• 제목/요약/키워드: Shielding Failure

검색결과 35건 처리시간 0.034초

A Metamodeling Approach for Leader Progression Model-based Shielding Failure Rate Calculation of Transmission Lines Using Artificial Neural Networks

  • Tavakoli, Mohammad Reza Bank;Vahidi, Behrooz
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권6호
    • /
    • pp.760-768
    • /
    • 2011
  • The performance of transmission lines and its shielding design during a lightning phenomenon are quite essential in the maintenance of a reliable power supply to consumers. The leader progression model, as an advanced approach, has been recently developed to calculate the shielding failure rate (SFR) of transmission lines using geometrical data and physical behavior of upward and downward lightning leaders. However, such method is quite time consuming. In the present paper, an effective method that utilizes artificial neural networks (ANNs) to create a metamodel for calculating the SFR of a transmission line based on shielding angle and height is introduced. The results of investigations on a real case study reveal that, through proper selection of an ANN structure and good training, the ANN prediction is very close to the result of the detailed simulation, whereas the Processing time is by far lower than that of the detailed model.

Optimization of shielding to reduce cosmic radiation damage to packaged semiconductors during air transport using Monte Carlo simulation

  • Lee, Ju Hyuk;Kim, Hyun Nam;Jeong, Heon Yong;Cho, Sung Oh
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1817-1825
    • /
    • 2020
  • Background: Cosmic ray-induced particles can lead to failure of semiconductors packaged for export during air transport. This work performed MCNP 6.2 simulations to optimize shielding against neutrons and protons induced by cosmic radiation Methods and materials: The energy spectra of protons and neutrons by incident angle at the flight altitude were determined using atmospheric cuboid model. Various candidates for the shielding materials and the geometry of the Unit Load Device Container were evaluated to determine the conditions that allow optimal shielding at all sides of the container. Results: It was found that neutrons and protons, at the flight altitude, generally travel with a downward trajectory especially for the particles with high energy. This indicated that the largest number of particles struck the top of the container. Furthermore, the simulation results showed that, among the materials tested, borated polyethylene and stainless steel were the most optimal shielding materials. The optimal shielding structure was also determined with the weight limit of the container in consideration. Conclusions: Under the determined optimal shielding conditions, a significantly reduced number of neutrons and protons reach the contents inside the container, which ultimately reduces the possibility of semiconductor failure during air transport.

국내에서 발생한 낙뢰고장 분석을 통한 직격뢰 및 역섬락 고찰 (Consideration on shielding failure and back flashover through lightning fault analysis within the country)

  • 최한열;민병욱;박순규;이봉희;구성완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.280_281
    • /
    • 2009
  • The past 3 years study on the lightning faults data shows that the main reason is shielding failure rather than back flashover. Accordingly, we need to thoroughly consider about shielding failure angle of tower. Also, transmission line damage caused by shielding can be minimized if we avoid the steep slope area as a transmission line route.

  • PDF

Analysis of Different 500kV HVAC Transmission Lines Lightning Shielding

  • Nayel, Mohamed
    • 한국융합학회논문지
    • /
    • 제4권4호
    • /
    • pp.49-57
    • /
    • 2013
  • The lightning shielding of different 500 kV HVAC-TL high voltage AC transmission lines was analyzed. The studied transmission lines were horizontal flat single circuit and double circuit transmission lines. The lightning attractive areas were drawn around power conductors and shielding wires. To draw the attractive areas of the high voltage transmission lines, transmission line power conductors, shielding wires and lightning leader were modeled. Different parameters were considered such as lightningslope, ground slope and wind on lightning attractive areas. From the calculated results, the power conductors voltages affected on attractive areas around power conductors and shielding wires. For negative lightning leader, the attractive area around the transmission line power conductor increased around power conductors stressed by positives voltage and decreased around power conductors stressed by negative voltage. In spite of this, the attractivearea of the transmission line shielding wire increasedaround the shielding wire above the power conductor stressed by the positive voltage and decreased around the shielding wire above the power conductor stressed by negative voltage. The attractive areas around power conductors and shielding wires were affected by the surrounding conditions, such as lightning leader slope, ground slope. The AC voltage of the transmission lines made the shielding areas changing with time.

뇌 차폐 해석에서 뇌격흡인 거리 수식과 영향 비교 (Comparison of Striking Distance Formulae and Their Effect on Lightning Shielding Analysis)

  • 김성삼
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.694-699
    • /
    • 2011
  • This paper compares the performance of lightning shielding analysis methods using the seven striking distance formulae in substation. For comparison, we evaluate the number of expected strikes and exposed area using WinIGS Software. Seven striking distance formulae are compared using the electrogeometric model analysis and the rolling sphere method. Based on the electrogeometric model analysis, the risk of shielding failure in either the whole substation or parts of it is determined. According to the simulation results, one can justify whether the substation satisfies the criterion of shielding design. In particular, according to the rolling sphere method, the exposed areas in substation determine the location of the additional shielding poles or shield wires. Therefore, the installation of the additional shielding poles and shield wires in substation was accepted by shield design at the phase conductors exposed in the larger area.

345[KV] 송전선로의 뇌방호 실패의 예측과 그 대책에 관한 연구 (A study on lighting performance of 345[KV] model line)

  • 이봉용
    • 전기의세계
    • /
    • 제29권1호
    • /
    • pp.65-72
    • /
    • 1980
  • Arstrong-Whitehead theory on effective shielding and shielding failure is extended so that it is applicable to vertical line configuration the existing approaches on back-flash rate calculation are summerized and compared in particular on Model Line, and the usefulness of the whitehead approach is suggested.

  • PDF

유한요소법을 이용한 인공고관절 주대형태의 개선에 대한 연구 (A Study for Improvement of the Femoral Stem Type using the Finite Element Analysis)

  • 윤경렬;원예연;이수훈
    • 한국CDE학회논문집
    • /
    • 제5권2호
    • /
    • pp.122-126
    • /
    • 2000
  • A major mechanical problem with total hip replacement is the loosening of the femoral component. The loss of proximal support, with firm fixation distally, has been thought to be a major caused of fatigue failure of femoral stems. While many causes have been proposed, the most frequently suggested cause of the calcar resorption is the disuse atrophy of the cortex of the calcar due to the stress shielding of the proximal bone by the metal femoral stem. In this research, the new-designed stem(modified collar stem) was considered which made a hole inside stem and had a 3 mm thickness. Using the 3-dimensional finite element methods, the common collar stem and the modified colla stem was modeled and analysed. Also, the two models was compared. The results showed that the modified collar stem decreased the stress-shielding and it made a effective load transfer at the entire femoral region.

  • PDF

전자파 차폐도어용 힌지의 가속 수명 시험법 설계 (Accelerated Life Test Design of an Electromagnetic Shielding Door Hinge)

  • 김도식;정한영
    • 대한기계학회논문집A
    • /
    • 제41권9호
    • /
    • pp.887-895
    • /
    • 2017
  • 본 논문에서는 일반적으로 문틀과 문짝을 연결하여 개폐시 작동하는 부품인 힌지의 가속수명시험법에 대한 연구이다. 힌지는 사용하는 용도에 따라 구조와 고장모드가 상이하며 본 연구에서는 전자파 차폐시설에 사용되는 개폐장치 구성품 중 하나인 힌지에 대해서 고장모드를 분석하고 현장작동조건에서의 이론적 검증과 시험장비에 대한 타당성을 분석하였다. 그리고 형상모수와 가속지수의 추정을 통한 특성수명 예측을 위한 가속수명시험법을 설계하였다.

A numerical approach for assessing internal pressure capacity at liner failure in the expanded free-field of the prestressed concrete containment vessel

  • Woo-Min Cho;Seong-Kug Ha;SaeHanSol Kang;Yoon-Suk Chang
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3677-3691
    • /
    • 2023
  • Since containment building is the major shielding structure to ensure safety of nuclear power plant, the structural behavior and ultimate pressure capacity of containments must be studied in depth. This paper addresses ambiguous issue of determining free-field position for liner failure by suggesting an expanded free-field region and comparing internal pressure capacities obtained by test data, conservative assumption and suggested free-field region. For this purpose, a practical approach to determine the free-field position for the evaluation of liner tearing is carried out. The maximum principal strain histories versus internal pressure capacities among different free-field positions at various azimuths and elevations are compared with those at the equipment hatch as a conservative assumption. The comparison shows that there are considerable differences in the internal pressure capacity at liner failure within the expanded free-field region compared to the vicinity of the equipment hatch. Additionally, this study proposes an approximate correlation with conservative factors by considering the expanded free-field ranges and material characteristics to determine realistic failure criteria for liner. The applicability of the proposed correlation is demonstrated by comparing the internal pressure capacities of full-scale containment buildings following liner failure criteria according to RG 1.216 and an approximate correlation.