• 제목/요약/키워드: Separation Flow Angle

검색결과 239건 처리시간 0.027초

압전세라믹 액추에이터를 이용한 익형 후류 제어 (Control of Flow Around an Airfoil Using Piezo-Ceramic Actuators)

  • 최진;전우평;최해천
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1112-1118
    • /
    • 2000
  • The objective of this study is to increase lift and decrease drag of an airfoil at high angles of attack by delaying flow separation with piezo-ceramic actuators. The airfoil used is NACA 0012 and its chord length is 0.3m. An experiment is performed at the freestream velocity of 15m/s at which the Reynolds number based on the chord length is $2{\times}10^5$. Seven rectangular actuators are attached to the airfoil surface and move up and down based on the electric signal. Drag and lift are measured using an in-house two-dimensional force-balance and the surface pressures are also measured. At the attack angle of $16^{\circ}$, the separation point is delayed downstream due to momentum addition induced by the movement of the actuators. Lift is increased by 10%, drag is reduced by 37%, and the efficiency is increased up to 170%. The flow fields with and without control are visualized using the smoke-wire and tuft techniques.

PIV를 이용한 범포 주위의 유동장 특성 (The characteristics of the flow field around canvas kite using the PIV)

  • 배봉성;안희춘;배재현;박창두;김인옥
    • 수산해양기술연구
    • /
    • 제42권2호
    • /
    • pp.86-96
    • /
    • 2006
  • This research aims at establishing the fundamental characteristics of the kite through the analysis of the flow field around various types of kites. The approach of this study were adopted for the analysis; visualization by PIV(particle image velocimetry). Also, the lift and drag tests of kites had been performed in our previous finding(Bae et al., 2004a; Bae et al., 2004b). For this situation, models of canvas kite were deployed in the circulating water channel for the PIV test using the same conditions as in the lift and drag tests. The results obtained from the above approach are summarized as follows: Given the rectangular and triangular kites when attack angle is $20^{\circ}$, vortex by the boundary layer separation was seen in the leading edge and the flow towards the trailing edge was more turbulent. But, the inverted triangular type kite was seen to be stable without any boundary layer separation or turbulence. The increase of the attack angle resulted in the eddy in order of the rectangular, triangular and inverted triangular type. The magnitude of the eddy followed the same order. The effect of edge-eddy was biggest in the triangular type followed by the rectangular and then the inverted triangular type. The kite as the buoyancy device or the opening device will be very useful when the appropriate applications and the stability are met.

Aerodynamic forces on fixed and rotating plates

  • Martinez-Vazquez, P.;Baker, C.J.;Sterling, M.;Quinn, A.;Richards, P.J.
    • Wind and Structures
    • /
    • 제13권2호
    • /
    • pp.127-144
    • /
    • 2010
  • Pressure measurements on static and autorotating flat plates have been recently reported by Lin et al. (2006), Holmes, et al. (2006), and Richards, et al. (2008), amongst others. In general, the variation of the normal force with respect to the angle of attack appears to stall in the mid attack angle range with a large scale separation in the wake. To date however, no surface pressures have been measured on auto-rotating plates that are typical of a certain class of debris. This paper presents the results of an experiment to measure the aerodynamic forces on a flat plate held stationary at different angles to the flow and allowing the plate to auto-rotate. The forces were determined through the measurement of differential pressures on either side of the plate with internally mounted pressure transducers and data logging systems. Results are presented for surface pressure distributions and overall integrated forces and moments on the plates in coefficient form. Computed static force coefficients show the stall effect at the mid range angle of attack and some variation for different Reynolds numbers. Normal forces determined from autorotational experiments are higher than the static values at most pitch angles over a cycle. The resulting moment coefficient does not compare well with current analytical formulations which suggest the existence of a flow mechanism that cannot be completely described through static tests.

BLDC 모터 내 열.유동 해석 (Numerical investigation of thermo-flow characteristics in BLDC motor)

  • 김민수;이관수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2540-2545
    • /
    • 2007
  • A computational study of BLDC motor is presented to elucidate thermo-flow characteristics in winding and bearing with heat generation. Rotation of rotor and blades drives influx of ambient air into the rotor inlet and the inflow rates are predicted more at the front-side inlet than at the rear-side, which can be ascribed to the different pressure distribution. Recirculation zone appears in the tiny interfaces between windings, however, showing the enhanced cooling performance due to the higher velocity distribution near the rotor wall. In contrast, flow separation and incline angle of bearing groove, and relatively slower velocity distribution cause poor cooling performance and therefore the redesign of the bearing groove is significantly required.

  • PDF

Numerical Studies of Flow Across End-to-Side Distal Vascular Bypass Graft Anastomoses

  • Kim, Y.H.;Kim, J.H.;Shin, J.W.
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권4호
    • /
    • pp.339-352
    • /
    • 1992
  • A numerical simulation of the steady and pulsatile flow across the end-to-side anastomosis was performed In order to understand the role of flow dynamics in the preferential bevel opment of distal anastomotic intimal hyperplasla. The finite element technique was employed to solve two-dimensional unsteady pulsatile flow in that region. The results of the steady flow revealed that low shear stresses occur at the proximally occluded host artery and at the recirculation region in the Inner wall just distal to the toe region of the anastomosis. The nor- mal;zed wall shear rate was increased, as was the recirculation zone size in the host artery of the by-pass graft anastomosis, with increased anastomotic junction angle. In order to min imize the size of the low wall shear region which might result in the intimal hyperplasia in the by-pass graft anastomosis, a smaller anastomotic junction angle is recommended. The pulsatile flow simulation revealed flow that regions of low and ascillating mali shear do exist near the anastomosis as In the steady simulation. The shift of stagnation point depends on the pulsation of the flow. As the flow was accelerated at systole, the stagnation point moved downstream, disappered at early diastole and reappeared during late diastole. Low shear stress was also found along both walls of the occluded proximal artery. However, the diastolic flow behavior is quite different from the steady results. The vortex near the occluded artery moved downstream and inwardly during late systole, and disappeared during diastole. Recirculations proximal to the toe and heel regions were significant during diastole. Shear stress oscillation was found along the opposite wall. The results of the present study revealed that tow shear occurs at the proximally occluded host artery aud the recirculation region in the inner wall Just dlstal to the toe region of the anastomosis. The present study suggested that the regions of fluctuated wall shear stress wit flow separation is correlated with the preferential developing regions of anastomosis neointial fibrous hyperplasia.

  • PDF

터빈 제1단 정익 익렬 하류에서의 3차원 유동 및 압력손실 (Three-dimensional Flow and Aerodynamic Loss Downstream of First-Stage Turbine Vane Cascade)

  • 정재성;봉선우;이상우
    • 대한기계학회논문집B
    • /
    • 제41권8호
    • /
    • pp.521-529
    • /
    • 2017
  • 본 연구에서는 항공기 추진용 가스터빈 엔진의 고증속 터빈 제1단 정익 익렬을 새로이 구축하고, 이 정익의 기본 유동 특성에 대하여 연구하였다. 그 결과 본 연구에서 도입된 정익의 압력면에는 강한 순압력구배가 존재하는 반면, 흡입면에는 앞전에서 미드코드 근처까지 압력면보다 훨씬 더 심한 순압력구배가 존재하고 그 이후 역압력구배가 존재하였다. 두 종류의 유막법을 적용한 유동의 가시화 실험을 통하여, 정익 앞전 상류 영역에 4와류모델 말발굽와류 시스템이 존재함을 확인하였고, 입구 경계층 유동의 박리선과 재부착 유동의 박리선을 정확히 파악하였다. 이와 함께 이 고증속 정익 익렬 하류에서의 2차유동, 압력손실, 선회각, 등에 대한 데이터를 확보하였다.

Aerodynamic properties of a streamlined bridge-girder under the interference of trains

  • Li, Huan;He, Xuhui;Hu, Liang;Wei, Xiaojun
    • Wind and Structures
    • /
    • 제35권3호
    • /
    • pp.177-191
    • /
    • 2022
  • Trains emerging on a streamlined bridge-girder may have salient interference effects on the aerodynamic properties of the bridge. The present paper aims at investigating these interferences by wind tunnel measurements, covering surface pressure distributions, near wake profiles, and flow visualizations. Experimental results show that the above interferences can be categorized into two primary effects, i.e., an additional angle of attack (AoA) and an enhancement in flow separation. The additional AoA effect is demonstrated by the upward-moved stagnation point of the oncoming flow, the up-shifted global symmetrical axis of flow around the bridge-girder, and the clockwise-deflected orientation of flow approaching the bridge-girder. Due to this additional AoA effect, the two critical AoAs, where flow around the bridge-girder transits from trailing-edge vortex shedding (TEVS) to impinging leading-edge vortices (ILEV) and from ILEV to leading-edge vortex shedding (LEVS) of the bridge-girder are increased by 4° with respect to the same bridge-girder without trains. On the other hand, the underlying flow physics of the enhancement in flow separation is the large-scale vortices shedding from trains instead of TEVS, ILEV, and LEVS governed the upper half bridge-girder without trains in different ranges of AoA. Because of this enhancement, the mean lift and moment force coefficients, all the three fluctuating force coefficients (drag, lift, and moment), and the aerodynamic span-wise correlation of the bridge-girder are more significant than those without trains.

앙각을 가진 타원형 실린더 후류와 평판 경계층의 상호작용에 대한 연구 (Interaction between Turbulent Boundary Layer and Wake behind an Elliptic Cylinder at Incidence)

  • 최재호;이상준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.465-471
    • /
    • 2000
  • The flow characteristics around an elliptic cylinder with axis ratio of AR=2 located near a flat plate were investigated experimentally to study the interaction between the cylinder wake and the turbulent boundary layer. The pressure distributions on the cylinder surface and on the flat plate were measured with varying the angle of attack of the cylinder. In addition, the velocity profiles of wake behind the cylinder were measured using a hot-wire anemometry As the angle of attack increases, the location of peak pressure on the windward and leeward surfaces of the cylinder moves toward the rear and front of the cylinder, respectively. At positive angles of attack, the position of the minimum pressure on the flat plate surface is moved downstream, but it is moved upstream at negative angles of attack. With increasing the angle of attack, the vortex shedding frequency is gradually decreased and the critical angel of attack exists in terms of the gap ratio. By installing the elliptic cylinder at negative angle of attack, the turbulent boundary layer over the flat plate is disturbed more than that at positive incidence. This may be attributed to the shift of separation point on the lower surface of the cylinder according to the direction of the angle of attack.

  • PDF

앙각을 가진 타원형 실린더 후류와 평판경계층의 상호작용에 대한 연구 (Interaction between Turbulent Boundary Layer and Wake Behind an Elliptic Cylinder at Incidence)

  • 최재호;이상준
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.976-983
    • /
    • 2000
  • The flow characteristics around an elliptic cylinder with axis ratio of AR=2 located near a flat plate were investigated experimentally to study the interaction between the cylinder wake and the turbulent boundary layer. The pressure distributions on the cylinder surface and on the flat plate were measured with varying the angle of attack of the cylinder. In addition, the velocity profiles of wake behind the cylinder were measured using a hot-wire anemometry As the angle of attack increases, the location of peak pressure on the windward and leeward surfaces of the cylinder moves toward the rear and front of the cylinder, respectively. At positive angles of attack, the position of the minimum pressure on the flat plate surface is moved downstream, but it is moved upstream at negative angles of attack. With increasing the angle of attack, the vortex shedding frequency is gradually decreased and the critical angle of attack exists in terms of the gap ratio. By installing the elliptic cylinder at negative angle of attack, the turbulent boundary layer over the flat plate is disturbed more than that at positive incidence. This may be attributed to the shift of separation point on the lower surface of the cylinder due to the presence of a ground plate nearby.

가스터빈용 열교환기의 주름진 덕트에서 종횡비 변화가 열전달 특성에 미치는 영향 (Effects of Duct Aspect Ratio on Heat Transfer in Wavy Duct of Heat Exchanger of Gas Turbine)

  • 김한호;황상동;조형희;최재호;전승배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.339-344
    • /
    • 2001
  • The present study investigates convective heat/mass transfer and flow characteristics in wavy ducts of primary surface heat exchanger. Experiments using a naphthalene technique are carried out to determine the local transfer characteristics for flow in the corrugated wall duct. The aspect ratios of the rectangular duct cross-section are 7.3, 4.7 and 1.8 with a corrugation angle of $145^{\circ}$. The Reynolds numbers, based on the duct hydraulic diameter, are ranged from 1000 to 5000. The local heat/mass transfer measurement is conducted in the spanwise directions. The results show that Tayler-Gortler vortices exist on the pressure surface. Flow separation on the suction surface appears at a high Reynolds number resulting in a sharp decrease in the local transfer rates, but relatively high transfer rates are obtained in the reattachment region.

  • PDF