• Title/Summary/Keyword: Shield Effectiveness

Search Result 76, Processing Time 0.02 seconds

The First Case Study of TBM Pre-Excavation Type 2-Arch Tunnel in Korea (국내 최초 TBM선굴진 2-Arch터널 설계사례 연구)

  • Hyung-Ryul Kim;Sang-Jun Jung;Jun-Ho Kang
    • Tunnel and Underground Space
    • /
    • v.33 no.4
    • /
    • pp.255-264
    • /
    • 2023
  • As the demand for urban underground space increases recently, urban tunnel planning is actively progressing. In the urban area, a underground station is planned in consideration of the living environment of residents, and 2-arch tunnel is applied for the stability of existing structures and reduction of environmental damage. However, since the depth of weak rock mass is deeply distributed in the urban area due to severe weathering, careful planning is required to secure tunnel stability. In addition, if TBM mechanical excavation is applied as the main tunnel excavation method considering the composite ground in urban area, the construction connectivity with the 2-arch tunnel of the NATM concept may be deteriorated. In this study, the design case of applying TBM pre-excavation type 2-arch tunnel for the first time in Korea was mainly described. The main considerations for the segment design of TBM pre-excavation type 2-arch tunnel were explained for side tunnels. Also, a stability analysis was conducted to verify the effectiveness and adequacy of the TBM pre-excavation type 2-arch tunnel.

Analysis of Indirect Lightning Impact on Aircraft Shielded Cable Structure in accordance with RTCA DO-160G Sec. 22 (항공기용 차폐 케이블의 구조에 따른 RTCA DO-160G Sec. 22 간접낙뢰 영향성 분석)

  • Sung-Yeon Kim;Tae-Hyeon Kim;Min-Seong Kim;Wang-Sang Lee
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.35-45
    • /
    • 2023
  • In this paper, we analyze the influence of indirect lightning strikes based on the structure of shielded cables used in an aircraft and propose a cable structure to enhance shielding effectiveness. Cables in an aircraft account for the largest proportion among components and play a crucial role in connecting aircraft frames and electronic devices; thus, making them highly influential. In particular, indirect lightning strike noise can lead to malfunctions and cause damage in aircraft electronic equipment, making the utilization of shielded cables essential for mitigating damage caused by indirect lightning strike noise. We conducted an analysis of the impact of indirect lightning strikes on aircraft shielded cables considering factors, such as the presence of shielding layers, core, and insulation in the cable structure. Furthermore, we validated our findings through simulations and experiments by applying the internationally recognized standard for indirect lightning, RTCA DO-160G Sec. 22.

Development of Shielding using Medical Radiological Contrast Media; Comparison Analysis of Barium Sulfate Iodine Shielding ability by Monte Carlo Simulation (의료방사선 조영제를 이용한 차폐체 개발; 몬테카를로 시뮬레이션을 통한 황산바륨과 요오드의 차폐능 비교분석)

  • Kim, Seon-Chil
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.5
    • /
    • pp.329-334
    • /
    • 2017
  • The purpose of this study is to estimating the possibility of manufacturing radiation shielding sheet by searching for environmentally friendly materials suitable for medical environment of medical radiation shielding. There are many tungsten products which are currently used as shielding materials in place of lead, but there are small problems in the mass production of lightweight shielding sheets due to economical efficiency. To solve these problems, a lightweight, environmentally friendly material with economical efficiency is required. In this study, Barium sulphate and Iodine were proposed. Both materials are already used as contrast medias in radiography, and it is predicted that the shielding effect will be sufficient in a certain region as a shielding material because of the characteristic of absorbing radiation. Therefore, in this study, we used a Monte Carlo simulation to simulate radiation shielding materials. When it is a contrast agent such as Barium sulfate and Iodine, the radiation absorption effect in the high energy region appears greatly, and the effectiveness of the two shielding substance in the energy region of the star with thickness of 120 kVp is also evaluated in the medical radiation imaging region. Simulated estimation results it was possible to estimate the effectiveness of shielding for all two substances. Iodine has higher shielding effect than barium sulfate, 0.05 mm thick appears great effect. Therefore, the Monte Carlo simulation confirms that iodine, which is a radiological contrast agent, is also usable as barium sulfate in the production of radiation shielding sheets.

An Effect Analysis on the Management and Service Evaluation System for Bus Company (시내버스업체의 경영 및 서비스 평가제도 도입 효과분석)

  • Kim, Jeom-San;Jo, Hye-Jeong;Park, Jun-Sik
    • Journal of Korean Society of Transportation
    • /
    • v.25 no.5
    • /
    • pp.43-55
    • /
    • 2007
  • Gyeonggi-do has conducted bus management and service evaluation of bus operating company since 2005 under the law for promoting public transportation. The evaluation results are used for improving bus service, making policy, and estimating incentives to bus companies. A lot of cost and man-month are needed to evaluate bus management and service for bus operating company, and many companies are against the evaluation. Therefore, the effect analysis on evaluation system should be followed to maintain it. This research results in the evaluation system has positive effects through quantitative and qualitative analysis. The data of bus company's operation condition in 2005 and 2006 are used for a comparative analysis. From the survey result for the company, bus drivers, and administrators, it results that positive effects are predominant. The results of this research could be used for a shield against some criticism about appropriateness of the evaluation criteria and effectiveness of the evaluation system. For improving bus service, evaluation items and criteria could be added or adjusted based on this research.

Switching and Leakage-Power Suppressed SRAM for Leakage-Dominant Deep-Submicron CMOS Technologies (초미세 CMOS 공정에서의 스위칭 및 누설전력 억제 SRAM 설계)

  • Choi Hoon-Dae;Min Kyeong-Sik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.3 s.345
    • /
    • pp.21-32
    • /
    • 2006
  • A new SRAM circuit with row-by-row activation and low-swing write schemes is proposed to reduce switching power of active cells as well as leakage one of sleep cells in this paper. By driving source line of sleep cells by $V_{SSH}$ which is higher than $V_{SS}$, the leakage current can be reduced to 1/100 due to the cooperation of the reverse body-bias. Drain Induced Barrier Lowering (DIBL), and negative $V_{GS}$ effects. Moreover, the bit line leakage which may introduce a fault during the read operation can be eliminated in this new SRAM. Swing voltage on highly capacitive bit lines is reduced to $V_{DD}-to-V_{SSH}$ from the conventional $V_{DD}-to-V_{SS}$ during the write operation, greatly saving the bit line switching power. Combining the row-by-row activation scheme with the low-swing write does not require the additional area penalty. By the SPICE simulation with the Berkeley Predictive Technology Modes, 93% of leakage power and 43% of switching one are estimated to be saved in future leakage-dominant 70-un process. A test chip has been fabricated using $0.35-{\mu}m$ CMOS process to verify the effectiveness and feasibility of the new SRAM, where the switching power is measured to be 30% less than the conventional SRAM when the I/O bit width is only 8. The stored data is confirmed to be retained without loss until the retention voltage is reduced to 1.1V which is mainly due to the metal shield. The switching power will be expected to be more significant with increasing the I/O bit width.

Characteristics of Intrusion MO and Perception of Target Hardening of Burglars (침입절도범 재소자의 수법 특성과 타겟하드닝 관련 인식)

  • Park, Hyeonho;Kim, Kang-Il;Kim, Hyo-gun
    • Korean Security Journal
    • /
    • no.60
    • /
    • pp.33-61
    • /
    • 2019
  • It is quite difficult to actually prove the effectiveness of so-called target-hardening, one of the various strategies used to reduce crime, one of the serious problems in society recently. In particular, three to five minutes is often used as golden time for intruders to give up or stop, which is based on foreign and some indirect research cases in Korea, but there were no studies that more directly identified the average break-in operation time or the abandonment time based on the elapsed time when the shield hardware resists intruders. This study was the first of its kind in Korea to investigate and verify samples of 90 inmates of break-in burglars who were imprisoned in August 2018 by profiling the average criminal experience, education level, age, height and weight of typical Korean professional break-in thieves, and specific criminal methods, average break-in operation time, and the criteria for giving up if not breached. According to the analysis results, in the survey on the number of pre-invasion theft crimes by intruders, many of the respondents who participated in the survey were criminals of professional invasions, and by their physical characteristics, there was not much difference from ordinary adult men. Residential facilities were the highest in the world, followed by commercial and educational facilities. According to the survey on the types of facilities that committed intrusion into residential facilities, it was not safe to say that single-family housing accounted for the largest portion of single-family housing, multi-family housing, apartment high-rise (more than three stories), and apartment low-rise (more than one to three stories) among residential facilities, and that the ratio of apartment high-rise was higher than expected. Based on the average time required to break into a place for an intrusion crime, it is assumed that the psychological time worked in a place where the break-in was difficult, since the break-in was not performed while measuring the time of the break-in operation. In the case of time to give up a crime, more than half of the respondents said they would give up the crime even in less than four minutes, suggesting that a significant number of intrusive crimes can be prevented even if the facility has four minutes of intrusion resistance. This proves that most intruders will give up the break-in if the break-in resistance performance of the security facility is exercised for more than five minutes.