• Title/Summary/Keyword: Series stack

Search Result 72, Processing Time 0.02 seconds

Optimization of Operational and Constitutional Geometric Parameters for Thermoaoustic Energy Output

  • Oh, Seung Jin;Shin, Sang Woong;Chen, Kuan;Chun, Wongee
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.28-38
    • /
    • 2014
  • The effects of geometric parameters (stack position, stack length, resonator tube length) and varying input power over acoustic energy output were investigated. The acoustic laser kit (Garret 2000) was used for the construction of TA lasers. A series of sound pressure level measurements in different orientations did not differ significantly confirming that the sound wave generated could be assumed as a spherical wave. An increase in acoustic pressure was recorded with respective increase in input power, stack and resonator tube lengths owing to their relative influence over heat transfer rate and critical temperature gradient across the stack.

DECOMPOSITION SERIES AND SUPRATOPOLOGICAL SERIES OF NEIGHBORHOOD SPACES

  • Park, Sang-Ho
    • East Asian mathematical journal
    • /
    • v.23 no.1
    • /
    • pp.111-122
    • /
    • 2007
  • In this paper, we will show some relations between decomposition series {${\nu}^{\alpha}\;:\;{\alpha}$ is an ordinal } and supratopological series {${\sigma}_{\alpha}{\nu}\;:\;{\alpha}$ is an ordinal} for a neighborhood structure $\nu$ and the formular ${\sigma}_{\alpha}{\nu}\;=\;{\nu}^{({\omega}^{\alpha})}$, where $\omega$ is the first limit ordinal.

  • PDF

Optimal Design of 100W Class Single Phase Series Commutator Motor (100W급 단상직권 정류자 전동기의 최적설계)

  • Seo, Young-Taek;Lee, Woo-Suk;Gong, Jung-Sik;Oh, Chul-Soo;Bae, Sang-Han
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.720-722
    • /
    • 2000
  • Single phase series commutator motors is widely used in various home appliances, such as vacuum cleaner, electric mixers, electrical tools, etc. This paper deals with the characteristics of single phase series commutator motors of which parameters varied with stator turns and stack length to find optimal electric and magnetic loading. We try to measure these data through the experiments with several prototype motors. The experimental results show some specific stator turns and stack length with which this motor has the highest efficiency.

  • PDF

Experimental study on the interaction force between a permanent magnet and a superconducting roll stack

  • Wenxin Li;Tianhui Yang;Ying Xin
    • Progress in Superconductivity and Cryogenics
    • /
    • v.25 no.1
    • /
    • pp.11-15
    • /
    • 2023
  • In recent years, the interaction force between a permanent magnet and a closed superconductor coil has been gradually investigated in depth. The principle and application potential of an energy storage/convertor composed of a magnet and a closed superconducting coil have been proved. However, the study on the force between a magnet and a non-closed superconducting coil (superconducting roll stack) has hardly been reported in previous literature. The behavior of this kind of interaction and its influence to the interaction force between a permanent and a closed superconducting coil are also still unclear. In this paper, first we investigated the interaction force between a magnet and a superconducting roll stack. Then, a series of experiments were designed and conducted to clarify the factors affected the interaction force, including the geometrical parameters of the superconducting roll stack and the magnetic field density at the roll stack. Moreover, the comparison of the interaction forces between the magnet and roll stack or a closed coil was also introduced.

A Study on the Efficiency of Hydrogen-Oxygen Mixture Gas Generation Stack (수소-산소 혼합가스 발생 스택의 효율 연구)

  • Lee, Sang-Ho;Moon, Il-Sik;Kim, Chang-Hee;Kang, Kyoung-Soo;Park, Chu-Sik;Bae, Ki-Kwang
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.409-417
    • /
    • 2006
  • The characteristics of hydrogen-oxygen mixture gas generation stack was experimentally studied in terms of efficiency. For this purpose, the mixture gas generation stack was fabricated by connecting 7 cells in series following the Tero Ranta report. In order to avoid the instrument inaccuracy, all measuring equipments were re-tested and calibrated by Korea Laboratory Accreditation Scheme (KOLAS) certified laboratories. Since the amount of produced gas is most crucial in determining the efficiency, two gas collecting methods such as bottle trap method and wet gas meter method were adopted. From the experimental results, it was found that both KOH fume and steam evaporated along with hydrogen-oxygen mixture gas, and these by-product gases could cause the misestimation of the stack efficiency. The current, voltage, and energy efficiencies of the hydrogen-oxygen mixture gas generation stack was evaluated based upon the stack efficiency calculation method summarized in this work.

Operating Characteristics of Advanced 500W class Anode-supported Flat Tubular SOFC stack in KIER (500W 급 연료극 지지체 평관형 고체산화물연료전지 스택의 운전 특성)

  • Lim, Tak-Hyoung;Kim, Gwan-Yeong;Park, Jae-Layng;Song, Rak-Hyun;Lee, Seung-Bok;Shin, Dong-Ryul
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2007.11a
    • /
    • pp.193-198
    • /
    • 2007
  • KIER has been developing the anode supported flat tubular SOFC stack for the intermediate temperature $(700{\sim}800^{\circ}C)$ operation. for this purpose, we have first fabricated anode supported flat tubular cells by the optimization between the current collecting method and the induction brazing process. After that we designed the compact fuel & air manifold by adopting the simulation technique to uniformly supply fuel & air gas and the unique seal & insulation method to make the more compact stack. For making stack, the prepared anode-supported flat tubular cells with effective electrode area of $90cm^2$ of connected in series with 12 modules, in which one module consists of two cells connected in parallel. The performance of stack in 3 % humidified $H_2$ and air at $800^{\circ}C$ shows maximum power of 507 W. Through these experiments, we obtained basic & advanced technology of the anode-supported flat tubular cell and established the proprietary concept of the anode-supported flat tubular SOFC stack in KIER.

  • PDF

Series Stacking Techniques of Electrochemical Hydrogen Compressors (전기화학식 수소 압축기 직렬 스택 기술)

  • SANG HOON CHO;CHANG JONG KIM;MIN SOO KIM;DONG KYU KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.2
    • /
    • pp.168-174
    • /
    • 2024
  • The electrochemical hydrogen compressor was run under diverse operating conditions in order to probe its capabilities and limitations. It was found that, unlike single-cell operations, the electrochemical hydrogen compressor stack performance improved with a rise in temperature. This improvement in performance was attributed to the gradual weakening of the electro-osmotic drag over time, impacting membrane resistance. As a result of these experiments, compression levels, up to an impressive 120 bar, using the electrochemical hydrogen serial stack were achieved.

Fabrication and Performance Evaluation of Tubular Solid Oxide Fuel Cells Stack (원통형 고체산화물 연료전지 스택 제작 및 성능평가)

  • Kim, Wanje;Lee, Seungbok;Song, Rakhyun;Park, Seokjoo;Lim, Takhyoung;Lee, Jongwon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.467-471
    • /
    • 2013
  • In present work, optimized the manufacturing process of anode-supported tubular SOFCs cell and stack were studied. For this purpose, we first developed a high performance tubular SOFC cell, and then made electrical connection in series to get high voltage. The gas sealing was established by attaching single cells to alumina jig with ceramic bond. Through these process, we can obtain such high OVP as around 15V, which means that the electrical connection and gas sealing were optimized. Finally we developed a new tubular SOFC stack which shows a maximum power of 65W @ $800^{\circ}C$.

A Study on the Characteristics of Voltage Distribution of Stacked YBCO Coated Conductors in Series Connection

  • Chu, Sung-Yul;Hwang, Young-Jin;Kim, Young-Jae;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.4
    • /
    • pp.25-28
    • /
    • 2009
  • In order to apply superconducting electric machineries such as a Superconducting Fault Current Limiter (SFCL) to the power grid, the single module should be connected in series to have reasonable size. Superconducting tapes in the module also should be stacked to satisfy requirements such as large operation current of the power grid. This is because a single superconducting tape has restricted applicable current capacity. Moreover especially in SFCL at the fault, there should be equal voltage distribution in series-connected SFCL modules. In this paper, we investigated the voltage distribution in fault current of series-connected YBCO coated conductors (CC). Depending on characteristics of the CC samples such as critical current, even voltage distribution could be achieved or not. In addition, the effect of stacked CC on the change of voltage distribution comparing to non-stack cases in series connection was confirmed by experiments. As the CC stacked, voltage difference could be reduced.

Intrusion Detection System Utilizing Stack Ensemble and Adjacent Netflow (스텍앙상블과 인접 넷플로우를 활용한 침입 탐지 시스템)

  • Ji-Hyun Sung;Kwon-Yong Lee;Sang-Won Lee;Min-Jae Seok;Se-Rin Kim;Harksu Cho
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.6
    • /
    • pp.1033-1042
    • /
    • 2023
  • This paper proposes a network intrusion detection system that identifies abnormal flows within the network. The majority of datasets commonly used in research lack time-series information, making it challenging to improve detection rates for attacks with fewer instances due to a scarcity of sample data. However, there is insufficient research regarding detection approaches. In this study, we build upon previous research by using the Artificial neural network(ANN) model and a stack ensemble technique in our approach. To address the aforementioned issues, we incorporate temporal information by leveraging adjacent flows and enhance the learning of samples from sparse attacks, thereby improving both the overall detection rate and the detection rate for sparse attacks.