• Title/Summary/Keyword: Shields 선도

Search Result 22, Processing Time 0.023 seconds

Channel Design of Decanter-Type Centrifuge (I) - Particles′ Suspension and the Channel Size (원심분리기의 채널 설계(I) - 입자의 부유문제와 채널 크기)

  • 서용권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.148-155
    • /
    • 2003
  • In this paper, based on the concept of solid particles' hovering problem the working formula for the channel design of a Decanter-type centrifuge were derived. The Shields' diagram and its curve-fitting formula were used in determining the criterion of particle size for the sediment. By using these formula the designer can determine the sectional configuration of the channel, such as the liquid depth, the normal pitch of the screw-blade arrangement and the bowl diameter.

Transmission Line Characteristics of Silicon Based Interconnections with Patterned Ground Shields and its Implication for RF/Microwave ICs (실리콘 공정에서 패턴으로 삭각된 접지(PGS)를 이용한 인터컨넥션의 전송선 특성분석 및 RF/초고주파 집적회로에의 응용)

  • Gwak, Huk-Yong;Lee, Sang-Gug;Cho, Yun-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.6
    • /
    • pp.50-56
    • /
    • 2000
  • The integrated circuit interconnection lines are experimented with patterned ground shields (PGS) at microwave frequencies. Measurement results demonstrate that the PGS can significantly reduce the power loss through the interconnect lines over wide frequency ranges as the PGS shields the lossy silicon substrate. The transmission line characteristics of the PGS interconnect lines are analyzed and identified that the PGS reduces the wave length of the interconnect line.

  • PDF

Evaluation of the X-ray Shielding Ability of Lead Free Board Shielding in the CT Room (CT실에서 무연보드 차폐체의 X선 차폐능력 평가)

  • Sung-Joon Kim;Tae-Ho Han;Hyo-Won Lee;Yu-Whan Oh;Seung-Chul Kim;Jung-Min Kim
    • Journal of radiological science and technology
    • /
    • v.47 no.4
    • /
    • pp.249-254
    • /
    • 2024
  • This study compared the X-ray shielding abilities of the shields using Computed Radiography(CR) System after manufacturing a lead-free boards using gypsum and BaSO4, an eco-friendly X-ray shielding material. Total six lead-free boards were manufactured with BaSO4 concentrations of 25 %, 50 % and thickness of 10 mm, 15 mm, 20 mm respectively, and additional thickness of 1.0 mm, 1.5 mm, 2.0 mm leads were prepared. In the experiment, Nine shields were placed on the Image Plate and placed in a Computed Tomography(CT) Room where CT scans were performed for 2 weeks. After that, the X-ray image of the shields were obtained through CR Reader, and Pixel Value(PV) were measured to evaluated the X-ray shielding abilities of the lead-free shields. The criterion for evaluating the shields was determined by comparing PV of lead-free board to that of the 1.5 mm thickness lead used in the CT rooms. As a result of the experiment, the PV of the lead-free boards within 25 % of the BaSO4 concentration and within 10 mm of the thickness were not enough to be used as X-ray shields in the CT Room because they did not reach the PV of the 1.5 mm thickness lead. BaSO4 concentration of 50 % at 20 mm thickness showed PV of 1.5 mm lead thickness or more indicating that it has an X-ray shielding ability to replace lead in the CT room

A Fundamental Study of the Silla Shield through the Analysis of the Shape, Dating, and Species Identification of Wooden Shields Excavated from the Ruins of Wolseong Moat in Gyeongju (경주 월성 해자 유적 출토 목제방패의 형태, 연대 및 수종분석을 통한 신라 방패의 기초적 연구)

  • NAM, Tae-Gwang;KIM, Hun-Suk
    • Journal of the Korean Wood Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.154-168
    • /
    • 2021
  • Various types of wooden relics are being unearthed following the full-scale excavation in Wolseong palace site, Gyeongju in Korea. In particular, a large number of relics were found in the moat surrounding the Wolseong Fortress. This study attempted to secure basic data on the shields of the Silla era through species identification, radiocarbon dating, and shape analysis of the two wooden shields excavated from the Wolseong moat. As a result of the radiocarbon dating, it was confirmed that the shields were made of wood procured in the period between the mid-4th century and the early 5th century. The species identification confirmed that the body of the relic was made with Pinus soft pine group and the handle with Zelkova serrata. It was also confirmed that the excavated wooden shield was made by first marking a thin line on a flat grain board, then marking double concentric circles and perforating small holes. The distance between the division lines is constant at about 6cm, and spaces between them are colored in red and black. The shape analysis estimated that two artifacts were more than 50cm and 36cm in width, respectively.

Usability Evaluation through Gonad Shielding Production of Pediatric Patients by Gender and Age Rating (소아 환자의 성별과 연령별 생식선 차폐체 제작을 통한 유용성 평가)

  • CHOI, Sung-Hyun;PARK, Jung-Eun;Dong, Kyung-Rae;Chung, Woon-Kwan;Ju, Yong-Jin;Yang, Nam-Hee
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.69-75
    • /
    • 2015
  • Purpose: The gonad shielding is used to minimize the impact of the exposure to gonads when Abdomen, Pevis and Hip X-ray inspections are conducted on radiation impressionable pediatric patients. By the way, the gonad is palpable difficult and impossible to check visually because it's a sensitive area, so tests are conducted with the approximate location of shielding, thereby appearing problems of not shielding gonads accurately. Accordingly, this study produced shields by age and gender of pediatric patients and studied the method of positioning shields with ASIS as a reference point without palpable sensitive areas, and tried to evaluate its usability. Materials and methods: The study surveyed 30 pediatric patients by gender and age, who came and got inspected in Department of Radiology, our hospital from February 2012 to January 2014 and obtained the value of tolerance by measuring the average size of the pelvis using the distance measurement function of Infinitt Piview with the images stored in the PACS and producing shields by age and gender of pediatric patients and specifying the areas at random for the comparative analysis of pre- and post-using. It calculated the technology statistics($mean{\pm}SD$) with the value of tolerance measured the length using SPSS 12.0 statistical program. Results: As for boys, differences in the tolerance range of pre- and post-using shields were 2.69 mm in case of 1 year old, 2.58 mm in 2 years, 2.37 mm in 3 years, 2.815 mm in 4~5 years, 2.043 mm in 7~10 years, and as for girls, 1.92 mm in 1~2 years, 1.75 mm in 3~4 years, 2.52 mm in 5~6 years and 1.93 mm in 7~10. After analyzing the pre- and post-using shields for all of boys and girls, there were statistically significant differences(P<0.050). Conclusions: It is considered that we can minimize the exposure to gonads and get a better video for diagnosis in testing high biological impressionable pediatric, if we use shields correctly with ASIS as a reference point considering its shape and size by age and gender in Abdomen, Pevis and Hip X-ray inspections.

A Case of Sebaceous Adenoma in Medial Caruncle of the Eye (내안누구에 발생한 피지선종 1예)

  • Jun, Jong-Hwa;Lee, Se-Youp;Kim, Jin-Hee
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.2
    • /
    • pp.199-201
    • /
    • 2007
  • 피지선종(sebaceous adenoma)은 피지선 분화를 보이는 신생물 중 가장 흔한 종양으로 피지선이 정상적으로 많이 분포하는 안면부, 두피부, 안검부 등에 주로 발생하나 안검에서는 비교적 드물게 발생한다. 피지선종은 피부부속기 종양 중 발생빈도가 아주 낮으며 안면부 중에도 피지선이 많이 분포하는 비부와 협부에 주로 발생하며 종괴 형성으로 인한 이물감이나 소양감, 출혈, 궤양형성등의 증상을 동반한다. Shields 등의 보고에 의하면 내안누구에 발생한 신생물 57예중에서 피지선종은 2예만이 존재할 정도로 극히 드물다고 하였다. Font와 Rishi도 피지선종의 안검 발생에 대하여 상안검과 하안검은 각각 같은 빈도로 발생한다고 하였으며 내안각 피지선종은 단 1예만을 보고하였다. 이에 저자들은 내안누구의 피지선에서 발생한 피지선종을 경험하고 문헌고찰과 함께 그 1예를 보고하고자 한다.

Comparison of Shield of Breast, Thyroid, Eyes for Exposure Dose Reduction in Mammography (유방엑스선검사 시 유방, 갑상샘, 안구 피폭선량 감소를 위한 차폐체 비교)

  • An, Se-Jeong;Ahn, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.189-194
    • /
    • 2021
  • This study was conducted to reduce the exposure dose to the breast and adjacent organs as the number of Mammography increased. Therefore, it has been designed a shield in lead, bismuth + tungsten, and bismuth that does not require to be equipped by the patient, in which each type of shield was compared and analyzed of radiation exposure dose to breast, thyroid, and eye. Using a mammography machine, optically stimulated luminescent dosimeter(OSLD) was inserted to bilateral breast, thyroid, and eye of a dosimetry phantom to measure dose radiated onto the phantom. Shielding device was made in different thickness of 2mm, 3mm, and 5mm and dose evaluation was performed by measuring the dose while using lead, bismuth, and bismuth + tungsten prosthesis. When each shields combined with shielding device, were compared of dose, all showed similar does reduction in the dose to breast, thyroid, and eye in both cranialcaudal and mediolateraloblique view. Based on the current study, bismuth and bismuth + tungsten can replace conventional lead shield and it is anticipated to safely and conveniently reduce radiation exposure to breast, thyroid, and eye with the shield that does not require to be equipped.

Analysis of HEMP Coupling Signal for a Coaxial Cable with Braided Shields (Braided Shield를 가진 동축 케이블의 HEMP 결합 신호 해석)

  • Lee, Jin-Ho;Cho, Jea-Hoon;Kim, Eung-Jo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.8
    • /
    • pp.790-796
    • /
    • 2011
  • The system which is exposed in the impact range of High-altitude Electromagnetic Pulse(HEMP) may get serious damage because HEMP has a very large electric field value, a very fast rise-time, and so on. Electromagnetic analysis should be performed for signals coupled to the opening or cables of the system prior to derive the system design specifications in order to protect the system against HEMP adequately. In this paper, we analyzed the HEMP coupled signals for the coaxial cable which is generally used to transmit and receive video or RF signals and compared the coupled signal of the one wire with that of the inner conductor of a coaxial cable to confirm the decreased effect of HEMP by the shield. The coaxial cable is analyzed by the external and internal region of the shield separately. For the external region of the coaxial cable, general scattered equation was applied to calculate currents on the surface of the shield and for internal region of the coaxial cable, chain matrix algorithm is used. To verify this paper the analyzed results were compared the results of the existing paper and the two results have good agreements.

Study of occupational exposure in PET/CT (PET/CT 종사자의 방사선피폭에 관한 연구)

  • Na, Soo-Kyung;Park, Byung-Sub;Kang, Yong-Gil
    • Journal of Digital Convergence
    • /
    • v.10 no.11
    • /
    • pp.449-457
    • /
    • 2012
  • The purpose of this study is to investigate the relationship between radiation origin and health professionals, and to reduce exposed dose of radiation through efficient management. Increasing exposed dose of radiation to health professionals are caused by the increase of PET/CT use and a radioactive isotope. Hence, in this study, space dose from each origin of radiation generating was analyzed and the use of personnel protective clothing and shields was compared. As a result of this study, we confirmed that the exposed dose of radiation was much higher in case of wearing personnel protective clothing(0.5 mm pb) than no wearing personnel protective clothing under high energy gamma radiation(511 keV) of the position emitter($^{18}F$).

Comparison of General Concrete and Low-radiation Concrete as Shielding Materials for Medical Linear Accelerators (의료용 선형가속기 차폐 재질로써 일반 콘크리트와 저 방사화 콘크리트 비교)

  • Lee, Dong Yeon;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • This study is a neutron activation for concrete that shields medical linear accelerator facilities. Comparison of general concrete and low activation concrete. The simulation method was simulated using MCNPX (Ver. 2.5.0) and FISPACT-2010, and the shielding ability for photon and neutron beams was calculated and neutron activation evaluation was carried out. As a result, the shielding capacity was 20 ~ 50 cm efficient in general concrete, and activate evaluation in low activation concrete was calculated to be low in radioactivity concrete, but all were estimated to not exceed their own allowable concentration in self - disposal. As a result of the comprehensive analysis, it is considered effective to use ordinary concrete.