• 제목/요약/키워드: Sharp Curve

검색결과 103건 처리시간 0.022초

Auto-focus Algorithm Using Variance of Difference (VoD) of Adjacent Pixels (인근 픽셀 차이 값의 분산(VOD)을 이용한 자동 초점 조절 알고리즘)

  • 이형근;노경완김충원
    • Proceedings of the IEEK Conference
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.935-938
    • /
    • 1998
  • In this paper, we propose a new auto focus algorithm using variance which estimate spread characteristic of image. In the proposed algorithm, the focus value is calculated via variance of difference between two adjacent pixels. This algorithm, we propose, show much more sharp focus curve than any other algorithms. It is shown experimentally that the proposed auto focus algorithm can be a efficient alternative to existing Tenengrad-based auto focusing algorithms.

  • PDF

ON PARTIAL SOLUTIONS TO CONJECTURES FOR RADIUS PROBLEMS INVOLVING LEMNISCATE OF BERNOULLI

  • Gurpreet Kaur
    • Korean Journal of Mathematics
    • /
    • 제31권4호
    • /
    • pp.433-444
    • /
    • 2023
  • Given a function f analytic in open disk centred at origin of radius unity and satisfying the condition |f(z)/g(z) - 1| < 1 for a analytic function g with certain prescribed conditions in the unit disk, radii constants R are determined for the values of Rzf'(Rz)/f(Rz) to lie inside the domain enclosed by the curve |w2 - 1| = 1 (lemniscate of Bernoulli). This, in turn, provides a partial solution to the conjectures and problems for determination of sharp bounds R for such functions f.

Studies on the Quality Control of Insulin Radioimnunoassay Kit (I) -Pitfalls in Radioimmunoassay of Insulin-

  • Lee, Kyung-Hee;Awh, Ok-Doo;Kim, Jae-Rok
    • Nuclear Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.223-229
    • /
    • 1978
  • A typical abnormal standard dose response curve of nearly convex form. often encountered in insulin radioimmunoassay (IRIA) has been analyzed by varying incubation conditions. The cause of such abnormality has been turned out to be the results of an incomplete equilibrium between the two reactants. By careful control of the temperature of serum sample an immediate cause of sharp deviation of B/F value of tile sample tube from the measurable range in the standard curve has also been investigated. The two main troubles have been proven to be stemed from incubation conditions. Incubation at 4$^{\circ}C$ for 48 hrs is emphasized for IRIA.

  • PDF

A Study on the Parameters Effecting on the Derailment Factor of Running Train on the Curved Track (곡선부에서 탈선계수에 영향을 미치는 매개변수들에 대한 연구)

  • Song, Bong-Hwan;Yang, Shin-Chu;Kang, Yun-Suk
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.348-356
    • /
    • 2004
  • In this paper, Analysis of parameters effecting on the derailment factor was conducted in oder to deduce technical requisites have to be reflected in design of Track and rolling-stocks because it is important to grasp the risk of derailment quantitatively. And then go far toward becoming practical study with that select two section of sharp curved track of actual train in service, incheon Metro Line 1 and make field research in condition of vehicles and track and analysis As a result of parameter study, the following conclusions were obtained. The radius of curve and Cant is in inverse proportion to the derailment factor, but as train operation velocity, standard deviation of alignment irregularity and the ratio lateral force : wheel load of the inside track increase, the derailment factor rise. In the investigation for the derailment safety of incheon Metro Line 1, the derailment factor was below 0.43 in both section R=200 and R=300, so that it proved safe compare with allowance limits 0.8, but it appeared that risk of the derailment in second transition curve is the highest among the entire curve.

  • PDF

Study of Al-Alloy Foam Compressive Behavior Based on Instrumented Sharp Indentation Technology

  • Kim Am-Kee;Tunvir Kazi
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.819-827
    • /
    • 2006
  • The stress-strain relation of aluminum (Al) alloy foam cell wall was evaluated by the instrumented sharp indentation method. The indentation in a few micron ranges was performed on the cell wall of Al-alloy foam having a composition or Al-3wt.%Si-2wt.%Cu-2wt.%Mg as well as its precursor (material prior to foaming). To extract the stress-stram relation in terms of yield stress ${\sigma}_y$, strain hardening exponent n and elastic modulus E, the closed-form dimensionless relationships between load-indentation depth curve and elasto-plastic property were used. The tensile properties of precursor material of Al-alloy foam were also measured independently by uni-axial tensile test. In order to verify the validity of the extracted stress-strain relation, it was compared with the results of tensile test and finite element (FE) analysis. A modified cubic-spherical lattice model was proposed to analyze the compressive behavior of the Al-alloy foam. The material parameters extracted by the instrumented nanoindentation method allowed the model to predict the compressive behavior of the Al-alloy foam accurately.

A Feasibility Study of Simultaneous Measurement of Gas-Liquid Two-Phase Flowrate and Quality with a Sharp-Edged Orifice (차압유량계를 이용한 기액 2상유량 및 건도의 동시측정 가능성에 관한 연구)

  • 이상천;오홍의;김중엽
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제10권3호
    • /
    • pp.335-342
    • /
    • 1986
  • The feasibility of simultaneous measurement of gas-liquid tow-phase flowrate and quality with a sharp-edged orifice has been investigated. Instantaneous pressure drop curves were monitored for various combinations of gas and liquid flowrates in the bubbly flow regime and some statistical properties of the curves were calculated. The time-averaged value of pressure drop increases with increasing gas and liquid flowrate, whereas the mean amplitude and the intensity of fluctuation monotonically increase as void fraction becomes larger in the flow regime. The statistical furctions for the instantaneous curves indicate a consistent pattern throughout the flow regime and the probability density function, which as a single-peaked and symmetrical distribution, is well predicted by the Gaussian distribution function. The results indicate that simultaneous determination of two-phase flowrate and quality may be possible based upon the statistical analysis of instaneous pressure drop curves measured in a sharp-edged orifice.

Efficient Implementations of Index Calculation Methods of Elliptic Curves using Weil's Theorem (Weil 정리를 이용한 효율적인 타원곡선의 위수 계산법의 구현)

  • Kim, Yong-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제11권7호
    • /
    • pp.693-700
    • /
    • 2016
  • It is important that we can calculate the order of non-supersingular elliptic curves with large prime factors over the finite field GF(q) to guarantee the security of public key cryptosystems based on discrete logarithm problem(DLP). Schoof algorithm, however, which is used to calculate the order of the non-supersingular elliptic curves currently is so complicated that many papers are appeared recently to update the algorithm. To avoid Schoof algorithm, in this paper, we propose an algorithm to calculate orders of elliptic curves over finite composite fields of the forms $GF(2^m)=GF(2^{rs})=GF((2^r)^s)$ using Weil's theorem. Implementing the program based on the proposed algorithm, we find a efficient non-supersingular elliptic curve over the finite composite field $GF(2^5)^{31})$ of the order larger than $10^{40}$ with prime factor larger than $10^{40}$ using the elliptic curve $E(GF(2^5))$ of the order 36.

Adaptive Partial Shading Determinant Algorithm for Solar Array Systems

  • Wellawatta, Thusitha Randima;Choi, Sung-Jin
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1566-1574
    • /
    • 2019
  • Maximum power point tracking (MPPT) under the partial shading condition is a challenging research topic for photovoltaic systems. Shaded photo-voltaic module result in complex peak patterns on the power versus voltage curve which can misguide classical MPPT algorithms. Thus, various kinds of global MPPT algorithms have been studied. These have typically consisted of partial shading detection, global peak search and MPPT. The conventional partial shading detection algorithm aims to detect all of the occurrences of partial shading. This results in excessive execution of global peak searches and discontinuous operation of the MPPT. This in turn, reduces the achievable power for the PV module. Based on a theoretical investigation of power verse voltage curve patterns under various partial shading conditions, it is realized that not all the occurrences of partial shadings require a global peak search. Thus, an intelligent partial shading detection algorithm that provides exact identification of global peak search necessity is essential for the efficient utilization of solar energy resources. This paper presents a new partial shading determinant algorithm utilizing adaptive threshold levels. Conventional methods tend to be too sensitive to sharp shading patterns but insensitive to smooth patterns. However, the proposed algorithm always shows superb performance, regardless of the partial shading patterns.

PACVD of Plasma Polymerized Organic Thin Films and Comparison of their Electrochemical Properties

  • I.S. Bae;S.H. Cho;Kim, M.C.;Y.H. Roh;J.H. Boo
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 한국표면공학회 2003년도 춘계학술발표회 초록집
    • /
    • pp.53-53
    • /
    • 2003
  • Plasma polymerized organic thin films were deposited on Si(100) glass and metal substrates using thiophene and ethylcyclohexane precursors by PECVD method. In order to compare electrochemical properties of the as-grown thin films, the effects of the RF plasma power in the range of 30~100 W. AFM showed that the polymer films with smooth surface and sharp interface could be grown under various deposition conditions. Impedance analyzer was utilized for the determination of I-V curve for leakage current density and C-V for dielectric constants, respectively. To obtain C-V curve, we used a MIM structure of metal(Al)-insulator(plasma polymerized thin film)-metal(Pt) structure. Al as the electrode was evaporated on the thiophene films that grew on Pt coated silicon substrates, and the dielectric constants of the as-grown films were then calculated from C- V data measured at 1MHz. From the electrical property measurements such as I-V and C-V characteristics, the minimum dielectric constant and the best leakage current of thiophene thin films were obtained to be about 3.22 and $1{\;}{\times}10^{-11}{\;}A/cm^2$. However, in case of ethylcyclohexane thin films, the minimum dielectric constant and the best leakage current were obtained to be about 3.11 and $5{\;}{\times}10^{-12}{\;}A/cm^2$.

  • PDF

Study on the Soil Compaction (흙의 다짐에 관한 연구(I))

  • 강문묵
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • 제11권4호
    • /
    • pp.1783-1790
    • /
    • 1969
  • It is one of the most economical method of soil stabilization works to compact soil, which increases soil density artificially. Compaction effort is to lessen void of soils, and consequently its aim is to enlarge friction and cohesion force, and reduce permeability of soil. Factors in compaction effort are moisture content, grain size, grain size distribution, physical properties, compaction method and temperature of soils etc. The results obtained in this study on the effects that grain size, gradation and physical properties influence upon compaction effort for 20 samples under the constant compaction method, are summarized as follows: 1. The bigger the maximum dry density is, the smaller the optimum moisture content is, on the other hand, the smaller the maximum dry densityis, the bigger the optimum moisture content is, ingeneral. 2. The coarser the grain size is, the bigger the maximum dry density is, and the optimum moisture content becomes small, and dry density-moisture content curve has the sharp peak, generally. Also, the finer the grain size is the smaller the maximum dry density is, and the optimum moisture content shows the big value, and dry density-moisture content curve has the dull peak. 3. The maximum dry density shows the biggest value on the sample to be about 15% of particles finer than No. 200 sieve. The more the percent passing of No. 10 sieve increase, the smaller the maximum dry density is. Soils which have uniformity coefficient less than 5 in particles larger than 0.074mm hardly show dry density-moisture content curve. 4. There is a relation which is ramax=2.3948-0.0376 Wopt between the maximum dry density and the optimum moisture content, namely, the maximum dry density is increased in proportion to decrease of the optimum moisture content. 5. There are relations to be the straight lines which the maximum dry density decrease, on the other hand, the optimum moisture content increase in accordance with enlargement of Atterberg Limit(LL, PL, PL) in compacted soils.

  • PDF