Reduction of Electromagnetic Field from Wireless Power Transfer Using a Series-Parallel Resonance Circuit Topology

  • Kim, Jong-Hoon;Kim, Hong-Seok;Kim, In-Myoung;Kim, Young-Il;Ahn, Seung-Young;Kim, Ji-Seong;Kim, Joung-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.3
    • /
    • pp.166-173
    • /
    • 2011
  • In this paper, we implemented and analyzed a wireless power transfer (WPT) system with a CSPR topology. CSPR refers to constant current source, series resonance circuit topology of a transmitting coil, parallel resonance circuit topology of a receiving coil, and pure resistive loading. The transmitting coil is coupled by a magnetic field to the receiving coil without wire. Although the electromotive force (emf) is small (about 4.5V), the voltage on load resistor is 148V, because a parallel resonance scheme was adopted for the receiving coil. The implemented WPT system is designed to be able to transfer up to 1 kW power and can operate a LED TV. Before the implementation, the EMF reduction mechanism based on the use of ferrite and a metal shield box was confirmed by an EM simulation and we found that the EMF can be suppressed dramatically by using this shield. The operating frequency of the implemented WPT system is 30.7kHz and the air gap between two coils is 150mm. The power transferred to the load resistor is 147W and the real power transfer efficiency is 66.4 %.

A Study on Current Harmonics Reduction and Unbalanced Source Voltage Compensation Using Series Active Power Filter and Parallel Passive Filter (직렬 능동전력필터와 병렬 수동필터를 이용한 고조파 전류 저감 및 불평형 전원 전압 보상에 관한 연구)

  • Oh, Jae-Hoon;Ko, Su-Hyun;Han, Yoon-Seok;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.10a
    • /
    • pp.196-199
    • /
    • 2001
  • This paper deals with current harmonics and unbalanced source voltages compensation using combined filter system. Filter system consists of a series active filter and parallel passive filters. Passive filters were a traditional method to compensate current harmonics, so those were installed in power system widely. The active filter can be a substitution to improve filtering characteristics and complement drawbacks of the passive filter. The combined system of the active power filter and passive filter can has a better compensation performances and economical goods. The series type active power filter injects compensation voltage into power system by transformers. It's compensation principle is able to applicate for voltage compensation. A new control algorithm for series active filter to compensate current harmonics and unbalanced source voltages is proposed. In the proposed algorithm, a compensation voltage for harmonic reduction is calculated directly by instantaneous reactive power theory, and a compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. By experiments, we show validity of proposed compensation method.

  • PDF

Electricity Generations in Submerged-flat and Stand-flat MFC Stacks according to Electrode Connection (침지 및 직립 평판형 MFC 스택에서 전극연결 방식에 따른 전기발생량 비교)

  • Yu, Jaecheul;Park, Younghyun;Lee, Taeho
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.589-593
    • /
    • 2016
  • Microbial fuel cell (MFC) can produce electricity from oxidation-reduction of organic and inorganic matters by electrochemically active bacteria as catalyst. Stacked MFCs have been investigated for overcoming low electricity generation of single MFC. In this study, two-typed stacked-MFCs (submerged-flat and stand-falt) were operated according to electrode connection for optimal stacked technology of MFC. In case of submerged-flat MFC with all separator electrode assembly (SEA) sharing anode chamber, MFC with mixed-connection showed more voltage loss than MFC with single-connection method. And MFC stacked in parallel showed better voltage production than MFC stacked in series. In case of stand-flat MFC, voltage loss was bigger when SEAs sharing anodic chamber only were connected in series. Voltage loss was decreased when SEAs parallel connected SEAs sharing anodic chamber were connected in series.

Fabrication Of Ultraviolet LED Light Source Module Of Current Limiting Diode Circuit By Using Flip Chip Micro Soldering (마이크로솔더링을 이용한 정전류다이오드 회로 자외선 LED 광원모듈 제작)

  • Park, Jong-Min;Yu, Soon Jae;Kawan, Anil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.237-240
    • /
    • 2016
  • The improvement of irradiation intensity and irradiation uniformity is essential for large area and high power UVA light source application. In this study, large number of chips bonded by micro soldering technique were driven by low current, and current limiting diodes were configured to supply constant current to parallel circuits consisting of large number of series strings. The dimension of light source module circuit board was $350{\times}90mm^2$ and 16,650 numbers of 385 nm flip chip LEDs were used with a configuration of 90 parallel and 185 series strings. The space between LEDs in parallel and series strings were maintained at 1.9 mm and 1.0 mm distance, respectively. The size of the flip chip was $750{\times}750{\mu}m^2$ were used with contact pads of $260{\times}669{\mu}m^2$ size, and SAC (96.5 Sn/3.0 Ag/0.5 Cu) solder was used for flip chip bonding. The fabricated light source module with 7.5 m A supply current showed temperature rise of $66^{\circ}C$, whereas irradiation was measured to be $300mW/cm^2$. Inaddition, 0.23% variation of the constant current in each series string was demonstrated.

Quench Characteristics of a Flux-lock type SFCL with Secondary Windings Connected in Serial and Parallel (2차 권선을 직.병렬연결한 자속구속형 전류제한기의 퀜치특성)

  • Park, Hyoung-Min;Cho, Yong-Sun;Choi, Hyo-Sang;Oh, Geum-Kon;Han, Tea-Hee;Lim, Sung-Hun;Hwang, Jong-Sun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.432-434
    • /
    • 2006
  • We investigated the quench characteristics of a flux-lock type superconducting fault current limiter (SFCL) according to the number of the superconducting elements at the subtractive polarity winding of a transformer. The flux-lock type SFCL consists of the transformer with a primary winding and two secondary windings connected in parallel, and the superconducting element was connected with secondary winding in series, respectively. The applied voltage at that tin was 200V. when two superconducting elements of the secondary winding was connected in parallel, the peak lie current increased up to 99A, while that flowing in a superconducting element in conventional flux-lock type SFCL showed 50A under the same conditions, the impedance of secondary winding under the same situation showed the opposite behavior. This enabled the parallel structure to be easy to increase the capacity of power system, in the meantime, The quench between two superconducting elements in the SFCL with two secondary windings connected in parallel was achieved simultaneously. While the quench-starting point was slightly different in the SFCL with two superconducting elements connected in series. We found that the parallel connection between the secondary windings increased the power capacity and let quench characteristics improve through their mutual linkage.

  • PDF

The Effect Analysis of Series and Shunt Compensation Schemes for EHV Long Transmission Lines (직병렬보상방법에 의한 초고압장거리송전선로의 보상효과분석)

  • Chung, J.K.;Kang, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.224-227
    • /
    • 1997
  • This study discuss two subjects : maximization of transmission capability and regulation of voltages along line within the permissible bounds. Series and parallel line compensation methods have been applied for those purposes using capacitors and reactors. In this paper, the effect of series and shunt line compensation for symmetrical line is analyzed. The results obtained in this paper can be applied 765kV class EHV transmission system.

  • PDF

A Study on the Sound Absorbing Performance of Parallel Perforated Plate Systems (병렬 다공판 시스템의 흡음성능에 관한 연구)

  • Hur, Sung-Chun;Lim, Jung-Bin;Ro, Sing-Nam;Lee, Dong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.902-907
    • /
    • 2002
  • An equivalent electroacoustic circuit approach of estimating the sound absorption coefficient for parallel perforated plate system is proposed. The proposed approach is validated by comparing the calculated absorption coefficients of a parallel single layer perforated plate system with the values measured by the two-microphone impedance tube method for various porosity and the number of perforated plate. The sound absorbing performances of parallel and series perforated plate systems are compared and discussed from a standpoint of frequency bandwidth with sound absorption. The proposed approach is further extended to the parallel double layer perforated plate system.

  • PDF

A Study on DC Changing Algorithm of the Line-Interactive UPS with Dual Converter Structure (2중 컨버터 구조를 갖는 계통 연계형 UPS의 DC 충전 알고리듬에 관한 연구)

  • Lee, Woo-Cheol;Yoo, Dong-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • This paper presents a three phase Line-Interactive uninterruptible power supply(UPS) system with dual converter structure. The three phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator, which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low total harmonic distortion(THD). This paper presents in the series and parallel active compensator charging method depending on the amplitude of the source voltage. The conventional Line-Interactive UPS system is responsible for the DC charging and output voltage regulation at the same time, but UPS system with dual converter structure, a series active compensator can also charge the DC link. Therefore the charging algorithm using the series and parallel compensator needs to be researched. Therefore, by making the DC link voltage stable it can contribute the stability of series and parallel compensator. The simulation and experimental result are depicted in this paper to show the effect of the proposed algorithm.