• Title/Summary/Keyword: Shunt

Search Result 1,335, Processing Time 0.032 seconds

Changes in the Luminal Surface of the PTFE Graft used in Systemic- pulmonary Shunt Operation (체폐단락술에 사용되었던 PTFE 인조혈관 내면의 변화)

  • Park, Yeong-Hwan;Jang, Byeong-Cheol;Sin, Dong-Hwan;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.836-843
    • /
    • 1996
  • Histologic, and scanning electron microscopic observa ions were made of 12 biopsy specimens from polytetrdiluoroethylene (PTFE) grafts that had been Implanted as systemic-pulmonAry shunt for improving oxygenation of cyanotic congenital heart disease and harvested near the end of pulmonary artery side at the time of redo shunt or tonal correction between 1985 and 1992. The types of shunt operation are modified Blalock-Taussig shunt in 10 cases, Waterston-Cooley shunt in 1 And Potts shunt in 1 case. The 5 mm PTFE graft was used In 10, 4mm in 1 and 6mm in 1 case. The mean duration of implantalion was 0 $\pm$ 14.1 months(rl.on 12 months to 55 months). The plAtelets were aggregated between gaps'of Coretex surface and intimal thickening was noted about 10 to 20 months after implantation. Endothelial cells were found in the 40-months patent PTFE graft by light and scanning electron microscopy. In the specimen of poor flow or zero flow graft, severe intimal hyperplasia and thrombi which was made of platelets were noted . Based on this experience, we think that the patency will be maintained well if the connective tissue could be Hxed firmly over the Inner layer of the Goretex and the endothelial cell layer sllould form over the con- nective tissue and platelet aggregation should be prevented.

  • PDF

Transmitted Noise Reduction Performance of Piezoelectric Single Panel through Piezo-damping (압전감쇠를 통한 압전단일패널의 전달 소음저감성능)

  • 이중근;김재환;김기선;이형식
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.2 no.2
    • /
    • pp.49-56
    • /
    • 2001
  • The possibility of a noise reduction of piezoelectric single Panels is experimentally studied. Piezoelectric single panel is basically a plate structure on which piezoelectric patch with shunt circuit is mounted. The use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. Piezo-damping is implemented by using a newly proposed tuning method. This method is based on electrical impedance model and maximizing the dissipated energy at the shunt circuit. By measuring the electrical impedance at the piezoelectric patch bonded on a structure, an equivalent electrical model is constructed near the system resonance frequency. Resonant shunt circuit for piezoelectric shunt damping is composed of register and inductor in series, and they are determined by maximizing the dissipated energy throughout the circuit. The transmitted noise reduction performance of single Panel is tested on an acoustic tunnel. The tunnel is a tube with a square cross section and a loud speaker is mounted at one side of the tube as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across Panels is measured. By enabling the piezoelectric shunt damping noise reduction is achieved at the resonance frequencies as well. Piezoelectric single panel with piezoelectric shunt damping is a promising technology for noise reduction in a broadband frequency.

  • PDF

Broadband Transmission Noise Reduction Performance of Smart Panels Featuring Piezoelectric Shunt Damping and Passive Characteristics (압전감쇠와 수동적 특성을 갖는 압전지능패널의 광대역 전달 소음저감성능)

  • 이중근;김재환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.2
    • /
    • pp.150-159
    • /
    • 2002
  • The possibility of a broadband noise reduction of piezoelectric smart panels is experimentally studied. Piezoelectric smart panel is basically a plate structure on which piezoelectric patch with shunt circuits is mounted and sound absorbing material is bonded on the surface of the structure. Sound absorbing materials can absorb the sound transmitted at mid frequency region effectively while the use of piezoelectric shunt damping can reduce the transmission at resonance frequencies of the panel structure. To be able to tune the piezoelectric shunt circuit, the measured electrical impedance model is adopted. Resonant shunt circuit composed of register and inductor in stories is considered and the circuit parameters are determined based on maximizing the dissipated energy through the circuit. The transmitted noise reduction performance of smart panels is investigated using an acoustic tunnel. The tunnel is a square crosses sectional tunnel and a loud speaker is mounted at one side of the tunnel as a sound source. Panels are mounted in the middle of the tunnel and the transmitted sound pressure across the panels is measured. Noise reduction performance of a double smart panel possessing absorbing material and air gap shows a good result at mid frequency region except the first resonance frequency. By enabling the piezoelectric shunt damping, noise reduction is achieved at the resonance frequency as well. Piezoelectric smart panels incorporating passive method and piezoelectric shunt damping are a promising technology for noise reduction in a broadband frequency.

Risk Factor Analysis for $SaO_2$ Instability after Systemic-pulmonary Shunt (전신-폐 단락술 후 산소포화도의 불안정성의 위험인자 분석)

  • Jung Sung-Ho;Yun Sok-Won;Park Jung-Jun;Seo Dong-Man;Kim Young-Hwue;Ko Jae-Kon;Park In-Sook;Yun Tae-Jin
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.277-283
    • /
    • 2005
  • Arterial oxygen saturation $(SaO_2)$ instability frequently takes place after systemic-pulmonary shunt without shunt occlusion. We analyzed actual incidence and risk factors for $SaO_2$ instability after shunt operations, and possible mechanisms were speculated on. Material and Method: Ninety three patients, who underwent modified Blalock-Taussig shunt from January 1996 to December 2000, were enrolled in this study. Adequacy of shunt was verified in all patients, either by ensuing one ventricle or biventricular repair later on or by appropriate pulmonary artery growth on postoperative angiogram. Age, body weight, hemoglobin level at operation were 3 day to 36 years (median: 1.8 months), 2.5kg to 51kg (median: 4.1kg) and $10.7\~24.3$ gm/dL (median: 15.2 gm/dL) respectively. Preoperative diagnoses were functional single ventricle with pulmonary stenosis or atresia in 39, tetralogy of Fallot in 38 and pulmonary atresia with intact ventricular septum in 16. Pulmonary blood flow (PBF) was maintained pre-operatively by patent ductus or previous shunt in 64 and by forward flow through stenotic right ventricular outflow tract (RVOT) in 29. $SaO_2$ instability was defined as $SaO_2$ less than $50\%$ for more than 1 hour with neither anatomic obstruction of shunt nor respiratory problem. Result: 10 patients $(10.7\%)$ showed $SaO_2$ instability after shunt operation. After shunt occlusion was ruled out by echocardiogram, they received measures to lower pulmonary vascular resistance (PVR), which worked within a few hours in all patients. Risk factors for $SaO_2$ instability included older age at operation (p=0.039), lower preoperative $SaO_2$ (p=0.0001) and emergency operation (p=0.001). PBF through stenotic RVOT showed marginal statistical significance (p=0.065). Conclusion: $SaO_2$ instability occurs frequently after shunt operation, especially in patients with severe hypoxia pre-operatively or unstable clinical condition necessitating emergency operation. Temporary elevation of pulmonary vascular resistance is a possible mechanism in this specific clinical setting.

Economical Installations and Regulations of Shunt Capacitors in A Distribution Line (배전선로에 있어서의 병렬 Coudenser의 경제적 설치 및 조정에 관한 연구)

  • 박영문
    • 전기의세계
    • /
    • v.15 no.5
    • /
    • pp.25-31
    • /
    • 1966
  • This paper derives the useful formulas for computing annual profits, and economical size, locations and regulating values of parallel shunt capacitors in case that they are installed in a distribution line. Inparticular, the derived formulas consider the influence of load variations in order to represent the actual load situations.

  • PDF

Surgical Treatment of Left Ventricular-Right Atrial Shunt (좌심실-우심방 단락의 외과적 치료)

  • 이응배;허동명
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.945-950
    • /
    • 1996
  • Twelve patients with left ventricular-right atrial shunt (LV-RA shunt) underwent surgical correction be- tween April 1982 and March 1995. Seven patients were male and five patients were female. Age ranged from 3 to 26 years with mean age of 8.5 years. On the preoperative chest PA views, increased pulmonary vascularity was noted in 3 cases and enlargement of right atrium in 4 cases. The mean preoperative cardiothoracic ratio was 0.59. Echocardiographic studies were obtained in 9 patients and the preoperative echocardiographic diagnoses were LV-RA shunt in 2 cases, ventricular septal defect (VSD) in 6 casei, and atrial septal defect (ASD) in 1 case. The preoperative ngiographic diagnoses which were obtained in all patients were LV-RA shunt in 5 cases, VSD in 5 cases, ASD in 1 case, and VSD with ASD in 1 case. The descriptions of defect of LV-RA shunt according to intraoperative findings were supravalvular defect in 5 cases(42%), infravalvular defect in 4 cases (33%), and combined defect in 3 cases (25%). Associated anomalies of tricuspid valve in 4 cases of infravalvular defect were perforation (3 cases) and cleft (1 case). Primary closure of the septal defect was performed through the right atriotomy in all but one patient. There was no operative death. One patient underwent reoperation because of the residual interventricular shunt. All patients have been in good condition.

  • PDF

Numerical Simulation of The Pressure-Flow Control Characteristics of Shunt Valves Used to Treat Patients with Hydrocephalus (수두층 치료용 션트밸브의 압력-유량 제어특성 수치해석)

  • 장종윤;이종선;서창민
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.403-412
    • /
    • 2001
  • The Present study analyzed the pressure-flow characteristics of a Korean shunt valve. Changes in the characteristic currie depending on the design parameters were also investigated. The Korean shunt valve used in the present study was constant pressure type and our analyses were validated through experiments. We applied fluid-structure interaction to solve the flow dynamic Problem because the small diaphragm in the valve was made from flexible silicone elastomers. Considering the material nonlinearity of the hyper-elastic material. the Mooney-Rivlin approximation was employed. The results of the numerical analyses were close to the experimental results The major Pressure drop was observed to happen in the small diaphragm. The slope of the pressure-flow characteristic curve was computed to be 0.37mm$H_2O$.hr/cc, which was similar to the average value of commercial shunt valves. 0.40mm$H_2O$.hr/cc. Therefore. our valves analyzed in the Present study showed a Proper Pressure control characteristics of the constant pressure type shunt valves. The opening pressure could be controlled by adjusting the amount of predeflection of the valve diaphragm. In order to obtain opening pressures of 25mm$H_2O$ and 80mm$H_2O$, respectively, and the required predeflection was found to be 10.2$\mu$m and 35.3$\mu$m. The flow orifice size was found to be within 10$\mu$m during valve operation Therefore, Precision design and manufacturing techniques are necessary for successful operations of the shunt valve. The study indicated the amount of predeflection as well as the magnitude of corner rounding of the diaphragm edge are important design parameters to influence the slope of the pressure-flow characteristic curve.

  • PDF

Follow-Up of Residual Shunt after Repair of Ventricular Septal Defect (심실중격결손 봉합 후 잔류 단락의 추적관찰)

  • 정태은;이장훈;김도형;백종현;이동협;이정철;한승세;이영환
    • Journal of Chest Surgery
    • /
    • v.35 no.8
    • /
    • pp.580-583
    • /
    • 2002
  • Background: Obtaining precise hemodynamic and morphological information in the early postoperative period after surgical correction of congenital heart disease is important in determining the need for future medical or surgical intervention. We investigated the residual shunting after surgical repair of simple ventricular septal defect in order to know the incidence of residual shunting in the postoperative period and the natural history of small residual shunts located in the peripatch area. Material and Method: Forty three consecutive patients under one year of age who underwent patch repair of a simple ventricular septal defect were evaluated for incidence of residual shunts by echocardiography. Result: Eleven patients had echocardiographic residual shunt in the peripatch area at immediate postoperative period, however, there were no patients who needed reoperation due to deteriorated hemodynamic effect of residual shunt. The incidence of residual shunts was not significantly different with type of ventricular septal defect and material used for closure. During follow up period, two patients were lost and remaining nine patients no longer showed evidence of residual shunt. The mean time of last evidence of shunt was $4.2{\pm}3.6$ months after operation. Conclusion: Residual peripatch shunt flow was frequently noted in the immediate postoperative period following surgical repair of ventricular septal defect, however, most of them were disappeared within six months.

Millimeter-wave Broadband Amplifier integrating Shunt Peaking Technology with Cascode Configuration (Cascode 구조에 Shunt Peaking 기술을 접목시킨 밀리미터파 광대역 Amplifier)

  • Kwon, Hyuk-Ja;An, Dan;Lee, Mun-Kyo;Lee, Sang-Jin;Moon, Sung-Woon;Baek, Tae-Jong;Park, Hyun-Chang;Rhee, Jin-Koo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.10 s.352
    • /
    • pp.90-97
    • /
    • 2006
  • We report our research work on the millimeter-wave broadband amplifier integrating the shunt peaking technology with the cascode configuration. The millimeter-wave broadband cascode amplifier on MIMIC technology was designed and fabricated using $0.1{\mu}m\;{\Gamma}-gate$ GaAs PHEMT, CPW, and passive library. The fabricated PHEMT has shown a transconductance of 346.3 mS/mm, a current gain cut off frequency ($f_T$) of 113 GHz, and a maximum oscillation frequency ($f_{max}$) of 180 GHz. To prevent oscillation of designed cascode amplifier, a parallel resistor and capacitor were connected to drain of common-gate device. For expansion of the bandwidth and flatness of the gain, we inserted the short stub into bias circuits and the compensation transmission line between common-source device and common-gate device, and then their lengths were optimized. Also, the input and output stages were designed using the matching method to obtain the broadband characteristic. From the measurement, we could confirm to extend bandwidth and flat gain by integrating the shunt peaking technology with the cascode configuration. The cascode amplifier shows the broadband characteristic from 19 GHz to 53.5 GHz. Also, the average gain of this amplifier is about 6.5 dB over the bandwidth.