Effect of municipal sludge from drainage facility on foul smell (도시내 배수설비 슬러지가 악취에 미치는 영향 연구)

  • Yu, Dae-Hyun;Park, Jihoon;Lee, Yong-Hoon;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.3
    • /
    • pp.315-324
    • /
    • 2014
  • The residents' odor complaint is steadily increasing by odor causing from sewage system. A current drainage facilities and septic tank are included in the individual sewerage according to Sewerage Act. However, definitions and legal standards of drainage tank are insufficient. In addition, specifications and maintenance standards related to structure and size are not established. In this research, effect of drainage tank in individual sewage facilities on the odor occurrence was studied and the concentrations of $H_2S$ and composite odor were measured. From the measurements, the concentration of $H_2S$ and composite odor were 1 ppm ~ 5 ppm and 1.04 OU ~ 4.05 OU, respectively, before pump operation. Also, the concentration of $H_2S$ and composite odor were 5 ppm ~ 33 ppm and 5.10 OU ~ 35.04 OU, respectively, after pump operation. The concentration of SS in the effluent from drainage tank was ranged from 840 mg/L to 1,980 mg/L. These high concentration of SS seemed to be the major source of foul smell when high concentrated suspended solids in the public sewerage system were decomposed and then emitted. In this research, correlation coefficient ($R^2$) between $H_2S$ and composite odor before and after pumping were 0.925 and 0.918, respectively.

Characteristics for Co-digestion of Food Waste and Night Soil using BMP Test (BMP실험을 이용한 음식물폐기물 및 분뇨의 병합소화 특성)

  • Cho, Jinkyu;Kim, Hyungjin;Oh, Daemin
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.9
    • /
    • pp.13-18
    • /
    • 2014
  • BMP test was carried out to evaluate the characteristics for co-digestion of night soil and food waste. 6 types of sludge were tested in 30 days which were raw, excess, digested, night soil/septic tank (1:1), food waste (food : dilution water = 1:1), and mixed sludge. Bio gas was produced actively after 2 days, and continued in 2 weeks. Gas generation amount was decreased rapidly after considerable space of time. Especially maximum productivity of gas was shown in 7~8 days. The ultimate methane yields of raw, excess, digested, night soil/septic tank, food waste, and mixed sludge were 64.63, 67.49, 66.45, 72.44, 107.85, and 46.71 mL $CH_4/g$ VS respectively from Modified Gompertz model. The lag growth phase time and maximum specific methane production rate of mixed sludge were 1.88 day and 80.4 mL/day respectively. The methane potential of mixed sludge was higher than individual sludge. So high methane potential was expected by controlling mixing ratio of food waste. Besides stable operation of digestion tank and the solution of oligotrophic problem were possible.

Reuse of Treated Sewage Water from Absorbent Biofilter System as Agricultural Water Resources (농업수자원으로서의 흡수성 Biofilter 처리수 재이용)

  • 권순국;김현욱;권용웅;조영현;박상원;임경래
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.5
    • /
    • pp.151-159
    • /
    • 2003
  • Absorbent Biofilter Systems (ABS), composed of an anaerobic septic tank, a pump chamber and an absorbent biofilter tank, have been found to economically provide rural on-site wastewater treatment. This study was conducted to assess the potential of ABS effluent as an alternative water resource for agricultural and environmental use, with respect to the removal of pathogenic microorganism and their fertilization effect. A pilot scale ABS was used to compare its removal efficiency of pathogens from effluent water. Overall, more than 95 percent of Salmonella and E. coli were removed. This result demonstrates that a significant reduction in the pathogenic microorganism of effluents can occur in ABS, which implies the feasibility for the use of ABS effluent in agriculture and environment, with the provision of a further simple disinfection step, in order to satisfy the WHO guidelines for the microbiological quality in agriculture. In addition, because of the abundant nutritional content of ABS effluent, the substitution effect of fertilizer (N, P and K) in paddy irrigation, i.e. 2/3 for nitrogen, l/3 for phosphorus and 1/5 for potassium would be expected. Based on the experimental data, the ABS effluent could be used as a new alternative water resource for paddy irrigation, as well as for environmental purposes, such as supplying water to ecological parks in rural villages.

Design and Fabrication of Super Water-Saving Toilet System by Theory of Inventive Problem Solving (TRIZ) (창의적 문제해결 이론(TRIZ)를 활용한 초절수형 양변기 시스템의 설계 및 제작)

  • Lee, Kyeong-Won;Lee, Hong-Suk
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.376-379
    • /
    • 2001
  • This paper describes the design and fabrication process of super water-saving toilet bowl system by the theory of inventive problem solving (TRIZ). The physical contradiction in TRIZ is defined to obtain the conceptual design for saving water in toilet bowl system with preventing the bad smell from septic tank. The super water-saving toilet bowl system is obtained by using the separation principle in time for resolving the physical contradiction. The consumption of water in the prototype system fabricated, is estimated about $3{\ell}$ comparing with $13{\ell}$ of that in conventional toilet bowl system. The noise from water in the prototype toilet bowl system is decreased by 1/3 of that in conventional toilet bowl system.

  • PDF

Review of 5-year Experimental Data from Treatment Wetland (인공습지 실험시설의 5년간 결과 및 고찰(지역환경 \circled3))

  • 김민희;윤춘경
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.649-654
    • /
    • 2000
  • Field experiment was performed from August 1996 to June 2000. The pilot plant was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the treatment basin. The treatment basin was composed of sand and reed. Average removal rate of BOD, SS was about 75.9%, 73.4%, respectively. T-P removal rate was about 47.3%, and T-N removal rate was 19.6%. The reason for poor T-N removal might be due to high influent concentration and short retention times. As operation period increased, BOD removal rates were increased, and SS and T-P removal rates did not change significantly, but T-N removal rates were decreased.

  • PDF

Design of Super Water-Saving Toilet System by Solving Physical Contradiction in Theory of Inventive Problem Solving (TRIZ) (창의적 문제 해결 기법의 물리적 모순 해결에 의한, 초절수형 양변기 시스템의 설계)

  • 이홍석;이경원
    • Korean Journal of Computational Design and Engineering
    • /
    • v.6 no.3
    • /
    • pp.193-197
    • /
    • 2001
  • This paper describes the design process of super water-saving toilet bowl system by the theory of inventive problem solving (TRIZ). The physical contradiction in TRIZ is defined far saving water in toilet bowl system with preventing the bad smell from septic tank. The super water-saving toilet bowl system is obtained by using the separation principle in time far resolving the physical contradiction. The real system is made using CAD tools. The consumption of water in the system implemented, is estimated about 3 ιcomparing with 13 ι of that in conventional toilet bowl system.

  • PDF

A Study on the Small Wastewater Collection System for Rural Area (농촌지역 소규모 오수차집시스템에 관한 연구)

  • Yoon, Chun-Gyeong;Yoo, Chan
    • Journal of Korean Society of Rural Planning
    • /
    • v.4 no.2
    • /
    • pp.20-28
    • /
    • 1998
  • A small wastewater collection system for rural area was reviewed and the small diameter gravity (SDG) was thought to be the most appropriate. The pilot-scale field experiment was performed for 15 months and the result is presented. The wastewater used for experiment was the effluent of septic tank in Kon-Kuk University, and components are similar to normal domestic wastewater. The SDG experimental system included 2" PVC pipe and reverse-sloped lower section is included. No clogging problem by solids was experienced at the points where flow direction changed. The pipe-breaking by freezing was experienced during the cold weather, thus proper protection may be required where severe weather is expected.

  • PDF

Performance for a small on-site wastewater treatment system using the absorbent biofilter in rural areas (흡수성 Biofilter 를 이용한 농촌 소규모 오수처리 시설의 성능)

  • Kwun, Soon-Kuk;Yoon, Chun-Gyeong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.4
    • /
    • pp.310-315
    • /
    • 1999
  • The feasibility of an absorbent biofilter system was examined for rural wastewater treatment. Hydraulic loading rates varied from 50 to 250 cm/day. Effluent of the septic tank was fed into the absorbent biofilter, and small ventilation fan was provided to supply air at the rate of 250 L/min to aerate the biofilter. The biofilter system demonstrated high removal rates for $BOD_5$ and TSS at the loading rate of 150 cm/day, generally meeting the Korean effluent water quality standard of 20 mg/L applicable to both. The nutrient removal was less satisfactory than the results of $BOD_5$ and TSS, but it was within the expected range of biological treatment processes. Considering the abnormally high influent concentration of nutrients during the experiment, better performance results could have been obtained if ordinary domestic wastewater was used. The system performance was not significantly affected by the hydraulic loading up to 150 cm/day, which is far more than the loading limit of the sand filter systems. Maintenance requirement was minimal, and no problems with noise, odor, flies or sludge arose. Since the biofilter system can be operated at a distance, operation in remote rural area and multi-system connected to one control office might be advantageous to the rural area. Overall, considering the cost-effectiveness, stable performance, and minimum maintenance, the biofilter system was thought to be a competitive alternative to treat wastewater in Korean rural communities.

  • PDF

Effects of Hydraulic Rentention Time on Anaerobic Digestion of the Mixture of Nightsoil and Septic Tank Sludge (소화조(消化槽)의 수리학적(水理學的) 체류시간(滯留時間)이 분뇨(糞尿)와 정화조(淨化槽)슬러지 혼합물(混合物)의 혐기성소화(嫌氣性消化)에 미치는 영향(影響))

  • Lee, Kwang Ho;Yang, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.117-127
    • /
    • 1983
  • An experimental research was performed employing the two stage anaerobic digestion of the mixture of the nightsoil and septic tank sludge to determine the effects of various hydraulic retention time of the digestion on chemical characteristics and treatment effeciency, thus determining the proper retention time. Results of the research are as follows, 1. Volatile-acid decreased as HRT increased. 2. Alklinity and ammonia-N tended to increase as HRT increased as did pH values, however, were observed to be constant at higher HRT values than 15 days. 3. The removal efficiencies of TBOD, TCOD and VS increased as HRT increased. 4. The removal efficiency of volatile solid decreased as VS loading increased. 5. It was observed that the rates of gas production were: 0.33 with HRT of 5 days, 0.58 with HRT of 15 days and $0.57m^3/kg$ VS fed/day with HRT of 25 days respectively. It is believed that the highest rate of gas production was at HRT of 15 days. 6. The sludge settling experiment showed that the minimum settling time required to ensure the desired underflow concentraton was estimated to be 8.6 days.

  • PDF

Groundwater Contamination by Cation, Anion and Pesticides (지하수중 음이온, 양이온, 및 금속의 함량)

  • 김형석;정세영;최중명
    • Journal of environmental and Sanitary engineering
    • /
    • v.7 no.2
    • /
    • pp.111-128
    • /
    • 1992
  • According to the increase of population and industrialization, the quality of our drinking water are becoming worse by the contamination of resources, production of THM and other halogenated hydrocarbons during the purifying process, the problem of corroded water supplying pipeline, and the water reservoir tanks, Many people choose groundwater to drink instead of city tap water, but sometimes we get report about groundwater contamination by wastes, swage, septic tank, etc. It is reported that in U. S. over 20% of population are drinking groundwater, but U. S EPA reported the groundwater contamination by pesticides, herbicides, fungicides, fertilizer, and various chemical substances. Craun, et at announced the groundwater contamination by bacteria which are related with poor installation of septic tank. Johnson and Kross mentioned aboutmethemoglobinemia by NO3-N originated from human and animal feces, organic chemicals, and fertilizer, and as the results the infant mortality could be risen. Some scientist also reported the high concentration of metals in groundwaters and some cation and anions, and volatile organic compou nds. Authors investigated 80 groundwaters in urban, agricultural, and industrial area during last 3 month(June - August) to check any drinking water quality parameters are exceeding the standards. The results were as follow. 1, The average value of ammonia nitrate were within the standard, but 11.76% of urban area were exceeded the 10 rpm standard, in agricultural area 42.3175 were exceeded, and in industrial area 20.2% were exceeded the drinking water standard of 10 ppm. the highest concentration was 29.37 ppd in industrial area. 2. The mean value of metals is not exceeded the standard, but there were some groundwater whose Mn value was 0.424 ppm(standard is 0,3 ppm) in urban area, 0.737 rpm in agricultural area, and 5.188 ppm in industrial area. The highest Zn value was 1.221 ppm (standard is 1.0 ppm)was found in industrial area. 3. The percentage of contamination by general bacteria was 8.82% in urban area, 15.38% in agricultural area, and 15.00% in industrial area. Escherichia coil group was also contaminated by 35.29% in urban area, 30.76% in agricultural area, and 30.00% in industrial area. 4, The pH value was within the standard which means there was no influence by acid or alkali chemicals, nor acid rain Through the above results, all the groundwater should be tested to check the safety for drinking water and should make some alternative methods suitable for drink.

  • PDF