• 제목/요약/키워드: Shut-down

검색결과 278건 처리시간 0.031초

유동층 저회냉각기에서의 입자 혼합특성과 비유동 진단 (Characteristics of particle mixing and detection of poor fluidization in a fluidized bed ash cooler)

  • 김동원;이종민;김재성;김종진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.231-237
    • /
    • 2005
  • Interruption of good fluidization in a fluidized bed ash cooler(FBAC) for discharging bed materials such as sand or coal ash particles from the CFB combustor is frequently happened because of agglomeration of the particles in the bed. This unstable operation may, in the worst case, result in an unscheduled boiler shut down. In this study, we examined the operation problems of the FBAC of Tonghae CFB boiler and studied and introduced the simple detection and solution techniques with analyzing the mixing property and the occurrence of defluidization in a simulated fluidized bed ash cooler system (0.5m-H x 0.5m-W x 1.0m-L). The bridge of the large particles at the bed surface could be observed, and this caused to form the defluidization area at the entrance of the FBAC. The defluidization was affected not only by airflow rates but also by the particles discharging rates as well as particle size distribution in the FBAC. The local defluidization could be detected by analysis of the accumulated standard deviation error at a given period of time. Also, the regulation of the overall or local airflow rate made clearing up the local defluidization possible.

  • PDF

멀티레벨 인버터의 순간정전 보상알고리즘에 관한 연구 (Voltage Dip Compensation Algorithm Using Multi-Level Inverter)

  • 윤홍민;김용
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.133-140
    • /
    • 2013
  • Cascaded H-Bridge multi-level inverters can be implemented through the series connection of single-phase modular power bridges. In recent years, multi-level inverters are becoming increasingly popular for high power applications due to its improved harmonic profile and increased power ratings. This paper presents a control method for balancing the dc-link voltage and ride-through enhancement, a modified pulse width-modulation Compensation algorithm of cascaded H-bridge multi-level inverters. During an under-voltage protection mechanism, causing the system to shut down within a few milliseconds after a power interruption in the main input sources. When a power interruption occurs finish, if the system is a large inertia restarting the load a long time is required. This paper suggests modifications in the control algorithm in order to improve the sag ride-through performance of ac inverter. The new proposed strategy recommends maintaining the DC-link voltage constant at the nominal value during a sag period, experimental results are presented.

인터넷 역기능 예방을 위한 인터넷 윤리 교육 개선 방안 (The Improvement Method of Internet Ethics Education for the Prevention of Internet Aftereffect)

  • 이윤배
    • 한국정보통신학회논문지
    • /
    • 제17권6호
    • /
    • pp.1432-1440
    • /
    • 2013
  • 인터넷 사용의 장점에도 불구하고 많은 역기능도 있다. 가장 잘 알려진 역기능에는 인터넷 중독, 개인정보 침해, 저작권 침해, 불법 정보 유포, 사이버 폭력, 사이버 사기, 해킹, 바이러스 유포, 그리고 사이버 매매춘 등이 있다. 지금까지 정부와 공공 기관에서는 이 같은 인터넷 역기능을 예방하고 줄이기 위해 노력하고 있으나 한계에 직면하고 있다. 따라서 인터넷 역기능을 예방하기 위한 한 가지 방법으로 인터넷 윤리 교육을 강화하는 것이다. 따라서 본 연구의 목적은 인터넷 역기능의 현 상황을 고찰 분석하고 하고 아울러, 역기능을 해결할 수 있는 인터넷 윤리 교육의 개선 방안을 제시한다.

원자력 발전소 케이블 상태 감시방법의 국내외 동향 (A Review of Cable Condition Monitoring for Nuclear plants)

  • 강윤식;김철환;구철수;김복렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.555-557
    • /
    • 2000
  • 원자력 발전소에서 사용되어지는 케이블은 전원 및 제어신호를 안정하게 전달하는 역할을 하며, 비상상태 발생시에는 원자로를 안전하게 shut-down시키는 통로 역할을 하므로 매우 중요하다. 케이블 상태 감시시 절연 및 피복재료는 종류 및 배합내용이 다양하기 때문에 종래의 자료로부터 전선과 케이블의 열화 또는 수명을 추정하기가 극히 어려우며 방사선에 노출이 되는 케이블의 경우 노화현상의 진행이 빠르고 방사선 열화로 수명이 단축되므로 국내 실정을 감안한 독자적인 검증방법 도출, 규제기술 기반 구축 필요 및 규제의 합리화와 효율화 필요성이 대두되고 있다. 기존에 사용해온 케이블 진단 방법에는 절연 파괴 강도 측정을 통한 노화진단, 산화 방지능력 측정을 통한 노화진단, 자켓 및 절연체의 판단, 연신율에 의한 노화진단, 케이블 Indenter에 의한 노화진단, 온도 및 방사선 등의 특정상태에 대한 평가, 유사한 환경조건에 대한 주기적 검토 등이 있다. 기존의 국내외 케이블 상태 감시방법을 조사 연구하므로서 케이블 열화에 대비한 수명관리 규제 기술 및 상태감시 (Condition Monitoring : CM) 기술의 평가 기준을 결정 하고자 한다.

  • PDF

유해 해양생물 해파리 피해 저감 방안 연구 (A Study on the Damage Reduction Strategy Against a Harmful Aquatic Organism, Jellyfish's Bloom)

  • 박성욱;이경훈;윤원득;이동길;김성훈;양용수;이건호
    • 수산해양교육연구
    • /
    • 제27권1호
    • /
    • pp.49-62
    • /
    • 2015
  • As methods reducing damages by jellyfish which enter the coastal areas of Korea, attaching cutting devices to towing nets of otter trawls or pair trawls and/or using a canvas type of cutting nets of small fishing boats have been widely utilized. In order to reduce shut-down damages of power plants in coastal areas due to the mass influx of marine organisms including jellyfish, a possible improvement of the traveling water screen system and various jellyfish influx blocking devices were suggested in this study. The results could be utilized as an important index for reducing damages by jellyfish bloom which cause on a massive scale in summer in Korea.

SELECTION OF BUS TRANSPORTATION ROUTES FOR REVITALIZATION OF DOWNTOWN CITY BY USING GIS

  • Imaoka, Yoshiko;Gotoh, Keinosuke
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.732-735
    • /
    • 2006
  • Downtown cities in Japan are facing sharp fall in customers and continued shut down of shops due to decrease of population, increase in family cars and flowing of customers into the suburban large-scale retail stores. Omura City in Nagasaki Prefecture, Japan is no exception to this. For the revitalization of the downtown, many actions have been taken to open the vacant shops. However, transportation problem is the most important one to be solved for the citizens including the elderly people having difficulty in movement. Accordingly, this study was aimed at the revitalization of the downtown by substantiality public transportation. We have attempted to develop routes from the view-point of convenience by using Analytic Hierarchy Process (AHP) and Geographic Information Systems (GIS). As a result of the study, we were able to select three bus transportation areas by incorporating qualitative factors into the analysis. Finally, the study concluded that, revitalization activities of the downtown city itself is required in addition to re-structuring of bus transportation system for the revitalization of the downtown city.

  • PDF

해양플랜트 폭발사고 방지를 위한 가스감지기 위치 선정 방법 연구 (Development of Gas Detector Location Index Technique to Prevent Explosion Accidents of Offshore Plant)

  • 손정민;백점기;김상진
    • 대한조선학회논문집
    • /
    • 제54권1호
    • /
    • pp.63-70
    • /
    • 2017
  • Release of hazardous and flammable gas is a significant contributor to risk. The ignition of flammable gas clouds can lead to explosion accidents in the offshore installations. A gas detector, which is one of active protect systems, brings the module into a safe state through emergency shut down processes and reduces the damage by eliminating the dangerous releases. It is critical to understand the gas release, the wind field, and the complex geometry of installations to determine gas detector placement. In this paper, the Gas detector Location Index (GLI) which is a novel index for optimal detector location determination to efficiently prevent explosion accident using probabilistic approach.

온도 변화에 따른 수돗물 저장 저수조 내 잔류염소에 관한 수학적 모형 시뮬레이션 (Mathematical Model Simulations Assessing the Effects of Temperature on Residual Chlorine Concentrations in Water Storage Tanks)

  • 노유래;박준홍
    • 한국물환경학회지
    • /
    • 제33권2호
    • /
    • pp.187-196
    • /
    • 2017
  • To ensure hygienic safety of drinking water in a water storage tank, the concentrations of residual chlorine should be above a certain regulation level. In this study, we conducted model simulations to investigate the effects of temperature on residual chlorine in water storage tank conditions typically used in Seoul. For this, values of model parameters (decomposition rate constant, sorption coefficient, and evaporation mass transfer coefficient) were experimentally determined from laboratory experiments. The model simulations under continuous flow conditions showed that the residual chlorine concentrations were satisfied the water quality standard level (0.1 mg/L) at all the temperature conditions ($5^{\circ}C$, $10^{\circ}C$, $15^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$). Meanwhile, when the tanks had a no flow condition (i.e., no tap-water influent due to a sudden shut-down), the concentrations became lower than the regulatory level after certain periods. The findings from this modeling works simulating Seoul's water storage tanks suggested disappearance rate of residual chlorine could be reduced through the tanks design optimization with maintenance of low water temperature, minimization of air flow and volume, suppression of dispersion and the use of wall materials with low sorption ability.

가상행성 섭동력을 고려한 긴 주기 GPS 위성궤도예측기법 (Long-Term GPS Satellite Orbit Prediction Scheme with Virtual Planet Perturbation)

  • 유승수;이정혁;한진희;지규인;김선용
    • 제어로봇시스템학회논문지
    • /
    • 제18권11호
    • /
    • pp.989-996
    • /
    • 2012
  • The purpose of this paper is to analyze GPS (Global Positioning System) satellite orbital mechanics, and then to propose a novel long-term GPS satellite orbit prediction scheme including virtual planet perturbation. The GPS orbital information is a necessary prerequisite to pinpointing the location of a GPS receiver. When a GPS receiver has been shut down for a long time, however, the time needed to fix it before its reuse is too long due to the long-standing GPS orbital information. To overcome this problem, the GPS orbital mechanics was studied, such as Newton's equation of motion for the GPS satellite, including the non-spherical Earth effect, the luni-solar attraction, and residual perturbations. The residual perturbations are modeled as a virtual planet using the least-square algorithm for a moment. Through the modeling of the virtual planet with the aforementioned orbital mechanics, a novel GPS orbit prediction scheme is proposed. The numerical results showed that the prediction error was dramatically reduced after the inclusion of virtual planet perturbation.

로켓노즐에서 발생하는 횡력변동에 관한 연구 (Study on the Lateral Force Fluctuations in a Rocket Nozzle)

  • ;이종성;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.315-319
    • /
    • 2009
  • Investigation of the lateral force fluctuations in an axisymmetric overexpanded compressed truncated perfect (CTP) nozzle for the shutdown transient is presented. These nozzles experience side-loads during start-up and shut-down operations, because of the flow separation at nozzle walls. Two types of flow separations such as free shock separation (FSS) and restricted shock separation (RSS) shock structure occur. A two-dimensional unsteady numerical simulation has been carried out over an axisymmetric CTP nozzle to simulate the lateral force fluctuations in nozzle during shutdown process. Reynolds Averaged Navier-Stokes equations are numerically solved using a fully implicit finite volume scheme. Governing equations are solved by coupled implicit scheme. Two equation k-$\omega$ SST turbulence model is selected. Unsteady pressure is measured at four locations along the nozzle wall. Present pressure variation compared well with the experimental data. During shutdown transient, separation pattern varies from FSS to RSS and finally returns to FSS. Several pressure peaks are observed during the RSS separation pattern. These pressure peaks generate lateral force or side loads in rocket nozzle.

  • PDF