• Title/Summary/Keyword: Short case test

Search Result 351, Processing Time 0.024 seconds

Study on the Explosion and Fire Risks of Lithium Batteries Due to High Temperature and Short Circuit Current (고온 및 단락전류에 따른 리튬배터리의 폭발 및 화재 위험성에 관한 연구)

  • Sim, Sang-Bo;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.114-122
    • /
    • 2016
  • This study is to analyze the explosion and fire risks due to high temperature and short circuit current of Lithium batteries. This study selected the typical types of Li-polymer batteries and Li-ion batteries as the test samples. The result of explosion risk assessment due to the high temperature showed that, while a Li-polymer battery had $170^{\circ}C$ explosion on average, a Li-ion battery had $187^{\circ}C$ explosion. The measurement result of temperature increase due to short circuit current revealed that, in case that protection circuit module (PCM) was normally working, there was little of temperature increase due to over-current limitation. However, in case that PCM was out of order, the temperature of a Li-polymer battery increased up to an average of $115.7^{\circ}C$ and the temperature of a Li-ion battery increased up to an average of $80.5^{\circ}C$, which showed the higher risks of fire and burn.

Review about test method for the full-insulation verification of circuit breaker rated on 800kV, 50kA (800kV, 50kA 차단기의 전절연 검증을 위한 시험방법 검토)

  • Park, Seung-Jae;Suh, Yoon-Taek;Yoon, Hack-Dong;Kim, Yong-Sik;Kim, Maeng-Hyun;Koh, Heui-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.569-571
    • /
    • 2005
  • In case of dead-tank circuit breaker with the earthed enclosure, the dielectric performance for phase to ground should be verified under the hot-gas condition produced by the current interruption. This test condition is required in breaking test duties with the rated short-circuit current and rated voltage. And, KERI has completed the reinforcement of the synthetic testing facilities and these facilities have the testing capacity which enables the full-pole testing for 800kV circuit breaker by adopting the series voltage injection method. So, this paper introduced the test circuit and procedures about the full-pole and the multi-part testing method which was devised to estimate the full -insulation of phase-to-ground for the multi-pole and dead-tank circuit breaker.

  • PDF

A Study on Correlation between Height Growth, Obesity and Bone maturity in Childhood (소아기에 있어 키성장과 비만도, 골성숙도와의 상관성 연구)

  • CHoi, Sang Rak;Kim, Yun Young;Jang, Eun Jin;Koo, Jin Suk
    • The Journal of Korean Medicine
    • /
    • v.40 no.1
    • /
    • pp.24-33
    • /
    • 2019
  • Objectives: The purpose of this study is to analyze the causes of short stature through a clinical review of factors related to childhood height growth. So we can find the way to meet the needs of the heightism which is widely spread among modern people. Methods: Among 160 patients who came to Andong B oriental clinic for the purpose of growth therapy, 112 children whose height was smaller than other normal children were analyzed. When the children first came to the clinic, we checked their height and weight. The parents' height was recorded through a questionnaire. The relationship between obesity index and height growth was examined through growth plate test and Inbody test. We want to identify the genetic factors related to parental factors based on the data of the parent height. Results: For short stature children, weight was often normal or low. When we examined the relationship between parental genetic factors and child growth, we found that they were more influenced by father's height rather than mother's. We investigated the correlation between skeletal maturity and the five viscera. There was no apparent correlation between skeletal maturity and the five viscera but we found that there was some degree of relevance. Conclusions: For short stature children, the weight was often normal or low and parental genetic factors were more influenced by father than by mother. In the case of bone maturity it did not show a direct correlation between the five viscera.

A Study on the Fire Cause Analysis of Motor Damage (전동기 소손에 대한 화재 원인 분석에 관한 연구)

  • Lee, Chun-Ha;Ok, Kyung-Jae;Kwon, Byung-Duck
    • Fire Science and Engineering
    • /
    • v.21 no.4
    • /
    • pp.59-64
    • /
    • 2007
  • We studied on the fires about the electrical motors in this paper. We compared and analyzed about the transformation and damage state of single-phase induction motors used in the home appliances when we applied electrical overload and exterior flame. This experiment was progressed by the electrical overload application test and the exterior flame application test through the locked rotor of motor. In case of the exterior flame application test, it is divided into the apply voltage case and not apply voltage case. The result of an experiment through the locked rotor of motor, it was able to observe the short-circuit marks between layers at the winding coil parts, and it was appeared a transformed dendritic tissue structure of winding coil by the electrical overload test. The application voltage and the application exterior flame, it was confirmed that the stator winding coil parts were remain original shapes and observed that the color of the winding coil's circumference was changed to red. The non-application voltage and the application exterior flame, it was observed that the stator winding coil parts were transformed quite from original shapes. It was observed that the color of the winding coil and circumference parts was changed to red at the same case of non-application voltage.

Development of Weather Forecast Models for a Short-term Building Load Prediction (건물의 단기부하 예측을 위한 기상예측 모델 개발)

  • Jeon, Byung-Ki;Lee, Kyung-Ho;Kim, Eui-Jong
    • Journal of the Korean Solar Energy Society
    • /
    • v.38 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • In this work, we propose weather prediction models to estimate hourly outdoor temperatures and solar irradiance in the next day using forecasting information. Hourly weather data predicted by the proposed models are useful for setting system operating strategies for the next day. The outside temperature prediction model considers 3-hourly temperatures forecasted by Korea Meteorological Administration. Hourly data are obtained by a simple interpolation scheme. The solar irradiance prediction is achieved by constructing a dataset with the observed cloudiness and correspondent solar irradiance during the last two weeks and then by matching the forecasted cloud factor for the next day with the solar irradiance values in the dataset. To verify the usefulness of the weather prediction models in predicting a short-term building load, the predicted data are inputted to a TRNSYS building model, and results are compared with a reference case. Results show that the test case can meet the acceptance error level defined by the ASHRAE guideline showing 8.8% in CVRMSE in spite of some inaccurate predictions for hourly weather data.

Anchorage performance tests of SD700 hooked bar and headed bar with a anchorage length of 20db (20db 정착길이를 가지는 SD700 갈고리철근과 확대머리철근의 정착성능 실험)

  • Kim, Ho Young;Sim, Hye Jung
    • Journal of Urban Science
    • /
    • v.7 no.2
    • /
    • pp.21-27
    • /
    • 2018
  • With the increase of the skyscraper center, the development of large-diameter and high-strength reinforcing bars is being carried out to solve the dense reinforcement. In case of the steel reinforced concrete with a small cross section such as beam-column joints, the development length becomes short when straight bars are used. Therefore, it is possible to solve the problem that the development length becomes short by using the bearing strength of the hooked bar and headed bar. In this study, the exterior beam-column joint test of SD700 hooked bar and headed bar with anchorage length of 20db was conducted to extend the development length limitation of hooked bar and headed bar. As a result of the evaluation of the anchorage strength using the design equation by KCI, the average of the [measured value]/[predicted value] ratio was 1.31 for the hooked reinforcing bars. In the case of headed bars, the average of the [measured value]/[predicted value] ratio was 1.12. In addition, in order to compare the anchorage performance of the hooked bar and the headed bar, the measured values were divided by the square root of the compressive strength of the concrete to compare the anchorage strength. Under the same conditions, the anchorage strength of headed bars was 8.5% higher than the hooked bars.

The Forecast analysis on Non-electrical Machinery and Equipment of Macroeconomic variables (기계산업 수출액에 대한 거시경제변수의 예측 실험 - 보건과학분야의 정밀기계 수출액 포함 -)

  • Kim Jong-Kwon
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.04a
    • /
    • pp.471-484
    • /
    • 2006
  • The focus of analysis is effect on Non-electrical Machinery and Equipment of Macroeconomic variables through long-term and short-term periods. Also, this paper is related with implication on steady growth possibility of Non-electrical Machinery and Equipment. The period of variables is from 1985 to April in 2005. In case of not-available data is treated as missing figures. As spatial scope, these data are Non-electrical Machinery and Equipment on the basis of KSIC. In case of items, it composes MTI 1&3 digit of Korea International Trade Association (KITA), on the basis of HSK & classification of Korea Machinery industries. According to Granger causality test, yield of Cooperate Bond and export amount of Machinery have a meaning at statistical Confidence level of 10%. In case of index of the unit cost of export and export amount of Machinery, they have an interactive Granger cause. In yen dollar exchange rate and export amount of Machinery, former variable gives an unilateral Granger cause to latter that.

  • PDF

Study on short period effect of Marginal Loss Factor(MLF) in Cost Based Pool (CBP시장에서 한계손실계수(MLF)의 적용에 따른 단기적 영향분석)

  • Lee, Jae-Gul;Yoon, Yong-Beum;Ahn, Nam-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.43-45
    • /
    • 2006
  • Because Cost Based Pool(CBP) has any locational signals for electricity price, there are any locational incentives for construction of new power plant high efficient. in case of Korean electricity power market, this incentives are very important to reduce loss and congestion. This Paper represent the effect of MLF(Marginal Loss Factor) as locational price signal in short period. we investigate mathematically loss reduced effect of MLF and prove to reduce transmission loss using 3bus test system.

  • PDF

A study on the short-term load forecasting expert system considering the load variations due to the change in temperature (기온변화에 의한 수요변동을 고려한 단기 전력수요예측 전문가시스템의 연구)

  • Kim, Kwang-Ho;Lee, Chul-Heui
    • Journal of Industrial Technology
    • /
    • v.15
    • /
    • pp.187-193
    • /
    • 1995
  • In this paper, a short-term load forecasting expert system considering the load variation due to the change in temperature is presented. The change in temperature is an important load variation factor that varies the normal load pattern. The conventional load forecasting methods by artificial neural networks have used the technique where the temperature variables were included in the input neurons of artificial neural networks. However, simply adding the input units of temperature data may make the forecasting accuracy worse, since the accuracy of the load forecasting in this method depends on the accuracy of weather forecasting. In this paper, the fuzzy expert system that modifies the forecasted load using fuzzy rules representing the relations of load and temperature is presented and compared with a conventional load forecasting technique. In the test case of 1991, the proposed model provided a more accurate forecast than the conventional technique.

  • PDF

Short-Term Load Forecasting Using Neural Networks and the Sensitivity of Temperatures in the Summer Season (신경회로망과 하절기 온도 민감도를 이용한 단기 전력 수요 예측)

  • Ha Seong-Kwan;Kim Hongrae;Song Kyung-Bin
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.6
    • /
    • pp.259-266
    • /
    • 2005
  • Short-term load forecasting algorithm using neural networks and the sensitivity of temperatures in the summer season is proposed. In recent 10 years, many researchers have focused on artificial neural network approach for the load forecasting. In order to improve the accuracy of the load forecasting, input parameters of neural networks are investigated for three training cases of previous 7-days, 14-days, and 30-days. As the result of the investigation, the training case of previous 7-days is selected in the proposed algorithm. Test results show that the proposed algorithm improves the accuracy of the load forecasting.