• Title/Summary/Keyword: Shower System

Search Result 50, Processing Time 0.027 seconds

A Study on the RF Shower System to Extend Interrogating Range on Mobile RFID Reader (모바일 RFID 시스템의 인식거리 확대를 위한 전력 공급용 RF Shower 시스템 개발)

  • Ahn, Si-Young;Kim, Yong-Taek;Bae, Sung-Woo;Nae, Kwan-Kyu;Roh, Hyoung-Hwan;Kim, Gi-Beom;Park, Jun-Seok;Cho, Hong-Goo;Oh, Ha-Ryoung;Seong, Yeong-Rak;Song, Ho-Jun;Jang, Byung-Jun;Lee, Jung-Suk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.1A
    • /
    • pp.91-100
    • /
    • 2007
  • This paper presents the RF Shower System for increased read range on low power mobile RFID System with 20watts of power supply. From the experiment, by controlling the output power of shower system, the tripled read range between reader and Tag is possibly discovered. Thus we can expect on the significantly widen read range of RFID system by appropriate control of Shower Zone, though we only with the reader with its lower output power level of 20dBm.

A Study on the RF Shower System to Extend Interrogating Range for the Low Power RFID Reader System (저출력 RFID 시스템에서 인식거리 확대를 위한 전력 공급용 RF Shower 시스템)

  • Jung, Jin-Wook;Bae, Jae-Hyun;Oh, Ha-Ryoung;Seong, Yeong-Rak;Song, Ho-Jun;Jang, Byeong-Jun;Choi, Kyung;Lee, Jung-Suk;Lee, Hong-Bae;Lee, Hak-Yong;Kim, Jong-Min;Shin, Jae-Cheol;Park, Jun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.12
    • /
    • pp.526-533
    • /
    • 2006
  • In this paper, we presented the synchronization module between RF shower system and RFID Reader to extend interrogating range on Mobile RFID system, Costas Loop and FPLL(Frequency/phase Lock Loop) were used. We achieved compromised range of 3MHz locking frequency, 1ms locking time and figured out remarkable Hopping frequency of the Reader. The prototype of the new designed RFID system has been tested with ISO18000-6 type-B Tag. The read range between designed RFID Reader and Tag has been measured, it increased triple times by adjusting the Shower system output level.

Study on the elimination of agricultural chemicals using shower type ultrasonic cleaner (샤워형 초음파 장치를 이용한 농약 제거 효율에 관한 연구)

  • Cho, Sheung-In;Hur, Woong;Kim, Jung-Kuk
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.905-909
    • /
    • 2003
  • This paper describes a shower type ultrasonic cleaning system using particle acceleration, developed for better effectiveness in washing out agricultural chemicals from fruits or vegetables, compared to the existing bath type ultrasonic cleaning system. The shower type system consists of a signal generator, a transducer, and a spouting nozzle, mainly. The system has been tested based on the method recommended by Korea Food and Drug Administration. It is found that shower type system shows better performance and cost-effectiveness than the bath type system that is commercially available .

  • PDF

Case Study on Developing an Elderly Automatic Shower System

  • Kim, Jong-Hyun;Hong, Jae-Soo;Chun, Keyoung-Jin
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.5
    • /
    • pp.629-636
    • /
    • 2011
  • Objective: The aim of this study is developing an elderly automatic showering system by optimizing nozzle position and angle of water injection on ergonomics approach. Background: The elderly living in nursing home or hospital were increased by an aging population. Helping the elderly on showering is so hard. In addition, the existing showering/bathing systems are not effective because shower pattern of the elderly and washed range of nozzle were not considered. Method: Firstly, basic specification were determined by anthropometric approach. Secondly, position of nozzle and angle of water injection were determined through observation of elderly behavior on showering. And, finally, they were optimized by washing test and showering simulation. Results: On showering importance of body parts were able to analysis through observation of elderly behavior. The position of nozzle and angle of water injection was able to optimize by showering simulation. The automatic showering system was developed by considering their results. Conclusion: The most important technology of developing a showering system is the determining position of nozzle and angle of water injection, number of nozzle. It was developed by applying its results through user centered-research. Application: The user centered-research of developing products was able to apply directly to develop automatic bath, showering products etc. Further more it was available to apply senior friendly products.

Experiment of Air-Shower to Reduce Particulate Matter in Apartment Housing (공동주택에서 미세먼지 저감을 위한 에어샤워 성능실험)

  • PARK, JIN CHUL;Chung, Hong Goo
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.91-97
    • /
    • 2021
  • High levels of fine dust is an increasing health concern in major cities such as Seoul. To improve the indoor air quality of apartments, this study examined the ability of an air shower system installed in an apartment unit to remove fine dust (as defined by ISO 12103-A2) from various clothing items of building occupants entering their apartment. Results of the experiment indicate that an air shower system is effective in removing final dust from clothing after one pass through the system. The fine dust removal efficiency for various clothing items was 74% for a dress suit, 70.6% for hiking clothes, 63.3% for knit-wear, 50.5% for a cotton t-shirt, and 38.8% for a coat. Fine dust removal efficiency increased with a second and third pass through the air shower system by an average of 9.1 and 13.9 percentage points respectively compared to a single pass through the system.

Analysis on Muscle Activities in the Upper Body of Caregivers according to Drive-Assisting Speeds of a Shower Carrier

  • Ko, Cheol Woong;Cho, Deok Yeon;Bae, Tae Soo
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.437-442
    • /
    • 2013
  • Objective: The objective of this study was to investigate the effects of drive-assisting system in a shower carrier on the upper body muscle activities of caregivers through drivability tests. Background: In care facilities, one of the major ADL (Activities of Daily Living) factors is bathing/showering. Recently, bath/shower-assisting equipment is actively being introduced in care facilities to reduce caregivers' muscle burden. In particular, it is desirable to utilize a shower carrier equipped with drive-assisting system to effectively care for the elderly. However, there were few systematic studies on the relationship between muscle activities and drive-assisting speeds. Method: For the drivability tests to study the effects on the muscle activities according to the drive-assisting speeds(corresponding drive-voltages: 0.0V, 2.0V, 2.1V, 2.3V), 6 females in their 40s($43{\pm}4yrs$, $157{\pm}5cm$, and $54.5{\pm}1.5kg$) were selected. To measure muscle activities of caregivers through drivability tests, 7 muscles in the upper body(TM/Trapezius Muscle, DM/Deltoid Muscle, BBM/Biceps Brachii Muscle, TBM/Triceps Brachii Muscle, ECRLM/Extensor Carpi Radialis Longus Muscle, FCUM/Flexor Carpi Ulnaris Muscle, and ESM/Erector Spinae Muscle) were selected. Results: In the TM, muscle activities were decreased as 21% compared to 0.0V, when drive-voltage 2.0V was applied, as 57% by 2.1V, and 62% by 2.3V(p<0.05), whereas 40%, 56%, and 69% of muscles activities were decreased respectively from the DM(p<0.05). Also, from the UL(BBM+TBM+ECRLM+FCUM), muscle activities were decreased by 17% with 2.0V as against 0.0V, by 47% with 2.1V, and 52% with 2.3V, whereas decreases in muscle activities from the ESM were found by 20%, 34%, and 42% respectively by 2.0V, 2.1V, and 2.3V(p<0.05). Conclusion: The muscle activities were decreased in the order of the DM, TM, ESM, and UL. As muscle activities were remarkably reduced as drive voltage were increased, it was expected to reduce the upper body muscle burden on the caregivers when using shower carriers equipped with driving-assist system. Applications: The results from this study can be applied for the development of a shower carrier including other equipment to possibly reduce the muscle burden of the caregivers.

Low temperature pulsed ion shower doping for poly-Si TFT on plastic

  • Kim, Jong-Man;Hong, Wan-Shick;Kim, Do-Young;Jung, Ji-Sim;Kwon, Jang-Yeon;Noguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.95-97
    • /
    • 2004
  • We studied a low temperature ion doping process for poly-Si Thin Film Transistor (TFT) on plastic substrates. The ion doping process was performed using an ion shower system, and subsequently, excimer laser annealing (ELA) was done for the activation. We have studied the crystallinity of Si surface at each step using UV-reflectance spectroscopy and the sheet resistance using 4-point probe. We found that the temperature has increased during ion shower doping for a-Si film and the activation has not been fulfilled stably because of the thermal damage against the plastic substrate. By trying newly a pulsed ion shower doping, the ion was efficiently incorporated into the a-Si film on plastic substrate. The sheet resistance decreased with the increase of the pulsed doping time, which was corresponded to the incorporated dose. Also we confirmed a relationship between the crystallinity and the sheet resistance. A sheet resistance of 300 ${\Omega}$/sq for the Si film of 50nm thickness was obtained with a good reproducibility. The ion shower technique is a promising doping technique for ultra low temperature poly-Si TFTs on plastic substrates as well as those on glass substrates.

  • PDF

Characterization of Gas Distribution Effect in Inductively Coupled Plasma System (유도결합 플라즈마 시스템의 수치 모델링에서 가스 분배 특성 해석)

  • Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.3
    • /
    • pp.133-138
    • /
    • 2013
  • We have developed a 2D axi-symmetric numerical model for an inductively coupled plasma system in order to analyze gas mixing effect through a narrow gap shower head. For frictional flow, holes of 0.5 mm diameter and 2 mm length are approximately modeled in 2D. Gas velocity distribution 10 mm below the shower head showed 2 times difference between the center and the edge at 10 mTorr. At 10 mm above the wafer, it was increased to 6 times difference due to the pumping duct effect. The model with a 5 mm height buffer region of a shower head showed reasonable behavior of Ar discharge. The density of Ar metastable showed additional peak inside the buffer region around the edge holes.

Verification Experiment and Analysis for 6 kW Solar Water Heating System(Part 1: Verification Experiment) (6kW급 태양열 온수급탕 시스템의 실증실험 및 분석(제1보 실증실험))

  • 김진홍;김성수;최봉수;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.2
    • /
    • pp.128-134
    • /
    • 2004
  • In order to verify and take measures against a variety of troubles which cannot be predicted in a well-controlled laboratory, it is necessary that solar system should be experimented in an actual situation during a long period. Through this experiment it can be also understood how the load pattern and operational conditions expected in a design process become different to those in the actual running, which can be applied to a new system design. We installed 6 kW solar hot water heating system with a shower facility and operated during 7 months. As a result, average 8.3 persons took a shower a day; solar fraction is 71% and total collector efficiency is 40% during the periods from March to September. We confirmed several troubles encountered in the actual situation and considered practical center-measures.