• Title/Summary/Keyword: Si steel

Search Result 720, Processing Time 0.03 seconds

Preparation of Slow-Release Potassium Silicate Fertilizer Using Converter Slag (전로(轉爐)슬래그를 활용(活用)한 완효성(緩效性) 칼리 비료(肥料)의 제조(製造) 특성(特性))

  • Yang, Yeong-Ho;Kim, Young-Hwan;Ko, In-Yong
    • Resources Recycling
    • /
    • v.16 no.4
    • /
    • pp.10-16
    • /
    • 2007
  • As a basic study for reusing converter slag as slow-release potassium fertilizer by a sintering process, powdery converter slag and reagent grade $SiO_2\;and\;K_2CO_3$ were mixed with ball mill above 24 hours and sintered at $900^{\circ}C{\sim}1000^{\circ}C\;for\;10{\sim}60$ min. Basicity of the mixed powder was controlled to 0.7, 1.0 and 1.4 and content of $K_2O$ was fixed with 22 mass%. After sintering, property of the potassium fertilizer was investigated with X-ray diffraction pattern and ICP analysis. Also effects of basicity, sintering temperature and time on the making slow-release potassium fertilizer was investigated. Water solubility of KBO in sample were decreased with sintering time, temperature and decreased with basicity. Citric acid solubility of $K_2O$ were increased with basicity and decreased with sintering temperature.

The influence of nano-silica on the wear and mechanical performance of vinyl-ester/glass fiber nanocomposites

  • Sokhandani, Navid;Setoodeh, AliReza;Zebarjad, Seyed Mojtaba;Nikbin, Kamran;Wheatley, Greg
    • Advances in nano research
    • /
    • v.13 no.1
    • /
    • pp.97-111
    • /
    • 2022
  • In the present article, silica nanoparticles (SNPs) were exploited to improve the tribological and mechanical properties of vinyl ester/glass fiber composites. To the best of our knowledge, there hasn't been any prior study on the wear properties of glass fiber reinforced vinyl ester SiO2 nanocomposites. The wear resistance is a critical concern in many industries which needs to be managed effectively to reduce high costs. To examine the influence of SNPs on the mechanical properties, seven different weight percentages of vinyl ester/nano-silica composites were initially fabricated. Afterward, based on the tensile testing results of the silica nanocomposites, four wt% of SNPs were selected to fabricate a ternary composite composed of vinyl ester/glass fiber/nano-silica using vacuum-assisted resin transfer molding. At the next stage, the tensile, three-point flexural, Charpy impact, and pin-on-disk wear tests were performed on the ternary composites. The fractured surfaces were analyzed by scanning electron microscopy (SEM) images after conducting previous tests. The most important and interesting result of this study was the development of a nanocomposite that exhibited a 52.2% decrease in the mean coefficient of friction (COF) by augmenting the SNPs, which is beneficial for the fabrication/repair of composite/steel energy pipelines as well as hydraulic and pneumatic pipe systems conveying abrasive materials. Moreover, the weight loss due to wearing the ternary composite containing one wt% of SNPs was significantly reduced by 70%. Such enhanced property of the fabricated nanocomposite may also be an important design factor for marine structures, bridges, and transportation of wind turbine blades.

Resistance to Chloride Attack of FRP Hybrid Bar After Freezing and Thawing Action (동결융해 이후의 FRP Hybrid Bar의 부식 저항성)

  • Ryu, Hwa-Sung;Park, Ki-Tae;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.1
    • /
    • pp.59-65
    • /
    • 2018
  • RC(Reinforced Concrete) structures are exposed to various exterior conditions, and the performances of both chloride resistance and freezing/thawing action are evaluated for those exposed to corrosive environment-sea shore. Recently developed FRP Hybrid Bars which is coated with glass fiber and epoxy with core steel has an engineering advantage of higher Elasticity than FRP rod. In this work, corrosion resistance, weight loss, and bond strength are evaluated for the FRP Hybrid Bar tested through freezing/thawing action for 300cycles. The double coated FRP Hybrid Bar shows the least weight loss without defection due to freezing/thawing action. Bond strength in FRP Hybrid Bar increases to 120% of normal steel through torturity effect with Si-coating. Bond strength in normal steel shows 0.86~0.89times in 3-day corrosion acceleration and 0.35~0.38times in 5-day corrosion acceleration, however, that in FRP Hybrid Bar shows little changes in bond strength before and after freezing/thawing action.

Performance assessment of buckling restrained brace with tubular profile

  • Cao, Yan;Azar, Sadaf Mahmoudi;Shah, S.N.R.;Salih, Ahmed Fathi Mohamed;Thiagi, Tiana;Jermsittiparsert, Kittisak;Ho, Lanh Si
    • Advances in nano research
    • /
    • v.8 no.4
    • /
    • pp.323-333
    • /
    • 2020
  • In recent years, there has been an upsurge for the usage of buckling restrained braces (BRB) rather than ordinary braces, as they have evidently performed better. If the overall brace buckling is ignored, BRBs are proven to have higher energy absorption capacity and flexibility. This article aims to deliberate an economically efficient yet adequate type of all-steel BRB, comprised of the main components as in traditional ones, such as : (1) a steel core that holds all axial forces and (2) a steel restrainer tube that hinders buckling to occurr in the core; there is a more practical detailing in the BRB system due to the elimination of a filling mortar. An investigation has been conducted for the proposed rectangular-tube core BRB and it is hysteric behavioral results have been compared to previous researches conducted on a structure containing a similar plate core profile that has the same cross-sectional area in its core. A loss of strength is known to occur in the BRB when the limiting condition of local buckling is not satisfied, thus causing instability. This typically occurs when the thickness of the restrainer tube's wall is smaller than the cross-sectional area of the core plate or its width. In this study, a parametric investigation for BRBs with different formations has been performed to verify the effect of the design parameters such as different core section profiles, restraining member width to thickness ratio and relative cross-sectional area of the core to restrainer, on buckling load evaluation. The proposed BRB investigation results have also been presented and compared to past BRB researches with a plate profile as the core section, and the advantages and disadvantages of this configuration have been discussed, and it is concluded that BRBs with tubular core section exhibit a better seismic performance than the ones with a plate core profile.

A Study on the Design Concept & Construction Method of Office Building with Stacks at Thermal Power Plant (화력발전소 연돌통합형 종합사무동의 설계개념과 시공공법 연구)

  • Kim, Si-Hyun;Choi, Jang-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.677-686
    • /
    • 2016
  • A thermal power plant is the first CFBC (Circulating Fluidized Bed Combustion) power plant consisting of 2 boilers-1 turbine. The optimal height of a stack needs to be approximately 156 meters in the case of this thermal power plant; however, the thermal power plant sites satisfy a function and reduce the construction cost by using mountains in the sites after cutting the ground and locating an integrated office and chimney at an altitude of 70 meters thereby lowering the height of the stack to 86 meters. In addition, the integrated office, which has a combined stack style with a unique design, is constructed by connecting with 2 stacks and disposing the office and an observatory in the space between them. Therefore, this study examined the design concept that fulfils the structural, functional, and aesthetic factors, harmoniously by joining the integrated office and the stack, which are disparate, and investigated special construction methods (Slip Form, Steel Inner Flue & Lift-up) through which heterogeneous architectures are structurally, functionally, and aesthetically constructed.

Microstructure and Creep Fracture Characteristics of Dissimilar SMA Welds between Inconel 740H Ni-Based Superalloy and TP316H Austenitic Stainless Steel (Inconel 740H 니켈기 초내열합금과 TP316H 스테인리스강의 이종금속 SMA 용접부의 미세조직과 크리프 파단 특성)

  • Shin, Kyeong-Yong;Lee, Ji-Won;Han, Jung-Min;Lee, Kyong-Woon;Kong, Byeong-Ook;Hong, Hyun-Uk
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.33-40
    • /
    • 2016
  • The microstructures and the creep rupture properties of dissimilar welds between the Ni-based superalloy Inconel 740H and the non-stabilized austenitic stainless steel TP316H have been characterized. The welds were produced by shielded metal arc (SMA) welding process with the AWS A5.11 Class ENiCrFe-3 filler metal, commonly known as Inconel 182 superalloy. Postweld heat treatment at $760^{\circ}C$ for 4 hours was conducted to form ${\gamma}^{\prime}$ strengthener in Inconel 740H. The austenitic weld metal produced by Inconel 182 had a dendritic microstructure, and grew epitaxially from the both sides of Inconel 740H and TP316H base metals. Since both Inconel 740H and TP316H did not undergo any solid-state transformation during welding process, there were no heat-affected-zone (HAZ) sub-regions and the coarsoned grains near the weld interface were limited to a narrow region. The hardness of Inconel 182 weld metal was ~220 Hv. The gradual hardness decrease was detected at HAZ of TP316H, and the TP316H base metal displayed the lowest hardness value (~180 Hv) whilst the Inconel 740H showed the highest hardness value (~400 Hv). Fracture after creep occurred at the center of weld metal, regardless of creep condition. It was found that during creep the cracks initiated and propagated along interdendritic regions and grain boundaries at which Laves particles enriched in Nb, Si and Cr were present. The appropriate design of weld metal was discussed to suppress the creep-induced cracking of the present dissimilar weld.

Pulmonary Function and Influence Factors among Residents around Gwangyang Steel Mill (광양 제철소 주변지역 거주자들의 폐기능과 영향 요인)

  • Hong, Eun-Ju;Ahn, Gi-Sub;Chung, Eun-Kyung;Choi, Jae-Ho;Guo, Xinbiao;Son, Bu-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.3
    • /
    • pp.182-192
    • /
    • 2011
  • Objectives: This study aims to identify the influential factors on the pulmonary function of targeted general residents in the areas surrounding Gwangyang Steel Mill. Methods: An PFT (Pulmonary Function Test) was conducted from May 2007 to November 2007 on 974 target residents (438 male, 536 female), including an exposed group (674 people) who resided within a radius of 5 km from Gwangyang Steel Mill in Gwangyang-si, Jeollanam-do and a control group (300 people) who resided outside a radius of 15 km. A survey related to personal characteristics, life habits, respiratory diseases and allergic symptoms, medical histories and living environments of the residents was also conducted to identify influential factors on pulmonary function. Results: As %$FEV_1$ and %FVC of the exposed group are 99.17% and 96.98%, respectively, and those of the control group are 105.47% and 101.91%, respectively, with the PFT values of the exposed group being lower than those of the control group (p<0.001), it turns out that the pollution in the industrial complex is likely to trigger a reduction in the pulmonary function of local residents. The odds ratio analysis result for asthma diagnosis history indicates that the odds ratios tend to be higher among surveyed residents who are living near above-average traffic volumes and are using beds, where it is statistically meaningful that especially the odds ratios are higher if the residences are closer to roads (p<0.01, CI=1.12-4.52). The factors that affect the FEV1 are identified as smoking, passive smoking, asthma diagnosis history, nasal congestion symptoms and allergic eye disease ($R^2$=0.154, p<0.001). The factors that affect the FVC are identified as smoking, passive smoking, asthma diagnosis history and allergic coryza ($R^2$=0.158, p<0.001). In addition, the analysis result for the relevance of air pollution levels to pulmonary function ($FEV_1$, FVC) shows that FEV1 and FVC tend to decrease as the concentration of $O_3$ increases. Conclusions: We believe that this study may provide preliminary data for the development of preventive measures for health effects on the residents and environmental health control measures for environmental pollution in the industrial complex area.

Effect of Al Content Variation on High Temperature Gas Nitriding in 13%Cr-0.16%C Stainless Steel (13%Cr-0.17%C 스테인리스강의 고온 가스질화에 미치는 Al 함량 변화의 영향)

  • Park, B.T.;Kim, J.M.;Kang, H.J.;Kong, J.H.;Kang, C.Y.;Sung, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.24 no.6
    • /
    • pp.318-326
    • /
    • 2011
  • This study has been performed to investigate the effect of Al addition on High Temperature Gas Nitriding (HTGN) in 13%Cr-0.16%C stainless steel with different Al contents of 0.54%, 1.76% and 2.36%, respectively. HTGN treatment was carried out at $1100^{\circ}C$ for 1 hr, 5 hrs and 10 hrs. Nitrogen-permeated surface layers showed round type carbides of $Cr_{23}C_6$ and needle type nitrides of AlN in the matrix of martensite, representing 600~700 Hv. And the thickness of the surface layer increased with increasing Al content and HTGN treatment time. The inner region that was not permeated nitrogen showed chromium carbides in the mixed phase of martensite and ferrite for the 0.53% Al alloyed steel, however chromium carbides in the matrix of ferrite single phase were shown for the steels with the addition of 1.76%Al and 2.36%Al, representing the hardness of ~200 Hv. During nitrogen permeation from surface to the interior, substitutional elements of Cr, Al and Si moved toward the surface and interstitial element of carbon also moved from interior to the surface. This movement of alloying elements leads high concentration of these elements at the outmost surface, subsequently the lowest peak of substitutional elements were shown in the vicinity of near surface. After showing the lowest peak, the high concentration region of Al and C were formed due to the continuous movement of Al toward the surface. The long discontinuous precipitates of $Cr_{23}C_6$ and AlN were formed along the outmost surface owing to the high concentration of these alloying elements.

Cooling Characteristic Analysis of Transformer's Radiator (변압기 냉각 특성 해석)

  • Kim, Hyun-Jae;Yang, Si-Won;Kim, Won-Seok;Kweon, Ki-Yeoung;Lee, Min-Jea
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.1920-1925
    • /
    • 2007
  • A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study, we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design.

  • PDF

Mechanical behavior of stud shear connectors embedded in HFRC

  • He, Yu-Liang;Wu, Xu-Dong;Xiang, Yi-Qiang;Wang, Yu-Hang;Liu, Li-Si;He, Zhi-Hai
    • Steel and Composite Structures
    • /
    • v.24 no.2
    • /
    • pp.177-189
    • /
    • 2017
  • Hybrid-fiber reinforced concrete (HFRC) may provide much higher tensile and flexural strengths, tensile ductility, and flexural toughness than normal concrete (NC). HFRC slab has outstanding advantages for use as a composite bridge potential deck slab owing to higher tensile strength, ductility and crack resistance. However, there is little information on shear connector associated with HFRC slabs. To investigate the mechanical behavior of the stud shear connectors embedded in HFRC slab, 14 push-out tests (five batches) in HFRC and NC were conducted. It was found that the stud shear connector embedded in HFRC had a better ductility, higher stiffness and a slightly larger shear bearing capacity than those in NC. The experimentally obtained ultimate resistances of the stud shear connectors were also compared against the equations provided by GB50017 2003, ACI 318-112011, AISC 2011, AASHTO LRFD 2010, PCI 2004, and EN 1994-1-1 (2004), and an empirical equation to predict the ultimate shear connector resistance considering the effect of the HFRC slabs was proposed and validated by the experimental data. Curve fitting was performed to find fitting parameters for all tested specimens and idealized load-slip models were obtained for the specimens with HFRC slabs.