• Title/Summary/Keyword: Set Packing

Search Result 107, Processing Time 0.029 seconds

The Relationship Between Airborne Trichloroetnylene Concentrations and Total Trichloro-compounds and Trichloroacetic Acid in Urine (근로자의 트리클로로에틸렌 폭로 농도와 요중 총삼염화물 및 삼염화초산 농도와의 관계)

  • Jeon, Hasub;KIm, Hyunwook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.7-16
    • /
    • 1994
  • This study was designed to establish the relationship between airborne trichloroethylene concentrations and total trichloro-compounds and trichloroacetic acid in urine samples of the trichloroethylene exposed workers, to examine if the biological screening value for trichloroacetic acid in urine set by the Ministry of Labor is appropriate, and to suggest a suitable biological screening value for total trichloro-compounds in urine. Seventy male workers from the cleaning, the packing, and the inspcetion areas were selected as the study group and eighty male office workers were chosen as the control group. The results were as follows: 1. The mean values of total trichloro-compounds and trichloroacetic acid in the exposed group ($48.1{\pm}1.5mg/{\ell}$, $19.7{\pm}1.9mg/{\ell}$) were significantly higher than those in the control group($4.3{\pm}1.5mg/{\ell}$, $1.8{\pm}1.2mg/{\ell}$). 2. The airborne tichloroethylene concentrations were significantly related with the concentrations of total trichloro-compounds in urine(r=0.8212) and the concentrations of trichloroacetic acid in urine(r=0.7216). 3. The average trichloroethylene concentrations in the manual cleaning plants and that in the automatic cleaning plants were 40.1 ppm and 7.7 ppm, respectively. The difference between two groups was statistically significant. 4. The geometric mean of 49.6 ppm trichloroethylene concentration was resulted in the $185.4mg/{\ell}$ total trichloro-compounds in urine, and the 50 ppm trichloroethylene concentration was expected to produce $170.4{\pm}28.5mg/{\ell}$ total trichloro-compounds in urine. 5. With the geometric mean of 49.6 ppm trichloroethylene concentration, the corresponding geometric mean concentration of trichloroacetic acid in urine was $74.7mg/{\ell}$. In conclusion, the level of personal exposure to trichloroethylene concentration was significantly correlated with the concentrations of total trichloro-compounds and trichloroacetic acid in urine. Current biological screening value of $75mg/{\ell}$ for trichloroacetic acid in urine set by the Ministry of Labor was thought to be appropriate, and a biological screening value for total trichloro-compounds in urine should be set in the range of $170.4{\pm}28.5mg/{\ell}$ as a reference value for trichoroethylene exposure.

  • PDF

Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice (비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석)

  • Lee, Ung-Soo;Kwon, Sang-Chul
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.79-84
    • /
    • 2014
  • This study has been performed for about 270 days at analyzing biologically hazardous factors in order to develop HACCP system for the non heat-frozen carrot juice. A process chart was prepared by manufacturing process of raw agricultural products of non heat-frozen carrot juice, which was contained water and packing material, storage, washing, cutting, extraction of the juice, internal packing, metal detection, external packing, storage and consignment (delivery). As a result of measuring Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, Enterohemorrhagic E. coli before and after washing raw carrot, Standard plate count was $4.7{\times}10^4CFU/g$ before washing but it was $1.2{\times}10^2CFU/g$ detected after washing. As a result of testing airborne bacteria (Standard plate count, Coliform group, Yeast and Fungal) depending on each workplace, number of microorganism of in packaging room, shower room and juice extraction room was detected to be 10 CFU/Plate, 60 CFU/Plate, 20 CFU/Plate, respectively. As a result of testing palm condition of workers, as number of Standard plate count, Coliform group and Staphylococcus aureus was represented to be high as $6{\times}10^4CFU/cm^2$, $0CFU/cm^2$ and $0CFU/cm^2$, respectively, an education and training for individual sanitation control was considered to be required. As a result of inspecting surface pollution level of manufacturing facility and devices, Coliform group was not detected in all the specimen but Standard plate count was most dominantly detected in scouring kier, scouring kier tray, cooling tank, grinding extractor, storage tank and packaging machine-nozzle as $8.00{\times}10CFU/cm^2$, $3.0{\times}10CFU/cm^2$, $4.3{\times}10^2CFU/cm^2$, $7.5{\times}10^2CFU/cm^2$, $6.0{\times}10CFU/cm^2$, $8.5{\times}10^2CFU/cm^2$ respectively. As a result of analyzing above hazardous factors, processing process of ultraviolet ray sterilizing where pathogenic bacteria may be prevented, reduced or removed is required to be controlled by CCP-B (Biological) and critical level (critical control point) was set at flow speed is 4L/min. Therefore, it is considered that thorough HACCP control plan including control criteria (point) of seasoning fluid processing process, countermeasures in case of its deviation, its verification method, education/training and record control would be required.

Optimal Design of the Safety Valve by Response Surface Method (반응표면법을 이용한 안전밸브의 최적화)

  • Lee, Sang-Woo;Shin, Dae-Young;Byun, Cheol-Woong
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.5
    • /
    • pp.551-556
    • /
    • 2007
  • High pressure storage of the agent gas in fire suppression system was composed of tank, main valve and safety valve, which prevents the fracture of the high pressure storage. The safety valve has circular thin plate as fracture plate that was destroyed over fracture pressure. When inner pressure of the storage is reached the fracture pressure, the safety valve discharges gas and degrades simultaneously the inner pressure of the storage. There are design variables such as flow path diameter, inner diameter of the plastic packing ring, thickness of plate and fillet radius. In this variables, thickness of plate is set to be a value of 0.2mm. The main effect of variables on the inner pressure, has been decided using factorial design and statistical analysis. Therefore, the relation of variables are expressed by regression equation. It is disclosed results that the difference of fracture pressures between the equation and experiment has $2{\sim}5%$. Finally, using response surface method, the optimal design of the safety valve could be decided with safety pressure of 25MPa, where the fracture occurs on circular thin plate.

A Development of the Strategies for the Agricultural Extension Service through the Farmers' Educational Needs Assessment (농업인의 교육요구를 고려한 농촌지도사업의 발전 방향)

  • Shinn, Yun-Ho;Kim, Dae-Hee
    • Journal of Agricultural Extension & Community Development
    • /
    • v.19 no.1
    • /
    • pp.1-28
    • /
    • 2012
  • The Extension Program accountability will continue to be an influential force to develop agriculture and rural area. As we incorporate new approaches into our service program and respond to new domains of knowledge, we must also consider how our assessment strategies may need to change in order to meet local and other external standards. The main purpose of the study was to be what the best way of Extension Service is set farmers' educational needs met and to be what kind of methodologies and role of Extension system should provide for their faced problem solving effectively. The major results of the study on Farmers' needs toward Korean Extension Services are summarized as follows. First, it is observed that, when the farmers' perceptions were analyzed, the most ranked by the farmers' needs was "having nice extension workers to get advice and solve their problems on the farm in all at once." Farmers had especially more positive attitudes in the categories of interest and careers in ag-technology. To do services level up, the headquarter of Rural Development of Administration must be work with local branches to effectively deliver their missions and educational objectives to target crops and farmers group. And farmers were strongly needed "a specialized service team will be organized" to work closely with operating services for ag-products processing, packing and marketing. The recommendations were made by: farmers' needs should be identified and announced by computer networking development to solve their problems faster. Also, provincial and county level service members should have a chance to working at research institute or related work places with their incentives, which system will be easer to meet farmers' needs and deal with their problems so that the systematic approaches should be managed and recorded their educational attendings, education contents and even their farming corporations. Finally, Agricultural Extension Service should be met to general ag-technology literacy and be balanced with knowledge of other industries and be competitive service with better values in non-agricultural sectors.

A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method (인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구)

  • Mok Young-Jin;Kim Young-Su
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.5
    • /
    • pp.133-142
    • /
    • 2005
  • The research concentrates on improving the in-hole seismic probe, which has been developed in past five years, to be used in stiffness measurements of tunnel-face materials. The size of probe was reduced to be fit in 45-mm diameter holes (or BX) drilled by a jumbo-drill, which is used to drill holes to install explosives for tunneling. Also trigger system was improved by using a down-speeding motor for operating convenience and air packing system was replaced with a set of plate-springs to eliminate supply of compressed air. These modifications are to adjust the probe for the unfavourable environment inside of tunnels and to test without any further drilling cost. The probe and testing procedure were successfully adopted with horizontal holes drilled by a jumbo-drill at a tunnel-face to evaluate the stiffness of rock mass. The measured shear wave velocities can be used to estimate deformation properties of rock mass for tunnel analyses.

Packaging Standardization for Biological Control Agents (천적 곤충 포장 표준화에 관한 연구)

  • Ham, Eun Hye;Nam, Yun Bok;Jun, Hye Jeong
    • Korean journal of applied entomology
    • /
    • v.60 no.2
    • /
    • pp.203-214
    • /
    • 2021
  • This study aimed at establishing a packaging standardization method that allows the maintenance of biological control agents product quality during delivery. First, based on the results of distribution status analysis of biological control agent products from four manufacturers, we confirmed that the mean temperature was maintained at 25.6℃ (minimum and maximum temperatures.: 18.1 and 30.7℃, respectively) inside the packaging box of each company for 36-48 h. To establish the optimal packaging method for each season, seven external temperature conditions were set ranging between 0℃ and 30℃ at intervals of 5℃. In addition, we evaluated internal temperature maintenance performance for each coolant pack handling method and determined 14 packaging combinations. A packaging combination that maintained a temperature of 3℃ - 9.9℃ at each external temperature conditions was considered efficient. This temperature range is close to a lower developmental threshold at which the biological control agents can survive with minimum energy for 12 h (direct delivery time), or 36-48 h (general delivery time) after packaging.

Bin Packing-Exchange Algorithm for 3-Partition Problem (3-분할 문제의 상자 채우기-교환 알고리즘)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.4
    • /
    • pp.95-102
    • /
    • 2022
  • This paper proposed a linear time algorithm for a three-partition problem(TPP) in which a polynomial time algorithm is not known as NP-complete. This paper proposes a backtracking method that improves the problems of not being able to obtain a solution of the MM method using the sum of max-min values and third numbers, which are known polynomial algorithms in the past. In addition, the problem of MM applying the backtracking method was improved. The proposed algorithm partition the descending ordered set S into three and assigned to the forward, backward, and best-fit allocation method with maximum margin, and found an optimal solution for 50.00%, which is 5 out of 10 data in initial allocation phase. The remaining five data also showed performance to find the optimal solution by exchanging numbers between surplus boxes and shortage boxes at least once and up to seven times. The proposed algorithm that performs simple allocation and exchange optimization with less O(k) linear time performance complexity than the three-partition m=n/3 data, and it was shown that there could be a polynomial time algorithm in which TPP is a P-problem, not NP-complete.

Status of Economics Analysis Using LCC in Turn-Key Project : Focus on Landscape Architecture (설계시공일괄발주(턴키) 설계에서 LCC를 활용한 경제성 분석 실태: 조경분야를 중심으로)

  • Yoon, Yong-Han;Kim, Jeong-Ho
    • Journal of Environmental Policy
    • /
    • v.10 no.4
    • /
    • pp.39-59
    • /
    • 2011
  • In this article, I would like to analyze the conditions in applying the LCC method for each construction type by selecting 10 apartment complexes among the Turn-key projects which have been ongoing for the last 5 years. In addition, this article will identify the problems to the application of double landscape architecture and suggest improvement measures. Among the 10 case targets, a total of 151 LCC analyses were conducted, and the average application ratio placing for each construction type was shown in the following order: architecture (34.4%)> electricity (21.2%)>machine (18.5%)>civil engineering (13.2%)>landscape architecture (12.6%). As numbers show, landscape architecture was the lowest. The ratio of LCC reduction amount was shown in the following order: machine (32.1%)> architecture (23.9%)>electricity (23.4%)>civil engineering (17.5%)>landscape architecture (3.1%). The field of landscape architecture had a reduction amount that was about 5 to 6 times lower than civil engineering which had a similar number of LCC analysis cases. The total LCC analysis items of landscape architecture was 19, including 15 double packing material, 1 building covering, 1 grass planting, 1 planting infrastructure, and 1 facility. The following measures were suggested to promote LCC analysis in landscape architecture: first, set an analysis item that considers the construction expense ratio of landscape architecture; second, legal regulation of landscape architecture and expansion of its application; third, prepare VE/LCC standards which are suitable for landscape architecture.

  • PDF

An Investigation on the Airborne Asbestos Concentrations using PCM and TEM in the Public Buildings in Seoul (PCM과 TEM을 이용한 서울지역 일부 공공 건축물의 실내공기 중 석면농도 조사)

  • Chung, Sook-Nye;Nam, Eun-Jung;Hwang, Soon-Yong;Oh, Seok-Ryul;Shin, Jin-Ho;Eom, Seok Won;Chae, Young-Zoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.3
    • /
    • pp.139-145
    • /
    • 2011
  • Objectives: This investigation is purposed to evaluate the airborne asbestos concentrations in the public buildings having asbestos containing materials(ACMs) in Seoul. Methods: The Seoul Metropolitan Government carried out an asbestos survey to the city-owned public buildings to identify the level of risk exposure, classified into low, moderate and high risk. To evaluate the airborne concentration of asbestos, 11 sampling sites in ten buildings based on the survey were selected. The air samples from the eleven sites were analyzed by Phase Contrast Microscopy(PCM) and Transmission Electron Microscopy (TEM), and compared the analytical results from the both. Results: 1. The airborne fiber concentrations by PCM were less than the detection limit($7f/mm^2$) in 9(82%) out of 11 sampling sites. The highest concentration was 0.0043 f/cc, but it was below the guideline value for indoor air quality(0.01 f/cc), proposed by the Ministry of Environment, Korea. 2. In two sampling sites, having moderate risk level, the chrysotile was identified and showed it's concentrations of 0.0102 s/cc and 0.0058 s/cc, less than $5{\mu}m$ lengths. 3. The ACMs identified in the two sampling sites were a packing material(65% of chrysotile) in mechanical area and a thermal system insulation(5% of chrysotile) in a boiler room. Having more possibility of asbestos emission in the mechanical area, it would be required to set up and carry out the asbestos management plan. Conclusions: Based on the result of this study, the airborne asbestos concentrations in the public buildings with ACMs were generally lower than the guideline value for indoor air quality. There are widespread concerns about the possible health risk resulting from the presence of airborne asbestos fibers in the public buildings. Most of the previous studies about airborne asbestos analysis in Korea were performed based on PCM method that asbestos and non-asbestos fibers are counted together. In the public and commercial buildings, having ACMs, it is suggested that the asbestos be analyzed by TEM method to identify asbestos due to concerns about asbestos exposure to workers and unspecified people.

Development of a Bioscrubber for Treatment of VOC Emissions from Contaminated Soil with Hydrocarbons (유류오염토양으로부터 발생하는 VOC가스처리를 위한 바이오스크러버 개발)

  • 장윤영;황경엽;곽재호;최대기
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.83-90
    • /
    • 1997
  • Aiming at the treatment of large volumes of gas with a low concentration of poorly water soluble VOC(Volatile Organic Compound), a new system is proposed: the combination absorption tower/bioreactor. In the scrubber part of the bioscrubbing system, the contaminating compounds are absorbed in a aqueous phase. The contaminated scrubbing liquid is transported to the bioreactor, where the compounds are biodegraded by aerobic microorganisms (mainly to carbon dioxide, water, and biomass). In this study, separation of a volatile organic compound(VOC) out of a waste gas stream has been carried out using a re-cyclable high boiling point extrant(HBE). The liquid stream containing a high boiling point entrant(HBE) scrubs the gas stream in a direct gas-liquid countercurrent contacting operation in a packed tower for the removal of said component from the gaseous stream. A packed-bed column using Pall Ring was set up in order to simulate practical conditions for the scrubbing tower. The liquid stream transported to the bioreactor is recovered and recycled to the scrubber. The model gas, which contained 400 mg/$\textrm{m}^3$ of toluene, at a rate of 100 L/min, flowed into the packed column where the scrubbing liquid trickled over the packing in countercurrent to the rising gas at 10~15L/min. The bioscrubber designed for large volume air streams containing VOCs showed removal efficiency up to 80% in an optimum operating conditions during the tests fer removing toluene from an air stream by scrubbing the air stream with HBE.

  • PDF