• Title/Summary/Keyword: Servo Filter

Search Result 60, Processing Time 0.026 seconds

The Design of an Improved PID Controller by Using the Kalman Filter (칼만 필터를 이용한 개선된 PID 제어기 설계)

  • Cha, In-Hyeok;Gwon, Tae-Jong;Han, Chang-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.7-15
    • /
    • 2000
  • This paper suggests an auto-tuning I'll) control algorithm that uses the advantage of PID controller and improves the system performance. The PID gains being designed by th- conventional method are tuned through the plant parameter estimation. The Extended Kalman Filter is used for the estimation. It works as an observer and noise filter. Moreover, as the plant state and the uncertain parameter could be estimated simultaneously, the proposed algorithm is very useful in the tracking control of a system with uncertain parameter. The auto-tuning I'll) controller could maintain the system performance in the case that the plant parameters are uncertain or varying. The proposed control algorithm requires a correct estimation of the plant parameter. The controller stability and the performance is considered through the stability criteria and a servo motor model. The Kalman filter estimates the most sensitive plant parameter, which is determined by the sensitivity analysis.

The Study of Servo-Parameter Tuning Technique for 6-Axes Articulated Robot Manipulator in Consideration of Dynamic Characteristics (동적 특성을 고려한 6축 로봇의 서보 파라미터 튜닝에 관한 연구)

  • Chung, W.J.;Kim, H.G.;Lee, C.M.;Hong, D.S.;Park, S.G.;Seo, Y.G.;Lee, G.S.
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.1-6
    • /
    • 2007
  • This paper presents a new experimental Servo-Parameter tuning technique for a 6-axes articulated robot manipulator, especially considering robot's dynamics. First of all, investigation for proportional gain of velocity control loop by using a Dynamic Signal Analyzer(DSA) is performed. Using the FUNCTION characteristic of DSA based on the Bode plot, the Bode plot of open loop transfer function can be obtained. In turn, the integral gain of a servo controller can be found out by using the integration time constant extracted from the Bode plot of open loop transfer function. In the meanwhile, the positional gain of the servo controller can be obtained by using the Bode plot of the closed loop transfer function. Using the experimental gain tuning technique proposed in this paper, the testing linear motion of DR6-II robot has been shown to be more accurate rather than the motion with a conventional(empirical) gain tuning technique in Doosan Mecatec Co., Ltd., by improving the dynamic response of the robot as well as synchronizing each joint velocity according to the positional command of an end-effector.

Application of LQR for Phase-Locked Loop Control Systems

  • Khumma, Somyos;Benjanarasuth, Taworn;Isarakorn, Don;Ngamwiwit, Jongkol;Wanchana, Somsak;Komine, Noriyuki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.520-523
    • /
    • 2004
  • A phase-locked loop control system designed by using the linear quadratic regulator approach is presented in this paper. The system thus designed is optimal system when system is in locked state and the parameter value of loop filter which is an active PI filter can be obtained easily. By considering the structure of loop filter of phase-locked loop is included in the process to be controlled, a type 1 servo system can be constructed when voltage control oscillator is considered as an integrator. The integral gain of the proposed system obtained by linear quadratic regulator approach can be used as an optimal value to design the parameter of loop filter. The implemented result in controlling the second-order lag pressure process by using the proposed scheme show that the system response is fast with no overshoot and no steady-state error. Furthermore, the experimental results are also shown in term of output disturbance effect rejection, tracking and process parameter changed.

  • PDF

A Study of the tracking of moving object of mobile robot using vision system (비젼시스템을 이용한 이동로봇의 이동물체 추적에 관한 연구)

  • Jeon, Jae-Hyun;Hong, Suk-Kyo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3083-3085
    • /
    • 1999
  • This paper presents an algorithm that the mobile robot track accurately a moving object with information from a CCD camera mounted on mobile robot. Singular Value Decomposition is adapted to remove the measurement noise of a Raw data of CCD. The mobile robot estimate the trajectory using Kalman filter and track the path of a moving object with a servo motor. Computer simulation results are showed that the efficient tracking system for the mobile robot is designed properly.

  • PDF

A Correction Method of the Error in the Survey of Topography Using an Ultrasound Altitude Sonar (초음파 고도계를 이용한 지형지물 측정에 있어서의 잡음에 의한 오차 보정 방법)

  • Kim, Sea-Moon;Choi, Jong-Su;Lee, Chong-Moo;Hong, Sup
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.10a
    • /
    • pp.26-31
    • /
    • 2001
  • In order to measure the distance from the bottom in the ocean we use ultrasound altitude sonars. The manganese nodule pick-up device developed by KRISO is also using an altitude sonar to control the gap between the pick-up head and sea bottom. This paper describes the performance of the altitude sonar by an experimental method. The experiment was performed with four ground models in a small basin, Manganese nodule models and water-bentonite mixture was used for setting up the ground models. Buttorworth filter was applied to remove the noise caused by a servo motor and its controller. The results show that the altitude sonar gives a good estimation of the types and slopes of the bottom as well as the distance.

  • PDF

A Study on the Improvement of Measurement Accuracy of Laser Interferometer using the Kalman filter (칼만 필터를 이용한 레이저 간섭계의 측정 정밀도 향상에 관한 연구)

  • Lee, Jea-Ho;Park, Tea-Dong;Jung, Joon-Hong;Park, Ki-Heon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.1783-1784
    • /
    • 2006
  • A laser interferometer is the unique measurement device that can measure the range up to a few meters with sub-nano resolution and this characteristic makes it as the important sensing device for the emerging nano-mechatronics technologies. The laser interferometer, however, is very sensitive to the environments such as temperature, humidity, sound noises, vibrations and air turbulences and these factors result in a few hundred nano meter errors. There have been many efforts to reduce these environmental errors. The output of the laser interferometer is assumed to be the sum of a real displacement and a Markov process noise. The purpose of this paper is to develop Kalman filter algorithms to reduce the laser interferometer measurement errors by exploiting the information of displacements in position-servo systems.

  • PDF

Analytical Design of Multiloop PI Controller for Disturbance Rejection in Multivariable Processes (다변수 공정에서의 외란제거를 위한 다중루프 PI 제어기의 해석적 설계)

  • Vu Truong Nguyen Luan;Lee Ji-Tae;Lee Moon-Yong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.5
    • /
    • pp.505-508
    • /
    • 2006
  • This paper presents a new analytical approach for designing multiloop PI controllers for disturbance rejection in multivariable processes with time delay. The proposed method is based on IMC-PID design approach. To overcome a sluggish load response by dominant pole in the process, the IMC filter is modified to compensate the dominant pole effect. Based on the modified IMC filter, an analytical tuning rule for multiloop PI controller is driven by extending the generalized IMC-PID method for single input/single output (SISO) systems [1] to multi input/multi output (MIMO) systems. Simulation results show that the proposed method gives a satisfactory load performance as well as servo performance in the multiloop system.

A Vibration Rejection of Linear Feeder System with PMSM using Adaptive Notch Filter (적응형 노치 필터에 의한 PMSM을 이용한 선형 피드 시스템의 진동 억제)

  • Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.274-283
    • /
    • 2006
  • The Permanent Magnet Synchronous Motor(PMSM) drive systems with ball-screw, gear and timing-belt are widely used in industrial applications such as NC machine, machine tools, robots and factory automation. These systems have torsional vibration in torque transmission from servo motor to mechanical load due to the mechanical couplings. This vibration makes it difficult to achieve quick responses of speed and may result in damage to the mechanical plant. This paper presents adaptive notch filter with auto searching function of vibration frequency to reject the mechanical vibration of linear feeder system with PMSM. The proposed adaptive notch filter can suppress the torque command signal of PMSM in the resonant bandwidth for reject the mechanical torsional vibration. However, the resonant frequency can vary with conditions of mechanical load system and coupling devices, adaptive notch filter can auto search the vibration frequency and suppress the vibration signal bandwidth. Computer simulation and experimental results shows the verification of the proposed adaptive notch filter in linear feeder system with PMSM.

6-Axes Articulated Robot Manipulator's Gain Tuning in consideration of dynamic specific (수직 다관절 로봇의 동적 특성을 고려한 Gain Tuning 연구)

  • Chung W.J.;Kim H.G.;Kim K.J.;Kim K.T.;Seo Y.G.;Lee K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.744-747
    • /
    • 2005
  • This research studied 6-Axes Articulated Robot Manipulator's gain Tuning in consideration of dynamic. First of all, search fur proportional gain of velocity control loop by dynamic signal analyzer. Proportional gain of velocity control loop is connected to dynamic signal analyzer. Next Select free Proportional Gain value. And Select amplitude X of sinusoidal properly so that enough Velocity Feedback Signal may be paid as there is no group to utensil department. Next step, We can get Bode Diagram of Closed loop transfer function response examination in interested frequency. Integral calculus for gain of velocity loop is depended on integral calculus correction's number. We can obtain open loop transfer function by integrator. And we can know bode diagram's special quality from calculated open loop transfer function. With this, Velocity Control Loop's Parameter as inner loop is controlled. Next In moving, when vibration occurs, it controls notch filter. And finally, we have to control fred-forward filter parameter for elevation of control performance.

  • PDF

Asymptotic Disturbance Rejection using a Disturbance Observer in the Track-Following Control System of a High-Speed Optical Disk Drive (고배속 광디스크 드라이브 트랙 추종 제어 시스템에서의 외란 관측기를 이용한 점근적 외란 제거)

  • 유정래;문정호;진경복;정명진
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.10 no.5
    • /
    • pp.402-410
    • /
    • 2004
  • To obtain a good tracking performance in an optical disk drive servo system, it is essential to attenuate periodic disturbances caused by eccentric rotation of the disk. As an effective control scheme for enhancing disturbance attenuation performance, disturbance observers (DOBs) have been successfully applied to the track-following servo system of optical disk drives. In disk drive systems, the improvement of data transfer rate has been achieved mainly by the increase of disk rotational speed, which leads to the increase of the disturbance frequency. Conventional DOBs are no longer effective in disk drive systems with a high-speed rotation mechanism because the performance of conventional DOBs is severely degraded as the disk rotational frequency increases. This paper proposes a new DOB structure for effective rejection of the disturbance in optical disk drives with a very high rotation speed. Asymptotic disturbance rejection is achieved by adopting a band-pass filter in the DOB structure, which is tuned based on the information on the disturbance frequency. In addition, performance sensitivity of the proposed DOB to changes in disk rotational frequency is analyzed. The effectiveness of the proposed DOB is verified through simulations and experiments using a DVD-ROM drive.