• Title/Summary/Keyword: Shape of bone cutting

Search Result 9, Processing Time 0.023 seconds

Effect of Feedrate and Specimen Shape on Cutting Force and Surface Roughness of Ultrasonic Dental Surgical Instrument (치과용 초음파 수술기의 이송속도 및 시편형상이 절삭반력과 표면거칠기에 미치는 영향)

  • Sang Ho Kim;Seung Han Yang;Joong Ho Lee;Jong Kyun Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.109-117
    • /
    • 2023
  • In this study, the effect of the shape of the specimen and the feedrate of the dental ultrasonic surgical instrument on the cutting force and surface roughness of the specimen is analyzed. Experimental specimens were made of SAWBONES artificial bone materials in square and spherical specimens. In addition, the cutting feedrate of the surgical instrument was controlled through the developed moving system. The cutting force generated when cutting the specimen was measured through a force sensor. After the experiment, the cutting surface of the specimen was observed through a three-dimensional optical microscope and the surface roughness was measured. Through one-way ANOVA, the effect of each specimen shape and feed rate on surface roughness was analyzed. As a result of the experiment, the cutting force increased proportionally in the initial feed rate increase stage, but the increase in cutting force decreased as the feed rate continued to increase. Also, the cutting force showed a difference according to the shape of the specimen. The spherical specimen with a relatively small cutting surface area had less cutting force than the square specimen. However, as a result of one-way ANOVA, it was found that the specimen shape and feed rate did not affect the surface roughness. In future studies, it is expected to be used for comparative analysis of ultrasonic surgical instruments and correlation analysis between cutting factors.

Effect of cutting flute length and shape on insertion and removal torque of orthodontic mini-implants (교점용 미니 임플랜트의 cutting flute의 길이 및 형태에 따른 식립 및 제거 토크의 비교)

  • Yun, Soon-Dong;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.39 no.2
    • /
    • pp.95-104
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the effect of length and shape of cutting flute on mechanical properties of orthodontic mini-implants. Methods: Three types of mini-implants with different flute patterns (Type A with 2.6 mm long flute, Type B with 3.9 mm long and straight flute, Type C with 3.9 mm long and helical flute) were inserted into the biomechanical test blocks (Sawbones Inc., USA) with 2 mm and 4 mm cortical bone thicknesses to test insertion and removal torque. Results: In 4 mm cortical bone thickness, Type C mini-implants showed highest maximum insertion torque, then Type A and Type B in order. Type C also showed shortest total insertion time and highest maximum removal torque, but Type A and B didn't showed statistically significant difference in insertion time and removal torque. In 2 mm cortical bone thickness, there were no significant difference in total insertion time and maximum removal torque in three types of mini-implants, but maximum insertion torque of Type A was higher than two other Types of mini-implants. Conclusions: Consideration about length and shape of cutting flute of mini-implant is also required when the placement site has thick cortical bone.

3 Dimensional Computer Simulated Cutting Guide for the Mandibuloplasty : A Preliminary Case Report

  • Choi, Jong-Woo;Jeong, Woo Shik;Oh, Tae Suk
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.80-82
    • /
    • 2015
  • The mandibuloplasty for the facial aesthetic reason has been the one of the most popular procedures in aesthetic facial bone surgery in East Asia. Most East Asian women prefer smaller-looking and smooth-shaped facial contour. Prominent mandible angle which are common in Asia would be the main problem for smooth facial contour. In addition, recently, the mandibular body and broad chin shape also are known to be remodeled in order to get the ideal smooth facial shape. However, mandibuloplasty is not that easy to cut because many patients has inward mandibular angle and the visual field in operation is limited. The aim of this trial is to try to provide the prefabricated cutting guide for the symmetric and appropriate mandibuloplasty with the surgeons. Preoperative computed tomography(CT) data were processed for the patient and computer simulation model was produced. Then, mandibuloplasty was done on the computer simulation screen. Based on this data, customized cutting guide was made. This prefabricated cutting guide was used in real mandibuloplasty bilaterally. Premade cutting guide for the mandibuloplasty based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the patients in near future.

EFFECTS OF THE ER,CR:YSGG LASER ON BONE BED PREPARATION WITH VARIOUS LASER TIPS

  • Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Hong, Seong-Doo;Lee, Shin-Jae;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.3
    • /
    • pp.255-260
    • /
    • 2008
  • STATEMENT OF PROBLEM: Preparation of implant beds with lasers is considered a safe and reliable method, but the accuracy of this technique has not been examined. PURPOSE: The purpose of this study was to evaluate the accuracy and effectiveness of implant bed preparation using an Er,Cr:YSGG laser. MATERIAL AND METHODS: An Er,Cr:YSGG laser was applied to pig rib bone. The laser was employed at a 5.75 W power setting, 30 Hz/sec pulse repetition, and 70 ${\mu}s$ pulse duration with 50 % water and 60% air spray. According to laser tips the groups were divided as follows; Group 1: paralleled - shaped sapphire tip (0.6 mm${\Phi}$), Group 2: paralleled - shaped zirconia tip (0.6 mm${\Phi}$), Group 3: tapered sapphire tip (0.4 mm${\Phi}$). The Er,Cr:YSGG laser tip was separated by 1 mm from the bone and applied for 15 seconds in a non-contact mode. After the application, the bone was sectioned for specimens. Histologic measurements were determined by computerized morphometry. The length of the prepared bone surface was measured and the width of the entrance was measured. The results were analyzed with one-way ANOVA (P<0.05). RESULTS: The prepared length of group 3 was longer than that of group 2. The prepared bone width was larger than the width of the laser tip in every group. Additional bone removal was observed adjacent to the prepared area and displayed an irregular surface. CONCLUSION & DISCUSSION: Different cutting effects were observed according to the laser tip, emphasizing the importance of proper tip selection in the clinical setting. This preliminary study supported the existence of hydrokinetic effects.

The Utility of a Three-Dimensional Approach with T-Shaped Osteotomy in Osseous Genioplasty

  • Jegal, Jung Jae;Kang, Seok Joo;Kim, Jin Woo;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.433-439
    • /
    • 2013
  • Background Facial beauty depends on the form, proportion, and position of various units of the face. In terms of the frontal view and facial profile, the chin is the most prominent aesthetic element of the lower third of the face. Many methods have been implemented to obtain good proportions of the lower face. In this study, we applied the T-shaped genioplasty method to correcting chin deformities. Methods All of the procedures in 9 cases were performed under general anesthesia. For genioplasty, a horizontal cutting line and 1 or 2 vertical cutting lines were drawn 5 mm below the mental foramen. Osteotomed bone segments of the chin were used for horizontal widening using bone grafts or for horizontal shortening. Likewise, they were used as bone grafts for vertical lengthening or vertical shortening. The bone segments were approximated in the midline and held in place using miniplates. Results The postoperative appearance of the 9 cases showed that the lower third of the face had been naturally changed. At the same time, vertical lengthening or shortening, and horizontal widening or shortening could be implemented during the operation. Satisfactory results were obtained based on reviews of the patients' preoperative and postoperative photographs. The patients were also satisfied with the outcomes. Conclusions Using T-shaped genioplasty, we efficiently adjusted the shape and position of the chin to obtain good proportions of the lower face and change its contour to obtain an aesthetically appealing oval face in accordance with East Asians' aesthetic preferences.

Finite element analysis of cortical bone strain induced by self-drilling placement of orthodontic microimplant (Self-drilling 방식의 마이크로임플란트 식립에 의해 발생하는 피질골 스트레인의 유한요소해석)

  • Park, Jin-Seo;Yu, Won-Jae;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.203-212
    • /
    • 2009
  • Objective: The aim of this study was to evaluate the strain induced in the cortical bone surrounding an orthodontic microimplant during insertion in a self-drilling manner. Methods: A 3D finite element method was used to simulate the insertion of a microimplant (AbsoAnchor SH1312-7, Dentos Co., Daegu, Korea) into 1 mm thick cortical bone. The shape and dimension of thread groove in the center of the cortical bone produced by the cutting flute at the apical of the microimplant was obtained from animal test using rabbit tibias. A total of 3,600 analysis steps was used to calculate the 10 turns and 5 mm advancement of the microimplant. A series of remesh in the cortical bone was allowed to accommodate the change in the geometry accompanied by the implant insertion. Results: Bone strains of well higher than 4,000 microstrain, the reported upper limit for normal bone remodeling, were observed in the peri-implant bone along the whole length of the microimplant. Level of strains in the vicinity of either the screw tip or the valley part were similar. Conclusions: Bone strains from a microimplant insertion in a self-drilling manner might have a negative impact on the physiological remodeling of cortical bone.

Reconstruction with Deep Circumflex Iliac Artery Flap on Squamous Cell Carcinoma on the Floor of the Mouth: Case Report (구강저에 발생한 편평세포암에서 심장골회선동맥피판을 이용한 재건의 치험례)

  • Jang, Han-Seung;Kim, Su-Gwan;Moon, Seong-Yong;Oh, Ji-Su;Yun, Yeong-Eun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.33 no.6
    • /
    • pp.525-528
    • /
    • 2011
  • A deep circumflex iliac artery (DCIA) flap is usually used for reconstruction in oral and maxillo-facial surgery department since introduced by O'Brien in 1975. Various flap designs are possible for osteomusculocutaneous, musculocutaneous, musculosseous and vascularized bone types. Iliac crest shape is similar to contour of mandible. Moreover, though a fibular flap has only 15~20 mm of cutting plane width, a DCIA flap contains much more bone amount, making this a similar reconstruction compare with normal mandible. A 68 year-old male with squamous cell carcinoma on the anterior floor of the mouth had an impression with T2N0Mx and the treatment procedure was DCIA reconstruction after wide resection and marginal mandibulectomy, with both supraomohyoid neck dissection. We present an experience of DCIA flap for reconstruction with a literature review.

Considerations and Protocols in Virtual Surgical Planning of Reconstructive Surgery for More Accurate and Esthetic Neomandible with Deep Circumflex Iliac Artery Free Flap

  • Kim, Nam-Kyoo;Kim, Hyun Young;Kim, Hyung Jun;Cha, In-Ho;Nam, Woong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.36 no.4
    • /
    • pp.161-167
    • /
    • 2014
  • Purpose: The reconstruction of mandibular defects poses many difficulties due to the unique, complex shape of the mandible and the temporomandibular joints. With development of microvascular anastomosis, free tissue transplantation techniques, such as deep circumflex iliac artery (DCIA) flap and fibular free flap (FFF), were developed. The DCIA offers good quality and quantity of bone tissue for mandibular segmental defect and implant for dental rehabilitation. Virtual surgical planning (VSP) and stereolithography-guided osteotomy are currently successfully applied in three-dimensional mandibular reconstruction, but most use FFF. There are only a few articles on reconstruction with the DCIA that assess the postoperative results. Methods: Three patients admitted during a five month period (April of 2013 to August of 2013) underwent resection of mandible and DCIA musculo-osseous reconstruction using a VSP and stereolithographic modeling and assessment of outcomes included technical accuracy, esthetic contour, and functional outcomes. Results: This technique yielded iliac bone segment with excellent apposition and duplication of the preoperative plan. Flap survival was 100 percent and all patients maintained preoperative occlusion and contour. Conclusion: Based on our experience, we offer considerations and logically consistent protocols by classification of mandibular defects, and demonstrate the benefits in VSP and stereolithographic modeling of mandibular reconstructive surgery with DCIA flap.

A Study on the Butchering place and method of Animal remains-centering around at the shell middens of proto-three kingdoms and three kingdoms (동물유체의 해체장소와 방법에 관한 일고찰-삼한 및 삼국시대의 조개더미 자료를 중심으로)

  • Yu, Byeong-Il
    • KOMUNHWA
    • /
    • no.70
    • /
    • pp.63-88
    • /
    • 2007
  • The purpose of this writing is to examine the places and instruments of the dissection for deformed animal carcasses excavated in shellfish stacks of the period of the Proto-Three Kingdoms(삼한) and the Three Kingdoms(삼국). The remains were chosen, which had been excavated and finished in the analysis of the animal carcasses, and the main objects are all shells and deer, especially among Mammalia. As the result, the dissection of shells was not taken place in the habitats of the animals, but inside or around of the residence of the people. For deer, too, it was done in the public place or specific area around and inside the residence. As concerns the method of dissection for shells, for Pelecypoda(부족류), represented by Meretrix lusoria(백합), the inner meat was taken out by wrenching the shell with a kind of small knives, or by boiling, and sometimes by cracking the middle of the shell in the case of big Meretrix lusoria and Dosinorbis japonicus(떡조개). For Rapana venosa(피뿔고둥), representative of Gastropoad(배발류), the people broke the top or some parts of the body to get the inner meat or used some kind of needles and stylus to pick the inner meat out after boiling. Abalones‘ meat was attached firmly to the shell, so very sharp and proper metal instruments were used to take the meat out Relatively small-sized Reishia clavigera(대수리),Top shell(밤고둥) meats were taken out by breaking the top parts after boiling, then sucking the meats, or by picking them out by using needles and stylus in the original shape. In the case of large Mammalia like deer, in the full consideration of the point that deer itself are used in various ways, they were dissected in the order of skinning, taking out the internal organs, cutting front and rear legs, separating joint parts and meats, extracting bone-marrow by 철정, 철부, ironed hand knife in very delicate ways. It seems that skinning, and front and rear legs' cutting were taken place in the place around the residence, on the other hand joint parts' separating and bone-marrow extracting in the residence. The tools for the dissection were confirmed to be hand-knife, honed ax, hammer stone, bondstone, needles and stylus, and some other sharp instrument. They were used properly according to objects.

  • PDF