• 제목/요약/키워드: Short Circuit Test

검색결과 259건 처리시간 0.027초

PCB 검사기의 단락측정 알고리즘에 관한 연구 (A study on the short-open testing algorithm of the PCB tester)

  • 이용석;정화자;김용득
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.269-272
    • /
    • 1988
  • This paper deals with the test strategy on the short-open for the printed circuit board. A group testing algorithm, which is the several testing point to be measured redefined as one of the testing points, was suggested. As a result, the total testing time was reduced to 30${\sim}$50 percent.

  • PDF

Roberts밸런을 갖는 단축 다이폴 안테나의 안테나 인자 (Antenna factors of short dipole antennas with roberts balun)

  • 김기채
    • 한국통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.532-538
    • /
    • 1997
  • Exactly aclculated antenna factors are requeired for determining EMI levels in an actual radiated emission test. In this paper, the antenna factors of short dipole antennas above the ground plane are calculated theoretically for the antenna with Roberts balun specified ANSI C63.5 regulation. Also treated is a half-wavelength dipole antenna with Roberts balun to compare the antenna factors with those of resonant dipole antenna. In formulationof antenna factors the antenna is treated as the boundary value problem of Maxwells equations and is analyzed by the Galerkins method of moments. The balun is treated using circuit theory based on power transmission mismatch.

  • PDF

MCM/PCB 회로패턴 검사에서 SEM의 전자빔을 이용한 측정방법 (Characterization Method for Testing Circuit Patterns on MCM/PCB Modules with Electron Beams of a Scanning Electron Microscope)

  • 김준일;신준균;지용
    • 전자공학회논문지D
    • /
    • 제35D권9호
    • /
    • pp.26-34
    • /
    • 1998
  • 본 논문은 주사전자현미경(SEM)의 전자총을 이용하여 MCM 또는 PCB 회로기판의 신호연결선에서 전압차를 유도시켜 개방/단락 등의 결함을 측정 검사하는 방법을 제시한다. 본 실험에서는 주사전자현미경의 구조를 변형시키지 알고 회로기판의 개방/단락 검사를 실시할 수 있는 이중전위전자빔(Dual Potential) 검사방법을 사용한다. 이중전위전자빔(Dual Potential) 측정검사 방법은 이차전자수율 값 δ의 차이를 유기시키는 δ < 1 인 충전 전자빔과 δ > 1 인 읽기 전자빔을 사용하여 한 개의 전자총이 각각 다른 가속전압에 의해 생성된 두 개의 전자빔으로 측정하는 방법으로 특정 회로네트에 대한 개방/단락 등의 측정 검사가 가능하다. 또한 읽기 전자빔을 이용할 경우 검사한 회로 네트를 방전시킬 수 있어 기판 도체에 유기된 전압차를 없앨 수 있는 방전시험도 실시할 수 있어, 많은 수의 회로네트를 지닌 회로 기판에 대해 측정 검사할 때 충전되어 있는 회로네트에 대한 측정오류를 줄일 수 있다. 측정검사를 실시한 결과 glass-epoxy 회로기판 위에 실장된 구리(Cu) 신호연결선은 7KeV의 충전 전자빔으로 충전시키고 10초 이내에 주사전자현미경을 읽기 모드로 바꾸어 2KeV의 읽기 전자빔으로 구리표면에서의 명암 밝기 차이를 읽어 개방/단락 상태를 검사할 수 있었다. 또한 IC 칩의 Au 패드와 BGA의 Au 도금된 Cu 회로패드를 검사한 결과도 7KeV 충전 전자빔과 2KeV 읽기 전자빔으로 IC칩 내부회로에서의 개방 단락 상태를 쉽게 검사할 수 있었다. 이 검사방법은 주사전자현미경에 있는 한 개의 전자총으로 비파괴적으로 회로 기판의 신호 연결선의 개방/단락 상태를 측정 검사할 수 있음을 보여 주었다.

  • PDF

저손실형 복합절연 주상변압기 개발 및 단락특성에 관한 연구 (A Study on the Development of Low-loss Type Hybrid Insulation Pole Transformers and)

  • 민윤홍;유호근;배선기;김호철;이윤재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.607-612
    • /
    • 2002
  • This paper presents the first domestic model product of hybrid Insulation low-loss type pole transformer, with increased overload ability, increased life, reduced loss, focusing improved short-circuit characteristics. The capacity of this transformer is 100 KVZ, rates first voltage 13200 V and secondary voltage 230/115 type. The volume of model transformer that was produced in high temperature using hybrid insulation can be reduced to 10-20% in comparison with that of present transformer with the same capacity. In this paper, we did short-circuit test and tested general characteristics of model transformer. In addition, we suggested design application new concept and methods thorough this experiment.

  • PDF

고장용량 감소를 위한 송전선 개방 운용에 신경회로망 적용 연구 (Neural Network Application to the T/L Operation for Suppression of Short Circuit Capacity)

  • 이광호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권1호
    • /
    • pp.26-30
    • /
    • 2000
  • Switching of the transmission lines(T/L) is one of the methods for wuppressing the short circuit capacity. This paper presents the T/L switching operation by using the Hopfield neural network(HNN). The switching of T/L can make the line powers and the bus voltages deteriorated, as well as the fault current decreased. Such an insecure state should be avoided when the T/L is operated to be open. In this studies, the inequality constraints are formulated into the objective function to be incorporated with the HNN. Test results show that the convergence characteristics of HNN lead to the adequate solution of T/L switching.

  • PDF

송.배전급 저항형 초전도 한류기 설계 요소 검출을 위한 고온 초전도 선재의 특성 연구 (Experimental Study on the High Temperature Superconductor for Investigated Design Factors of Distribution and Transmission Level Resistive Type Superconductor Fault Current Limiter)

  • 나진배;장재영;조현철;황영진;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.10-13
    • /
    • 2011
  • The power demand is steadily increasing due to rapidly develop of industrial field. The ratio of prospected increment of power consumption is over 2.2 % per year from 2007 to 2020 year. The superconducting fault current limiters(SFCLs) should be suggested to be one of promising machines to protect power grid. Four basis tests such as resistivity, short-circuit tests, ac losses and recovery time were investigated according to various reached maximum temperature, operating temperature. This paper deals with investigation of the various commercial high temperature superconductor for applying resistive type SFCLs.

단순병렬 자가발전 설비 보호방식 검토 사례 (A case Study for Protection Relay System of small Cogeneration intertie)

  • 이승재;김경식;윤갑구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.234-236
    • /
    • 2002
  • The Co-Gen System which maximize energy efficiency was installed at the industrial plants at the initial stage. However Small Scale Co-Gen System was expanded even to the general end-users such as housing and building owing to ESCO business recently. For this SSC, inter-connected operation to the utility is desirable due to voltage and frequency fluctuation following to unbalance between power output and load. Then voltage unbalance with utility system, frequency, increase of short circuit capacity, reclosing, and ALTS etc. should be fully considered for the inter-connected operation. Voltage variation, protection coordination, Co-Generators single running, and short circuit capacity should also be solved. To research the method and solve the problems through the field test and application, we study individual customers Co-Gen System as a case study.

  • PDF

압력배출구를 설치한 전동화 차량 배터리 시험실의 내부 폭압 평가 (Evaluation of Internal Blast Overpressures in Test Rooms of Elcetric Vehicles Battery with Pressure Relief Vents)

  • 방승기;신진원;정현진
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.7-18
    • /
    • 2022
  • Secondary batteries used in electric vehicles have a potential risk of ignition and explosion. Various safety measures are being taken to prevent these risks. A numerical study was performed using a computational fluid dynamics code on the cases where pressure relief vents that can reduce the blast overpressures of batteries were installed in the through-compression test room, short-circuit drop test room, combustion test room, and immersion test room in facilities rleated to battery used in electric vehicles. This study was conducted using the weight of TNT equivalent to the energy release from the battery, where the the thermal runaway energy was set to 324,000 kJ for the capacity of the lithium-ion battery was 90 kWh and the state of charge (SOC) of the battery of 100%. The explosion energy of TNT (△HTNT) generally has a range of 4,437 to 4,765 kJ/kg, and a value of 4,500 kJ/kg was thus used in this study. The dimensionless explosion efficiency coefficient was defined as 15% assuming the most unfavorable condition, and the TNT equivalent mass was calculated to be 11 kg. The internal explosion generated in a test room shows the very complex propagation behavior of blast waves. The shock wave generated after the explosion creates reflected shock waves on all inner surfaces. If the internally reflected shock waves are not effectively released to the outside, the overpressures inside are increased or maintained due to the continuous reflection and superposition from the inside for a long time. Blast simulations for internal explosion targeting four test rooms with pressure relief vents installed were herein conducted. It was found that that the maximum blast overpressure of 34.69 bar occurred on the rear wall of the immersion test room, and the smallest blast overpressure was calculated to be 3.58 bar on the side wall of the short-circuit drop test room.

대전류표준측정시스템을 위한 STL의 활동 (The activities of Short-circuit Testing Liaison for the high-current standard measurement system)

  • 신영준;김익수;김민규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.437-439
    • /
    • 2001
  • The plan of intercomparison test for high-current system was discussed concretely in the technical committee of STL in 2000. This paper describes the present state of the world, the plan & procedure of intercomparison test and test expenses for high-current system. In conclusion, this mentioned the matters that our country should prepare urgently.

  • PDF