• Title/Summary/Keyword: Separation performance Standard

Search Result 114, Processing Time 0.024 seconds

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2006.11a
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF

Atmospheric Turbulence Simulator for Adaptive Optics Evaluation on an Optical Test Bench

  • Lee, Jun Ho;Shin, Sunmy;Park, Gyu Nam;Rhee, Hyug-Gyo;Yang, Ho-Soon
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.107-112
    • /
    • 2017
  • An adaptive optics system can be simulated or analyzed to predict its closed-loop performance. However, this type of prediction based on various assumptions can occasionally produce outcomes which are far from actual experience. Thus, every adaptive optics system is desired to be tested in a closed loop on an optical test bench before its application to a telescope. In the close-loop test bench, we need an atmospheric simulator that simulates atmospheric disturbances, mostly in phase, in terms of spatial and temporal behavior. We report the development of an atmospheric turbulence simulator consisting of two point sources, a commercially available deformable mirror with a $12{\times}12$ actuator array, and two random phase plates. The simulator generates an atmospherically distorted single or binary star with varying stellar magnitudes and angular separations. We conduct a simulation of a binary star by optically combining two point sources mounted on independent precision stages. The light intensity of each source (an LED with a pin hole) is adjustable to the corresponding stellar magnitude, while its angular separation is precisely adjusted by moving the corresponding stage. First, the atmospheric phase disturbance at a single instance, i.e., a phase screen, is generated via a computer simulation based on the thin-layer Kolmogorov atmospheric model and its temporal evolution is predicted based on the frozen flow hypothesis. The deformable mirror is then continuously best-fitted to the time-sequenced phase screens based on the least square method. Similarly, we also implement another simulation by rotating two random phase plates which were manufactured to have atmospheric-disturbance-like residual aberrations. This later method is limited in its ability to simulate atmospheric disturbances, but it is easy and inexpensive to implement. With these two methods, individually or in unison, we can simulate typical atmospheric disturbances observed at the Bohyun Observatory in South Korea, which corresponds to an area from 7 to 15 cm with regard to the Fried parameter at a telescope pupil plane of 500 nm.

Determination of Four Macrolide Antibiotics Residues in Chicken Muscle Using High-Performance Liquid Chromatography (액체크로마토그래피를 이용한 닭고기 시료에서의 마크로라이드계 동시분석법 개발)

  • Lee, Sang-Hee;Yoo, Miyoung;Shin, Dong-Bin
    • Journal of Food Hygiene and Safety
    • /
    • v.28 no.1
    • /
    • pp.19-23
    • /
    • 2013
  • A simple and rapid method has been developed and validated for simultaneous determination of each macrolides residues (spiramycin, josamycin, tilmicosin, tylosin) in chicken muscle by high-performance liquid chromatography- photo diode array (HPLC-PDA). Chicken muscle sample have been extracted with liquid-liquid extraction process; analytes was extracted by acetonitrile, and then defatted with hexane saturated by acetonitrile. The HPLC separation was performed on a Unison UK-$C_{18}$ ($150mm{\times}3.0mm$, $3{\mu}m$) with a gradient system of 0.1% trifloroacetic acid (TFA) and 0.1% trifloroacetic acid (TFA) in acetonitrile as the mobile phase. The drugs were detected at 232 nm for spiramycin and josamycin, and 287 nm for tilmicosin and tylosin. The limits of quantification (LOQs) were between 27 and $59{\mu}g/kg$; and the intra- and inter-day precision (relative standard deviation; RSD) was between 0.9-13.2 and 2.4-13.1%, respectively in chicken muscle sample. The method may has been successfully applied for multiresidue determination of four macrolides below the maximum residue limits (MRLs) established by the European Union (EU).

Optimization of HPLC Method and Clean-up Process for Simultaneous and Systematic Analysis of Synthetic Color Additives in Foods (식품 중 타르색소의 동시분석 및 계통분석을 위한 HPLC 분석조건 및 정제과정 확립)

  • Park, Sung-Kwan;Hong, Yeun;Jung, Yong-Hyun;Lee, Chang-Hee;Yoon, Hae-Jung;Kim, So-Hee;Lee, Jong-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.33-39
    • /
    • 2001
  • To develop a method for separation process using Sep-pak $C_18$, simultaneous and systematic analysis of 8 permitted and 11 non-permitted synthetic food colors in Korea, optimization of analysis conditions for reverse phase ion-pair high performance liquid chromatography was carried out. For the best result of Sep-pak $C_18$ separation the pH of color standard mixture solution was $5{\sim}6$ and 0.1% HCl-methanol solution were set as eluent. The colors eluated from Sep-pak $C_18$ cartridge were determined and confirmed by high performance liquid chromatography with a photodiode array detector at 420 nm for yellow colors type, at 520 nm for red colors type, at 600 nm for blue and green colors type and at 254 nm for mixed colors. Conditions for HPLC analysis were as follows: column, Symmetry $C_18$ (5 m, 3.9 mm $i.d.{\times}150\;mm$); mobile phase, 0.025 M ammonium acetate (containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (65 : 25 : 10) and 0.025 M ammonium acetate(containing 0.01 M tetrabutylammonium bromide) : acetonitrile : methanol (40 : 50 : 10); flow rate, 1 mL/min. It takes 35 minutes for simultaneaus analysis and 18 minutes for systematic analysis. The detection limits range of each colors were $0.01{\sim}0.05\;{\mu}g/g$.

  • PDF

Liquid Chromatography Quadrupole Time-Of-Flight Tandem Mass Spectrometry for Selective Determination of Usnic Acid and Application in Pharmacokinetic Study

  • Fang, Minfeng;Wang, Hui;Wu, Yang;Wang, Qilin;Zhao, Xinfeng;Zheng, Xiaohui;Wang, Shixiang;Zhao, Guifang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1684-1688
    • /
    • 2013
  • A rapid and sensitive method for determining usnic acid of Lethariella cladonioides in rat was established using high performance liquid chromatography (HPLC) quadrupole time-of-flight (QTOF) tandem mass (MS/MS). Rat plasma was pretreated by mixture of acetonitrile and chloroform to precipitate plasma proteins. Chromatographic separation was achieved on a column ($50{\times}2.1$ mm, $5{\mu}m$) with a mobile phase consisting of water (containing $5{\times}10^{-3}$ M ammonium formate, pH was adjusted to 3.0 with formic acid) and acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via collision induced dissociation (CID) under negative ionization mode. The MS/MS transitions monitored were m/z 343.0448 ${\rightarrow}$ m/z 313.2017 for usnic acid and m/z 153.1024 ${\rightarrow}$ m/z 136.2136 for protocatechuic acid (internal standard). The linear range was calculated to be 2.0-160.0 ng/mL with a detection limit of 3.0 pg/mL. The inter- and intra-day accuracy and precision were within ${\pm}7.0%$. Pharmacokinetic study showed that the apartment of usnic acid in vivo confirmed to be a two compartment open model. The method was fully valid and will probably be an alternative for pharmacokinetic study of usnic acid.

Simultaneous Determination of Five Porphyrins in Human Urine and Plasma Using High Performance Liquid Chromatography-Tandem Mass Spectrometry

  • Hur, Yeoun;Tae, Sookil;Koh, Yun-Joo;Hong, Sung-Hyun;Yoon, Young Ho;Jang, Haejong;Kim, Sooji;Kim, Kyeong Ho;Kang, Seung Woo;Lee, Youngshin;Han, Sang Beom
    • Mass Spectrometry Letters
    • /
    • v.5 no.2
    • /
    • pp.42-48
    • /
    • 2014
  • A specific and sensitive liquid chromatography-electrospray ionization tandem mass spectrometry method (LC-ESI-MS/MS) was developed and validated for the simultaneous quantification of porphyrins (coproporphyrin, pentacarboxylporphyrin, hexacarboxylporphyrin, heptacarboxylporphyrin, and uroporphyrin) in human plasma and urine. Acidified plasma samples and urine samples were prepared by using liquid-liquid extraction using ethyl acetate and protein precipitation with acetonitrile, respectively. The separation was achieved onto a Synergi Fusion RP column ($150mm{\times}2.0mm$, $4{\mu}m$) with a gradient elution of mobile phase A (0.1% formic acid in 2 mmol/L ammonium acetate, v/v) and mobile phase B (20% methanol in acetonitrile, v/v) at a flow rate of $450{\mu}L$/min. Porphyrins and the internal standard (IS), coproporphyrin I-$^{15}N_4$, were detected by a tandem mass spectrometer equipped with an electrospray ion source operating in positive ion mode. Multiple reaction monitoring (MRM) transitions of the protonated precursor ions and the related product ions were optimized to increase selectivity and sensitivity. The proposed method was validated by assessing selectivity, linearity, limit of quantification (LOQ), precision, accuracy, recovery, and stability. The calibration curves were obtained in the range of 0.1-100 nmol/L and the LOQs were estimated as 0.1 nmol/L for all porphyrins. Results obtained from the validation study of porphyrins showed good accuracy, precision, recovery, and stability. Finally, the proposed method was successfully applied to clinical studies on the autism spectrum disorder (ASD) diagnosis of 203 Korean children.

Performance Evaluation of Scaling based Dynamic Time Warping Algorithms for the Detection of Low-rate TCP Attacks (Low-rate TCP 공격 탐지를 위한 스케일링 기반 DTW 알고리즘의 성능 분석)

  • So, Won-Ho;Shim, Sang-Heon;Yoo, Kyoung-Min;Kim, Young-Chon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.3 s.357
    • /
    • pp.33-40
    • /
    • 2007
  • In this paper, low-rate TCP attack as one of shrew attacks is considered and the scaling based dynamic time warping (S-DTW) algorithm is introduced. The low-rate TCP attack can not be detected by the detection method for the previous flooding DoS/DDoS (Denial of Service/Distirbuted Denial of Service) attacks due to its low average traffic rate. It, however, is a periodic short burst that exploits the homogeneity of the minimum retransmission timeout (RTO) of TCP flows and then some pattern matching mechanisms have been proposed to detect it among legitimate input flows. A DTW mechanism as one of detection approaches has proposed to detect attack input stream consisting of many legitimate or attack flows, and shown a depending method as well. This approach, however, has a problem that legitimate input stream may be caught as an attack one. In addition, it is difficult to decide a threshold for separation between the legitimate and the malicious. Thus, the causes of this problem are analyzed through simulation and the scaling by maximum auto-correlation value is executed before computing the DTW. We also discuss the results on applying various scaling approaches and using standard deviation of input streams monitored.

Simultaneous Determination of Hesperidin and Glycyrrhizin in Pyungwi-san by HPLC/DAD (HPLC-DAD를 이용한 평위산 중의 Hesperidin 및 Glycyrrhizin의 동시분석법 확립)

  • Lee, Mi-Kyeong;Choe, Ok-Gyeong;Park, Jin-Ho;Cho, Jung-Hee;Kim, Do-Hoon;Baek, Ju-Hyun;Kim, Hyo-Jin;Lee, Ki-Yong;Kim, Sang-Du;Kim, Young-Choong;Sung, Sang-Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.39 no.3
    • /
    • pp.199-202
    • /
    • 2008
  • A high performance liquid chromatographic (HPLC) method for the simultaneous determination of hesperidin and glycyrrhizin was established for the quality control of traditional herbal medicinal preparation, Pyungwi-san (PWS). Separation and quantification were successfully achieved with a Waters XTerra RP18 column ($5{\mu}m$, 4.6 mm I.D. ${\times}$ 150 mm) by gradient elution of a mixture of acetonitrile and water containing 0.03% phosphoric acid (pH 2.03) at a flow rate of 1.0 ml/min. The diode-array UV/vis detector (DAD) was used for the detection and the wavelength for quantification was set at 230 nm. The presence of hesperidin and glycyrrhizin in this extract was ascertained by retention time, spiking with each authentic standard and UV spectrum. All four compounds showed good linearity $(r^2>0.995)$ in a relatively wide concentration ranges. The R.S.D. for intra-day and inter-day precision was less than 7.0% and the limits of detection (LOD) were less than 60 ng. The mean recovery of each compound was 99.0-105.6% with R.S.D. values less than 4.0%. This method was successfully applied to the determination of contents of hesperidin and glycyrrhizin in three commercial products of PWS. These results suggest that the developed HPLC method is simple, effective and could be readily utilized as a quality control method for commercial PWS products.

A Rapid Method for Determination of ATP and Its Related Compounds in Dried Fish and Shellfish Products Using HPLC (HPLC에 의한 시판수산건제품의 ATP분해생성물의 신속정량법)

  • LEE Eung-Ho;KOO Jae-Geun;AHN Chang-Bum;CHA Yong-Jun;OH Kwang-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.5
    • /
    • pp.368-372
    • /
    • 1984
  • This paper deals with a rapid method for determination of ATP and its related compounds in fish and shellfish products using high performance liquid chromatography(HPLC). The HPLC used is a HPLC/ALC-224 equiped with UV-spectrophotometer (254 nm) as detector and integrator (Yanagimoto system-1000). The column used is a stainless steel tubing ($30.0\;cm{\times}3.9\;mm\;i.d.$) packed with ${\mu}-Bon-dapak\;C_{18}$. A mixture of $1\%$ triethylamine-phosphoric acid(pH6.5) was used as an eluent and the flow rate of the eluent was controlled at 2 ml/min. For the separation of ATP and its related compounds, a standard mixture of ATP, ADP, AMP, IMP, inosine and hypoxanthine was subjected to HPLC under the above mentioned conditions. Six peaks were obtained with retention times within 20 min, and elution order were hypoxanthine, IMP, inosine, AMP, ADP and ATP. But 5'-IMP and 5'-GMP fractions were not separated by this method. In generally, IMP content in boiled-dried fish and shellfish products purchased from the market was comparatively higher than that of other nucleotides. Especially, boiled-dried big eye herring marked higher value in IMP content than other boiled-dried ones. Hypoxanthine and inosine were major components of ATP-related compounds in dried products and seasoned-dried ones. And IMP content in seasoned-dried products was higher than that of dried ones. This fact is suggested that a part of IMP in seasoned-dried ones was derived from flavoring matter (MSG, 5'-IMP and 5'-GMP) which is added during the seasoning treatment.

  • PDF

Accuracy of one-step automated orthodontic diagnosis model using a convolutional neural network and lateral cephalogram images with different qualities obtained from nationwide multi-hospitals

  • Yim, Sunjin;Kim, Sungchul;Kim, Inhwan;Park, Jae-Woo;Cho, Jin-Hyoung;Hong, Mihee;Kang, Kyung-Hwa;Kim, Minji;Kim, Su-Jung;Kim, Yoon-Ji;Kim, Young Ho;Lim, Sung-Hoon;Sung, Sang Jin;Kim, Namkug;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.3-19
    • /
    • 2022
  • Objective: The purpose of this study was to investigate the accuracy of one-step automated orthodontic diagnosis of skeletodental discrepancies using a convolutional neural network (CNN) and lateral cephalogram images with different qualities from nationwide multi-hospitals. Methods: Among 2,174 lateral cephalograms, 1,993 cephalograms from two hospitals were used for training and internal test sets and 181 cephalograms from eight other hospitals were used for an external test set. They were divided into three classification groups according to anteroposterior skeletal discrepancies (Class I, II, and III), vertical skeletal discrepancies (normodivergent, hypodivergent, and hyperdivergent patterns), and vertical dental discrepancies (normal overbite, deep bite, and open bite) as a gold standard. Pre-trained DenseNet-169 was used as a CNN classifier model. Diagnostic performance was evaluated by receiver operating characteristic (ROC) analysis, t-stochastic neighbor embedding (t-SNE), and gradient-weighted class activation mapping (Grad-CAM). Results: In the ROC analysis, the mean area under the curve and the mean accuracy of all classifications were high with both internal and external test sets (all, > 0.89 and > 0.80). In the t-SNE analysis, our model succeeded in creating good separation between three classification groups. Grad-CAM figures showed differences in the location and size of the focus areas between three classification groups in each diagnosis. Conclusions: Since the accuracy of our model was validated with both internal and external test sets, it shows the possible usefulness of a one-step automated orthodontic diagnosis tool using a CNN model. However, it still needs technical improvement in terms of classifying vertical dental discrepancies.