• 제목/요약/키워드: Setting error

검색결과 406건 처리시간 0.023초

An Analysis of the Relationship between Elevator Emergency(Entrapment) and Situation Measurement of Sag/Interruptions at the Switchboard

  • Kim, Gi-Hyun;Lim, Young-Bae;Bai, Seok-Myung;Kim, Jae-Chul;Lee, Hee-Tae
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.36-44
    • /
    • 2007
  • This study researched the mutual relationship between elevator emergencies(sudden stops, entrapment) and power quality such as voltage interruptions or sags. To analyze the power quality at the elevator switchboard of an apartment, the on-line power quality(sag, swell, and interruption, etc.) were measured and error messages(under voltage error, etc.) in the elevator control room were researched. Also the performance and susceptibility for stops were evaluated and stated through the testing of three pieces of simulated test equipment with an EN12016(2004) standard setting and the magnitude and duration data of the measured sag or interruption. This paper will use these data in the analysis of the mutual relationship between power quality and elevator emergencies.

Two Machine Learning Models for Mobile Phone Battery Discharge Rate Prediction Based on Usage Patterns

  • Chantrapornchai, Chantana;Nusawat, Paingruthai
    • Journal of Information Processing Systems
    • /
    • 제12권3호
    • /
    • pp.436-454
    • /
    • 2016
  • This research presents the battery discharge rate models for the energy consumption of mobile phone batteries based on machine learning by taking into account three usage patterns of the phone: the standby state, video playing, and web browsing. We present the experimental design methodology for collecting data, preprocessing, model construction, and parameter selections. The data is collected based on the HTC One X hardware platform. We considered various setting factors, such as Bluetooth, brightness, 3G, GPS, Wi-Fi, and Sync. The battery levels for each possible state vector were measured, and then we constructed the battery prediction model using different regression functions based on the collected data. The accuracy of the constructed models using the multi-layer perceptron (MLP) and the support vector machine (SVM) were compared using varying kernel functions. Various parameters for MLP and SVM were considered. The measurement of prediction efficiency was done by the mean absolute error (MAE) and the root mean squared error (RMSE). The experiments showed that the MLP with linear regression performs well overall, while the SVM with the polynomial kernel function based on the linear regression gives a low MAE and RMSE. As a result, we were able to demonstrate how to apply the derived model to predict the remaining battery charge.

보간법을 이용한 수치적분법의 평균 오차에 관한 연구 (On the Average Case Errors of Numerical Integration Rules using Interpolation)

  • 최성희;황석형;이정배;홍범일
    • 정보처리학회논문지A
    • /
    • 제11A권5호
    • /
    • pp.401-406
    • /
    • 2004
  • 이 논문에서는 정적분의 근사 값을 계산하는 여러 적분 문제 중에서 보간 법을 사용하는 수치적분법의 평균오차에 대해서 연구한다. 특히 가장 널리 쓰이고 있는 방법 중의 하나인 복합 Newton-Cotes 구적법의 평균오차에 대해서 연구한다. 주어진 구간을 등 간격으로 나누었을 때, 각 점에서의 함수 값을 information으로 사용할 경우, 복합 Newton-Cotes 구적법의 평균오차를 계산하였으며, 이 때 이 오차는 가장 최소임을 이 논문에서 증명한다.

멀티콥터의 효율적 멀티미디어 전송을 위한 이미지 복원 기법의 성능 (Performance of Image Reconstruction Techniques for Efficient Multimedia Transmission of Multi-Copter)

  • 황유민;이선의;이상운;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제9권4호
    • /
    • pp.104-110
    • /
    • 2014
  • 본 논문에서는 무인항공기인 방송용 멀티콥터를 이용한 Full-HD급 이상 화질의 이미지를 효율적으로 전송하기 위해 이미지 압축 센싱 기법을 적용하고, Sparse 신호의 효율적 복원을 위해 Turbo 알고리즘과 Markov chain Monte Carlo (MCMC) 알고리즘의 복원 성능을 모의실험을 통해 비교 분석하였다. 제안된 복원 기법은 압축 센싱에 기반하여 데이터 용량을 줄이고 빠르고 오류 없는 원신호 복원에 중점을 두었다. 다수의 이미지 파일로 모의실험을 진행한 결과 Loopy belief propagation(BP) 기반의 Turbo 복원 알고리즘이 Gibbs sampling기반 알고리즘을 수행하는 MCMC 알고리즘 보다 평균 복원 연산 시간, NMSE 값에서 우수하여 보다 효율적인 복원 방법으로 생각된다.

유성기어 소음을 고려한 pRMC 프로그램 개발 및 적용에 관한 연구 (Research for the Development of a pRMC Program for the Planetary Gear Noise)

  • 이현구;김무석;서현승;김진호;칼만아멧;하리안또자니;권현식
    • 한국소음진동공학회논문집
    • /
    • 제23권7호
    • /
    • pp.669-674
    • /
    • 2013
  • To design the optimized low noise planetary gear sets, a program called pRMC(planetary run many cases) is developed. The pRMC is especially using a combination analysis method for all gear specifications and also able to analyze any type of planetary gear sets. The pRMC is composed of the 5 sections those are generate, setting, evaluate, combine and analysis. After calculating all candidate gear sets, the pRMC could show many results that represent the character of each gear set including the transmission error which is the main gear noise factor, the contact ratios, the bending stress and so on. By comparing the results objectively, user could predict and select the optimized gear set which has quiet noise level and desired durability. The planetary gear designed by pRMC could have reduced noise and vibration level from 5 to 10 dB than previous-designed one.

지구자계를 이용한 3축 자계센서의 수직성분자계 보정방법 및 장치 (A Method and System to Compensate Vertical Component of 3-Dimensional Magnetic Field Sensor Using The Earth's Field)

  • 정영윤;임대영;유영재
    • 한국지능시스템학회논문지
    • /
    • 제16권3호
    • /
    • pp.297-302
    • /
    • 2006
  • 본 논문에서는 지구자계를 이용하여 3축 자계센서의 수직성분자계를 간편하게 보정할 수 있는 방법과 장치를 제안한다. 자계센서의 출력은 설치각도 및 이득오차에 의한 출력 오프셋을 포함하고 있다. 따라서 자계센서를 사용하기에 앞서 보정이 필요하다. 자계센서의 보정은 무자계 공간에서 이루어져야 하나 지구자계를 이용하면 간단하게 자계센서의 출력 오프셋을 보정할 수 있다. 그리고 보정을 위한 장치를 설계하였다. 제안하는 방법과 장치는 실험을 통하여 실용성을 검증하였다.

Filter orthogonal frequency-division multiplexing scheme based on polar code in underwater acoustic communication with non-Gaussian distribution noise

  • Ahmed, Mustafa Sami;Shah, Nor Shahida Mohd;Al-Aboosi, Yasin Yousif;Gismalla, Mohammed S.M.;Abdullah, Mohammad F.L.;Jawhar, Yasir Amer;Balfaqih, Mohammed
    • ETRI Journal
    • /
    • 제43권2호
    • /
    • pp.184-196
    • /
    • 2021
  • The research domain of underwater communication has garnered much interest among researchers exploring underwater activities. The underwater environment differs from the terrestrial setting. Some of the main challenges in underwater communication are limited bandwidth, low data rate, propagation delay, and high bit error rate (BER). As such, this study assessed the underwater acoustic (UWA) aspect and explored the expression of error performance based on t-distribution noise. Filter orthogonal frequency-division multiplexing refers to a new waveform candidate that has been adopted in UWA, along with turbo and polar codes. The empirical outcomes demonstrated that the noise did not adhere to Gaussian distribution, whereas the simulation results revealed that the filter applied in orthogonal frequency-division multiplexing could significantly suppress out-of-band emission. Additionally, the performance of the turbo code was superior to that of the polar code by 2 dB at BER 10-3.

잔류가스분석기의 질량 스펙트럼 검출 성능 향상을 위한 잡음제거 알고리즘 (Noise Reduction Algorithm For The Detection of Fine Ion Signals in Residual Gas Analyzer)

  • 허경용;최훈
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.102-107
    • /
    • 2019
  • This paper proposes a method to improve the mass spectral detection performance of the residual gas analyzer. By improving the mode estimation method for setting the threshold value and improving the additive noise elimination method, it is possible to detect mass spectrums having low peak values of the threshold level difficult to distinguish from noise. Ion signal blocks for each mass index with noise removed by the improved method are effective for eliminating invalid ion signals based on the linear and quadratic fittings. The mass spectrum can be obtained from the quadratic fitted curves for the reconstructed ion signal block using only the valid ion signals. In addition, the resolution of the mass spectrum can be improved by correcting the error caused by the shift of the spectral peak position. To verify the performance of the proposed method, computer simulations were performed using real ion signals obtained from the residual gas analysis system under development. The simulation results show that the proposed method is valid.

Development of a Camera Self-calibration Method for 10-parameter Mapping Function

  • Park, Sung-Min;Lee, Chang-je;Kong, Dae-Kyeong;Hwang, Kwang-il;Doh, Deog-Hee;Cho, Gyeong-Rae
    • 한국해양공학회지
    • /
    • 제35권3호
    • /
    • pp.183-190
    • /
    • 2021
  • Tomographic particle image velocimetry (PIV) is a widely used method that measures a three-dimensional (3D) flow field by reconstructing camera images into voxel images. In 3D measurements, the setting and calibration of the camera's mapping function significantly impact the obtained results. In this study, a camera self-calibration technique is applied to tomographic PIV to reduce the occurrence of errors arising from such functions. The measured 3D particles are superimposed on the image to create a disparity map. Camera self-calibration is performed by reflecting the error of the disparity map to the center value of the particles. Vortex ring synthetic images are generated and the developed algorithm is applied. The optimal result is obtained by applying self-calibration once when the center error is less than 1 pixel and by applying self-calibration 2-3 times when it was more than 1 pixel; the maximum recovery ratio is 96%. Further self-correlation did not improve the results. The algorithm is evaluated by performing an actual rotational flow experiment, and the optimal result was obtained when self-calibration was applied once, as shown in the virtual image result. Therefore, the developed algorithm is expected to be utilized for the performance improvement of 3D flow measurements.

A novel reference model for dental scanning system evaluation: analysis of five intraoral scanners

  • Karakas-Stupar, Irina;Zitzmann, Nicola Ursula;Joda, Tim
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.63-69
    • /
    • 2022
  • PURPOSE. The aim of this in vitro study was to investigate the accuracy (trueness and precision) of five intraoral scanners (IOS) using a novel reference model for standardized performance evaluation. MATERIALS AND METHODS. Five IOSs (Medit i500, Omnicam, Primescan, Trios 3, Trios 4) were used to digitize the reference model, which represented a simplified full-arch situation with four abutment teeth. Each IOS was used five times by an experienced operator, resulting in 25 STL (Standard Tessellation Language) files. STL data were imported into 3D software (Final Surface®) and examined for inter- and intra-group analyses. Deviations in the parameter matching error were calculated. ANOVA F-test and Kruskal-Wallis test were applied for inter-group comparisons (α = .05); and the coefficient of variation (CV) was calculated for intra-group comparisons (in % ± SD). RESULTS. Primescan (matching error value: 0.015), Trios 3 (0.016), and Trios 4 (0.018) revealed comparable results with significantly higher accuracy compared to Medit i500 (0.035) and Omnicam (0.028) (P < .001). For intra-group comparison, Trios 4 demonstrated the most homogenous results (CV 15.8%). CONCLUSION. The novel reference model investigated in this study can be used to assess the performance of dental scanning technologies in the daily routine setting and in research settings.