• 제목/요약/키워드: Shell and tube heat exchanger

검색결과 115건 처리시간 0.027초

쉘-튜브 열교환기에서 배플 인자에 따른 열전달 특성 연구 (Research of Heat Transfer Characteristics with Baffle Parameters in Shell and Tube Heat Exchanger)

  • 오규남;전용두;이금배
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.599-604
    • /
    • 2010
  • Because shell and tube heat exchanger is widely used in industry, extensive research work is going on to improve the thermal efficiency and to understand the key design parameters. In this study, the main design parameters of the baffle, depending on the height and number of baffle for heat recovery are being studied. Numerical results are in good agreement with the experimental results with a slight discrepancy of 3%, which is quite resonable. The heat transfer rate and pressure drop increase depending on increasing of number of baffles and baffle height, but increase of the heat transfer rate is limited due to contact area with the tube, flow separation, fluid residual time, turbulence and velocity.

동일 전열면적을 갖는 용접식 판형열교환기와 관류형 열교환기의 성능 비교 (Performance Comparison of a Welded Plate Heat Exchanger and Shell and Tube Heat Exchanger with Same Heat Transfer Area)

  • 함정균;김민준;안성국;조홍현
    • 한국지열·수열에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.46-54
    • /
    • 2019
  • In this study, the performance of a shell and tube heat exchanger (STHE) and welded plate heat exchanger (WPHE) was measured experimentally. The pass numbers of the STHE was changed by 1, 2 and 4. As a result, the WPHE showed 2.1 times higher heat exchange capacity than that of the STHE. In case of pressure drop, the STHE with 1 and 2 pass number has a lower pressure drop than the WPHE, while the STHE with 4 pass presented higher pressure drop than the WPHE. The performance index considering the heat exchange capacity and pump consumption power, showed in oder of STHEPass1 > STHEPass2 > W PHE > STHEPass4 under the same flow rate. Therefore, when the WPHE was designed optimally under same operating condition with STHE, the maintenance fee and space can be reduced effectively by using the WPHE.

수직형 순환유동층 열교환기에서의 유체유동과 온도장의 수치해석 (Numerical analysis of fluid flow and thermal fields in the vertical fluidized bed heat exchanger)

  • 이병창;강호근;이명성;안수환
    • 동력기계공학회지
    • /
    • 제16권4호
    • /
    • pp.24-29
    • /
    • 2012
  • The numerical analysis by using CFX 11.0 commercial code was done for prediction of fluid flow and thermal field in the vertical heat exchanger. The present experimental studies were also conducted to investigate the effects of circulating solid particles on the fluid flow and temperatures in the fluidized bed vertical shell and tube type heat exchanger with counterflow, at which the solid particles of glasses (3 $mm{\Phi}$) were used in the fluidized bed with a smooth tube. The effect of circulation on the distance(L) of tube inlet and baffle plate was also examined. The present experimental and numerical results showed that the particles in the distance (Ds) of 15 mm showed a more efficient circulation without stacked the space and the LMTD(Log Mean Temperature Difference) in the fluidized bed type was much lower than that in the typical type shell and tube heat exchanger.

쉘-튜브 열교환기에서의 쉘쪽 유체의 특성에 따른 열교환기 성능 변화 예측 사례 (Shell and Tube Heat Exchanger Performance Estimation by Changing Shell-side Fluid Characteristics)

  • 백승환;정영석;조기주
    • 한국추진공학회지
    • /
    • 제23권2호
    • /
    • pp.27-37
    • /
    • 2019
  • 쉘-튜브 열교환기가 나로우주센터 추진기관종합시험장(PSTC)에 설치되었으며, 이 열교환기는 극저온의 헬륨을 고온의 열매유와 열교환하여 약 500 K 까지 가열시키는 역할을 한다. 열교환기에서 토출되는 헬륨의 온도가 설계보다 100 K 낮게 나옴에 따라, 성능저하의 원인으로 열매유의 격막효과가 지목되었다. CFD 해석을 통해 격막효과의 유무를 확인하였으며, 격막효과에 의한 열교환기 성능저하는 미미한 것으로 판단되었다. 추가적으로 열교환기의 성능을 증가시키기 위하여 열매유 교체에 따른 열교환기 성능 변화를 알아보았다. 열매유를 사용하는 열교환기의 성능향상을 위해서는 500 K 부근에서 점성이 낮아야 하고, 열전도도가 높아야 한다는 것을 확인할 수 있었다. 추진기관종합시험장에서 운용된 극저온 헬륨과 고온 열매유의 열교환 시스템의 시험 결과를 본 논문에서 확인할 수 있다.

세척이 가능한 원통 코일형 열교환기의 파울링 특성에 관한 연구 (Fouling Characteristics of Washable Shell and Coil Heat Exchanger)

  • 황준현;나병철;오세기;구경민;이재근;안영철
    • 설비공학논문집
    • /
    • 제27권2호
    • /
    • pp.69-74
    • /
    • 2015
  • In this work, we studied the shell and helically coiled tube heat exchangers. Shell and coil heat exchangers with different rate of water flow and plate heat exchanger with same capacity were tested for condensing conditions. We proposed design guide using modified Wilson plot method. We compared fouling characteristics between shell and coil heat exchanger and plate heat exchanger, when they were washed and were not washed. The shell and coil heat exchanger showed 120% of higher saturated fouling resistance value and 4% of better heat transfer ratio than the plate heat exchanger.

모듈형 관군 열교환기에서의 관 형상에 따른 열전달 및 압력강하 특성에 관한 연구 (Heat Transfer and Pressure Drop Characteristics for Various Tube Geometries in Modular Tube Bundle Heat Exchanger)

  • 윤준식;박병규;김찬중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.105-111
    • /
    • 2000
  • A numerical study has been performed to obtain the heat transfer and pressure drop characteristics for shell-and-tube heat exchanger with various shapes of tubes. The Tubes have variation of Aspect Ratio, Pitch and Rotation. Results are presented as plots of Colburn j factor and friction factor f against Aspect Ratio, Pitch and Rotation. As Aspect Ratio increases, j factor and f factor decreases. As Pitch increases, j factor decreases. j/f have optimized Pitch for each Aspect Ratio. Accordingly, there is fitness of Aspect Ratio and Pitch fur most effective cases. The Rotation of tubes are of no meaning for both heat transfer and pressure drop.

  • PDF

소형 쉘앤튜브형 열교환기의 운전 조건에 따른 열유동 거동 특성 해석 (Analysis on Characteristics of Behavior of Thermal Flow According to Operation Conditions of Small-sized Shell and Tube-type Heat Exchanger)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제26권6_2호
    • /
    • pp.1109-1115
    • /
    • 2023
  • The shell and tube-type heat exchanger was the most utilized in industrial field because of its simple structure and wide operation conditions and so on. This study was performed to investigate the characteristics of behavior of thermal flow according to operation condition of small-sized shell and tube-type heat exchanger. The operation conditions, here, were set up to flow rate of hot air with temperature of 100℃, number of baffle and cut rate of baffle(BCR) using numerical analysis. As the results, both mean relative pressure and relative pressure drop was increased with quadratic curve in case of less than BCR 25%, however, decreased linearly in case of more than BCR 25%. The collision with first baffle by flow velocity and temperature, of hot air, respectively, was depended on BCR. Further it showed that the behaviors between flow velocity and temperature were almost similar.

Tube의 형상 및 표면특성에 의한 Shell-and-Tube 열교환기의 열전달 성능 (The Performance in Shell-and-Tube Heat Exchangers with Configuration and Surface Characteristics of Tube)

  • 김성일;박기호;전원표
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2316-2321
    • /
    • 2008
  • This paper presents an improved performance of heat transfer for shell-and-tube and thermal analysis based on the Bell-Delaware method for single tube. Heat transfer has been compared for a smooth tube, helical tube and surface-coated tube. In general, the results showed that properly designed helical tube and surface-coated tube offer a significant improvement in heat transfer. The numerical results derived from the Bell-Delaware method for the shell-side heat transfer coefficient were verified with experimental results. The thermal analysis aids significantly in the solution of the design problem.

  • PDF

Thermal Performance of a Spirally Coiled Finned Tube Heat Exchanger Under Wet-Surface Conditions

  • Wongwises Somchai;Naphon Paisarn
    • Journal of Mechanical Science and Technology
    • /
    • 제20권2호
    • /
    • pp.212-226
    • /
    • 2006
  • This paper is a continuation of the authors' previous work on spiral coil heat exchangers. In the present study, the heat transfer characteristics and the performance of a spirally coiled finned tube heat exchanger under wet-surface conditions are theoretically and experimentally investigated. The test section is a spiral-coil heat exchanger which consists of a steel shell and a spirally coiled tube unit. The spiral-coil unit consists of six layers of concentric spirally coiled finned tubes. Each tube is fabricated by bending a 9.6 mm diameter straight copper tube into a spiral-coil of four turns. The innermost and outermost diameters of each spiral-coil are 145.0 and 350.4 mm, respectively. Aluminium crimped spiral fins with thickness of 0.6 mm and outer diameter of 28.4 mm are placed around the tube. The edge of fin at the inner diameter is corrugated. Air and water are used as working fluids in shell side and tube side, respectively. The experiments are done under dehumidifying conditions. A mathematical model based on the conservation of mass and energy is developed to simulate the flow and heat transfer characteristics of working fluids flowing through the heat exchanger. The results obtained from the present model show reasonable agreement with the experimental data.

원통-다관형 열교환기의 다관측 입출구 유동 특성의 실험적 연구 (Experimental Study of Inlet/Outlet Flow Characteristics in Tube-side of Shell and Tube Heat Exchanger)

  • 도흔승;왕개;박승하;김형범
    • 대한기계학회논문집B
    • /
    • 제38권7호
    • /
    • pp.581-588
    • /
    • 2014
  • 본 논문에서는 원통-다관형 열교환기의 다관측 유량의 분배도 향상을 위해 다공성 배플 유무에 따른 입구 및 출구부의 유동 특성을 실험적으로 연구하였다. 원통 및 다관측 유량의 분배성능은 원통-다관형 열교환기의 성능에 직간접적인 영향을 준다. 실험 연구를 위하여 원형 크기의 1/3로 축소한 실험 모델을 제작하였고, 60, 80, 90 LPM의 유량 조건에서 다공성 배플의 유무에 따른 다관측의 분배 성능을 입자화상속도기법을 이용한 입구 및 출구부의 속도장 측정을 통해 확인하였다. 연구로부터 절대 불균일 분배도를 계산하여 정량적으로 다공성 배플이 유량의 분배도에 주는 영향을 확인하였다. 측정 결과로부터 유량에 상관없이 배플을 설치하였을 경우 74%의 절대 불균일 분배도의 감소 효과를 가졌다.