• Title/Summary/Keyword: Shear-Transfer

Search Result 548, Processing Time 0.025 seconds

Experimental Study on Local Convective Mass Transfer From a Circular Cylinder in Uniform Shear Flow (균일 전단류내에 있는 원봉주위의 국소 대류 물질 전달에 관한 실험적 연구)

  • 류명석;성형진;정명균
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.4
    • /
    • pp.789-798
    • /
    • 1989
  • A naphthalene sublimation technique based on the heat/mass transfer analogy is used to investigate the circumferential mass transfer from a circular cylinder in an approaching uniform shear flow. Experiments are performed in a wind tunnel (450*450m $m^{2}$ with a shear flow generator which is specially manufactured for generating variable shear rates(S). The effects of an approaching shear flow are correlated with mass transfer coefficients. It is found that the local mass transfer rate on a circular cylinder is characterized with the shear parameter $K^{d}$ defined as Sd/ $U^{c}$ , where d is the radius of cylinder and $U^{c}$ is the approaching velocity at the center of cylinder. The angle on the corresponding to minimum Sherwood number is approximately proportional to the shear parameter on an upper and down number is approximately proportional to the shear parameter on an upper and down circular cylinder (0< $K^{d}$ <0.132). Changes on the averaged mass transfer rate are not significant for small $K^{d}$ , which are slightly proportional to K$d^{2}$ but the local mass transfer rates are significantly changed with the approaching shear flow.

Two-way Shear Strength Evaluation of Transfer Slab-Column Connections Through Nonlinear FE Analysis (비선형유한요소해석을 통한 전이슬래브-기둥 접합부의 2면 전단강도 평가)

  • Jeong, Seong-Hun;Kang, Su-Min
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.6
    • /
    • pp.315-329
    • /
    • 2018
  • Recently, RC transfer slab systems have been used widely to construct high-rise wall-type apartments for securing parking space or public space. However, it is problem that the design method and structural performance evaluation method developed for thin RC flat slab are still used in the design of the transfer slab whose thickness is very thick and therefore structural behavior is expected to be different from RC flat slab. Thus, for the rational design of the transfer slab, the ultimate shear behavior of the RC transfer slab system is required to be analyzed properly. Accordingly, in the present study, the two-way shear behavior of the transfer slab was analyzed using nonlinear FEM according to various design parameters such as thickness of the transfer slab, strength of concrete, shear span ratio, and reinforcement ratio. In addition, the two-way shear strength evaluations of RC transfer slab by the existing evaluation methods were verified by comparing those with the results of nonlinear FEM analysis.

Heat Transfer Coefficient and Shear Factor Subjected to Both Oscillating Flow and Oscillating Pressure in Pulse Tubes (주기적인 유동과 압력의 변화를 수반하는 맥동관의 열전달계수와 전단계수)

  • Jeong, Eun-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.220-227
    • /
    • 2007
  • Heat transfer and momentum transfer under conditions of both oscillating flow and oscillating pressure within pulse tubes show very different behavior from those for steady state conditions. The analytic solutions of axial velocity and temperature of the gas within pulse tubes were obtained by assuming that the variations in pressure and temperature were purely sinusoidal and small. The shear stress and the heat flux at the tube wall obtained from the solutions are expressed in terms of the cross-sectional averaged velocity, the difference between mean temperature and instantaneous cross-sectional averaged temperature and the difference between mean pressure and instantaneous pressure. It is shown that the complex shear factor, which has been applied to momentum transfer of incompressible oscillating flow, and the complex Nusselt number, which has been applied to either heat transfer with oscillating pressure only or heat transfer of incompressible oscillating flow, could also be used for momentum transfer and heat transfer subjected to both oscillating flow and oscillating pressure, respectively.

Free vibration analysis of asymmetric shear wall-frame buildings using modified finite element-transfer matrix method

  • Bozdogan, Kanat B.
    • Structural Engineering and Mechanics
    • /
    • v.46 no.1
    • /
    • pp.1-17
    • /
    • 2013
  • In this study, the modified finite element- transfer matrix methods are proposed for free vibration analysis of asymmetric structures, the bearing system of which consists of shear wall-frames. In the study, a multi-storey structure is divided into as many elements as the number of storeys and storey masses are influenced as separated at alignments of storeys. The shear walls and frames are assumed to be flexural and shear cantilever beam structures. The storey stiffness matrix is obtained by formulating the governing equation at the center of mass for the shear walls and the frames in the i.th floor. The system transfer matrix is constructed in the dimension of $6{\times}6$ by transforming the obtained stiffness matrix. Thus, the dimension, which is $12n{\times}12n$ in classical finite elements, is reduced to the dimension of $6{\times}6$. To study the suitability of the method, the results are assessed by solving two examples taken from the literature.

The effect of the shear-rate dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement (전단율에 의존적인 비뉴턴 유체의 열전도율이 열전달 향상에 미치는 영향)

  • Sin, Se-Hyeon;Lee, Seong-Hyeok;Son, Chang-hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1717-1724
    • /
    • 1996
  • The present study investigates the effect of the shear rate-dependent thermal conductivity of non-Newtonian fluids on the heat transfer enhancement in a pipe flow. An axially-constant heat flux boundary condition was adopted in the thermal fully developed region. The present analytical results of Nusselt numbers for various non-Newtonian fluids show heat transfer enhancement over those of a shear rate-independent thermal conductivity fluids. The present analytical results showed good agreement with the previous experiments which excluded the temperature-dependent viscosity effect on heat transfer. This study also proposes the use of a shear rate-dependent thermal conductivity fluids in the design of a heat exchanger for heat transfer enhancement as well as reduction of fouling.

Numerical heat transfer in a rectangular duct with a non-newtonian fluid with shear-rate dependent thermal conductivity (직사각형 덕트에서 전단율에 의존적인 열전도율을 갖는 비뉴턴 유체의 열전달 향사아에 관한 수치적 연구)

  • Kim, Byeong-Seok;Sin, Se-Hyeon;Son, Chang-Hyeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.6
    • /
    • pp.773-778
    • /
    • 1997
  • The present study investigates the effect of the shear rate-dependent thermal conductivity of non-newtonian fluids on the heat transfer enhancement in a 2:1 rectangular duct flow. An axially-constant heat flux and a peripherally-constant temperature boundary conditions(H1) was adopted for a top-wall-heated configuration. The present numerical results of Nusselt numbers for SRDC(Separan) show heat transfer enhancement over those of SRIC. The Nusselt numbers increased linearly as Reynolds numbers increased. The heat transfer enhancement is due to an increased thermal conductivity near the wall, which is attributed to the shear rate-dependence.

Characteristics of Vertical Vibration Transfer in Vertical Way according to Shear Wall Apartment Structures due to Heel-drop Impact (발 뒤꿈치 충격에 의한 전단벽식 공동주택 수직진동의 수직방향 진동전달 특성)

  • Chun, Ho-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.70-73
    • /
    • 2006
  • Recently, several researches have been performed on the prediction of vertical vibration on structures by using an analytical method. However, these studies have been focused on mainly the vibration analysis through analytical modeling of structures. This study aims to investigate the characteristics of vertical vibration transfer in terms of the directions of transfer(upward transfer and downward transfer) on the shear wall building structures due to heel-drop impact forces. In order to examine the characteristics of vertical vibration transfer, the mode analysis and the impact experiment were conducted several times on two shear wall building structures. The results of this study suggest that the characteristics of vertical vibration transfer are similar in terms of the directions of transfer.

  • PDF

Experimental study on shear damage and lateral stiffness of transfer column in SRC-RC hybrid structure

  • Wu, Kai;Zhai, Jiangpeng;Xue, Jianyang;Xu, Fangyuan;Zhao, Hongtie
    • Computers and Concrete
    • /
    • v.23 no.5
    • /
    • pp.335-349
    • /
    • 2019
  • A low-cycle loading experiment of 16 transfer column specimens was conducted to study the influence of parameters, likes the extension length of shape steel, the ratio of shape steel, the axial compression ratio and the volumetric ratio of stirrups, on the shear distribution between steel and concrete, the concrete damage state and the degradation of lateral stiffness. Shear force of shape steel reacted at the core area of concrete section and led to tension effect which accelerated the damage of concrete. At the same time, the damage of concrete diminished its shear capacity and resulted in the shear enlargement of shape steel. The interplay between concrete damage and shear force of shape steel ultimately made for the failures of transfer columns. With the increase of extension length, the lateral stiffness first increases and then decreases, but the stiffness degradation gets faster; With the increase of steel ratio, the lateral stiffness remains the same, but the degradation gets faster; With the increase of the axial compression ratio, the lateral stiffness increases, and the degradation is more significant. Using more stirrups can effectively restrain the development of cracks and increase the lateral stiffness at the yielding point. Also, a formula for calculating the yielding lateral stiffness is obtained by a regression analysis of the test data.

A Study on Heat Transfer Enhancement for a Shear-Thinning Fluid in Triangular Ducts (삼각형 단면 덕트 내의 Shear-Thinning 유체에 대한 열전달 촉진에 관한 연구)

  • Lee, Dong-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.3808-3814
    • /
    • 2011
  • The prediction of heat transfer and pressure drops in the exchanger passages is a clue to the problem of heat exchanger design. In order to make such predictions for non-Newtonian fluids, it is necessary to know the relation between the viscous properties of the fluid and the wall shear rate in the duct. This study deals with the limits of validity of the power law equation. The useful methodology of the present research involves a consideration of a more general equation which has power law and Newtonian behavior as asymptotes. It isconcluded that use of the power law equation outside of its applicability range can lead to serious errors inpredicting the heat transfer and pressure drops. The present computational results of the friction factors times Reynolds number for shear-thinning fluid flows in a triangular duct are compared with previous published results, showing agreement with 0.13 % in Newtonian region and 2.85 % in power law region. These shear-thinning fluid results also showed the 12% increase of convective heat transfer enhancement compared with Newtonian heat transfer.

Shear transfer mechanism in connections involving concrete filled steel columns under shear forces

  • De Nardin, Silvana;El Debs, Ana Lucia H.C.
    • Steel and Composite Structures
    • /
    • v.28 no.4
    • /
    • pp.449-460
    • /
    • 2018
  • This paper reports the experimental results of three through bolt beam-column connections under pure shear forces using modified push-out tests. The investigated specimens include extended end-plates and six through-bolts connecting square concrete-filled steel tubular column (S-CFST) to steel beams. The main goal of this study is to investigate if and how the mechanical shear connectors, such as steel angles and stud bolts, contribute to the shear transfer mechanisms in the steel-concrete interface of the composite column. The contribution of shear studs and steel angles to improve the shear resistance of steel-concrete interface in through-bolt connections was investigated using tests. The results showed that their contribution is not significant when the beam-column connection is included in the push-out tests. The specimens failed by pure shear of the long bolts, and the ultimate load can be predicted using the shear resistance of the bolts under shear forces. The predicted values of load allowed obtaining a good agreement with the tests results.