• Title/Summary/Keyword: Shielded

Search Result 453, Processing Time 0.029 seconds

A Calculation of the Capacitance of a Shielded Microstrip Line using the Finite Element Method (FEM을 이용한 Shielded Microstrip Line의 정전용량 해석)

  • Lee, Woo-Chan;Kim, Hyung-Suk;Rayan, Adel
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1664-1665
    • /
    • 2011
  • This paper presents a derivation of the capacitance of a shielded microstrip line using the Finite Element Method (FEM). The first approach adopts a 2-D version of Gauss's theorem and an approximation of integral to finite differencing. In this case, the choice of a contour and the size of a mesh affects the validity of the capacitance. Next, the method for deriving the capacitance by using of energy relation is shown. Finally, the simulation results are compared to those of the commercial tool (COMSOL) adopted FEM.

  • PDF

The design and analysis of Operational characteristic of Shielded Inductive Fault Current Limiter using high-$T_c$ Superconducting (고온초전도체를 이용한 차폐유도형 전류제한기의 설계 및 동작 특성해석)

  • Song, Jae-Joo;Lee, Jae;Lim, Sung-Hun;Kang, Hyeong-Gon;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.339-342
    • /
    • 2001
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter(FCL) were simulated and analyzed to search for the parameter to determine FCL operation, Fault current limiting operation can be executed as resistive or inductive type, which is determined by iron-core radius and the number of the primary coil turns. It was considered through this paper that the operation of each was compared and examined about the merit of each mode.

  • PDF

design of shielded inductive SFCL made of high $T_c$ superconductor (고온초전도체를 이용한 차폐유도형 전류제한기의 설계)

  • Lim, Sung-Hun;Kang, Hyeong-Gon;Park, Kyung-Kuk;Han, Tae-Hee;Cho, Dong-Eon;Han, Byoung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1531-1533
    • /
    • 1998
  • In this paper, the characteristics of the shielded inductive superconducting fault current limiter was designed and simulated. Parameters of design for superconducting tube, core and primary coil were first determined. And then according to the system characteristics such as load resistance, fault angle and source voltage, the simple power system composed of shielded inductive FCL was simulated by computer-aided numerical analysis. The flowing currents under the fault condition can be limited to about 10 A.

  • PDF

Effect of Polymer Shielding on Elution of G3PDH Bound to Dye-ligand Adsorbent

  • Ling Tau Chuan;Lyddiatt Andrew
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.1
    • /
    • pp.84-87
    • /
    • 2006
  • Batch binding experiments were performed to assess the recovery performance of glyceraldehyde 3-phosphate dehydrogenase (G3PDH) bound to the unshielded and polymer (polyvinyl pyrrolidone. PVP)-shielded dye-ligand (Cibacron Blue 3GA) adsorbent. The adoption of a polymer-shielded, dye-ligand technique facilitated the elution efficiency of bound G3PDH. It was demonstrated that the recovery of G3PDH using polymer-shielded dye-ligand adsorption yielded higher elution efficiency, at 60.5% and a specific activity of 42.3 IU/mg, after a low ionic strength elution (0.15 M NaCl). The unshielded dye-ligand yielded lower elution efficiency. at 6.5% and a specific activity of 10.2 IU/mg.

Effects of gas formers on metal transfer of the self-shielded flux cored arc welding (Self-shielded flux cored arc welding시 가스 발생제가 용적 이행 현상에 미치는 영향)

  • 정재필;김경중;황선효
    • Journal of Welding and Joining
    • /
    • v.3 no.1
    • /
    • pp.40-45
    • /
    • 1985
  • Wire meling characteristics were examined with variation of gas formers such as $MgCO_3, CaCO_3 and Li_ 2CO_ 3$ by self-shielded flux cored arc welding. The flux cored wire of overlap type was welded by DCRP. The results obtainedareas follows. 1) Drop type was observed with no gas former, repelled type with MgCO_3$ added and short circuit type with $Li_2CO_3$ added. The variation of transfer mode was related to the blowing force of $CO_2$ gas and the surface tension of the slag. 2) Droplet size increased with adding gas formers due to the effect of $CO_2$ gas cushion. 3) Core spikes were observed more frequently with increasing the amount of gas formers.

  • PDF

A Study on the step response characteristics in shielded resistor divider for full lightning impulse voltage (전파 뇌충격전압 측정용 쉴드저항분압기의 직각파 특성에 관한 연구)

  • 김익수;이형호;조정수;박정후
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.283-288
    • /
    • 1996
  • This paper presents the development technology of standard shielded resistor divider for full lightning impulse voltage. The ability of large-capacity power apparatus to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently international standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisons have already completed worldwide, i.e. Europe, Japan, America etc., In this viewpoint, we have also investigated the step response of the standard shielded resistor divider, which satisfies the IEC recommendation.

  • PDF

A design of actively shielded superconducting MRI magnet (능동차폐형 초전도 MRI 마그네트의 설계)

  • 진홍범;류강식;송준태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.24-29
    • /
    • 1996
  • Magnetic field theories for the design of highly homogeneous magnet are introduced and a nonlinear optimization method for the design of actively shielded superconducting magnet is presented. The presented design method can optimize both main coil and shielding coil simultaneously by setting constraints on stray field intensity at a specified distance from the magnet center. A 2-Tesla actively shielded superconducting magnet, with 90cm bore diameter, is designed using the presented method. The field homogeneity is 2ppm/30cm DSV and the 5 gauss stray field contour is within 4m axially and 3m radially from the magnet center. (author)., 7 refs., 6 figs., 3 tabs.

  • PDF

Analysis of CRUD Flake Applied to Abnormal High Beam Current by Shielded-EPMA

  • Jung, Y.H.;Baik, S.J.;Ahn, S.B.
    • Corrosion Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.265-271
    • /
    • 2018
  • CRUD specimens, scraped from twice-burned fuel cladding in the Korean Nuclear Power Plant, were analyzed using Shielded-EPMA. The principal elements of the CRUD were identified as Ni and Fe, at an approximate ratio of 1.3 Ni/Fe. To investigate the morphology and composition of the pure metallic materials in the CRUD, coolant impurities must be removed. This can be accomplished by increasing the EPMA current to an abnormally high intensity until the impurities are melted. Normally, EPMA applications are performed at conditions of 20 kV voltage and 20 nA current. But in our study, the applied current was increased up to 1200 nA, over time increments ranging from 5 to 30 seconds. This technique was performed by opening an adjustable aperture for the gun alignment. Results showed impurities contained in the CRUD material disappeared and pure metal materials, e.g., Ni and Fe, remained. This method presents an innovative way to analyze CRUD.

Analysis of the Coplanar Waveguide Shielded by Rectangular Waveguide (구형 도파관으로 차폐된 코플래너 도파관 해석)

  • 황정섭;이상설
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.7
    • /
    • pp.19-25
    • /
    • 1993
  • By using the point matching method, the coplanar waveguide shielded by the rectangular waveguide has been analyzed. The particular potential solution of C.P.W has been obtained from the boundary condition by using the point matching method. The line capacitance has been obtained from the total charge of the center conductor per length. The effective dielectric constant and the line impedance have been obtained from the line capacitance of C.P.W.

  • PDF