• Title/Summary/Keyword: Side gap test

Search Result 38, Processing Time 0.024 seconds

Effect of Relative Position of Vane and Blade on Heat/Mass Transfer Characteristics on Stationary Turbine Blade Surface (베인과 블레이드 사이의 상대위치 변화에 따른 터빈 블레이드 표면에서의 열/물질전달 특성)

  • Rhee, Dong-Ho;Cho, Hyung Hee
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.140-150
    • /
    • 2004
  • In this study, the effect of relative position of the blade for the fixed vane has been investigated on blade surface heat transfer. The experiments were conducted in a low speed stationary annular cascade, and heat transfer of blade was examined for six positions within a pitch. Turbine test section has one stage composed of sixteen guide vanes and blades. The chord length of the tested blade is 150 mm and the mean tip clearance of the blade having flat tip is about $2.5\%$ of the blade chord. For the detailed mass transfer measurements on the blade surfaces, a naphthalene sublimation technique was used. The inlet flow Reynolds number is fixed to $1.5{\times}10^5$. Complex heat transfer characteristics are observed on the blade surface due to various flow characteristics, such as separation bubble, relaminarization, transition to turbulence and leakage vortices. The distributions of velocity and turbulence intensity change significantly with the relative position due to the blockage effect of the blade. This causes the variation of heat transfer patterns on the blade surface. The results show that the flow near the leading edge get highly disturbed and deflected toward the either side of the blade when the blade leading edge is positioned close to the trailing edge of the vane. Therefore, separation bubble disappears on the pressure side and overall heat transfer on the relaminarization region is increased. But, due to reduced tip gap flow at the upstream region, the effect of leakage flow on the upstream region of the blade surface is weakened. Thus, the heat transfer characteristics significantly change with the blade positions.

  • PDF

Analysis of Pole Ratio Effect of Magnetic Reducer (마그네틱 감속기의 극수비 영향 분석)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.277-283
    • /
    • 2020
  • In a concentric magnetic gear, which replaces the teeth of a mechanical gear with a permanent magnet, the polar ratio of the magnet that determines the reduction ratio affects the behavior of the magnetic gear dramatically. This study analyzed the density of transmission torque, the efficiency of torque considering the solid loss, and the torque quality, including the cogging characteristics using finite element analysis. When the pole number on the driving side was changed from two to five, it was confirmed that there was an optimal pole ratio, in which the transmission torque was maximized. Because eddy current generation density is proportional to the magnetic field, the transmission efficiency also shows a similar tendency to the transmission torque density, and the efficiency is more than 95% at a low gear ratio. The cogging characteristics due to the interaction of the permanent magnets with the limited number of poles are inversely proportional to the least common multiple between the number of magnets on the drive side and the number of modulator teeth. A test model was built for the transmission torque evaluation.

A CFD Study on the Combustion Pressure Oscillation by a Location of a Pressure Transducer inside Closed Vessel (밀폐용기 연소실험 시 센서위치에 따라 변화하는 압력 진동에 대한 수치적 연구)

  • Han, Doo-hee;Ahn, Gil-hwan;Ryu, Byung-tae;Sung, Hong-gye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.2
    • /
    • pp.66-73
    • /
    • 2018
  • A computational fluid dynamics simulation of pyrotechnic material combustion inside a cylindrical closed vessel was carried out using the Eulerian-Lagrangian method. The 5th order upwind WENO scheme and the improved delayed detached eddy turbulence model were implemented to capture shock waves. The flow structure was analyzed inside the cylindrical vessel with a pressure sensor installed at the side wall center. The analysis revealed that the pressure oscillated because of the shock wave vibration. Additionally, the simulation results with four different sensor tab depths implied that, inside the sensor tab, eddies were generated by the excessively large gap between the sensor diaphragm and the side wall. These eddies caused irregularity to the measured time-pressure curve, which is an undesirable characteristic.

A Case Report on Pregnancy-Related Carpal Tunnel Syndrome Worsened after Birth by Korean Medicine (임신 중 발생하여 출산 후 악화된 수근관 증후군 한방 치험 1례)

  • Im, Ji-Yeong;Han, Kuk-In;Lee, Eun-Hee;Lee, Ah-Yeong;Kim, Jong-Uk
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.65-76
    • /
    • 2015
  • Objectives : This study is to report the effect of Korean medical treatment on a patient suffered from carpal tunnel syndrome (CTS) occurred in pregnancy and worsened after birth. Methods : We treated the patient diagnosed as carpal tunnel syndrome by Korean medical treatment such as acupuncture, pharmacopuncture and herbal medicine at ⃝⃝Hospital of Korean Medicine from July 31th 2015 to August 6th 2015. And we evaluated changes of symptoms by Visual Analog Scale (VAS), Tinel sign, Phalen’s test, and Digital Infrared Thermographic Imaging (DITI). Results : 1. Through Korean medical treatment, postpartum carpal tunnel syndrome was significantly improved. VAS was decreased from 4 to 2, Phalen’s test was manifested from 10 seconds to 26 seconds and Tinel sign was changed from positive to negative. 2. We compared the gap of temperature between palm and forearm before and after Korean medical treatment through DITI. The temperature on the right side was changed from 0.74℃ to 1.01℃ and the left one from 0.63℃ to 1.01℃. Conclusions : This case report shows that Korean medical treatment is useful to treat pregnancy-related carpal tunnel syndrome worsened after birth.

A Multi-megawatt Long Pulse Ion Source of Neutral Beam Injector for the KSTAR

  • Chang, Doo-Hee;Seo, Chang-Seog;Jeong, Seung-Ho;Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Jin-Choon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.719-720
    • /
    • 2004
  • A multi-megawatt long pulse ion source (LPIS) of neutral beam injector was developed for the KSTAR. Beam extraction experiments of the LPIS were carried out at the neutral beam test stand (NBTS). Design requirements for the ion source were 120 kV/65 A deuterium beam and a 300 s pulse length. A maximum ion density of $9.1310^{11}$ $cm^{-3}$ was measured by using electric probes, and an optimum arc efficiency of 0.46 A/kW was estimated with ion saturation current of the probes, arc power, and total beam area. An arcing problem, caused by the structural defect of decelerating grid supporter, in the third gap was solved by the blocking of backstream ion particles, originated from the plasma in the neutralizer duct, through the unnecessary spaces on the side of grid supporter. A maximum drain power of 1.5 MW (i.e. 70 kV/21 A) with hydrogen was measured for a pulse duration of 0.5 s. Optimum beam perveance was ranged from 0.75 to 0.85. An improved design of accelerator for the effective control of beam particle trajectory should provide higher beam perveance.

  • PDF

Assessment of Congruence Angle according to the Central X-ray in the Merchant View of Patellofemoral Joint (슬대퇴관절의 Merchant View에서 중심 X선 위치에 따른 일치각 평가)

  • Kim, Hyun-jin;Joo, Yeong-chul;Choi, Jae-ho;Lim, Woo-taek
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.423-428
    • /
    • 2019
  • The Precise measurement of the knee's Congruence angle is required for diagnosis of patella dislocation. The purpose of this study is to consider the distortion diagram and usefulness about the test of the bilateral side and one side through the evaluating congruence angle from Merchant view of patellofemoral joint to central X-ray. We've evaluated the sulcus angle and Congruence angle following central X-ray's changes when we took Merchant view of patellofemoral joint aimed to right lower limb from human whole body phantom. The subject of the evaluation was classified as normal group and varus group, and the varus group has experimented with External rotation of legs as 15° and 30°. When normal groups result as 0, 7.5, 15 cm, it was measured as 17.25 ± 1.34°, 19.60 ± 1.41°, 20.55 ± 1.77° each. The gap between minimal and maximum angle was 3.3°, and the value was shown as getting bigger when it further away from the centeral X-ray. When Congruence angle in 15° varus group was 0, 7.5, 15 cm, it was each 16.45 ± 1.34°, 17.10 ± 0.99°, 17.80 ± 1.13°. And when Congruence angle in 30° varus group was 0, 7.5, 15 cm, it was measured each 18.35 ± 1.63°, 18.95 ± 1.06°, 19.60 ± 1.41°. The difference between minimum and maximum of angle in 15° varus group and 30° varus group was each 1.35° and 1.25°, the angles have shown as increasing the further away from the center. The patellofemoral joint showed that the congruence angle increases as the further away from Central X-ray, and also it is judged that is possible to change the congruence angle by a degree of varus knee. Thus, accurate measurement of the congruence angle is shown to advantage that methods for examining by split each side at two times than methods for examining both sides at a time. Therefore, it is expected to helpful on the diagnostic side of patella dislocation and subluxation.

A Study on Flow Induced Vibration of Cantilever Plate with Angle of Attack (받음각을 갖는 평판보의 유동 여기진동에 관한 연구)

  • 이기백;손창민;김봉환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.6
    • /
    • pp.1919-1932
    • /
    • 1991
  • Experimental studies are conducted to investigate the Flow-Induced Vibration mechanism for cantilever plate model with the angle of attack (.alpha.=10.deg., 20.deg., 30.deg.). Research is divided into two parts. First, the flow fields around two dimensional flat plate model are investigated using LDV system. Second, the vortex shedding frequency and response spectra of cantilever plate are obtained experimentally using gap sensor and hot wire anemometer. Finite element method program was used in order to predict the flow field and pressure field around thin flat plate. And some predicted results were compared with the experimental data. The aspect ration of test model is d/t=25 (d; width, t; thickness). From the measurement of the flow field it was found that in the case of small inclined (.alpha.=10.deg., 20.deg.) relatively, the separated boundary layer at sharp leading edge developed smoothly downstream. With increasing the angle of attack of the plate, stagnation region was appeared on the back side of the plate and separated boundary layer was extended downstream. These trends are a good agreement with the computational results. It was found by analysis of response spectra of cantilever plate that the influences of vortex shedding frequency were important at the large of attack (.alpha.=30.deg.), and two peak values appear in entire test model at 24Hz, 150Hz.

Effects of Korean Medicine Music Therapy on Anxiety, Anger Expression, and Concentration of Smart phone Addicted Adolescents (한방음악치료가 스마트폰 중독 청소년의 불안과 분노표현 및 주의집중력 향상에 미치는 영향)

  • Lee, Mi-hee;Lee, Seung-hyun
    • Journal of Korean Medical classics
    • /
    • v.30 no.3
    • /
    • pp.133-141
    • /
    • 2017
  • Objectives : As of 2013, South Korea ranked number one in the world in smartphone penetration rate with 67.6%. Unfortunately, with the rise of smart phone use, side effects such as fraud, loss of personal information, identity theft, formation and widening of a mobile information gap, and last, but not least, smart phone addiction, also increased. Methods : Seventh (7th)graders from a girls' junior high school in Seoul, the capital of South Korea, we reevaluated the Smart phone Addiction Proneness Scale (S-scale). Among the 9 students classified as high risk users, 5 were randomly selected for a study group, and the remaining 4 students, meanwhile, were designated as a control group. The study group received Korean medicine music therapy (KMMT) in a total of 8 sessions, each session lasting 50 minutes. Both pre- and post-interventions, the two groups completed the S-scale, Harris and Harris' concentration grid exercise, STAI, and STAXI-K. We analyzed the data by t-test and paired t-test using IBM SPSS Statistics. Results : KMMT had a significant influence on proneness to smart phone addiction (t=3.130, p=.035). KMMT had positive effects on concentration improvement (t=-2.935, p=.043), trait-anxiety symptoms improvement (t=2,992, p=.040), and anger-expression control (t=4.416, p=.012). Conclusions : KMMT had positive, improving effects on trait anxiety and anger expression, which in turn enhanced the improvement of concentration as well as the decrease of smart phone-addiction proneness.

FABRICATION OF Nb/Al SUPERCONDUCTING TUNNEL JUNCTION (Nb/Al SUPERCONDUCTING TUNNEL JUNCTION의 제작)

  • Cho, Sung-Ik;Park, Young-Sik;Park, Jang-Hyun;Lee, Yong-Ho;Lee, Sang-Kil;Kim, Sug-Whan;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.481-492
    • /
    • 2004
  • We report the successful fabrication and I-V curve superconductivity test results of the Nb/Al-based superconducting tunnel junctions. STJs with side-lengths of 20, 40, 60 and $80{\mu}m$ were fabricated by deposition of polycrystalline Nb/Al/AlOx/Al/Nb 5-layer thin films incorporated on a 3-inch Si wafer. STJ was designed by $Tanner^{TM}$ L-Edit 8.3 program, and fabricated in SQUID fabrication facility, KRISS. S-layer STJ thin-films were fabricated using UV photolithography, DC magnetron sputtering, Reactive ion etching, and CVD(Chemical Vapor Deposition) techniques. Superconducting state test for STJ was succeeded in 4K with liquid helium cooling system. Their performance indicators such ie energy gap, normal resistance, normal resistivity, dynamic resistance, dynamic resistivity, and quality factor were measured from I-V curve. Fabricated Nb/Al STJ shows $11\%$ higher FWHM energy resolution than genuine Nb STJ.

The Accuracy of Master Cast for Implant Prosthesis According to the Types of Impression Tray and Splinting Methods of Impression Copings (인상용 트레이의 종류와 인상용 코핑의 연결고정이 임플랜트 주모형의 정확성에 미치는 영향)

  • Lee, Jee-Hyuk;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.433-445
    • /
    • 2010
  • The aim of this study was to evaluate the fixation effect by connecting impression copings and to compare the three types of impression trays which were used in open tray impression technique. Experimental groups used 3 types of impression trays which are custom tray, plastic metal combination tray and polycarbonate stock tray. These three groups were subdivided into splinted and non-splinted impression copings group. The total number of experimental groups was six. 10 specimens were made for each group. We used 1-screw test, observing the specimen on which only one side abutment of reference framework was fixated with 20 Ncm. The gap between implant analogue and abutment of the other side was observed by stereo microscope. It was measured at 6 points in each specimen. Measuring value was selected when same result was revealed 3 times. Recorded data were statistically analyzed. Whether impression copings were splinted or not, there was no significant difference among custom tray group, plastic metal combination tray group, and polycarbonate stock tray group. Significant statistical difference in vertical fit discrepancy was found between splinted and non-splinted impression copings group with custom tray, plastic metal combination tray and polycarbonate stock tray (p<0.05).