Characteristics of particle mixing and detection of poor fluidization in a fluidized bed ash cooler

유동층 저회냉각기에서의 입자 혼합특성과 비유동 진단

  • 김동원 (한전 전력연구원 수화력발전연구소) ;
  • 이종민 (한전 전력연구원 수화력발전연구소) ;
  • 김재성 (한전 전력연구원 수화력발전연구소) ;
  • 김종진 (한전 전력연구원 수화력발전연구소)
  • Published : 2005.10.06

Abstract

Interruption of good fluidization in a fluidized bed ash cooler(FBAC) for discharging bed materials such as sand or coal ash particles from the CFB combustor is frequently happened because of agglomeration of the particles in the bed. This unstable operation may, in the worst case, result in an unscheduled boiler shut down. In this study, we examined the operation problems of the FBAC of Tonghae CFB boiler and studied and introduced the simple detection and solution techniques with analyzing the mixing property and the occurrence of defluidization in a simulated fluidized bed ash cooler system (0.5m-H x 0.5m-W x 1.0m-L). The bridge of the large particles at the bed surface could be observed, and this caused to form the defluidization area at the entrance of the FBAC. The defluidization was affected not only by airflow rates but also by the particles discharging rates as well as particle size distribution in the FBAC. The local defluidization could be detected by analysis of the accumulated standard deviation error at a given period of time. Also, the regulation of the overall or local airflow rate made clearing up the local defluidization possible.

Keywords