• 제목/요약/키워드: Setting error

검색결과 400건 처리시간 0.031초

실험실 시험 장착오차를 고려한 관성측정장치 오차 모델링 (Modelling of IMU Error with Setteing Misalignment in Laboratory Test)

  • 성상만;이달호;이장규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권4호
    • /
    • pp.428-433
    • /
    • 1999
  • The errors of IMU(Inertial Measurement Unit) can be divided into deterministic and random errors. Since the required accuracy of the IMU is very high, the errors must be compensated by using an accurate error mode. In this paper, we present a method to get a more accurate error model in a laboratory test. This was done by considering the setting misalignment in the laboratory test in the IMU error model. We considered here the IMU which consits of DTG(dynamically tuned gyroscope) and pendulum type accelerometer. First, it was shown that the estimation result from the model which does not contain the setting misalignment gives considerable estimation error at the validation test. Second, a new model considering the setting misalignment was derived. Finally, by validation test using the estimation results from new model the validity of it was proved.

  • PDF

오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰 (Examination with Transmission Line Distance Relay Setting Rule Considering Error)

  • 조성진;최면송;현승호;김종욱;이주왕;조범섭;유영식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

표면영상유속계(SIV)를 활용한 홍수유출량 산정 시 참조점 설정에 따른 오차율 분석 (Error Rate Analysis according to Setting of the Reference Point for Calculating the Flood Runoff that using Surface Image Velocimeter (SIV))

  • 김용석;양성기
    • 한국환경과학회지
    • /
    • 제25권6호
    • /
    • pp.799-815
    • /
    • 2016
  • In this study, according to the reference setting based on the runoff video of 9:00 where the highest water level of 3.94 m has been recorded during the runoff of Cheon-mi Stream in Jeju Island by the attack of Typhoon no. 16 Sanba on September $17^{th}$, 2012, the error rate of long-distance and short-distance velocimetry and real-distance change rate by input error have been calculated and the input range value of reference point by stream has been suggested. In the reference setting process, if a long-distance reference point input error occurs, the real-distance change rate of 0.35 m in the x-axis direction and 1.35 m in y-axis direction is incurred by the subtle input error of 2~11 pixels, and if a short-distance reference point input error occurs, the real-distance change rate of 0.02 m in the x-axis direction and 0.81 m in y-axis direction is incurred by the subtle input error of 1~11 pixels. According to the long-distance reference point setting variable, the velocity error rate showed the range of fluctuation of at least 14.36% to at most 76.06%, and when calculating flux, it showed a great range of fluctuation of at least 20.48% to at most 78.81%.

BUILD-UP 힘측정 시스템의 출력거동 (Output Behavior of Build-Up Force Measuring System)

  • 강대임;송후근;홍창선
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2194-2205
    • /
    • 1995
  • In order to reduce the systematic error of a build-up system, we have proposed a new test procedure in which all force transducers in a build-up system are rotated by 90.deg. with a base platen fixed on a force standard machine. The setting positions of force transducers on the output of a build-up system were investigated using an orthogonal array. The effects of the parallelism of a build-up system and of the bending moment sensitivity of a force transducer were considered. The experimental results show that the setting position of the base platen hardly affects the output of the build-up system, but the setting positions of force transducers affects it strongly. It reveals that the new test procedure reduces effectively the systematic error of a build-up system.

오차를 고려한 765kV 변압기 보호 계전 정정룰 고찰 (Investigation into Transformer Protective Relay Setting Rule Considering Error Ratio)

  • 배영준;이승재;최면송;강상희;김상태;최정이;정창현;유영식;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.229-231
    • /
    • 2002
  • The digital current differential relaying scheme is widely used for primary protection of 765(kV) power transformer. The current differential relay pickup the internal fault at the threshold which is set at 30% of rating current. Margin of 30% include current transformer error 5%, relay error 5%, on load tap changer error 7% and margin factor 140% obtained from the field experience. In this paper transformer protection relay and relay setting rule of high voltage power system are discussed. And we verify the correctness of relay setting rule with current differential relay using Matlab simulation.

  • PDF

The Study of Error Compensation for Repeatability Improvement of Precision Positioning System

  • Lee, Woogeun;Changsoo Han;Park, Hyeunseok;Lee, Kyeyoung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.66.6-66
    • /
    • 2001
  • In this paper, we studied the error compensation using an error budget method for repeatability improvement of the precision positioning system. The precision positioning system is developed for micro-pressing machine. We performed the force and displacement analysis about parts of the system. Proposed system determines the position and orientation of the materials manufactured by micro-pressing machine. It is consisted of x-y-z linear stages setting the position, and the gripper system setting the orientation. We executed kinematic and dynamic modeling of the whole precision positioning system. By generalizing the design variables, precision positioning system has the flexibility of material dimension. As we tried an error compensation using ...

  • PDF

765kV 송전계통 보호계전기의 오차분석을 통한 정정지침에 관한 연구 (A Study on the Protective Relay Setting Rules for 765kV Power System by Analysis of Errors)

  • 최면송;이승재;강상희;조성진;배영준;조범섭;유영식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권1호
    • /
    • pp.50-57
    • /
    • 2003
  • In this paper, the protective relay setting rules of Korean electric power system are studied by analysis of errors to be considered. An accurate operation of protective relays with accurate settings are important in power system reliability. The setting rules are used from the first establishment in 1982 and revision in 1990 Therefore, it needs revise and analysis of the setting rules because of environmental changes such as voltage raise or applied new technology of power system. Two major setting rules are studied. One is the rule for Zones of distance relay for transmission lines. The other is the one of differential current in a differential relay for power transformers. The range of errors in the setting rules accepted in the field experience is studied in simulation of case study. Also some guide lines for the range of errors in the setting rules are presented from the case study using Matlab simulation.

AN ERROR OF SIMPONS'S QUADRATURE IN THE AVERAGE CASE SETTING

  • Park, Sung-Hee;Hong, Bum-Il
    • 대한수학회지
    • /
    • 제33권2호
    • /
    • pp.235-247
    • /
    • 1996
  • Many numerical computations in science and engineering can only be solved approximately since the available infomation is partial. For instance, for problems defined ona space of functions, information about f is typically provided by few function values, $N(f) = [f(x_1), f(x_2), \ldots, f(x_n)]$. Knwing N(f), the solution is approximated by a numerical method. The error between the true and the approximate solutions can be reduced by acquiring more information. However, this increases the cost. Hence there is a trade-off between the error and the cost.

  • PDF

시뮬레이션 교육을 통한 일반 X선 검사의 오류 분석 (Error Analysis of General X-ray Examination by Using Simulation Training)

  • 성열훈
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.919-927
    • /
    • 2018
  • 본 연구에서는 일반 X선 검사를 대상으로 시뮬레이션 교육 모델을 제시하고 실습 시 발생하는 오류를 분석하고자 하였다. 2012년부터 2018년까지 총 183명 (남자 77명, 여자 106명)의 학생이 참가하였다. 시뮬레이션 X선 시스템은 컴퓨터방사선영상(computed radiography, CR) 시스템을 이용하였다. 환자 보호, X선 검사의 정확성, 영상의 안정성 등의 검사 프로세스에 발생하는 오류 빈도수를 분석하였다. 그 결과 환자 자세 설정 오류, X선 중심선의 정확성 오류, 영상검출판의 크기 및 위치 설정 오류, 그리드 사용의 오류, 마킹의 오류, X선 조사조건 설정 오류, 조사야 설정의 오류, X선 입사각도의 오류, X선 조사거리의 오류 순으로 분석되었다. 이러한 오류를 중심으로 개선된 방사선사 실습 교육이 필요할 것이며 그로 인하여 정밀한 검사와 고품질의 의료서비스를 제공하여 국민들의 보건의료에 조금이나마 기여할 수 있기를 기대한다.