• 제목/요약/키워드: Side Pressure

검색결과 1,812건 처리시간 0.029초

코리올리힘 이 作용하는 亂流境界層內 의 流動 에 관한 硏究 (Flow in turbulent boundary layers with coriolis force)

  • 이규한
    • 대한기계학회논문집
    • /
    • 제9권2호
    • /
    • pp.181-189
    • /
    • 1985
  • 본 연구에서는 단순유로인 단면이 장방형인 각통을 그것에 수직한 축둘레에 회전시켜서 유로의 압력측 및 부압측에서의 속도 및 변동속도성분의 거동을 실험적으 로 조사함으로서 코리올리힘이 난류경계층 내의 유동에 미치는 영향을 구명하였다.

왕복동 압축기의 성능에 대하여 (THE CHARACTERISTIC OF A TWO STAGE AMMONIA RECIPROCATING COMPRESSOR)

  • 조권옥;오후규
    • 한국수산과학회지
    • /
    • 제10권1호
    • /
    • pp.65-69
    • /
    • 1977
  • The characteristics of two stage compressor which is constituted of two separated reciprocating compressors was tested measuring the volumetric efficiency of each compressor at suction of both bighandlowpressdresideusillgorificetypeflolrmeters. The volumetric efficiency of low pressure side compressor was lower than that of the high side when they were operating under the same compression ratio. And it tended to reduce obviously by lowering evaporating temperature resulting in a markable reduction of refrigerating capacity at the same time. It is assumed that the falling of volumetric efficiency at low side compressor was directed by the decrease in evaporating temperature which derives the falls of gas pressure at suction, increase in compression ratio, and gas flow resistance at suction and discharge valves.

  • PDF

EFFECT OF THE SHAPE OF IMPINGEMENT PLATE ON THE VAPORIZATION AND FORMATION OF FUEL MIXTURE IN IMPINGING SPRAY

  • Kang, J.J.;Kim, D.W.;Choi, G.M.;Kim, D.J.
    • International Journal of Automotive Technology
    • /
    • 제7권5호
    • /
    • pp.585-593
    • /
    • 2006
  • The effect of the shape of the side wall on vaporization and fuel mixture were investigated for the impinging spray of a direct injection(DI) gasoline engine under a variety of conditions using the LIEF technique. The characteristics of the impinging spray were investigated under various configurations of piston cavities. To simulate the effect of piston cavity configurations and injection timing in an actual DI gasoline engine, the parameters were horizontal distance from the spray axis to side wall and vertical distance from nozzle tip to impingement plate. Prior to investigating the side wall effect, experiments on free and impinging sprays for flat plates were conducted and these results were compared with those of the side wall impinging spray. For each condition, the impingement plate was located at three different vertical distances(Z=46.7, 58.4, and 70 mm) below the injector tip and the rectangular side wall was installed at three different radial distances(R=15, 20, and 25 mm) from the spray axis. Radial propagation velocity from spray axis along impinging plate became higher with increasing ambient temperature. When the ambient pressure was increased, propagation speed reduced. High ambient pressures tended to prevent the impinging spray from the propagating radially and kept the fuel concentration higher near the spray axis. Regardless of ambient pressure and temperature fully developed vortices were generated near the side wall with nearly identical distributions, however there were discrepancies in the early development process. A relationship between the impingement distance(Z) and the distance from the side wall to the spray axis(R) was demonstrated in this study when R=20 and 25 mm and Z=46.7 and 58.4 mm. Fuel recirculation was achieved by adequate side wall distance. Fuel mixture stratification, an adequate piston cavity with a shorter impingement distance from the injector tip to the piston head should be required in the central direct injection system.

정규압밀된 연약점토의 압밀시험시 측면 마찰의 영향 (Effect of Side Friction on Consolidation Test of Normally Consolidated Kaolinite Slurry)

  • 이장근
    • 한국지반환경공학회 논문집
    • /
    • 제9권3호
    • /
    • pp.61-68
    • /
    • 2008
  • 압밀시험시 시료의 두께에 대한 직정의 비율이 크면 일반적으로 측면마찰은 없다고 간주된다. 그러나, 시료의 두께가 커질수록 측면 마찰의 영향은 무시할 수 없게 된다. 본 연구에서는 정규압밀된 카올리나이트 슬러리의 압밀시험시 측면마찰의 영향을 조사하였다. 압밀시험을 통해 압밀시험곡선, 과잉간극수압, 압밀-간극비, 투수계수-간극비 관계를 측정하였고, 압밀-간극비 관계에 있어 측면마찰의 영향을 고려하기 위해 Taylor(1942)가 제안한 식을 적용하였다. 측정된 압밀시험곡선과 과잉간극수압에 대해 수치해석 결과와 비교 분석을 통해 측면 마찰이 압밀시험에 미치는 영향을 검토하였다. 그 결과, 측면 마찰의 영향을 고려한 수치해석 결과는 측면 마찰을 무시한 결과보다 측정값에 근사한 것으로 나타났으며, 측면 마찰은 압밀-간극비 관계 뿐만 아니라 압밀시간에도 영향을 주는 요인이라는 결과를 얻을 수 있었다.

  • PDF

Non-Gaussian feature of fluctuating wind pressures on rectangular high-rise buildings with different side ratios

  • Jia-hui Yuan;Shui-fu Chen;Yi Liu
    • Wind and Structures
    • /
    • 제37권3호
    • /
    • pp.211-227
    • /
    • 2023
  • To investigate the non-Gaussian feature of fluctuating wind pressures on rectangular high-rise buildings, wind tunnel tests were conducted on scale models with side ratios ranging from 1/9~9 in an open exposure for various wind directions. The high-order statistical moments, time histories, probability density distributions, and peak factors of pressure fluctuations are analyzed. The mixed normal-Weibull distribution, Gumbel-Weibull distribution, and lognormal-Weibull distribution are adopted to fit the probability density distribution of different non-Gaussian wind pressures. Zones of Gaussian and non-Gaussian are classified for rectangular buildings with various side ratios. The results indicate that on the side wall, the non-Gaussian wind pressures are related to the distance from the leading edge. Apart from the non-Gaussianity in the separated flow regions noted by some literature, wind pressures behind the area where reattachment happens present non-Gaussian nature as well. There is a new probability density distribution type of non-Gaussian wind pressure which has both long positive and negative tail found behind the reattachment regions. The correlation coefficient of wind pressures is proved to reflect the non-Gaussianity and a new method to estimate the mean reattachment length of rectangular high-rise building side wall is proposed by evaluating the correlation coefficient. For rectangular high-rise buildings, the mean reattachment length calculated by the correlation coefficient method along the height changes in a parabolic shape. Distributions of Gaussian and non-Gaussian wind pressures vary with side ratios. It is inappropriate to estimate the extreme loads of wind pressures using a fixed peak factor. The trend of the peak factor with side ratios on different walls is given.

전단동축형 분사기의 유량계수에 대한 형상학적 변수들의 영향 (Effect of Geometrical Parameters on Discharge Coefficients of a Shear Coaxial Injector)

  • 안종현;이근석;안규복
    • 한국분무공학회지
    • /
    • 제25권3호
    • /
    • pp.95-102
    • /
    • 2020
  • Six shear coaxial injectors for a 3 tonf-class liquid rocket engine using oxygen and methane as propellants were designed and manufactured by considering geometric design parameters such as a recess length and a taper angle. Cold-flow tests on the injectors were performed using water and air as simulants. By changing the water mass flow rate and air mass flow rate, the injection pressure drop under single-injection and bi-injection was measured. The discharge coefficients through the injector oxidizer-side and fuel-side were calculated and the discharge coefficient ratio between bi-injection and single-injection was obtained. Under single-injection, the recess served to reduce the injection pressure drop on the injector fuel-side. For the injectors without recess, the discharge coefficients under bi-injection were almost the same as those under single-injection. However, for the injectors with recess, the taper angle and bi-injection had a significant effect on the discharge coefficient.

뇌졸중 후 편마비 환자의 보행능력 향상에 따른 질량중심 좌우이동의 변화 (The Change of Lateral Shift of Center of Pressure according to the Gait Improvement in Post-Stroke Hemiplegic Patients)

  • 이일석;박기언;홍해진;성강경;이상관
    • 대한한방내과학회지
    • /
    • 제35권4호
    • /
    • pp.448-454
    • /
    • 2014
  • Objectives: The aim of this study was to analyze the change of lateral shift of Center of Pressure (CoP) according to the gait improvement in post-stroke hemiplegic patients and to investigate relationship between the change of motor grade and lateral shift of CoP. Methods: We measured the lateral shift of CoP and motor grade of eight post-stroke hemiplegic patients at the beginning of dependent gait and independent gait. Results: We found that CoP tended to be shifted to the non-affected side when patients started to walk independently. Furthermore, there was no relationship between the change of motor grade and lateral shift of CoP. Conclusions: This result may suggest it is more important to control the non-affected side than the affected side, at least until the beginning independent gait.

The Effects of TENS Applied to Affected Lower Extremities on Balance in Stroke Patients

  • Lee, Kyu-Ri;Jang, Sang-Hun
    • 대한물리의학회지
    • /
    • 제9권3호
    • /
    • pp.255-262
    • /
    • 2014
  • PURPOSE: This study was to investigate the effectiveness of TENS on balance in stroke patients by analyzing some components such as foot pressure, limit of stability and velocity sway after providing somatosensroy input using TENS. METHODS: Twenty five subjects participated and were randomly divided into two groups, TENS group (n=13) and control group (n=12) by the computer program. Interventions were given to subjects 5 days a week for four weeks. TENS group were treated with TENS for 60 minutes in addition to the conventional therapy which included 30-minute exercise and rehabilitation ergometer training for 15 minutes. Control group performed only conventional therapy. TENS was applied on the skin of soleus, tibialis anterior, tensor fascia latae and vastus medialis in affected side. Foot pressure, limit of stability and velocity sway for balance test were measured using Biorescue. RESULTS: TENS group was significantly increased limit of stability and foot pressure in affected side more than control group. And in eye closed condition, TENS group was significantly decreased velocity sway more than control group. CONCLUSION: The application of TENS is effective to improve the somatosensory input of affected side and to increase the motor function and balance ability.

스퀼러팁의 압력면 개방길이 변화에 따른 터빈 익렬 팁간극 유동 특성 및 압력손실 (Tip Gap Flow and Aerodynamic Loss Generation over a Cavity Squealer Tip with the Variation of Pressure-Side Opening Length in a Turbine Cascade)

  • 천주홍;이상우
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.5-10
    • /
    • 2012
  • The effect of pressure-side opening length on three-dimensional flow fields and aerodynamic losses downstream of a cavity squealer tip has been investigated in a turbine rotor cascade for the squealer rim height-to-chord ratio and tip gap height-tochord ratio of $h_{st}/c$ = 5.05% and h/c = 2.0% respectively. The opening length-to-camber ratio is changed to be $OL/c_c$ = 0.0, 0.1, 0.2, 0.3, 0.4, 0.5, and 0.7 The results show that longer OL leads not only to weaker secondary flow but also to lower aerodynamic loss in the tip leakage vortex region, while it significantly widens the area with high aerodynamic loss in the passage vortex region. The aerodynamic loss coefficient mass-averaged all over the measurement plane is kept almost constant for $0.0{\leq}OL/c_c{\leq}0.3$, whereas it increases rapidly for $OL/c_c$ > 0.3 in proportion to $OL/c_c$. There is little deterioration in flow turning with increasing $OL/c_c$.

파울링 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 예측 모델링 (Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System)

  • 안영철;이재근
    • 설비공학논문집
    • /
    • 제17권3호
    • /
    • pp.262-267
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate and to model the air-side particulate fouling characteristics of the heat exchangers using accelerated particle loading system. The main variables of the modeling equation are face velocity and dust concentration. The modeling equation shows good agreements with the experimental results at the face velocity of 0.5, 1.0, 1.5 m/s and the dust concentration of 1.28 and $3.84\;g/m^3$. It will be very useful to predict fouling characteristics such as variations of pressure drop and heat transfer capacity in finned-tube heat exchangers of air conditioners.