디스플레이용 스위칭모드 전원장치의 단락 고장분석 검출기법 (Techniques to Diagnose Short-Circuit Faults in the Switching Mode Power Supply for Display)

  • 이재원;전태원
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1186-1192
    • /
    • 2016
  • This paper proposes techniques to diagnose short-circuit faults of both the diodes and power FET in switching mode power supply (SMPS) by using a simple analog tester. The diodes in full-bridge rectifier, power FET, switching transformer, and some sensors are modelled with resistor. The total resistance value measured at the input terminal of a SMPS is analyzed when the short-circuit faults of diodes in a full bridge rectifier or power FET are occurred. The short-circuit faults of one or two diodes in a full bridge rectifier, power FET, and both the diodes in a full bridge rectifier and power FET can be detected by a range of total resistance, which is measured by the analog tester. Through experiments, the theoretical analysis for total resistance under short-circuit faults can be verified.

보조전원장치의 단락부하 차단기 개방을 위한 제어방법 (Control Method for Cut-out of Shorted Load in the Auxiliary Power Supply)

  • 황광철;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.249-254
    • /
    • 1998
  • This paper describes the control methods to cut out the NFB(No Fuse Breaker) of shorted load in the auxiliary power supply, Generally, when the short-circuit occurs in the load of the auxiliary power supply, the auxiliary power supply stops the operation according to the protection sequence. Finally, the other auxiliary power supply stops the operation by the same fault, To resolve this problem, we suggest the control method to trip the NFB of shorted load. That is, when the short circuit occurs, the controller changes control mode from voltage mode to current mode without the operation of output contactor(SIVK) in the auxiliary power supply. The auxiliary power supply provides a large current for the short-circuit load. After some time, the NFB of the short-circuit load is cut off and the auxiliary power supply Provides stable voltage for the loads except for the short-circuit load.

  • PDF

Weld Quality Assessment Method for Short-Circuit Mode in GMAW

  • Kim, J.M.;Yoo, C.D.
    • International Journal of Korean Welding Society
    • /
    • 제1권2호
    • /
    • pp.1-6
    • /
    • 2001
  • A weld quality assessment method is proposed in this work, which can be applied to the short-circuit mode in GMAW. Information about the welding signal trajectory, distribution of the signal duration at each sub-regions and short-circuit frequency is used to evaluate the weld quality. The weighted penalty, which is determined experimentally, is imposed for each abnormal signal. Performance of the proposed method is compared with the Simpson's method under the conditions of shielding gas reduction, workpiece surface contamination and joint gap in the butt and fillet welds. Although the proposed method predicts the weld quality with reasonable accuracy, further modification and extension to other metal transfer modes are needed as a further study.

  • PDF

$CO_2$ 용접의 단락이행 조건에서 스패터 발생과 파형인자와의 관계 (Relation between Spatter Generation and Waveform factor of $CO_2$ Welding in Short-Circuit Condition)

  • 김희진;강봉용;이강희;유중돈
    • Journal of Welding and Joining
    • /
    • 제16권3호
    • /
    • pp.95-101
    • /
    • 1998
  • Waveforms of $CO_2$ gas shielded arc welding in short circuit transfer mode was studied with the waveform analysis program, which can calculate various waveform factors such as number of short circuit event, mean and standard deviation of short circuit time and arc time. The calculated values of these factors were correlated independently or in combination with the spatter generation rate to figure out the most reliable index for evaluating spatter generation and further for arc stability. As a result this study, it was confirmed that the spatter generation tends to decrease with the increase of short circuit frequency. Further to this, it was also found that as the short circuit frequency increases the short circuit event becomes more uniform resulting in the decrease of standard deviations ($\sigma$values) of short circuit time and arc time. This result demonstrated that these factors are strongly correlated with each other and thus any one of these factors can be used for the evaluation index. In the discussion, however, short circuit frequency was proposed for the most practical index in evaluating the arc stability of short circuit transfer mode since it is the one which could be monitored in-process condition without any complex caculation process.

  • PDF

$CO_2$ 용접의 천이이행 조건에서 스패터 발생과 파형인자와의 관계 (Relationship between Spatter Generation and Waveform Factors in Transitional Condition of $CO_2$ Welding)

  • 강봉용;이창한;김희진;장희석
    • Journal of Welding and Joining
    • /
    • 제16권4호
    • /
    • pp.39-46
    • /
    • 1998
  • $CO_2$ gas shielded arc welding has been characterized with its harsh arc compared to Ar-based shielding gases and with its high level of spattere specially in welding current range of 250~300 amperes. In this range of welding current, the metal transfer mode showed to be changed from short circuit to globular with the increase of welding voltage resulting in so-called the transitional mode in which both modes of transfer appeared together. To characterize the transitional mode, the short circuit events were divided into two groups, i.e. normal short circuit (N.S.C) which has short circuit time $(t_s)$ over 2msec and instantaneous short circuit (I.S.C) of $t_s$$\leq$2msec. The experimental results showed that the number of N.S.C decreased almost linearly with the increase of welding voltage and appeared to be not related with spatter generation rate. However I.S.C became to be pronounced in the transitional condition and its number reached the maximum value at around 29.0 volts. Considering the relation with the spatter generation rate, it was found that the number of I.S.C had a very strong correlation with the spatter generation rate of the transitional condition. It was further demonstrated that spatter generation rate decreased quite linearly with the decrease of I.S.C frequency. It implies that I.S.C is the most important waveform factor controlling the spatter generation of the transitional mode, i.e. in the middle range of welding current. Based on these results, It was discussed that in the transitional mode the basic concept of waveform control for suppressing spatter generation would be different from the one applied for typical short circuit transfer mode of low welding current.

  • PDF

$CO_2$ 용접의 스패터 발생에 미치는 용적이행 모드의 영향 (Effect of Metal Transfer Mode on Spatter Generation of $CO_2$ Welding)

  • 강봉용;김희진
    • Journal of Welding and Joining
    • /
    • 제15권2호
    • /
    • pp.72-80
    • /
    • 1997
  • The spatter generation rate of GMA welding with $CO_2$ gas shielding was measured with the change of welding conditions such as wire feeding rate and welding voltage and then the results were analized with the accompanying changes in metal transfer mode and in bead geometry. The spatter generation rate (SGR) was relatively low not only wit the short circuit transfer but with the truely globular transfer mode. However, the SGR resulted with the mixed mode were consistantly high. The resultant wave pattern of mixed mode was due to the coexistance of short-circuit and globular transfer and characterized by the frequent appearance of instantaneous short circuit. Considering the result of SGR and that of bead geometry, it could be concluded that when the wire feeding rate (or welding current) was either low or high, the optimum bead shape could be obtained along with the low spatter generation. However, in the middle range of wire feeding rate, the optimum bead shape was only obtained in the mixed mode condition resulting in the high spatter generation.

  • PDF

VOF 방법을 이용한 GMA 용접의 금속 이행에 관한 동적 해석 (II) - 단락 이행 모드의 해석 - (Dynamic Analysis of Metal Transfer using VOF Method in GMAW (II) - Short Circuit Transfer Mode -)

  • 최상균;고성훈;유중돈;김희진
    • Journal of Welding and Joining
    • /
    • 제15권3호
    • /
    • pp.47-55
    • /
    • 1997
  • Dynamic characteristics of the short circuit mode are investigated using the Volume of Fluid (VOF) method. When the initial molten drop volume, contact area and wire feed rate are given, rate change of the molten bridge profiles, pressure and velocity distributions are predicted. The electromagnetic force with proper boundary conditions are included in the formulation to consider the effects of welding current. It is found that the molten metal is transferred to the weld pool mainly due to the pressure difference caused by the curvatures in the initial stage, and electromagnetic force becomes dominant factor in the final stage of short circuit transfer. Necking occurs at the contact position between the molten drop and weld pool, and the initial molten drop volume and welding current have significant effects on break-up time.

  • PDF

GMA용접에 있어서 스패터 발생에 미치는 와이어 탈산원소의 영향 (The Effect of Deoxidizers in a Wire on Spatter Generation in Gas Metal Arc Welding)

  • 방국수;안영호
    • Journal of Welding and Joining
    • /
    • 제14권5호
    • /
    • pp.145-150
    • /
    • 1996
  • The variation of spatter generation in gas metal arc welding with welding conditions and wire compositions was investigated and interpreted in terms of arc stability. The transition range from a short circuit mode to a spray mode in the mixed gas welding showed an unstable arc and generated the largest amount of spatters. Titanium reduced spatters only in the globular mode of $CO_2$welding and silicon and manganese showed the same effect The effect of silicon and manganese, however, was no longer seen when titanium was added simultaneously to the wire. It is believed that deoxidizers easily form oxides on the anode and make the arc stable even in DCRP welding. The wires with deoxidizers also showed low short circuit frequency, resulting in the increase of large size spatters.

  • PDF

6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험 (Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF

버스트 모드 광 신호 수신을 위한 자동 이득제어 회로 (An Automatic Gain Control Circuit for Burst-mode Optical Signal reception)

  • 기현철
    • 대한전자공학회논문지SD
    • /
    • 제40권12호
    • /
    • pp.31-38
    • /
    • 2003
  • 본 논문에서는 클리퍼(clipper)의 고속 동작 특성을 활용하여 자동 이득제어 회로의 정착시간(settling time)을 극히 짧게 구현할 수 있는 새로운 구조의 자동 이득제어 회로를 제안하였다. 제안한 자동 이득제어 회로에 대해서 해석적으로. 동작특성을 분석했다. 아울러 상용 파운드리(foundry)를 이용하여 1.2Gbps EPON 시스템용 버스트 모드 전치증폭회로를 설계하여 그 특성을 해석 결과와 비교 검증했다. 설계된 회로의 특성은 해석 결과와 잘 일치했으며 1㎱ 이하의 극히 짧은 정착시간(settling time)이 구현되고 있음을 확인 할 수 있었다