• 제목/요약/키워드: Ship HVAC

검색결과 21건 처리시간 0.021초

선박 HVAC 효율 증가를 위한 변풍량 방식 공기조화 연구 (VAV Air Conditioning Research for Ship HVAC Efficiency)

  • 강영민;김민욱;장재희;김희망;오진석
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2016년도 춘계학술대회
    • /
    • pp.93-95
    • /
    • 2016
  • 최근 물동량 하락으로 인해 선박의 에너지 절감에 대한 선주들의 관심이 모아지고 있다. 선박용 HVAC은 선박 구조상 거주구역이 수밀형 창문으로 구성되고 폐쇄적이기 때문에 승무원의 쾌적한 환경 조성을 위해 사용된다. 또한 생활수준의 향상과 더불어 승무원들의 쾌적함에 대한 요구는 더욱 강해지고 있어 HVAC의 기능 향상이 요구되고 있다. 따라서 본 논문에서는 변풍량 방식의 선박용 HVAC 구조를 사용하여 HVAC 제어기능 향상 및 에너지를 절감할 수 있는 방법을 제시한다.

  • PDF

선박용 통합 HVAC 소음해석 프로그램 개발 (Development of Integrated HVAC Noise Analysis Program for Ships)

  • 한주범;홍석윤;송지훈;김노성;천승현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.588-593
    • /
    • 2011
  • The Main design parameters of ship HVAC systems are pressure drop and noise analysis of ducts. The Noise prediction for HVAC(Heating, Ventilating and Air Conditioning) systems are normally performed by empirical method suggested by NEBB(National Environmental Balancing Bureau, 1994), but NEBB's method is not suitable for the ship HVAC systems. In this paper, numerical analysis methods are used to develop a noise prediction method for the ship HVAC systems, especially for large ducts. To develop regression formula of attenuation of sound pressure level in large duct, Boundary Element Method(BEM) is used. Using dynamic loss coefficient which is suggested by ASHRAE fitting data base and numerical methods of HVAC noise analysis, integrated HVAC noise analysis of Program is developed. The developed program can present pressure drop and noise analysis of the ship HVAC systems. To verify the accuracy and convenience of the developed program, prediction of HVAC system for Semi-Submersible Drilling RIG is carried out and the results are compared with measurement of noise level during sea trial.

  • PDF

신조 운항실습선의 봄철 실내 온열환경 실측평가 (A Measurement and Evaluation on the Indoor Thermal Conditions in Spring of a New Training ship)

  • 신동걸;이진욱;이형기;박윤철;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권8호
    • /
    • pp.939-946
    • /
    • 2007
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those, supplied and controlled by ship's HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured on a newly-launched training ship during 2nd through 5th of April, 2007. Followings are the results of this study. (1)Because only partial loads are needed in spring season, the air volume from diffusers are measured as below 20%. (2)The temperatures are ranged between $20{\sim}25^{\circ}C$ and those are within comfort temperature range proposed by AHREA. (3)But humidities in cabins are very low and it could be the reason of a cold and/or a skin disease. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of low humidity, only 16.1% among the measured data are satisfied with the comfort standard range proposed by ASHREA. To improve the predictability and the comfort, HVAC should maintain the humidity as $40{\sim}60%$.

GUI Modeling을 기반으로한 선박의 HVAC System 소음 해석 (The Noise Analysis of Ship HVAC System Based on GUI Modeling)

  • 이철원;김노성;최수현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1300-1305
    • /
    • 2001
  • One of the main noise sources in cabin onboard ships is HVAC system. Up to now, the HVAC system designer manually calculates the HVAC system noise, or uses the program that is generally based on text user interface. In such a case, it is difficult to use the program and also to obtain the flow induced noise. In this study, the HVAC noise analysis program has been developed, which is based on GUI user interface that include 3.D modelling and model modification modules. For calculation of the insertion loss of HVAC system elements, NEBB experimental data and plane wave theory are used. And in order to obtain the flow rate information in each HVAC elements which is used to calculate the flow induced noise calculation, Global Converging Newton-Rapson Method is used.

  • PDF

공조시스템 유기 격실 소음 예측 프로그램 개발 (Development of Cabin Noise Prediction Program Induced by HVAC System)

  • 김병희;권종현;조대승
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.554-558
    • /
    • 2004
  • In this paper, we introduce noise prediction program of HVAC system to assist low-noisy design of ship's cabin. The developed program calculates sound power levels at HVAC components considering primary and secondary noise generated by fan and duct element, duct element noise attenuation, and duct break-in noise based on the authentic empirical method suggested by NEBB and acoustic power balancing method. Sound pressure level at cabin with or without ceiling system is evaluated by the diffuse-field theory considering diffuser and duct break-out sound powers. Moreover, the program provides intuitive pre- and post-processors using modem GUI functions to help efficient modeling and evaluation of cabin and HVAC component noise. To validate the accuracy and convenience of the program, noise prediction for a HVAC system is demonstrated.

  • PDF

A Seasonal Indoor Thermal Conditions of a Newly-launched Training Ship

  • Hwang, Kwang-Il;Shin, Dong-Keol;Lee, Jin-Uk;Lee, Sang-Il
    • 한국항해항만학회지
    • /
    • 제33권4호
    • /
    • pp.289-294
    • /
    • 2009
  • The living performances of crews and passengers in cabins have been less received attention, while Korea is a top leading country in ship building industry. To develop a high value added ships like 5-star cruisers, researches on the comfort and productivity in cabins should be carried out with urgent. The purpose of this study is to measure and analyze of the ship's indoor thermal conditions in spring, summer and winter, and also to compare the seasonal differences, of which conditions are supplied from and controlled by marine HVAC The temperature, humidity and air supply volume of 5 different needs of cabins on a training ship were measured through a year, which was launched at Dec. 2005 and totally 246 crews can go on board for education. The following results were obtained: (1)In the spring, the temperature in cabins was measured as $20{\sim}25^{\circ}C$ and humidity was below 30%. (2)In the summer, the temperatures was controlled at $21{\sim}27^{\circ}C$ in almost cabins and humidity was between $40{\sim}60%$ which is known as comfort conditions. (3)In the winter, temperature and humidity was maintained between $19{\sim}26^{\circ}C$, and humidity was between $10{\sim}50%$. (4)It is clear that the humidity conditions in cabins are not properly controlled at all through a year to satisfy the Comfort Standards provided by ASHRAE and/or ISO, In conclusion, humidification and dehumidification of cabins must be treated with importance for more comfort living and working environments for crews and passengers.

신조 운항실습선의 여름철 실내 온열환경 실측평가 (A Measurement and Evaluation on the Indoor Thermal Conditions in Summer of a New Training ship)

  • 신동걸;이진욱;이형기;황광일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.276-283
    • /
    • 2008
  • The purpose of this study is to measure and analyze the ship's indoor thermal conditions and also to integrate experimental database of those which are supplied and controlled by marine HVAC. On this study, temperature, humidity and air volume of 6 different needs' cabin are measured like previous report on a newly-launched training ship during 25th through 27th of July, 2007. Followings are the results of this study. (1)The air supply volumes to each cabins are measured 250CMH(Recreation room), 800CMH(Conference room), 1.000CMH(Bridge), 5,100CMH(Lecture room) respectively. (2)The temperatures are maintained at $21{\sim}27^{\circ}C$ in almost cabins through measuring period, but the temperatures are fluctuated over ${\pm}4^{\circ}C$ at the bridge and conference room. (3)The relative humidities are shown between $40{\sim}60%$ known as comfort conditions, but the conference room is needed to dehumidified because of over 70% humidity. (4)From the student cabins' measurements which have different supply diffuser(s), it is clear that the design is suitable for this case. (5)Because of temperature diversities, only 32% among the measured data are satisfied with the comfort standard range proposed by ASHREA.

조선 : KS-STEP

  • 김용대
    • 한국전자거래학회:학술대회논문집
    • /
    • 한국전자거래학회 2000년도 종합학술대회발표논문집
    • /
    • pp.115-126
    • /
    • 2000
  • □ Ship Structural Envelope : hull form(AP216), arrangements(AP215), structure(Ap218) □ Distributed Systems : piping(AP227), electrical(AP212), HVAC(AP227) □ Mission Subsystems/Equipment : mechanical(AP226), electronics(AP212), operation(AP234) outfit and furnishings (FunSTEP), weapons(중략)

  • PDF

590인승 Ro-Pax형(型) 연안여객선의 선실 내 봄철 온열환경 측정평가 (A Measurement and Evaluation of Indoor Thermal Conditions in Spring of a Coastal Passenger Ship - 590-Passenger Ro-Pax Type)

  • 황광일;신동걸;김은수;도요한;최윤석;최정열
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권8호
    • /
    • pp.1170-1177
    • /
    • 2008
  • The purpose of this study is to measure and analyze the indoor thermal conditions in the spring of a korean coastal passenger ship which is 590-passenger Ro-Pax type built at 1997. Especially this study has focussed on the relations between the diffuser open ratio, which can be controlled by 12 steps, and the comfort. Followings are the results of this study. (1) The supply air volume to cabins are maximum 4.3 and 2 times more than design quantity when the diffusers in cabins are open 100% and 50%, respectively. (2) Regardless of diffuser open ratio, the supply air maintains constantly high temperature and below 10% of relative humidity through the experimental days. (3) All the cabins are not satisfied with the ASHRAE comfort criterion at the condition of 100% and 50% of diffuser open ratio, because of high temperature and low relative humidity. (4) At a low diffuser open ratio, number of cabins which satisfy the ASHRAE comfort criterion are increased. (5) Humidifying and dehumidifying, and hvac control system of each cabin must be reviewed and studied at the view of passengers to service more comfort environments.

A Study on the Dynamic Loss Coefficients of Non-standard Fittings in Ship Exhaust Gas Pipes

  • Park, Seongjong;Park, Yonghwan;Kim, Bongjae;Choi, Jaewoong
    • 한국해양공학회지
    • /
    • 제33권5호
    • /
    • pp.479-485
    • /
    • 2019
  • As exhaust gas systems of ships become more complicated, it is necessary to calculate an accurate pressure loss at their design stage. If the dynamic loss coefficients of non-standard fittings mainly used in exhaust gas pipe (EGP) are well-documented, it would be possible to calculate precise pressure loss more readily than using the conventional method that analyzes the entire system. In the case of a ship's EGP, the flow rates and temperatures of exhaust gas are determined by engine specifications, and the range of the flow rate and temperature is limited according to operating conditions. In addition, as it is possible to define non-standard fittings frequently used in an EGP, a database can be easily constructed and effective. This paper illustrates effective parameters and analysis cases of several types of non-standard fittings mounted in ship EGPs. The analysis procedure proposed in this paper is verified using existing research results on HVAC fittings. The numerical procedure, which is minimally affected by manpower and grid, is established such that it can be applied at the industry level.