• 제목/요약/키워드: Shoulder abduction

검색결과 316건 처리시간 0.03초

유방암 수술 후 방사선치료중인 환자를 위한 운동프로그램이 심폐기능 및 어깨관절기능에 미치는 효과 (Effects of Exercise on Cardiopulmonary Functions and Shoulder Joint Functioning in Breast Cancer Patients undergoing Radiation Therapy after Breast Surgery)

  • 채영란;최명애
    • 대한간호학회지
    • /
    • 제31권3호
    • /
    • pp.454-466
    • /
    • 2001
  • Purpose: The purpose of this study was to determine the effects of exercise program on cardiopulmonary functions and shoulder joint functioning in breast cancer patients who under- went radiation therapy after surgery. Method: Subjects in the experimental group(N=12) participated in an exercise program for eight weeks. The Exercise program consisted of shoulder stretching, arm weight training, and walking on treadmill. Maximal oxygen uptake (v2max), maximal running time, shoulder joint range of motion, and shoulder functional assessment were determined before and after the exercise program. Baseline sociodemographic and medical data were compared between experimental group and control group using the Fisher's exact test and Mann- Whitney U test. For effects of the exercise program, repeated measures ANOVA were used. Result: 1) Following the exercise program for eight weeks, both v$\alpha$ max and maximal running time tended to increase in experimental group comparing with the control group. 2) Shoulder abduction, extension and flexion of the operated upper extremity in the experimental group comparing with control significantly increased after the exercise program(p<0.05). 3) Shoulder flexion of the normal upper extremity in the experimental group comparing with control significantly increased after the exercise program(p<0.05). Conclusion: The results suggest that the exercise program for breast cancer patients undergoing radiation therapy after breast surgery can improve shoulder functions and increase cardiopulmonary functions, which are maximal oxygen uptake and maximal running time.

  • PDF

견관절 전방 통증 환자에서 초음파 유도하 견쇄관절 소염약침요법 병행 치료의 효과: 후향적 연구 (The Effectiveness of Ultrasound-Guided Soyeom Pharmacopuncture Therapy at Acromioclavicular Joint of Shoulder in Patients with Anterior Shoulder Pain: A Retrospective Study)

  • 김상우;전동휘;김병준;박정욱;오민석
    • 한방재활의학과학회지
    • /
    • 제31권3호
    • /
    • pp.95-104
    • /
    • 2021
  • Objectives The purpose of this study was to observe effectiveness of ultrasound-guided Soyeom pharmacopuncture therapy at acromioclavicular joint of shoulder in patients with anterior shoulder pain. Methods We analyzed medical records of 9 patients hospitalized with anterior shoulder pain who had admitted to Department of Korean Rehabilitation Medicine, College of Korean Medicine, Daejeon University from March 1, 2021 to June 13, 2021. 9 patients were treated the treatment of Soyeom pharmacopuncture therapy on acromioclavicular joint under ultrasonic guidance with Korean medicine treatment (such as herbal medicine, acupuncture, moxabustion, etc). The study was conducted as a retrospective observation study which analyze the patient's medical records. We used numeric rating scale (NRS) to evaluate pain reduction and the shoulder range of motion (ROM) to evaluate function improvement twice (before pharmacopuncture treatment and 5 days later treatment). Statistical analysis was performed using the IBM SPSS Statistics version 25 program (IBM Co., Armonk, NY, USA). Results The average of numeric rating scale reduced statistically significantly from 5.56±1.13 to 3.11±1.36 (p=0.004). The average of shoulder flexion ROM increased statistically significantly from 166.67±8.17° to 175.00±8.37° (p<0.05). And the average of shoulder abduction ROM increased statistically significantly from 158.57±20.35° to 172.86±12.53° (p<0.05). Both NRS and shouler ROM showed statistically significantly improve after treatment. Conclusions This study shows ultrasound-guided Soyeom pharmacopuncture therapy at acromioclavicular joint of shoulder has a meaningful clinical effect on the improving shoulder pain and ROM especially on flexion and abduction.

수축 형태에 따른 20대 대학생의 우세 측과 비우세 측의 근력비교 (Comparison of Muscle Strength between Dominant and Non-dominant Sides of College Students in Their 20s according to Contraction Type)

  • 이종협;이승규;나영선;전정우;유재호;홍지헌;김진섭;이동엽
    • 대한통합의학회지
    • /
    • 제12권2호
    • /
    • pp.47-53
    • /
    • 2024
  • Purpose : This study investigated the effects of concentric and eccentric contractions on muscle strength using an isokinetic dynamometer (ID) in college students in their 20s. It aimed to understand the impact of differences between the dominant and non-dominant sides on strength asymmetry and to elucidate the clinical implications of these differences to establish an appropriate posture and environment for patients. Methods : The experiment was conducted with 30 healthy adult participants. Prior to the experiment, participants underwent a warm-up targeting the shoulders, and efforts were made to eliminate factors that could potentially influence the measurement results. Subsequently, the maximum safe range of motion of shoulder joint abduction, extension, and flexion was measured using an isokinetic muscle function testing device. Muscle strength was assessed using concentric and eccentric contractions alternating between the dominant and non-dominant sides, and paired sample t-tests were used for the analysis. Results : There was no significant difference between bilateral peak torques for eccentric contraction in shoulder joint abduction, extension, and flexion (p>0.05). There was also no significant difference between bilateral peak torques for concentric contraction in shoulder joint abduction, extension and flexion (p>0.05). Conclusion : This study found no statistically significant difference in muscle strength between the dominant and non-dominant sides during concentric and eccentric contractions. However, previous studies have shown significant differences between the dominant and non-dominant sides during eccentric and concentric contractions during internal shoulder rotation in the general population, as well as significant differences in the upper trapezius muscle. Therefore, further research is needed to support the application of different intensities for bilateral muscle strengthening exercises in clinical practice.

전방 급성 견열손상 후 발생한 변형된 SLAP Ⅱ손상과 전방 관절순 파열 -증례 보고 1 례- (Possible Development of Modified SLAP Ⅱ and Bankart Lesion After Shoulder Avulsion injury -A Case Report-)

  • 유재철;곽호윤;황승근
    • Clinics in Shoulder and Elbow
    • /
    • 제7권1호
    • /
    • pp.10-13
    • /
    • 2004
  • Superior labrum anterior to posterior (SLAP) lesions of the shoulder has recently been a popular issue to shoulder surgeons. Now we are correlating many shoulder symptoms to this SLAP lesion. A 45 year-old female patient injured her shoulder when her arm sleeve was entrapped in moving automobile door. A forceful pull of the arm in external and abduction position was suspected. She complained continuous shoulder pain with limited range of motion for 2 months. Magnetic resonance image showed possible SLAP lesion but no definite diagnosis were made prior to the operation. Arthroscopic evaluation revealed SLAP type Ⅱ lesion with concomitant avulsion of the superior glenoid cartilage. In addition anterior labrocapsular tear was seen from 7 to 9 o'clock of anterior glenoid. The SLAP lesion and the anterior capsulolabral lesion were repaired properly to the glenoid. We report a case of glenoid-cartilage avulsion type of SLAP Ⅱwith anterior labrocapsular lesion.

측각기를 사용한 견관절 운동범위 측정의 신뢰도에 관한 연구 (Reliaility of Goniometric Measurements of Shoulder Joint Range of Motion)

  • 이소준;허영구
    • 대한물리치료과학회지
    • /
    • 제8권1호
    • /
    • pp.917-921
    • /
    • 2001
  • The purpose of this study was to examine the difference in measurements of passive range of motion(PROM) of shoulder when motions are assessed in sitting, as compared with supine and the intratester and intertester reliabilities for goniometric measurements of shoulder PROM using two different sizes of goniometers. * A thesis submitted to the committee of Graduate School of Public Health, Chungnam National University in partial fulfillment of the requirements for the degree of Master of Public Health conferred in February 2001. Fifty one adult male subjects were measured three times, in random order, for the six shoulder motions(flexion, extension, abduction, adduction, external rotation, and internal rotation) while sitting and supine by three different therapists. Data were analyzed to determine intraclass correlation coefficients (ICCs) and paired "t" values between trials for measurements with different goniometer and betweensitting and supine trials. There was statistical difference in measurement of shoulder motion between supine and sitting position and no statistical difference in goniometric type. The intratester intraclass correlation coefficients (ICCs) for all motions ranged from .87 to .98. The ICCs for the intertester reliability of PROM measurements of all shoulder motion ranged from .26 to .89. These findings suggest that reliable measures of PROM of the shoulder can be obtained using standard goniometry in a proper position.

  • PDF

Effects of 6 Week Kinesiotaping and Extracorporeal Shock Wave Therapy on the Joint Range of Motion in Patients with Frozen Shoulder

  • Choi, Jung Hyun;Kim, Soon Hee;An, Ho Jung;Koo, Ja Pung;Kim, Nyeon Jun
    • 국제물리치료학회지
    • /
    • 제8권1호
    • /
    • pp.1095-1099
    • /
    • 2017
  • This study used both kinesiotaping and extracorporeal shock wave therapy on patients diagnosed with frozen shoulder - a common musculoskeletal disorder in adults - in order to observe the effects on the joint range of motion. 21 adult(male 12, female 9) were selected and distributed into randomized groups. One group received kinesiotaping (n=10) and the other group received kinesiotaping together with extracorporeal shockwave therapy (n=11). After a 6 week duration of receiving kinesiotaping and extracorporeal shockwave therapy, changes in the joint range of motion in the patients were observed. Post-treatment of frozen shoulder, the changes in abduction within the shoulder joint were as follows: in both groups there was a noticeable increase in the joint range of motion (p<.05). Post-treatment of frozen shoulder, the changes in external rotation within the shoulder joint were as follows: both groups showed a significant increase in the joint range of motion (p<.05). The result of suggest that, it can be inferred that both the extracorporeal shockwave therapy and kinesiotaping are effective in increasing the joint range of motion in patients with frozen shoulder.

노인의 견관절 가동범위에 관한 연구 (A Study on Shoulder Joint ROM of the Elderly)

  • 엄기매;양윤권
    • 대한물리치료과학회지
    • /
    • 제8권2호
    • /
    • pp.997-1003
    • /
    • 2001
  • The purpose of this study is to know the average of pint range of motion and difference according to the aging for the elderly, This study consisted of elder male(n=75) and elder female(n=l09), The result of assessment and analysis in shoulder pint range of motion are as follows: 1) The average shoulder flexion pint range of motion in 60-69(from sixty to sixty-nine)years old are 163.04(Left-Male), 162.91(Right-Male), 158.74 (Left-Female), 158.74 (Right-Female). 70-79years old are 149.40(L-M), 152.38(R-M), 153,37(L-F), 153.37(R-F). 80-89 years old are 149.57(L-M), 147.93(R-M), 151.17(L-F), 150.33(R-F). There was no significant difference among group, 2) The average shoulder extension pint range of motion in 60-69years old are 48.15(L-M), 47.20(R-M), 45.16(L-F), 44.23(R-F), 70-79years old are 37.l1(L-M), 38.70(R-M), 35.17(L-F), 36.71(R-F), 80-89 years old are 34.46(L-M). 36.71(R-M), 33.90(L-F), 33.09(R-F). There was significant difference among group(p<.05). 3) The average shoulder abduction pint range of motion in 60-69years old are 164.22(L-M), 165.96(R-M), 159.34(L-F), 159.97(R-F), 70-79years old are 152.27(L-M), 155.05(R-M), 152.32(L-F), 53.66(R-F), 80-89 years old are 152.17(L-M), 153.76(R-M), 147.53(L-F), 147.37(R-F). There was significant difference in right shoulder abduction among group(p<05). 4) The average shoulder internal rotation pint range of motion in 60-69years old are 63.52(L-M), 65.70(R-M), 64.16(L-F), 64.61(R-F), 70-79years old are 64.50(L-M), 65.81(R-M) 61.10(L-F), 61.83(R-F). 80-89 years old are 61.60(L-M), 61.66(R-M), 57.53(L-F), 57.53(R-F). There was no significant difference among group. 5) The average shoulder external rotation pint range of motion in 60-69years old are 50.87(L-M), 50.22(R-M), 51.03(L-F), 50.42(R-F), 70-79years old are 50.91(L-M), 50.20(R-M) 48.37(L-F), 50.20(R-F). 80-89 years old are 46.83(L-M), 47.93(R-M), 43.43(L-F), 43.72(R-F).There was significant difference in left shoulder external rotation among group(p<.05).

  • PDF

Isokinetic Muscle Strength and Muscle Endurance by the Types and Size of Rotator Cuff Tear in Men

  • Kim, In Bo;Kim, Do Keun
    • Clinics in Shoulder and Elbow
    • /
    • 제17권4호
    • /
    • pp.166-174
    • /
    • 2014
  • Background: Our study was to determine the effect on shoulder isokinetic muscle strength and muscle endurance in isolated full-thickness supraspinatus tendon tear and combined other rotator cuff tear. Methods: Total of 81 male patients (mean age $57.8{\pm}7.4$ years) who were diagnosed as a full-thickness supraspinatus tendon tear were included. They were classified into isolated or combined tear. The isokinetic muscle strength and muscle endurance were measured using the Biodex multi-joint system $PRO^{(R)}$ (Biodex Medical Systems, Shirley, NY, USA) in following movements: shoulder abduction, adduction, flexion, extension, external rotation, and internal rotation. Then, the difference in muscle function according to the type of tears were assessed. Fifty-seven patients had isolated supraspinatus tendon (mean age $56.9{\pm}7.3$ years). They were classified into either anteroposterior tear or modified mediolateral tear. The size were measured using T2-weighted magnetic resonance imaging scans in sagittal plane. Results: Between subjects categorized into the type of tear, we found significant inter-categorical differences in isokinetic muscle strength during abduction, adduction, flexion, extension, and internal rotation, and in muscle endurance during flexion, extension, and internal rotation. Anteroposterior diameter tear, we did not show significant differences in either isokinetic muscle strength or muscle endurance during any movements. However, with modified mediolateral diameter, we found significant differences with isokinetic muscle strength during adduction, and in muscle endurance the external rotation and internal rotation. Conclusions: We found that a supraspinatus tendon tear associated with more numbers of rotator cuff tears has lower isokinetic muscle strength and muscle endurance than a tear found alone.

Clinical and Radiological Outcome after Surgical Treatment in Displaced Clavicular Midshaft Fracture

  • Gwak, Heui-Chul;Kim, Jung-Han
    • Clinics in Shoulder and Elbow
    • /
    • 제19권2호
    • /
    • pp.73-77
    • /
    • 2016
  • Background: The first purpose of this study is to compare the clinical and radiological outcomes of surgical treatment for displaced midshaft clavicle fracture (Robinson type 2B1 vs. 2B2) with 3.5-mm low profile clavicular locking compression plate. The second purpose is to evaluate the difference of the results depending on the presence of accompanying injuries. Methods: Forty-nine patients who underwent an operation for the fractures were reviewed retrospectively. Fracture patterns were classified according to group 2B1 and 2B2 using Robinson's classification. For radiological outcome, time to union after operation was evaluated and for clinical outcome, American Shoulder and Elbow Society (ASES) score, University of California in Los Angeles (UCLA) score, visual analogue scale (VAS), and range of motion (ROM) were evaluated from preoperative period to last follow-up period. Results: The mean time for union was not significantly different in the 2B1 group and 2B2 group (p=0.062). No statistically significant difference in ASES score, UCLA score, and VAS was observed between 2B1 and 2B2 (p=0.619, p=0.896, p=0.856, respectively). In ROM, significant higher mean forward flexion and abduction was observed in 2B2 (p=0.025, p=0.017, respectively) and there was no difference in external rotation and external rotation at shoulder $90^{\circ}$ abduction position (p=0.130, p=0.180, respectively). There was no significant difference in clinical outcomes according to the accompanying injuries. Conclusions: There was no difference in clinical and radiological outcome between Robinson 2B1 and 2B2 type fracture after the operation. Accompanying injuries may not affect the clinical result of displaced midshaft clavicle fractures.