mesocaval shunt as the final step of portal decompression,and following results were obtained. 1] No postoperatlve troubles as leg edema or pain: Postoperatively leg elevation and elastic bandage on the both legs were employed until discharge. 2] During operation the portal pressure was 300 mm $H_2O$ and immediately lowered to 170 mm $H_2O$ after shunt.

  • PDF

Evaluation of the Anti-inflammatory and Immunomodulatory Effects of BSASM Using in vitro Experiments (시험관내에서 천연물제제 BSASM의 항염증 및 면역억제 효능 평가)

  • Lee, Jong-Sung;Park, Yu-Mi;Park, Byung-Hwa;Jung, Kwang-Seon;Kim, Kuk-Hyun;Lee, Won-Hee;Park, Deok-Hoon
    • Korean Journal of Pharmacognosy
    • /
    • v.34 no.3 s.134
    • /
    • pp.228-232
    • /
    • 2003
  • For effective management of atopic dermatitis, it is important to introduce a therapeutic agent although having the fewest side effects, has the greatest anti- inflammatory effect. In the course of screening anti-inflammatory agents, we obtained BSASM composed of several plant extracts. This study was designed to investigate anti-inflammatory and immunomodulatory effects of BSASM. As a first step, $NF-{\kappa}B$ luciferase reporter assay was performed to know the involvement of BSASM in the production of proinflammatory cytokines because $NF-{\kappa}B$ element has been known to play a major role in expression of cytokine genes such as interleukin-8 (IL-8) or tumor necrosis $factor-{\alpha}\;(TNF-{\alpha})$. LPS (lipolysaccharide)-induced $NF-{\kappa}B$ activation was inhibited by BSASM. In addition, we found the fact that BSASM inhibits LPS-induced produced production of IL-8 and $TNF-{\alpha}$ proinflammatory cytokines, indicating BSASM has anti-inflammatory effect. In interleukin-2 (IL-2) luciferase reporter assay in Jurkat T cells, BSASM reduced PHA (Phytohemagglutinin)-induced IL-2 luciferase activity, suggesting the possibility that BSASM might also have an immunomodulatory function in T cell-mediated immune response. Based on these results, we suggest the possibility that BSASM can be introduced to improve symptom of immune-related skin diseases, namely, atopic dermatitis.

Development of a Static Prosthesis-Alignment Device Using a Force Plate and a Laser Light (힘측정판과 레이저 광을 이용한 정적 의족정렬장치의 개발)

  • 이기원;김기완;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.385-390
    • /
    • 2000
  • The alignment of the prosthetics is very important in an amputee's gait. In the present study. a static prosthesis-alignment device was developed. It consisted of a force plate with four load cells, a laser beam controlled by a step motor, and a control part programmed by PCBASIC. Using the static prosthesis-alignment device, we measured the distance between the load line and various joints of 24 normal volunteers in three standing postures. such as neutral, forward leaning, and backward leaning. Only neutral postures were evaluated on four trans-tibial amputees. The load line for the normal person's neutral position located anterior to the ankle, the knee, and the greater trochanter, but posterior to the shoulder joint. Forward and backward leaning of the normal person resulted in a significant anterior and posterior movements of the load line, respectively. The load line for the amputated side of the trans-tibial amputee also located anterior to the ankle, the extremity prostheses, providing a good relative locations of the load line with respect to various joints.

  • PDF