• 제목/요약/키워드: Set Packing

검색결과 107건 처리시간 0.034초

근로자의 트리클로로에틸렌 폭로 농도와 요중 총삼염화물 및 삼염화초산 농도와의 관계 (The Relationship Between Airborne Trichloroetnylene Concentrations and Total Trichloro-compounds and Trichloroacetic Acid in Urine)

  • 전하섭;김현옥
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.7-16
    • /
    • 1994
  • This study was designed to establish the relationship between airborne trichloroethylene concentrations and total trichloro-compounds and trichloroacetic acid in urine samples of the trichloroethylene exposed workers, to examine if the biological screening value for trichloroacetic acid in urine set by the Ministry of Labor is appropriate, and to suggest a suitable biological screening value for total trichloro-compounds in urine. Seventy male workers from the cleaning, the packing, and the inspcetion areas were selected as the study group and eighty male office workers were chosen as the control group. The results were as follows: 1. The mean values of total trichloro-compounds and trichloroacetic acid in the exposed group ($48.1{\pm}1.5mg/{\ell}$, $19.7{\pm}1.9mg/{\ell}$) were significantly higher than those in the control group($4.3{\pm}1.5mg/{\ell}$, $1.8{\pm}1.2mg/{\ell}$). 2. The airborne tichloroethylene concentrations were significantly related with the concentrations of total trichloro-compounds in urine(r=0.8212) and the concentrations of trichloroacetic acid in urine(r=0.7216). 3. The average trichloroethylene concentrations in the manual cleaning plants and that in the automatic cleaning plants were 40.1 ppm and 7.7 ppm, respectively. The difference between two groups was statistically significant. 4. The geometric mean of 49.6 ppm trichloroethylene concentration was resulted in the $185.4mg/{\ell}$ total trichloro-compounds in urine, and the 50 ppm trichloroethylene concentration was expected to produce $170.4{\pm}28.5mg/{\ell}$ total trichloro-compounds in urine. 5. With the geometric mean of 49.6 ppm trichloroethylene concentration, the corresponding geometric mean concentration of trichloroacetic acid in urine was $74.7mg/{\ell}$. In conclusion, the level of personal exposure to trichloroethylene concentration was significantly correlated with the concentrations of total trichloro-compounds and trichloroacetic acid in urine. Current biological screening value of $75mg/{\ell}$ for trichloroacetic acid in urine set by the Ministry of Labor was thought to be appropriate, and a biological screening value for total trichloro-compounds in urine should be set in the range of $170.4{\pm}28.5mg/{\ell}$ as a reference value for trichoroethylene exposure.

  • PDF

비가열냉동 당근주스의 HACCP 시스템 적용을 위한 미생물학적 위해 분석 (Microbiological Hazard Analysis for HACCP System Application to Non Heat-Frozen Carrot Juice)

  • 이웅수;권상철
    • 한국식품위생안전성학회지
    • /
    • 제29권2호
    • /
    • pp.79-84
    • /
    • 2014
  • 본 연구는 비가열 섭취 냉동 당근주스의 HACCP (Hazard Analysis Critical Control Point)시스템 구축을 위하여 생물학적 위해요소분석을 위한 목적으로 2013년 6월 21일~2014년 3월 30일까지 약 270일간 제주도 제주시 구좌읍 소재에 있는 구좌농협에서 수행하였다. 일반적인 과채주스 제조업체의 제조공정을 참고로 하여 공정도를 작성하였으며, 원료 농산물(당근), 용수와 포장재료 입고, 보관, 세척, 분쇄, 착즙, 냉각, 내포장, 금속검출, 외포장, 보관 및 출하공정에 대하여 Fig. 1과 같이 작성하였다. 원료 당근의 세척 전, 세척 후의 Coliform group, Staphylococcus aureus, Salmonella spp., Bacillus cereus, Listeria Monocytogenes, 장출혈성대장균수를 측정한 결과 Bacillus cereus 는 세척 전 $4.70{\times}10^4CFU/g$이었으나, 세척 후 $1.02{\times}10^2CFU/g$ 검출되었으며, 나머지 병원성균은 검출되지 않았다. 자외선살균공정에서 당근주스의 유속를 변화시키면서 미생물의 변화를 시험한 결과 유속 4 L/min을 한계기준으로 결정하였다. 작업장별 공중낙하균(일반세균수, 대장균, 진균수) 시험결과 세척실의 미생물수는 20 CFU/Plate가 검출되었다. 작업자 손 세척 전후 시험결과 세척 전 일반세균수가 $6{\times}10^4CFU/cm^2$로 높게 나타났으나 손 세척 후에는 검출되지 않아 손 세척 및 소독에 대한 중요성을 교육하고 훈련해야 할 것이다. 제조설비 및 기구의 표면오염도를 검사한 결과 모든 시료에서 대장균군은 검출되지 않았고, 일반세균은 포장기 노즐에서 가장 많은 $8.5{\times}10^4CFU/cm^2$ 검출되었다. 위해분석 결과 병원성미생물을 예방, 감소 또는 제거할 수 있는 자외선살균 공정이 CCP-B (Biological)로 관리되어야 하고, 한계기준은 유속 4 L/min로 결정하였다. 따라서 Kwon의 유산균을 함유한 녹즙의 HACCP에 관한 연구에서와 같이 자외선살균 공정의 한계기준 및 이탈시 조치방법, 검증방법, 교육 훈련과 기록관리 등 철저한 HACCP 관리계획이 필요할 것으로 생각된다.

반응표면법을 이용한 안전밸브의 최적화 (Optimal Design of the Safety Valve by Response Surface Method)

  • 이상우;신대영;변철웅
    • 한국전산구조공학회논문집
    • /
    • 제20권5호
    • /
    • pp.551-556
    • /
    • 2007
  • 소화시스템에 사용되는 고압의 소화가스 저장용기에는 저장용기의 파손을 막아주는 안전밸브가 있다. 이러한 안전밸브의 내부에는 원형 박판의 파열 판이 들어 있는데, 저장용기의 내압이 위험수준에 도달하면 파열 판이 파손하여 내압을 배출하는 역할을 한다. 안전밸브의 설계인자는 파열 판의 두께, 안전밸브의 유로 직경, 플라스틱 패킹 링의 내부 직경 그리고 파열 판을 고정하는 볼트 안쪽의 필렛 반경이 있다. 이중에서 파열 판의 두께는 0.2mm로 고정을 하였다. 요인배치법을 사용하여 주효과를 결정하였고 회귀방정식을 유도하였다. 이러한 회귀방정식은 추후 안전밸브의 설계에 있어서 기초 설계 자료로서 활용할 수 있도록 실험 결과와 비교하여 검증하였다. 검증실험 및 회귀방정식에 의한 결과의 오차는 약 $2{\sim}5%$ 정도인 것을 확인하였다. 그리고 반응표면법을 사용하여 기밀테스트 압력인 25MPa에서 파열할 수 있는 안전밸브의 최적 모델을 결정하였다.

농업인의 교육요구를 고려한 농촌지도사업의 발전 방향 (A Development of the Strategies for the Agricultural Extension Service through the Farmers' Educational Needs Assessment)

  • 신윤호;김대희
    • 농촌지도와개발
    • /
    • 제19권1호
    • /
    • pp.1-28
    • /
    • 2012
  • The Extension Program accountability will continue to be an influential force to develop agriculture and rural area. As we incorporate new approaches into our service program and respond to new domains of knowledge, we must also consider how our assessment strategies may need to change in order to meet local and other external standards. The main purpose of the study was to be what the best way of Extension Service is set farmers' educational needs met and to be what kind of methodologies and role of Extension system should provide for their faced problem solving effectively. The major results of the study on Farmers' needs toward Korean Extension Services are summarized as follows. First, it is observed that, when the farmers' perceptions were analyzed, the most ranked by the farmers' needs was "having nice extension workers to get advice and solve their problems on the farm in all at once." Farmers had especially more positive attitudes in the categories of interest and careers in ag-technology. To do services level up, the headquarter of Rural Development of Administration must be work with local branches to effectively deliver their missions and educational objectives to target crops and farmers group. And farmers were strongly needed "a specialized service team will be organized" to work closely with operating services for ag-products processing, packing and marketing. The recommendations were made by: farmers' needs should be identified and announced by computer networking development to solve their problems faster. Also, provincial and county level service members should have a chance to working at research institute or related work places with their incentives, which system will be easer to meet farmers' needs and deal with their problems so that the systematic approaches should be managed and recorded their educational attendings, education contents and even their farming corporations. Finally, Agricultural Extension Service should be met to general ag-technology literacy and be balanced with knowledge of other industries and be competitive service with better values in non-agricultural sectors.

인홀 시험을 이용한 터널 막장의 암반강성 측정에 대한 적용성 연구 (A Pilot Study of Stiffness Mesurements for Tunnel-Face Materials Using In-hole Seismic Method)

  • 목영진;김영수
    • 한국지반공학회논문집
    • /
    • 제21권5호
    • /
    • pp.133-142
    • /
    • 2005
  • 본 연구는 지난 5년간 개발해온 인홀 발진자를 터널 막장의 강성도 계측에 사용가능하도록 개선하는데 주력하였다. 프로브는 터널의 폭파를 위해 점보드릴로써 천공된 직경 45m의 홀에 맞추기 위하여 소형화되었다. 또한 트리거 시스템은 감속모터를 사용함으로서 편리하게 되었고, 에어 팩킹 시스템은 압축공기 없이 사용하기위한 플레이트 스프링으로 교체하였다. 이러한 개선은 프로브를 터널내부의 환경에 적합하게 만들고 추가되는 비용 없이 실험하기 위함이다. 프로브와 테스트 과정은 암반의 강성을 측정하기 위해 터널의 막장의 수평 홀에 성공적으로 적용되었다. 측정된 전단파 속도는 터널 해석을 위한 암반의 변형 특성을 측정하는 것에 사용될 수 있다.

천적 곤충 포장 표준화에 관한 연구 (Packaging Standardization for Biological Control Agents)

  • 함은혜;남윤복;전혜정
    • 한국응용곤충학회지
    • /
    • 제60권2호
    • /
    • pp.203-214
    • /
    • 2021
  • 본 연구는 천적 곤충을 운송하는 동안 제품의 품질을 유지할 수 있는 포장 표준화 방안을 마련하고자 수행되었다. 먼저 4개 업체의 천적 제품 유통 현황을 분석한 결과, 평균 배송 소요시간인 36 ~ 48시간동안 평균 25.6℃(최저온도: 18.1℃, 최고온도: 30.7℃)를 유지하는 것을 확인하였다. 계절별 최적의 포장방법을 구축하기 위하여 0 ~ 30℃ 범위에서 5℃ 간격으로 7개의 외부온도조건을 설정하였다. 또한 보냉제의 취급방법별 내부온도 유지성능평가를 실시해 14건의 포장조합을 도출하였다. 도출한 포장조합을 외부온도조건에 맞춰, 포장 후 12시간 이내의 직접 배송 또는 36 ~ 48시간이 소요되는 일반 배송기간 동안 최소한의 에너지로 천적의 생존을 유지할 수 있는 발육영점온도에 근접한 3.0 ~ 9.9℃로 유지할 수 있는 포장조합을 제시하였다.

3-분할 문제의 상자 채우기-교환 알고리즘 (Bin Packing-Exchange Algorithm for 3-Partition Problem)

  • 이상운
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권4호
    • /
    • pp.95-102
    • /
    • 2022
  • 본 논문은 NP-완전으로 다항시간 알고리즘이 알려져 있지 않은 3-분할 문제(TPP)에 대한 선형시간 알고리즘을 제안하였다. 본 논문은 기존에 알려진 다항시간 알고리즘인 최대-최소치와 제3의 숫자 합을 이용하는 MM법이 갖고 있는 해를 구하지 못하는 문제점을 개선한 역추적 법을 제안하였으며, 또한 역추적 법을 적용한 MM의 문제점도 개선하였다. 제안된 알고리즘은 내림차순 정렬된 S 집합을 3-분할하여 순방향, 역방향과 최대 여유량 순서인 최적합 배정 법으로 배정한 결과 10개 데이터 중 5개 데이터인 50.00%에 대해서는 최적 해를 찾을 수 있었다. 나머지 5개 데이터에 대해서도 최소 1회, 최대 7회의 잉여 상자와 부족 상자 간 숫자 교환으로 최적 해를 찾을 수 있는 성능을 보였다. 제안된 알고리즘은 n개 데이터를 3-분할한 m=n/3 보다도 적은 O(k)의 선형시간 수행 복잡도로 단순 배정과 교환 최적화를 수행하는 알고리즘으로 TPP가 NP-완전이 아닌 P-문제인 다항시간 알고리즘이 존재할 수 있음을 보였다.

설계시공일괄발주(턴키) 설계에서 LCC를 활용한 경제성 분석 실태: 조경분야를 중심으로 (Status of Economics Analysis Using LCC in Turn-Key Project : Focus on Landscape Architecture)

  • 윤용한;김정호
    • 환경정책연구
    • /
    • 제10권4호
    • /
    • pp.39-59
    • /
    • 2011
  • 최근 5년간 시행된 턴키사업 중 공동주택단지 10개소를 선정하여 공종별 LCC 기법 적용실태를 분석하고 이 중 조경분야의 적용 및 문제점을 파악하여 개선방안을 제시하고자 하였다. 연구대상지 10개소의 총 LCC 분석건수는 총 151건이었고, 공종별 평균 적용비율 순위는 건축(34.4%)>전기(21.2%)>기계(18.5%)>토목(13.2%)>조경(12.6%) 등의 순으로 조경분야가 가장 낮았다. LCC 절감액 비율은 기계(32.1%)>건축(23.9%)>전기(23.4%)>토목(17.5%)>조경(3.1%)의 순이었으며 조경분야는 LCC 분석건수가 비슷한 토목분야보다 약 5~6배 정도가 낮은 절감액을 보이고 있었다. 조경분야의 LCC 분석항목은 총 19건이었으며, 이 중 포장재 15건, 건물녹화 1건, 잔디식재 1건, 식재기반 1건, 시설물 1건 등이었다. 조경분야 LCC 분석의 활성화를 추진하기 위해서는 첫째, 조경분야 공사비 비율을 고려한 분석항목의 설정, 둘째, 조경분야의 법적 규정 및 확대 적용, 셋째, 조경분야에 적합한 VE/LCC 기준 마련 등이 필요하다.

  • PDF

PCM과 TEM을 이용한 서울지역 일부 공공 건축물의 실내공기 중 석면농도 조사 (An Investigation on the Airborne Asbestos Concentrations using PCM and TEM in the Public Buildings in Seoul)

  • 정숙녀;남은정;황순용;오석률;신진호;엄석원;채영주
    • 한국산업보건학회지
    • /
    • 제21권3호
    • /
    • pp.139-145
    • /
    • 2011
  • Objectives: This investigation is purposed to evaluate the airborne asbestos concentrations in the public buildings having asbestos containing materials(ACMs) in Seoul. Methods: The Seoul Metropolitan Government carried out an asbestos survey to the city-owned public buildings to identify the level of risk exposure, classified into low, moderate and high risk. To evaluate the airborne concentration of asbestos, 11 sampling sites in ten buildings based on the survey were selected. The air samples from the eleven sites were analyzed by Phase Contrast Microscopy(PCM) and Transmission Electron Microscopy (TEM), and compared the analytical results from the both. Results: 1. The airborne fiber concentrations by PCM were less than the detection limit($7f/mm^2$) in 9(82%) out of 11 sampling sites. The highest concentration was 0.0043 f/cc, but it was below the guideline value for indoor air quality(0.01 f/cc), proposed by the Ministry of Environment, Korea. 2. In two sampling sites, having moderate risk level, the chrysotile was identified and showed it's concentrations of 0.0102 s/cc and 0.0058 s/cc, less than $5{\mu}m$ lengths. 3. The ACMs identified in the two sampling sites were a packing material(65% of chrysotile) in mechanical area and a thermal system insulation(5% of chrysotile) in a boiler room. Having more possibility of asbestos emission in the mechanical area, it would be required to set up and carry out the asbestos management plan. Conclusions: Based on the result of this study, the airborne asbestos concentrations in the public buildings with ACMs were generally lower than the guideline value for indoor air quality. There are widespread concerns about the possible health risk resulting from the presence of airborne asbestos fibers in the public buildings. Most of the previous studies about airborne asbestos analysis in Korea were performed based on PCM method that asbestos and non-asbestos fibers are counted together. In the public and commercial buildings, having ACMs, it is suggested that the asbestos be analyzed by TEM method to identify asbestos due to concerns about asbestos exposure to workers and unspecified people.

유류오염토양으로부터 발생하는 VOC가스처리를 위한 바이오스크러버 개발 (Development of a Bioscrubber for Treatment of VOC Emissions from Contaminated Soil with Hydrocarbons)

  • 장윤영;황경엽;곽재호;최대기
    • 한국토양환경학회지
    • /
    • 제2권1호
    • /
    • pp.83-90
    • /
    • 1997
  • 저농도의 난 수용성 VOC가스가 포함되어 있는 다량의 오염가스를 처리하기 위하여 흡수탑과 생물반응기의 결합체인 새로운 처리시스템을 제시하였다. 바이오스크러버의 스크러버에서는 세정액으로 기상중의 처리대상오염물질의 흡수가 일어나며 세정액은 생물반응기로 이송되어 호기성 미생물이 오염물을 분해시킨다. 본 연구에서는 폐가스중의 VOC분리를 위하여 재순환가능한 고비점용매를 사용하였다. 고비점용매를 포함한 세정액은 기/액 향류접촉이 이루어지는 흡수탑의 충전층에서 폐가스중의 오염물을 분리한다. 흡수탑은 Pall ring충전제로 채워 실제공정을 모사 하고자 하였다. 흡수처리후 생물반응기로 이송된 흡수액은 재생 후 다시 흡수탑으로 재 순환하였다. 실험에 사용된 대상가스는 농도가 400 mg/$\textrm{m}^3$ 인 톨루엔으로, 세정액이 가스흐름과 향류로 약 10~15L/min의 유량으로 충전층을 적시며 내려오는 충전탑내부로 약 100 L/min의 유량으로 도입하였다. VOC처리를 위해 제작된 본 바이오스크러버에서 고비점용매를 이용한 연속실험결과 최적운전 조건에서 약 80%의 처리율을 얻을 수 있었다.

  • PDF