• Title/Summary/Keyword: Sensitivity to particulate properties

Search Result 6, Processing Time 0.019 seconds

Assessment of Inhalation Dose Sensitivity by Physicochemical Properties of Airborne Particulates Containing Naturally Occurring Radioactive Materials (천연방사성물질을 함유한 공기 중 부유입자 흡입 시 입자의 물리화학적 특성에 따른 호흡방사선량 민감도 평가)

  • Kim, Si Young;Choi, Cheol Kyu;Park, Il;Kim, Yong Geon;Choi, Won Chul;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.4
    • /
    • pp.216-222
    • /
    • 2015
  • Facilities processing raw materials containing naturally occurring radioactive materials (NORM) may give rise to enhanced radiation dose to workers due to chronic inhalation of airborne particulates. Internal radiation dose due to particulate inhalation varies depending on particulate properties, including size, shape, density, and absorption type. The objective of the present study was to assess inhalation dose sensitivity to physicochemical properties of airborne particulates. Committed effective doses to workers resulting from inhalation of airborne particulates were calculated based on International Commission on Radiological Protection 66 human respiratory tract model. Inhalation dose generally increased with decreasing particulate size. Committed effective doses due to inhalation of $0.01{\mu}m$ sized particulates were higher than doses due to $100{\mu}m$ sized particulates by factors of about 100 and 50 for $^{238}U$ and $^{230}Th$, respectively. Inhalation dose increased with decreasing shape factor. Shape factors of 1 and 2 resulted in dose difference by about 18 %. Inhalation dose increased with particulate mass density. Particulate mass densities of $11g{\cdot}cm^{-3}$ and $0.7g{\cdot}cm^{-3}$ resulted in dose difference by about 60 %. For $^{238}U$, inhalation doses were higher for absorption type of S, M, and F in that sequence. Committed effective dose for absorption type S of $^{238}U$ was about 9 times higher than dose for absorption F. For $^{230}Th$, inhalation doses were higher for absorption type of F, M, and S in that sequence. Committed effective dose for absorption type F of $^{230}Th$ was about 16 times higher than dose for absorption S. Consequently, use of default values for particulate properties without consideration of site specific physiochemical properties may potentially skew radiation dose estimates to unrealistic values up to 1-2 orders of magnitude. For this reason, it is highly recommended to consider site specific working materials and conditions and use the site specific particulate properties to accurately access radiation dose to workers at NORM processing facilities.

Development and Evaluation of an Inexpensive Weighing Chamber for Particulate Filters (미세먼지 여지의 무게 측정을 위한 저비용 계량챔버 개발 및 성능평가)

  • Jun-Hyun Park;Ho-Jin Lim
    • Journal of Environmental Science International
    • /
    • v.32 no.2
    • /
    • pp.131-137
    • /
    • 2023
  • Filter and microbalance sensitivity in measuring fine particulate matter mass is greatly influenced by particulate properties and environmental factors. Temperature and humidity control inside a measuring chamber with a microbalance, and neutralization of static charges on filters are essential for consistent filter weighing. Commercial weighing chambers are expensive with a unit price of tens of millions won. This study developed an inexpensive weighing chamber for weighing fine particulate matter and evaluatedits weighing performance. A microbalance with 1 ㎍ precision was used to measure the weight of a filter. The microbalance was set in a transparent acrylic enclosure (100 × 60 × 65 cm3) equipped with temperature and humidity control equipments. Weighing performance of the chamber was examined using Teflon filters with or without different particulate sample types. Temperature and humidity were maintained at approximately 23.2±1.2 ℃ and 36.2±1.8℃ for 8 days, respectively.

Frequency Dependent Magnetoelectric Responses in [0.948 Na0.5K0.5NbO3-0.052 LiSbO3]-[Co1-xZnxFe2O4] Particulate Composites

  • Choi, Moon Hyeok;Noh, Byung Il;Yun, Woosik;Jung, Chaewon;Yang, Su Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.3
    • /
    • pp.303-307
    • /
    • 2022
  • Magnetoelectric (ME) properties of 3-0 type particulate composites have been investigated with respect to application features for reliable magnetic sensitivity and magnetically-induced output voltage. In order to figure out the magnetoelectric characteristics in the ME composites, frequency dependent ME responses were studied from [0.948 Na0.5K0.5NbO3-0.052 LiSbO3]-[Co1-xZnxFe2O4] (NKNLS)/Co1-xZnxFe2O4 (CZFO, x=0, 0.1, and 0.2). As a result, the maximal αME of 23.15 mV/cm·Oe was achieved from the NKNLS-CZFO (xZn = 0.1) composites at resonance frequency of 315 kHz and Hdc = 0 Oe. From the frequency dependent ME responses, it is clearly described that the self-biased ME composites can be used for applications as both magnetic sensors and energy harvesters, respectively.

RSA vs DEM in view of particle packing-related properties of cementitious materials

  • Li, Kai;Stroeven, Piet
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.83-91
    • /
    • 2018
  • Various systems for simulating particulate matter are developed and used in concrete technology for producing virtual cementitious materials on the different levels of the microstructure. Basically, the systems can be classified as two distinct families, namely random sequential addition systems (RSAs) and discrete element methods (DEMs). The first type is hardly being used for this purpose outside concrete technology, but became popular among concrete technologists. Hence, it is of utmost relevance to compare the two families in their capabilities, so that the reliability of produced data can be estimated. This paper pursues to do this on the basis of earlier published material of work performed by a succession of PhD students in the group of the second author. Limited references will be given to external sources.

Anti-oxidant and Anti-pollution Composition Containing the Extract of Nypa fruticans Wurmb, Saussurea neoserrata, Codium fragile and Enteromorpha compressa

  • Choi, Go-Eun;Lee, Gil-Hyun;Hyun, Kyung-Yae
    • Biomedical Science Letters
    • /
    • v.26 no.3
    • /
    • pp.157-163
    • /
    • 2020
  • Long-term exposure to environmental pollutants can impair the human skin's barrier function and promote skin aging mechanisms. The visible consequences of these effects are dryness, wrinkles, black spots and worsening skin sensitivity. As awareness of the effects of environmental stressors on the skin has recently increased, consumers' demand for cosmetics that can provide anti-pollution effects is increasing. In this study, the possibility of anti-pollution cosmetic material was investigated by measuring the inhibitory effect of free radicals using a mixture of Nypa fruticans Wurmb (NF), Saussurea neoserrata (SN), Codium fragile (CF) and Enteromorpha compressa (EC), which has anti-inflammatory and antioxidant effects against irritation caused by dust. Combining the experimental results of a mixture of NF, SN, CF and EC by induction of fine dust stimulation, inhibition of inflammatory factors (PGE2) and intracellular free radicals (ROS) by inhibiting effects were significant, indicating the possibility of use as anti-pollution cosmetics. The most plants used as sources of anti-pollution cosmetic ingredients contain antioxidants as active substances. In our highly industrialized and chemically polluted world, it is not surprising that most plants used as sources of anti-pollution cosmetic ingredients contain antioxidants as active substances. Considering our results, it can be suggested that this anti-pollutant consisting of NF, SN, CF and EC may be a good ingredient for skincare products for the cosmetic industry due to their antioxidant properties, which may especially alter skin aging.

Field Performance Evaluation of Candidate Samplers for National Reference Method for PM2.5 (PM2.5 국가기준측정장비 선정을 위한 비교 측정 연구)

  • Lee, Yong Hwan;Park, Jin Su;Oh, Jun;Choi, Jin Soo;Kim, Hyun Jae;Ahn, Joon Young;Hong, You Deog;Hong, Ji Hyung;Han, Jin Seok;Lee, Gangwoong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.157-163
    • /
    • 2015
  • To establish National Reference Method (NRM) for $PM_{2.5}$, operational performance of 5 different commercial gravimetric-based $PM_{2.5}$ measuring instruments was assessed at Bulkwang monitoring station from January 23, 2014 to February 28, 2014. First, physical properties, design, and functional performance of the instruments were assessed. Evaluation was carried out to determine whether operating method for the instruments and levels of QA/QC activities meet the data quality objectives (DQOs). To verify whether DQOs were satisfied, reproducibility of QA/QC procedures, accuracy, relative sensitivity, limit of detection, margin of error, and coefficient of determination of the instruments were also evaluated. Results of flow rate measurement of 15 candidate instruments indicated that all the instruments met performance criteria with accuracy deviation of 4.0% and reproducibility of 0.6%. Comparison of final $PM_{2.5}$ mass concentrations showed that the coefficient of determination ($R^2$) values were greater than or equal to 0.9995, and concentration gradient ranged from 0.97 to 1.03. All the instruments satisfied criteria for NRM with the estimated precision of 1.47~2.60%, accuracy of -1.90~3.00%, and absolute accuracy of 1.02~3.12%. This study found that one particular type of measuring instrument was proved to be excellent, with overall evaluation criteria satisfied.