• 제목/요약/키워드: Shower System

검색결과 50건 처리시간 0.032초

모바일 RFID 시스템의 인식거리 확대를 위한 전력 공급용 RF Shower 시스템 개발 (A Study on the RF Shower System to Extend Interrogating Range on Mobile RFID Reader)

  • 안시영;김용택;배성우;내관규;노형환;김기범;박준석;조홍구;오하령;성영락;송호준;장병준;이정석
    • 한국통신학회논문지
    • /
    • 제32권1A호
    • /
    • pp.91-100
    • /
    • 2007
  • 본 논문에서는 저출력 모바일 RFID 리더의 인식 거리를 확대시키기 위하여 20Watts 급의 전력 공급용 RF Shower 시스템을 개발하였으며, 실험을 통하여 Shower 시스템의 출력을 조절하면 리더-태그 간 인식거리가 3배 이상 늘어나는 것을 확인하였다. 향후 RF Shower 시스템을 이용하여 Shower Zone 설계를 적절히 함으로써 저출력 리더(20dBm이하)를 사용하면서 기존 RFID 시스템의 인식거리를 획기적으로 확장할 수 있을 것으로 기대된다.

저출력 RFID 시스템에서 인식거리 확대를 위한 전력 공급용 RF Shower 시스템 (A Study on the RF Shower System to Extend Interrogating Range for the Low Power RFID Reader System)

  • 정진욱;배재현;오하령;성영락;송호준;장병준;최경;이정석;이홍배;이학용;김종민;신재철;박준석
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제55권12호
    • /
    • pp.526-533
    • /
    • 2006
  • In this paper, we presented the synchronization module between RF shower system and RFID Reader to extend interrogating range on Mobile RFID system, Costas Loop and FPLL(Frequency/phase Lock Loop) were used. We achieved compromised range of 3MHz locking frequency, 1ms locking time and figured out remarkable Hopping frequency of the Reader. The prototype of the new designed RFID system has been tested with ISO18000-6 type-B Tag. The read range between designed RFID Reader and Tag has been measured, it increased triple times by adjusting the Shower system output level.

샤워형 초음파 장치를 이용한 농약 제거 효율에 관한 연구 (Study on the elimination of agricultural chemicals using shower type ultrasonic cleaner)

  • 조승인;허웅;김정국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.905-909
    • /
    • 2003
  • This paper describes a shower type ultrasonic cleaning system using particle acceleration, developed for better effectiveness in washing out agricultural chemicals from fruits or vegetables, compared to the existing bath type ultrasonic cleaning system. The shower type system consists of a signal generator, a transducer, and a spouting nozzle, mainly. The system has been tested based on the method recommended by Korea Food and Drug Administration. It is found that shower type system shows better performance and cost-effectiveness than the bath type system that is commercially available .

  • PDF

Case Study on Developing an Elderly Automatic Shower System

  • Kim, Jong-Hyun;Hong, Jae-Soo;Chun, Keyoung-Jin
    • 대한인간공학회지
    • /
    • 제30권5호
    • /
    • pp.629-636
    • /
    • 2011
  • Objective: The aim of this study is developing an elderly automatic showering system by optimizing nozzle position and angle of water injection on ergonomics approach. Background: The elderly living in nursing home or hospital were increased by an aging population. Helping the elderly on showering is so hard. In addition, the existing showering/bathing systems are not effective because shower pattern of the elderly and washed range of nozzle were not considered. Method: Firstly, basic specification were determined by anthropometric approach. Secondly, position of nozzle and angle of water injection were determined through observation of elderly behavior on showering. And, finally, they were optimized by washing test and showering simulation. Results: On showering importance of body parts were able to analysis through observation of elderly behavior. The position of nozzle and angle of water injection was able to optimize by showering simulation. The automatic showering system was developed by considering their results. Conclusion: The most important technology of developing a showering system is the determining position of nozzle and angle of water injection, number of nozzle. It was developed by applying its results through user centered-research. Application: The user centered-research of developing products was able to apply directly to develop automatic bath, showering products etc. Further more it was available to apply senior friendly products.

공동주택에서 미세먼지 저감을 위한 에어샤워 성능실험 (Experiment of Air-Shower to Reduce Particulate Matter in Apartment Housing)

  • 박진철;정홍구
    • 토지주택연구
    • /
    • 제12권2호
    • /
    • pp.91-97
    • /
    • 2021
  • 본 연구는 에어샤워 시스템의 가동에 따른 5종의 의류(Dress Suit, Hiking Clothes, Knit, Cotton T-Shirt, Coat)의 미세먼지의 제거성능을 파악하고자 한 것으로 그 연구결과를 요약하면 다음과 같다. 첫째, 에어샤워 시스템 가동 실험결과, 미세먼지 제거율은 1회 가동시에만 평균 59.4%가 제거 되고 있었다. 특히, 2회 및 3회 가동시에는 68.5%에서 최고 73.3% 까지 제거율을 나타내고 있었다. 둘째, 5종류의 의류종류별 제거율은 Dress Suit 74.0% > Hiking Clothes 70.6% > Knit 63.3% > Cotton T-Shirt 50.5% > Coat 38.8% 순으로 나타났다. 즉, 의류 종류에 따라 코트 등 털 소재의 의류는 정전기 등의 원인으로 미세먼지 제거율이 다른 소재에 비해 적게 나타났지만 보통 의류인 경우는 50% 이상의 제거율을 보이고 있었다.

Analysis on Muscle Activities in the Upper Body of Caregivers according to Drive-Assisting Speeds of a Shower Carrier

  • Ko, Cheol Woong;Cho, Deok Yeon;Bae, Tae Soo
    • 대한인간공학회지
    • /
    • 제32권5호
    • /
    • pp.437-442
    • /
    • 2013
  • Objective: The objective of this study was to investigate the effects of drive-assisting system in a shower carrier on the upper body muscle activities of caregivers through drivability tests. Background: In care facilities, one of the major ADL (Activities of Daily Living) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care facilities to reduce caregivers' muscle burden. In particular, it is desirable to utilize a shower carrier equipped with drive-assisting system to effectively care for the elderly. However, there were few systematic studies on the relationship between muscle activities and drive-assisting speeds. Method: For the drivability tests to study the effects on the muscle activities according to the drive-assisting speeds(corresponding drive-voltages: 0.0V, 2.0V, 2.1V, 2.3V), 6 females in their 40s($43{\pm}4yrs$, $157{\pm}5cm$, and $54.5{\pm}1.5kg$) were selected. To measure muscle activities of caregivers through drivability tests, 7 muscles in the upper body(TM/Trapezius Muscle, DM/Deltoid Muscle, BBM/Biceps Brachii Muscle, TBM/Triceps Brachii Muscle, ECRLM/Extensor Carpi Radialis Longus Muscle, FCUM/Flexor Carpi Ulnaris Muscle, and ESM/Erector Spinae Muscle) were selected. Results: In the TM, muscle activities were decreased as 21% compared to 0.0V, when drive-voltage 2.0V was applied, as 57% by 2.1V, and 62% by 2.3V(p<0.05), whereas 40%, 56%, and 69% of muscles activities were decreased respectively from the DM(p<0.05). Also, from the UL(BBM+TBM+ECRLM+FCUM), muscle activities were decreased by 17% with 2.0V as against 0.0V, by 47% with 2.1V, and 52% with 2.3V, whereas decreases in muscle activities from the ESM were found by 20%, 34%, and 42% respectively by 2.0V, 2.1V, and 2.3V(p<0.05). Conclusion: The muscle activities were decreased in the order of the DM, TM, ESM, and UL. As muscle activities were remarkably reduced as drive voltage were increased, it was expected to reduce the upper body muscle burden on the caregivers when using shower carriers equipped with driving-assist system. Applications: The results from this study can be applied for the development of a shower carrier including other equipment to possibly reduce the muscle burden of the caregivers.

Low temperature pulsed ion shower doping for poly-Si TFT on plastic

  • Kim, Jong-Man;Hong, Wan-Shick;Kim, Do-Young;Jung, Ji-Sim;Kwon, Jang-Yeon;Noguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.95-97
    • /
    • 2004
  • We studied a low temperature ion doping process for poly-Si Thin Film Transistor (TFT) on plastic substrates. The ion doping process was performed using an ion shower system, and subsequently, excimer laser annealing (ELA) was done for the activation. We have studied the crystallinity of Si surface at each step using UV-reflectance spectroscopy and the sheet resistance using 4-point probe. We found that the temperature has increased during ion shower doping for a-Si film and the activation has not been fulfilled stably because of the thermal damage against the plastic substrate. By trying newly a pulsed ion shower doping, the ion was efficiently incorporated into the a-Si film on plastic substrate. The sheet resistance decreased with the increase of the pulsed doping time, which was corresponded to the incorporated dose. Also we confirmed a relationship between the crystallinity and the sheet resistance. A sheet resistance of 300 ${\Omega}$/sq for the Si film of 50nm thickness was obtained with a good reproducibility. The ion shower technique is a promising doping technique for ultra low temperature poly-Si TFTs on plastic substrates as well as those on glass substrates.

  • PDF

유도결합 플라즈마 시스템의 수치 모델링에서 가스 분배 특성 해석 (Characterization of Gas Distribution Effect in Inductively Coupled Plasma System)

  • 주정훈
    • 한국표면공학회지
    • /
    • 제46권3호
    • /
    • pp.133-138
    • /
    • 2013
  • We have developed a 2D axi-symmetric numerical model for an inductively coupled plasma system in order to analyze gas mixing effect through a narrow gap shower head. For frictional flow, holes of 0.5 mm diameter and 2 mm length are approximately modeled in 2D. Gas velocity distribution 10 mm below the shower head showed 2 times difference between the center and the edge at 10 mTorr. At 10 mm above the wafer, it was increased to 6 times difference due to the pumping duct effect. The model with a 5 mm height buffer region of a shower head showed reasonable behavior of Ar discharge. The density of Ar metastable showed additional peak inside the buffer region around the edge holes.

6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제1보 실증실험) (Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 1: Verification Experiment))

  • 김진홍;김성수;최봉수;홍희기
    • 설비공학논문집
    • /
    • 제16권2호
    • /
    • pp.128-134
    • /
    • 2004
  • In order to verify and take measures against a variety of troubles which cannot be predicted in a well-controlled laboratory, it is necessary that solar system should be experimented in an actual situation during a long period. Through this experiment it can be also understood how the load pattern and operational conditions expected in a design process become different to those in the actual running, which can be applied to a new system design. We installed 6 kW solar hot water heating system with a shower facility and operated during 7 months. As a result, average 8.3 persons took a shower a day; solar fraction is 71% and total collector efficiency is 40% during the periods from March to September. We confirmed several troubles encountered in the actual situation and considered practical center-measures.