• Title/Summary/Keyword: Short Fiber

Search Result 672, Processing Time 0.027 seconds

Fiber source and inclusion level affects characteristics of excreta from growing pigs

  • Mpendulo, Conference Thando;Chimonyo, Michael;Ndou, Saymore Petros;Bakare, Archibold Garikayi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.5
    • /
    • pp.755-762
    • /
    • 2018
  • Objective: The objective of the study was to determine the influence of varying fibrous diets on fecal characteristics of growing pigs. Methods: A total of 104 pigs (initial weight $18{\pm}2.0kg$) were used in the study. They were housed in individual pens and fed on diets containing maize cob, grass hay, lucerne hay, maize stover, and sunflower husk. These fibers were included at 0, 80, 160, 240, 320 and 400 g/kg. Fecal and urine samples were collected. Results: Fecal output was largest amongst pigs fed on diets containing grass hay and maize stover (p<0.05). Nitrogen content was highest in feces from pigs fed on sunflower husk (p<0.05). Pigs fed on diets containing maize stover and maize cobs produced the largest concentrations of short chain fatty acids. Acetate concentration was high in feces of pigs fed maize stover than those fed grass hay and lucerne hay (p<0.05). As the level of fiber inclusion increased, fecal consistency and nitrogen content increased linearly (p<0.05). Urea nitrogen decreased as the inclusion level increased across all the fibers (p<0.05), with maize cobs containing the largest content of urea nitrogen. As dietary fiber content increased, fecal nitrogen content also increased (p<0.05). Conclusion: It was concluded that different fiber sources influence fecal characteristics, thereby having different implications on pig waste management. It is vital to monitor fiber inclusion thresholds so as to easily manage environmental pollutants such as butyrate that contribute to odors.

EFFECTS OF CHOPPED GLASS FIBER ON THE STRENGTH OF HEAT-CURED PMMA RESIN

  • Lee Sang-Il;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.589-598
    • /
    • 2001
  • The fracture of acrylic resin dentures remains an unsolved problem. Therefore, many investigations have been performed and various approaches to strengthening acrylic resin, for example, the reinforcement of heat-cured PMMA resin using glass fibers, have been suggested over the years. The aim of the present study was to investigate the effect of short glass fibers treated with silane coupling agent on the transverse strength of heat-polymerized PMMA denture base resin. To avoid fiber bunching and achieve even fiber distribution, glass fiber bundles were mixed with PMMA powder in conventional mixer whose blade was modified to be blunt. Composite of glass fiber($11{\mu}m$ diameter, 3mm & 6mm length, silane treated) and PMMA resin was made. Transverse strength and Young's modulus were estimated. Glass fibers were incorporated with 1%, 3%, 6% and 9% by weight. Plasticity and workability of dough was evaluated. Fracture surface of specimens was investigated by SEM. The results of this study were as follows 1. 6% and 9% incorporation of 3mm glass fibers in the PMMA resin enhanced the transverse strength of the test specimens(p<0.05). 2. 6% incorporation of 6mm glass fibers in the PMMA resin increased transverse strength, but 9% incorporation of it decreased transverse strength(p<0.05). 3. When more than 3% of 3mm glass fibers and more than 6% of 6mm glass fibers were incorporated, Young's modulus increased significantly(p<0.05). 4. Workability decreased gradually as the percentage of the fibers increased. 5. Workability decreased gradually as the length of the fibers increased. 6. In SEM and LM, there was no bunching of fibers and no shortening of fibers.

  • PDF

Fiber Orientation and Warpage of Film Insert Molded Parts with Glass Fiber Reinforced Substrate (유리섬유가 강화된 필름 삽입 사출품의 섬유배향 및 휨)

  • Kim, Seong-Yun;Kim, Hyung-Min;Lee, Doo-Jin;Youn, Jae-Ryoun;Lee, Sung-Hee
    • Composites Research
    • /
    • v.25 no.4
    • /
    • pp.117-125
    • /
    • 2012
  • Warpage of the film insert molded (FIM) part is caused by an asymmetric residual stress distribution. Asymmetric residual stress and temperature distribution is generated by the retarded heat transfer in the perpendicular direction to the attached film surface. Since warpage was not prevented by controlling injection molding conditions, glass fiber (GF) filled composites were employed as substrates for film insert molding to minimize the warpage. Distribution of short GFs was evaluated by using micro-CT equipment. Proper models for micro mechanics, anisotropic thermal expansion coefficients, and closure approximation should be selected in order to calculate fiber orientation tensor and warpage of the FIM part with the composite substrate. After six kinds of micro mechanics models, three models of the thermal expansion coefficient and five models of the closure approximation had been considered, the Mori-Tanaka model, the Rosen and Hashin model, and the third orthotropic closure approximation were selected in this study. The numerically predicted results on fiber orientation tensor and warpage were in good agreement with experimental results and effects of GF reinforcement on warpage of the FIM composite specimen were identified by the numerical results.

Temperature Sensor Based on Fabry-Perot Interferometer Using a Fiber Optic Patch Cord (광섬유 패치코드를 이용한 Fabry-Perot 간섭계 온도센서)

  • Kim, Ju Ha;Jung, Eun Joo;Kim, Myoung Jin;Hwang, Sung Hwan;Lee, Woo Jin;Kim, Gye Won;An, Jong Bae;Choi, Eun Seo;Rho, Byung Sup
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.110-113
    • /
    • 2014
  • In this paper, we propose and demonstrate a Fabry-Perot interferometer (FPI) optical fiber tip sensor fabricated by a blade-sawing technique using a fiber optic patch cord for high-resolution temperature measurement. The sensor head consists of a short air FP cavity near the tip of a single-mode fiber patch cord tip. The temperature which we can measure is determined through a phase variation of the interference fringes in the reflective spectrum of the sensor. The fiber optic FPI sensor in this work can monitor the environmental temperature very accurately from 40 to $120^{\circ}C$. As a result, the temperature sensitivity is obtained as $38.2pm/^{\circ}C$.

Thermal Conducting Behavior of Composites of Conjugated Short Fibrous-SiC Web with Different Filler Fraction (짧은 섬유상간의 접합을 가진 Silicon Carbide Web 복합재료의 분율별 열전도 거동)

  • Kim, Tae-Eon;Bae, Jin Chul;Cho, Kwang Yeon;Lee, Dong Jin;Shul, Yong-Gun
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.549-555
    • /
    • 2012
  • Silicon carbide(SiC) exhibits many unique properties, such as high strength, corrosion resistance, and high temperature stability. In this study, a SiC-fiber web was prepared from polycarbosilane(PCS) solution by employing the electrospinning process. Then, the SiC-fiber web was pyrolyzed at $1800^{\circ}C$ in argon atmosphere after it was subjected to a thermal curing. The SiC-fiber web (ground web)/phenolic resin (resol) composite was fabricated by hot pressing after mixing the SiC-fiber web and the phenolic resin. The SiC-fiber web composition was controlled by changing the fraction of filler (filler/binder = 9:1, 8:2, 7:3, 6:4, 5:5). Thermal conductivity measurement indicates that at the filler content of 60%, the thermal conductivity was highest, at 6.6 W/mK, due to the resulting structure formed by the filler and binder being closed-packed. Finally, the microstructure of the composites of SiC-fiber web/resin was investigated by FE-SEM, EDS, and XRD.

The Effects of Steel-Fiber Reinforcement on High Strength Concrete Replaced with Recycled Coarse Aggregates More Than 60% (순환굵은골재 60% 이상 사용한 고강도 콘크리트에 대한 강섬유 보강 효과)

  • Kim, Yoon-Il
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.404-417
    • /
    • 2016
  • The purpose of this study is to examine the extent to which the deterioration in strength of high strength concrete of 60MPa replaced by a large amount of recycled coarse aggregates (more than 60% to 100% of replacement ratio) could be recovered with steel fiber reinforcement through material compressive strength test and shear failure test on short and middle beams and then to offer useful data for aggregate supply system of a sustainable resource circulation type. This study first examined the results of previous related tests. The results of the material compressive strength tests confirmed that when using a combination of steel fiber reinforcements of volumn ratio 0.75% and high quality recycled coarse aggregates with an water absorption rate within 2.0%, the strength characteristics of high strength concrete of 60MPa level were not only restored to the strength level of concrete made with natural aggregates, but also showed superior ductility. And the shear failure tests on short and middle beams using recycled coarse aggregates more than 60% with shear span to depth ratio (a/d) of 2 and 4 controlled by shear forces mainly confirmed that effects of superior shear strength increase and ductile behavior characteristics were showed by steel fiber reinforcements.

A Comparative Study on the Herbage Utilization from Tall type and Tall+short type Mixtures by Korean Native Goats (상번초 및 상ㆍ하번초형 혼파초지의 산양에 의한 초류이용성 비교 연구)

  • 이형석;이인덕
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.23 no.2
    • /
    • pp.129-134
    • /
    • 2003
  • This study was conducted to investigate the effect of tall type mixtures(TM) and tall + short type mixtures(TSM) on nutritive utilization. DM intake, digestibility and utilization of nitrogen and energy of herbages from pastures by Korean native goats were determined. This experiment was conducted by total collection method in laboratory, 2000. The experimental herbage included two treatments: Tall type mixtures(orchardgrass, Potomac 40+tall fescue, Fawn 20+Festulolium braunii, Paulita 10+perennial ryegrass. Reveille 10+timothy, Climax 10+red clover, Kenblue 5+alfalfa, Vernal 5%), Tall+short type mixtures {orchardgrass, Potomac 40+tall fescue, Fawn 20+Kentucky bluegrass, New port(turf type) 10+redtop, Barricuda(turf type) 10+perennial ryegrass, Palmer III(turf type) 10+red fescue, Flyer II(turf type) 5+white clover, Regal 5%}. The voluntary dry matter(DM) intake of Korean native goats fed with herbages from tall+short type mixtures(TSM) was slightly higher than that of tall type mixtures(TM), but no difference was observed between TSM and TM(p > 0.05). The digestibility of DM, neutral detergent fiber, cellular contents and acid detergent fiber of herbage from TSM was slightly higher than that of TM, but no difference was detected between TSM and TM(p > 0.05). The utilization of nitrogen and energy by Korean native goats did not showed any difference in herbages from TSM and TM(p > 0.05). In conclusion, the herbage utilization by Korean native goats did not showed any significant difference. Thus, there is a possibility that turf grasses in mixtures can be used as a forage sources.

Numerical analysis of the seismic performance of RHC-PVCT short columns

  • Xue, Jianyang;Zhao, Xiangbi;Ke, Xiaojun;Zhang, Fengliang;Ma, Linlin
    • Advances in concrete construction
    • /
    • v.8 no.4
    • /
    • pp.257-267
    • /
    • 2019
  • This paper presents the results of cyclic loading tests on new high-strength concrete (HC) short columns. The seismic performance and deformation capacity of three reinforced high-strength concrete filled Polyvinyl Chloride tube (RHC-PVCT) short columns and one reinforced high-strength concrete (RHC), under pseudo-static tests (PSTs) with vertical axial force was evaluated. The main design parameters of the columns in the tests were the axial compression ratio, confinement type, concrete strength, height-diameter ratio of PVCT. The failure modes, hysteretic curves, skeleton curves of short columns were presented and analyzed. Placing PVCT in the RHC column could be remarkably improved the ultimate strength and energy dissipation of columns. However, no fiber element models have been formulated for computing the seismic responses of RHC-PVCT columns with PVT tubes filled with high-strength concrete. Nonlinear finite element method (FEM) was conducted to predict seismic behaviors. Finite element models were verified through a comparison of FEM results with experimental results. A parametric study was then performed using validated FEM models to investigate the effect of several parameters on the mechanical properties of RHC-PVCT short columns. The parameters study indicated that the concrete strength and the ratio of diameter to height affected the seismic performance of RHC-PVCT short column significantly.

Prediction of Effective Thermal Conductivity of Composites with Coated Short Fibers of Different Aspect Ratios Using Hybrid Model (하이브리드모델을 이용한 장단비가 다른 코팅된 단섬유를 갖는 복합재의 등가열전도계수 예측)

  • Lee, Jae-Kon;Kim, Jin-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2618-2623
    • /
    • 2013
  • A hybrid model is proposed to easily predict the effective thermal conductivity of composites with aligned- and coated-short fibers, whose aspect ratio is not constant. The thermal conductivities of coated fillers are computed by using the generalized self-consistent model, resulting in that composites are simply simulated by the matrix with the equivalent short fibers. Finally, the thermal conductivity of the composites is predicted using the modified Eshelby model. The predicted results by the representative models and hybrid model are compared for the composite with aligned- and coated-short fibers of single aspect ratio. It is demonstrated that the hybrid model can be applied to the composite with aligned- and short-fibers of aspect ratios, 2 and 10, without any difficulties.

Evaluation of Field Applicability of Shotcrete for Fiber-net Integrated Tunnel Support System through Mock-up Test (목업 테스트를 통한 숏크리트용 섬유 그물망 일체형 터널 지보시스템의 현장 적용성 평가)

  • Kim, Jiyoung;Choi, Seongcheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.1
    • /
    • pp.72-78
    • /
    • 2020
  • The present study developed shotcrete for fiber-net integrated tunnel support system, which consists of fiber-net support materials including netlike fiber and shotcrete and integration technology between support materials. In addition, in order to evaluate the field applicability of the developed tunnel support system and compare with the performance of steel fiber reinforced shotcrete, mock -up test was conducted on the mock -up structure. The test results show that in the case of shotcrete containing coarse aggregate(S20A5RP10-C), the excessive rebound rate occurred as the secondary shotcrete was dropped during construction due to the degradation in bond performance with fiber-net. Also, in the case of steel fiber reinforced shotcrete, the amount of cast shotcrete fell short of target value due to the fiber ball and the degradation of pumpability. On the other hand, the amount of cast mortar shotcrete(S20A5RP10-M) and the installation position of fiber-net were almost close to the target values, and the lower rebound rate occurred compared to the steel fiber reinforced shotcrete.