Browse > Article
http://dx.doi.org/10.5143/JESK.2013.32.5.437

Analysis on Muscle Activities in the Upper Body of Caregivers according to Drive-Assisting Speeds of a Shower Carrier  

Ko, Cheol Woong (Smart Welfare Technology R&D Group, Korea Institute of Industrial Technology (KITECH))
Cho, Deok Yeon (Research Coordination Team, Hyundai Sungwoo Automotive Co., Ltd.)
Bae, Tae Soo (Department of Biomedical Engineering, Jungwon University)
Publication Information
Journal of the Ergonomics Society of Korea / v.32, no.5, 2013 , pp. 437-442 More about this Journal
Abstract
Objective: The objective of this study was to investigate the effects of drive-assisting system in a shower carrier on the upper body muscle activities of caregivers through drivability tests. Background: In care facilities, one of the major ADL (Activities of Daily Living) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care facilities to reduce caregivers' muscle burden. In particular, it is desirable to utilize a shower carrier equipped with drive-assisting system to effectively care for the elderly. However, there were few systematic studies on the relationship between muscle activities and drive-assisting speeds. Method: For the drivability tests to study the effects on the muscle activities according to the drive-assisting speeds(corresponding drive-voltages: 0.0V, 2.0V, 2.1V, 2.3V), 6 females in their 40s($43{\pm}4yrs$, $157{\pm}5cm$, and $54.5{\pm}1.5kg$) were selected. To measure muscle activities of caregivers through drivability tests, 7 muscles in the upper body(TM/Trapezius Muscle, DM/Deltoid Muscle, BBM/Biceps Brachii Muscle, TBM/Triceps Brachii Muscle, ECRLM/Extensor Carpi Radialis Longus Muscle, FCUM/Flexor Carpi Ulnaris Muscle, and ESM/Erector Spinae Muscle) were selected. Results: In the TM, muscle activities were decreased as 21% compared to 0.0V, when drive-voltage 2.0V was applied, as 57% by 2.1V, and 62% by 2.3V(p<0.05), whereas 40%, 56%, and 69% of muscles activities were decreased respectively from the DM(p<0.05). Also, from the UL(BBM+TBM+ECRLM+FCUM), muscle activities were decreased by 17% with 2.0V as against 0.0V, by 47% with 2.1V, and 52% with 2.3V, whereas decreases in muscle activities from the ESM were found by 20%, 34%, and 42% respectively by 2.0V, 2.1V, and 2.3V(p<0.05). Conclusion: The muscle activities were decreased in the order of the DM, TM, ESM, and UL. As muscle activities were remarkably reduced as drive voltage were increased, it was expected to reduce the upper body muscle burden on the caregivers when using shower carriers equipped with driving-assist system. Applications: The results from this study can be applied for the development of a shower carrier including other equipment to possibly reduce the muscle burden of the caregivers.
Keywords
Aging; Shower carrier; Caregiver; Muscle burden; Drive-assisting system;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Cho, et al., "Development of a Shower Carrier based on the Needs in Long-term Care Institutions.", Journal of the Ergonomics Society of Korea, 31(2), 379-388, 2012.   과학기술학회마을   DOI   ScienceOn
2 Hur, et al. "Difference of Lumbar & Lower Extremity Muscle Activity when Patients are Transferred by Physical Therapists.", Journal of the Ergonomics Society of Korea, 30(5), 613-619, 2011.   과학기술학회마을   DOI   ScienceOn
3 iSTANDARD, http://www.istandard.or.kr
4 Kim, et al., "Effets on the Lumbar & Quadriceps Muscle Activity When Patients are Transferred by Physical Therapists.", Journal of the Ergonomics Society of Korea, 30(5), 613-619, 2011.   DOI   ScienceOn
5 National Statistical Office, 2010 Social Indicators in Korea, 2011.
6 SEED Technology Homepage, http://www.seedtech.co.kr
7 The Korean Gerontological Society, Understanding of Gerontology, Daeyoung Munhwa Publishing Co., pp. 142-143, 2002.