• Title/Summary/Keyword: Side step

Search Result 578, Processing Time 0.026 seconds

Electrochemical Migration Characteristics of Sn-3.0Ag-0.5Cu Solder Alloy in NaBr and NaF Solutions (NaBr 및 NaF 용액에 대한 Sn-3.0Ag-0.5Cu 솔더 합금의 Electrochemical Migration 특성)

  • Jung, Ja-Young;Jang, Eun-Jung;Yoo, Young-Ran;Lee, Shin-Bok;Kim, Young-Sik;Joo, Young-Chang;Chung, Tai-Joo;Lee, Kyu-Hwan;Park, Young-Bae
    • Journal of Welding and Joining
    • /
    • v.25 no.3
    • /
    • pp.57-63
    • /
    • 2007
  • Electrochemical migration characteristics of Pb-free solder alloys are quantitatively correlated with corrosion characteristics in harsh environment conditions. In-situ water drop test and corrosion resistance test for Sn-3.0Ag-0.5Cu solder alloys were carried out in NaBr and NaF solutions to obtain the electrochemical migration lifetime and pitting potential, respectively. Sn-3.0Ag-0.5Cu solder alloy shows similar ionization and electrochemical migration behavior with pure Sn because of Ag and Cu do not migrate due to the formation of resistant intermetallic compounds inside solder itself. Electrochemical migration lifetime in NaBr is longer than in NaF, which seems to be closely related to higher pitting potential in NaBr than NaF solution. Therefore, it was revealed that electrochemical migration lifetime of Sn-3.0Ag-0.5Cu solder alloys showed good correlation to the corrosion resistance, and also the initial ionization step at anode side is believed to be the rate-determining step during electrochemical migration of Pb-free solders in these environments.

The Eigenvalues and Their Relationships for the Rectangular Frame (4각형 골조의 고유치와 고유치 간의 관계)

  • Lee, Soo-Gon;Kim, Soon-Cheol;Song, Chang-Young;Song, Sang-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.3
    • /
    • pp.139-150
    • /
    • 2005
  • Finite element method is applied to the determinations of the two eigenvalues(the elastic critical load and the natural frequence of lateral vibrations) of single story-3 equal bay rectangular frame. The analysis parameters are taper parameter ${\alpha}$ for column, and beam span to column height ratio, ${\beta}$ and second moment area ratio of beam to column, ${\Upsilon}$. Support condition at the column base and sway condition at the column top are also considered in the stability analysis of frame. The changes in the coefficient of eigenvalue are represented by algebraic function of analysis parameter. The coefficients estimated by the proposed algebraic function show good agreement with those determined by finite element method, which suggest the design aid role of the proposed function. By increasing the column axial forces step by step, the corresponding frequencies are also determined, which makes one examine or confirm the relationship suggested by other studies.

Hydrogen production with high temperature solar heat thermochemical cycle using NiFe2O4/m-ZrO2 device (NiFe2O4/m-ZrO2 device를 이용한 고온 태양열 열화학 싸이클의 수소 생산)

  • Lee, Jin-Gyu;Shin, Il-Yoong;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.1
    • /
    • pp.107-114
    • /
    • 2011
  • Two-step thermochemical cycle using ferrite-oxide($Fe_3O_4$) device was investigated. The $H_2O$(g) was converted into $H_2$ in the first experiment which was performed using a dish type solar thermal system. However the experiment was lasted only for 2 cycles because the metal oxide device was sintered and broken down. Another problem was that the reaction was taken place mainly on a side of the metal oxide device. The $m-ZrO_2$, which was widely known as a material preventing sintering, was applied on the metal oxide device. The ferrite loading rate and the thickness of the metal oxide device were increased from 10.67wt% to 20wt% and from 10mm to 15mm, respectively. The chemical reactor having two inlets was designed in order to supply the reactants uniformly to the metal oxide device. The second-experiment was lasted for 5 cycles, which was for 6 hours. The total amount of the $H_2$ production was 861.30mL.

Study on the Improvement of the Convective Differencing Scheme for the High-Accuracy and Stable Resolution of the Numerical Solution (수치해의 정확성과 안정성이 보장되는 대류항 미분법 개선에 관한 연구)

  • 신종근;최영돈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.6
    • /
    • pp.1179-1194
    • /
    • 1992
  • QUICKER scheme has several attractive properties. However, under highly convective conditions, it produces overshoots and possibly some oscillations on each side of steps in the dependent variable when the flow is convected at an angle oblique to the grid line. Fortunately, it is possible to modify the QUICKER scheme using non-linear and linear functional relationship. Details of the development of polynomial upwinding scheme are given in this paper, where it is seen that this non-linear scheme has also third order accuracy. This polynomial upwinding scheme is used as the basis for the SHARPER and SMARTER schemes. Another revised scheme was developed by partial modification of QUICKER scheme using CDS and UPWIND schemes(QUICKUP). These revised schemes are tested at the well known bench mark flows, Two-Dimensional Pure Convection Flows in Oblique-Step, Lid Driven Cavity Flows and Buoyancy Driven Cavity Flows. For pure convection oblique step flow test problem, QUICKUP, SMARTER and SHARPER schemes remain absolutely monotonic without overshoot and oscillation. QUICKUP scheme is more accurate than any other scheme in their relative accuracy. In high Reynolds number Lid Driven Cavity Flow, SMARTER and SHARPER schemes retain lower computational cost than QUICKER and QUICKUP schemes, but computed velocity values in the revised schemes produced less predicted values than QUICKER scheme which is strongly effected by overshoot and undershoot values. Also, in Buoyancy Driven Cavity Flow, SMARTER, SHARPER and QUICKUP schemes give acceptable results.

A Study of Postural Sway and Dynamic Standing Balance with Low Back Pain (요통환자의 자세동요와 동적기립균형에 관한 연구)

  • Yang, Dae-Jung;Song, Tae-Ho;Lim, Ho-Yong;Ahn, Yeon-Jun;Park, Seung-Kyu;Kim, Yeong-Rok
    • Journal of Korean Physical Therapy Science
    • /
    • v.11 no.2
    • /
    • pp.18-26
    • /
    • 2004
  • The purpose of this study was to compare difference of the static and dynamic balance in normal subject and LBP subject and recognizes about postural sway. The subjects of this study included 30 normal subjects and 30 LBP subjects. By using Active balance system, the static balance was measured by unit path length, circumference area, weight bearing, stabilometry length, while the dynamic balance was measured by step evaluation. Statistically analyzed using independent t-test to search static balance and dynamic balance difference in two groups. Postural sway appeared greatly in patient group than normal group in analysis result of static balance and postural sway was big in patient group of when closed eye and normal group and patient group did show statistical significance in unit path length, circumference area. Weight support of normal group was shared equally in weight bearing rate, but weight support of patient group stewed less to pain side. Anterior step time and Task achieve time of dynamic balance were spent more in patient group than normal group. Desire to be used to useful information to lay treatment policy about set-up and action of when quantification result of valued postural balance treats low back pain patient by objective tool, in the fixture, more researches in postural estimation desire that is enforced abuzz.

  • PDF

Evaluation of Track irregularity due to Adjacent Excavation Work on Serviced Urban Transit (도시철도 인접굴착공사에 따른 운행선 궤도의 궤도틀림 분석)

  • Choi, Jung-Youl;Lee, Ho-hyun;Kang, You-Song;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.481-487
    • /
    • 2020
  • In this study, finite element analysis was performed to evaluate the track irregularity of the existing track system on urban transit according to the large-scale excavation work that is constructed adjacent to the serviced line. Based on the numerical analysis, the effect of track irregularity generated during the step-by-step construction process was analytically derived, and the stability in terms of track deformation was evaluated through comparison with related standards. As the results, in the case of track irregularity items evaluated based on the relative displacement difference at a certain distance, such as alignment and vertical irregularity, it occurred most clearly at the location where deformation of the existing structure begins, such as the end point of adjacent excavation work. On the other hand, the overall vertical and horizontal displacement of the track was the largest deformation at the center of the construction section. The vulnerable position of the deformed side of the existing structure due to adjacent excavation is analytically proven that the both of the end point section and the center of the construction can be a vulnerable position in terms of track irregularity.

Pulmonary Vessels Segmentation and Refinement On the Chest CT Images (흉부 CT 영상에서 폐 혈관 분할 및 정제)

  • Kim, Jung-Chul;Cho, Joon-Ho;Hwang, Hyung-Soo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.188-194
    • /
    • 2013
  • In this paper, we proposed a new method for pulmonary vessels image segmentation and refinement from pulmonary image. Proposed method consist of following five steps. First, threshold estimation is performed by polynomial regression analysis of histogram variation rate of the pulmonary image. Second, segmentation of pulmonary vessels object is performed by density-based segmentation method based on estimated threshold in first step. Third, 2D connected component labeling method is applied to segmented pulmonary vessels. The seed point of both side diaphragms is determined by eccentricity and size of component. Fourth step is diaphragm extraction by 3D region growing method at the determined seed point. Finally, noise cancelation of pulmonary vessels image is performed by 3D connected component labeling method. The experimental result is showed accurately pulmonary vessels image segmentation, the diaphragm extraction and the noise cancelation of the pulmonary vessels image.

A Study on the Semantic Web for Meta-Communication System (메타커뮤니케이션 시스템 구현을 위한 시맨틱 웹 연구)

  • Kwon Hyo-Jeong;Kim Chee-Yong
    • Journal of Digital Contents Society
    • /
    • v.6 no.4
    • /
    • pp.201-208
    • /
    • 2005
  • In high-technology digital age that change everyday fast, Web became most familiar and essential tool to public. Since creation of web, web began from the first step web that offer simple information and contents. and now, it have developed to step offer dynamic contents that various multimedia components are combined. In future, it will develop to the next generation, intelligence style Semantic Web that Meta Communication of meaning-base is possible. In this paper, we examine about concept and characteristic of Semantic web that is a point technology in next generation. Also, we studied about example and practical use in personalized contents side that is based on Semantic Meta-Communication system. Semantic web is value industry field that has infinite possibility and has necessary of a lot of studies and development yet. Therefore in digital age, we expect this paper will help for space construction of more mature communication.

  • PDF

Pilot Study for the Assessment of Physical Fitness among Male Workers in a TV Component Manufacturing Factory (일부 TV부품 제조업체 남자 근로자들의 체력평가 기초연구)

  • Choi, Gwang-Seo;Lee, Young-Ha;Kim, Sung-Hie;Woo, Kuck-Hyeun;Han, Gu-Wung;Kim, Doo-Hie
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.531-545
    • /
    • 1994
  • In a TV component manufacturing factory, 102 male workers aged $20{\sim}39$ years old were participated in testing for physical fitness. At the same time, worker's periodic health examination was done. Test battery for physical fitness include grip strength, trunk flexion, standing long jump, side step, single leg balance with eye close, push ups and Harvard step test. As a result of testing for physical fitness, synthetically, there is no difference between manufacturing workers and officers. By bioelectrical impedance test, it means a declining tendency to all 7 factors in the obese workers, and so, it is important for obese workers not only to promote physical fitness but also to promote health. Excluding grip strength and single leg balance with eye close, 5 fitness factors are negatively associated with degree of diastolic Blood pressure, but it is statistically not significant. And levels of sGOT & sGPT have no association with physical fitness factors.

  • PDF

Behaviors of Providers of Traditional Korean Medicine Therapy and Complementary and Alternative Medicine Therapy for the Treatment of Cancer Patients

  • Yu, Jun-Sang;Kim, Chun-Bae;Kim, Ki-Kyong;Lee, Ji-Eun;Kim, Min-Young
    • Journal of Pharmacopuncture
    • /
    • v.18 no.1
    • /
    • pp.27-35
    • /
    • 2015
  • Objectives: In Korea, cancer is one of the most important causes of death. Cancer patients have sought alternative methods, like complementary and alternative medicine (CAM) together with Western medicine, to treat cancer. Also, there are many kinds of providers of CAM therapy, including providers of Korean oriental medicine therapy. The purpose of this study is to identify the behaviors of Korean oriental medicine therapy and CAM therapy providers who treat cancer patients and to provide background knowledge for establishing a new policy with the management and quality control of CAM. Methods: Structured and well organized questionnaires were made, and 350 persons were surveyed concerning the providers of CAM or Korean oriental medicine. The questionnaires were collected and analyzed. Results: The questionnaires (182) were collected. The questionnaires identified a total of 73 known providers, such as medicinal professionals or other providers of CAM suppliers, 35.6% of whom had had experience with treating cancer patients (52.6% vs. 29.6%). The treatment methods were a little different: alternative therapy and nutritional therapy being preferred by medicinal professionals and mind body modulation therapy and alternative therapy being preferred by other CAM providers. Four patients (7.4%) experienced side effects, and 6 patients (12.5%) experienced legal problems. As the method for managing the therapy, CAM providers, medicinal professionals, and other CAM providers had different viewpoints. For example, some CAM providers stated that both legislation and an official education on CAM or a national examination were needed as a first step to establish the provider's qualifications and that as a second step, a license test was needed for quality control. To the contrary, medicinal professionals stated that a license test was needed before legislation. Conclusion: Adequate management and quality control of CAM providers is thought to involve both education and legislation.