• Title/Summary/Keyword: Shadow removal

Search Result 58, Processing Time 0.021 seconds

CALCIFYING ODONTOGENIC CYST ASSOCIATED WITH UNERUPTED TOOTH : REPORT OF A CASE (미맹출치를 동반한 Calcifying Odontogenic Cyst)

  • Ryu, Sun-Youl;Chung, Jung-Jae;Chung, Jong-Chull;Park, Jun-Ah;Choi, Hong-Ran
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.15 no.2
    • /
    • pp.105-112
    • /
    • 1993
  • A case of calcifying odontogenic cyst associated with an unerupted tooth which appeared in the left maxillary sinus of a 16-year-old woman, was reported. Clinical examination revealed painless swelling on the left maxillary posterior region and the cheek. Radiographically, this lesion showed a monolocular radiolucent shadow with calcified materials and unerupted maxillary second premolar. Histological examination revealed cystic structure with presence of the ghost cells, calcified tissue and unerupted tooth. This lesion was classified as Type IB of COC according to classification of the Praetorius. After surgical removal of the cyst, the wound healed uneventfully and the lesion is now free of symptoms.

  • PDF

A Case of Foreign Body Granuloma of the Posterior Mediastinum (후 종격동에 발생한 이물육아종 1예)

  • Choi, Eui-Hyuk;Yoo, Jong-Hoon;Lee, Jeong-Seok;Hong, Su-Hee;Gwon, Hyung-Joo;Park, Young-Woo;Lee, Moo-Yeol;Lee, Chul-Ho;Bang, Jung-Hyun;Im, Sung-Gyun;Hwang, Soon-Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.3
    • /
    • pp.609-613
    • /
    • 1998
  • A 21-year-old male was admitted for evaluation of a mass shadow on chest film. On chest computed tomography showed 5 cm sized homogeneous low density based on the second thoracic vertebral body in the posterior mediastinum. The patient had been performed thoracic sympathectomy 6 months before admission and oxidized cellulose was used for hemostasis at that operation. Surgical resection was performed and microscopic result was foreign body granuloma caused by oxidized cellulose. Oxidized cellulose is an absorbable sterile mesh and used to control capillary or venous bleeding. Although the manufacturer recommends its removal after hemostasis is achieved, in clinical practice it is usually left in situ to reabsorb spontaneously, usually with no untoward effect.

  • PDF

Real Time Abandoned and Removed Objects Detection System (실시간 방치 및 제거 객체 검출 시스템)

  • Jeong, Cheol-Jun;Ahn, Tae-Ki;Park, Jong-Hwa;Park, Goo-Man
    • Journal of Broadcast Engineering
    • /
    • v.16 no.3
    • /
    • pp.462-470
    • /
    • 2011
  • We proposed a realtime object tracking system that detects the abandoned or disappeared objects. Because these events are caused by human, we used the tracking based algorithm. After the background subtraction by Gaussian mixture model, the shadow removal is applied for accurate object detection. The static object is classified as either of abandoned objects or disappeared object. We assigned monitoring time to the static object to overcome a situation that it is being overlapped by other object. We obtained more accurate detection by using region growing method. We implemented our algorithm by DSP processor and obtained an excellent result throughout the experiment.

Evaluation on usefulness of three dimensional reconstructive computed tomography images after pedicle screws fixation (척추경 나사못 고정술 시행 후 3차원 재구성CT영상의 유용성 평가)

  • Kim, Hyeon-Ju;Jang, Hyun-Chul;Cho, Jae-Hwan
    • Journal of Digital Contents Society
    • /
    • v.11 no.4
    • /
    • pp.553-559
    • /
    • 2010
  • By applying the various reformation techniques by using a circle raw data of after computed tomography image in the patient enforcing the spine screw fixation, this research tried to look into the various information including the exact location of the position of the screw spike and accuracy of an operation. In a clinical, by applying the or multi planar reformatting(MPR), that is the re-composition technique used mainly, maximum intensity projection (MIP), and volume rendering technique(VRT) and transformation removal from a register modifying VRT, video data were compared and were analyzed by the quantitative method and qualitative method. It is judged as the transformation volume rendering technique of the re-composition technique which is most useful in minimizing the artifact shadow by the exact location of the position of a screw and metal among the analysis and evaluation result computed tomography image reformation technique of the reformation image after the spine screw fixation.

A Case of Ceftriaxone Associated Biliary Sludge (Ceftriaxone과 연관된 소아의 담도 오니(biliary sludge) 1례)

  • Yoon, Jae Kyun;Lee, Hyun Hee;Shin, Young Kyoo;Choung, Ji Tae;Tockgo, Young Chang
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.308-313
    • /
    • 1997
  • Ceftriaxone, an effective third generation cephalosporin with a wide range of antimicrobial activity, has become widely used by pediatricians for a variety of bacterial infections including meningitis. It has been associated with the development of sludge or stone in the gallbladder of some patients treated with this drug. Ceftriaxone associated biliary sludge has unusual acoustic characteristics and resembles gallstone. The sludge can cause symptoms such as cramping abdominal pain, and disappears after stopping ceftriaxone administration. Because of these seemingly confusing observations, it is important for the clinicians to recognize these findings that ceftriaxone treatment can cause. We report a case of ceftriaxone associated biliary sludge in Korean children. A 6-year-old girl who was treated for meningitis with ceftriaxone (100mg/kg/day) developed cramping upper abdominal pain from 5th hospital day. Physical examination, liver function tests and X-ray revealed no specific abnormal findings. But abdominal ultrasound revealed high amplitude echogenic sludge with prominent post-acoustic shadow in gallbladder and its diameter was 1.5cm. We stopped ceftriaxone administration and tried conservative care. Abdominal cramping pain subsided after 3 days of ceftriaxone removal. Second abdominal ultrasound confirmed the disappearance of sludge at 3 weeks later.

  • PDF

A Study on High performance Electrical Precipitation Technology for PM Removal in Exhaust Gas (배가스 내 미세먼지 제거를 위한 고성능 집진 기술에 대한 연구)

  • Kim, Soyeon;Kim, Minsung;Choi, Sangmi;Jung, Minkyu;Lee, Jinwook
    • Plant Journal
    • /
    • v.18 no.1
    • /
    • pp.50-54
    • /
    • 2022
  • The demand for high-efficiency dust collectors is rapidly increasing to remove PM from exhaust gas emission facilities, such as thermal power plants, steel mills, and industrial cogeneration plants, as the Pmemission standards have been strengthened. In this study, the electrospray is adapted for existing electrosratic precipitator(EP) to remedy its shortcomings and to improve the performance. Electrospray has been mainly used for the purpose of generating very fine droplets, but fir the purpose of EP, the flow rate over 10 mL/min per nozzleis required, and a high flow rate condition of 65 to 200 times is required. The electrospray of high flow rate has a completely different spray shape from the low flow rate condition, and was visualized through various figures such as corona discharge photographs and shadow images.

  • PDF

Abnormal Behavior Detection Based on Adaptive Background Generation for Intelligent Video Analysis (지능형 비디오 분석을 위한 적응적 배경 생성 기반의 이상행위 검출)

  • Lee, Seoung-Won;Kim, Tae-Kyung;Yoo, Jang-Hee;Paik, Joon-Ki
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.48 no.1
    • /
    • pp.111-121
    • /
    • 2011
  • Intelligent video analysis systems require techniques which can predict accidents and provide alarms to the monitoring personnel. In this paper, we present an abnormal behavior analysis technique based on adaptive background generation. More specifically, abnormal behaviors include fence climbing, abandoned objects, fainting persons, and loitering persons. The proposed video analysis system consists of (i) background generation and (ii) abnormal behavior analysis modules. For robust background generation, the proposed system updates static regions by detecting motion changes at each frame. In addition, noise and shadow removal steps are also were added to improve the accuracy of the object detection. The abnormal behavior analysis module extracts object information, such as centroid, silhouette, size, and trajectory. As the result of the behavior analysis function objects' behavior is configured and analyzed based on the a priori specified scenarios, such as fence climbing, abandoning objects, fainting, and loitering. In the experimental results, the proposed system was able to detect the moving object and analyze the abnormal behavior in complex environments.

A Statistical Study of the Foreign Bodies in the Air Passages (기도 이물의 임상통계적 고찰)

  • 신기철;이동명;김진영;김홍기
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.4.1-4
    • /
    • 1981
  • The statistical study was done on 74 cases of foreign bodies in the air passages, who visited the department of otolaryngology of SNUH during recent 5 years from 1975 to 1980. The result was as follows, 1) Of the total 74 cases, 55 cases were male and 18 cases were female. The ratio between male and female was 3 : 1. 41.8% of all-cases were under 2 years of age, 75.5% were under 3 years, and 83.6% were under 5 years. 2) Major symptoms on visit were dyspnea, cough, cyanosis. No significant symptoms was noted in 6.7%. Initial physical findings were coarse breathing sound, decreased breathing sound, and stridor. No abnormal physical findings were noted in 10.8%. 3) 48.6% of total cases visited hospital within 24 hours. There was one case who visited hospital over 2 years later. 4) Initial simple chest film showed atelectasis in 25.0%, emphysema in 32.8%, definite foreign body shadow in 17.2% and within normal limit in 17.2%. 5) 60.8% of total cases were vegetables, 15.5% were metals, 16.2% were fish bone, and 2.7 % were others. 6) Vegetables were most frequent foreign bodies in the cases under 5 years of age. 7) 40.5% of total cases were lodged in the right main bronchus, 31.0% were in the left main bronchus, 9.8% were in trachea and 6.7% were in multiple sites, 8) Foreign bodies were removed by ventilating bronchoscopy in 82.3%, by tracheostomy only in 2.7%, by tracheal suction in 2.7%, by spontaneous removal in 1.3%, by thorachotomy in 5.4% and 5.4% of total cases were expired.

  • PDF