• Title/Summary/Keyword: Sensitivity method

Search Result 5,627, Processing Time 0.043 seconds

Analysis of Causes for Primary Treatment Failure of Pulmonary Tuberculosis (폐결핵환자에서 초치료실패에 대한 요인 분석)

  • Park, Seung-Kyu;Choi, In-Hwan;Kim, Cheon-Tae;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.6
    • /
    • pp.1234-1244
    • /
    • 1997
  • Background : Nowadays drug resistant tuberculosis is making problems in the treatment of pulmonary tuberculosis and its number is increasing. Several reasons for this are considered including irregular medication, poor drug compliance and wrong regimens. But there are treatment failure cases in spite of regular medication with short-term standard regimens. We reviewed clinical data of 50 patients to find out possible causes of this. Method : Subject of this study was 50 patients who failed in the primary treatment of pulmonary tuberculosis in spite of regular medication with short-term standard regimens. All of them were under treatment with secondary regimens in National Masan Tuberculosis Hospital on Oct 1996. The patient's records were analyzed retrospectively and direct interviews with patients were done. Results : There were relatively more patients in the age of 20th. Male overwhelmed in number. There were smoking in 22 patients and drinking in 24 patients during medication. 17(34%) patients had family history of tuberculosis. Public health center was the most common site for the initial diagnosis among medical institutes. 42 patients had subjective symptoms for pulmonary tuberculosis. 38 patients got sufficient explanation from medical institute about tuberculosis and medication courses. 24 patients had bilateral lesions on chest X-ray film and 43 patients had cavitary lesions. 29 patients had past history for pulmonary tuberculosis with regular medication. The results of drug sensitivity test showed resistance in 41 patients of whom we could get the results. Conclusion : Main cause of treatment failure of pulmonary tuberculosis in spite of regular medication with short-term standard regimens was drug resistance. Several factors were considered to be related to high prevalence of drug resistance, including age of 20th, male, family history for tuberculosis, bilateral lesions or remaining cavitary lesion on chest X-ray film.

  • PDF

Risk Factors of Extubation Failure and Analysis of Cuff Leak Test as a Predictor for Postextubation Stridor (발관 실패의 위험 인자 및 발관 후 천음과 재삽관의 예측에 있어 Cuff Leak Test 의 유용성과 의미 분석)

  • Lim, Seong Yong;Suh, Gee Young;Kyung, Sun Yong;An, Chang Hyeok;Park, Jung Woong;Lee, Sang Pyo;Jeong, Sung Hwan;Ham, Hyoung Suk;Ahn, Young Mee;Lim, Si Young;Koh, Won Jung;Chung, Man Pyo;Kim, Ho Joong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.1
    • /
    • pp.34-40
    • /
    • 2006
  • Background: Extubation failure was associated with poor prognosis and high hospital mortality. Cuff leak test (CLT) has been proposed as a relatively simple method for detecting laryngeal obstruction that predispose toward postextubation stridor (PES) and reintubation. We examined the risk factors of extubation failure and evaluated the usefulness and limitation of CLT for predicting PES and reintubation. Methods: Thirty-four consecutive patients intubated more than 24 hours were examined. The subjects were evaluated daily for extubation readiness, and CLT was performed prior to extubation. Several parameters in the extubation success and failure group were compared. The accuracy and limitation of CLT were evaluated after choosing the thresholds values of the cuff leak volume (CLV) and percentage (CLP). Results: Of the 34 patients studied, 6 (17.6%) developed extubation failure and 3 (8.8%) were accompanied by PES. The patients who had extubation failure were more likely to have a longer duration of intubation and more severe illness. The patients who developed PES had a smaller cuff leak than the others: according to the CLV ($22.5{\pm}23.8$ vs $233.3{\pm}147.1ml$, p=0.020) or CLP ($6.2{\pm}7.3$ vs $44.3{\pm}24.7%$, p=0.013). The best cut off values for the CLV and CLP were 50ml and 14.7%, respectively. The sensitivity, negative predictive value, and specificity of CLT were relatively high, but the positive predictive value was low. Conclusion: The likelihood of developing extubation failure increases with increasing severity of illness and duration of intubation. A low CLV or CLP (<50ml or 14.7%) is useful in identifying patients at risk of PES, but the CLT is not an absolute predictor and should not be used an indicator for delaying extubation.

Antibiotic Susceptibility of Bacteria Isolated from Infected Root Canals (감염근관에서 분리 배양한 세균의 수종 항생제에 대한 감수성 조사)

  • Lim, Sang-Soo;Kim, Mi-Kwang;Min, Jeong-Beom;Kim, Min-Jung;Park, Soon-Nang;Hwang, Ho-Keel;Kook, Joong-Ki
    • Korean Journal of Microbiology
    • /
    • v.42 no.3
    • /
    • pp.185-194
    • /
    • 2006
  • The aim of this study was to identify the bacteria isolated from endodontic lesions by cell culture and to determine the antimicrobial susceptibility of them against 8 antibiotics. The necrotic pulpal tissues were collected from 27 infected root canals, which were diagnosed as endodontic infection. Samples were collected aseptically from the infected pulpal tissue of the infected root canals using a barbed broach and a paper point. The cut barbed broaches and paper points were transferred to an eppendorf tube containing $500{\mu}l\;of\;1{\times}PBS$. The sample solution was briefly mixed and plated onto a BHI-agar plate containing 5% sheep blood. The agar plates were incubated in a $37^{\circ}C$ anaerobic chamber for 2 to 5 days. The bacteria grown on the agar plates were identified by comparison of 16S rRNA gene (rDNA) sequencing method at the species level. To test the sensitivity of the bacteria isolated from the infected root canals against 8 antibiotics, minimum inhibitory concentrations (MIC) were determined using broth dilution assay. The data showed that 101 bacterial strains were isolated and were identified. Streptococcus spp. (29.7%) and Actinomyces spp. (21.8%) were predominantly isolated. The 9 strains were excluded in antimicrobial susceptibility test because they were lost during the experiment or were not grown in broth culture. The percentage of bacteria susceptible for each antibiotic in this study was clindamycin, 87.0% (80 of 92); tetracycline, 75.0% (69 of 92); cefuroxime axetil, 75.0% (69 of 92); amoxicillin + clavulanic acid (5:1), 71.7% (66 of 92); penicillin G, 66.3% (61 of 92); erythromycin, 66.3% (61 of 92); amoxicillin, 44.6% (41 of 92); and ciprofloxacin, 31.5% (29 of 92). The susceptibility pattern of 8 antibiotics was dependent on the host of the bacteria strains rather than the kinds of bacterial species. These results indicate that antibiotic susceptibility test should be performed when antibiotics are needed for the treatment of infected root canals.

Effects of an $Al_2$O$_3$Surfasce Protective Layer on the Sensing Properties of $SnO_2$Thin Film Gas Sensors (Al$_2$O$_3$ 표면 보호층이 박막형 $SnO_2$ 가스센서의 감지 특성에 미치는 영향)

  • Seong, Gyeong-Pil;Choe, Dong-Su;Kim, Jin-Hyeok;Mun, Jong-Ha;Myeong, Tae-Ho
    • Korean Journal of Materials Research
    • /
    • v.10 no.11
    • /
    • pp.778-783
    • /
    • 2000
  • Effects of the $Al_2$O$_3$surface protective layer, deposited on the SnO$_2$sensing layer by aerosol flame deposition (AFD) method, on the sensing properties of SnO$_2$thin film ags sensors were investigated.Effects of Pt doping to the $Al_2$O$_3$surface protective layer on the selectivity of CH$_4$ gas were also investigated. 0.3$\mu\textrm{m}$ thick SnO$_2$thin sensing layers on Pt electrodes were prepared by R.F. magnetron sputtering with R.F. power of 50 W, at working pressure of 4mTorr, and at 20$0^{\circ}C$ for 30 min. $Al_2$O$_3$surface protective layers on SnO$_2$layers were prepared by AFD using a diluted aluminum nitrade (Al(NO$_3$).9$H_2O$) solution. The sensitivity of CO gas in the SnO$_2$gas sensor with an $Al_2$O$_3$surface protective layer was significantly decreased. But that of CH$_4$gas remained almost same with pure SnO$_2$gas sensor. This result shows that the selectivity of CH$_4$gas is increased because of the $Al_2$O$_3$surface protective layer. In the case of SnO$_2$gas sensors with Pt-doped $Al_2$O$_3$surface protective layers, low sensing property to CO gas and high sensing property to CH$_4$were observed. This results in the increasing of selectivity of CH$_4$gas selectivity are discussed.

  • PDF

Valuation of Mining Investment Projects by the Real Option Approach - A Case Study of Uzbekistan's Copper Mining Industry - (실물옵션평가방법에 의한 광산투자의 가치평가 -우즈베키스탄 구리광산업의 사례연구를 중심으로-)

  • Makhkamov, Mumm Sh.;Kim, Dong-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1634-1647
    • /
    • 2007
  • "To invest or not to invest?" Most business leaders are frequently faced with this question on new and ongoing projects. The challenge lies in deciding what projects to choose, expand, contract, defer, or abandon. The project valuation tools used in this process are vital to making the right decisions. Traditional tools such as discounted cash flow (DCF)/net present value (NPV) assume a "fixed" path ahead, but real world projects face uncertainties, forcing us to change the path often. Comparing to other traditional valuation methods, the real options approach captures the flexibility inherent to investment decisions. The use of real options has gained wide acceptance among practitioners in a number of several industries during the last few decades. Even though the options are present in all types of business decisions, it is still not considered as a proper method of valuation in some industries. Mining has been comparably slow to adopt new valuation techniques over the years. The reason fur this is not entirely clear. One possible reason is the level and types of risks in mining. Not only are these risks high, but they are also more numerous and involve natural risks compared with other industries. That is why the purpose of this study is to deal with a more practical approach to project valuation, known as real options analysis in mining industry. This paper provides a case study approach to the copper mining industry using a real options analysis. It shows how companies can minimize investment risks, exercise flexibility in decision making and maximize returns.

  • PDF

A Study on the Experience Design and Practical Use of Experience by On- and Off-Line Environment (온 오프라인 환경에 따른 경험의 활용과 경험디자인에 관한 연구)

  • Yoon, Se-Kyun;Kim, Tae-Kyun;Kim, Min-Su
    • Archives of design research
    • /
    • v.18 no.3 s.61
    • /
    • pp.5-14
    • /
    • 2005
  • In the past, consumers sought utilitarian and defensive consumption in an attempt to move to a balanced state. However, today's consumers go beyond this to consume more for hedonic and creative reasons if not for sheer pleasure. There is an obvious shift from the type of consumption that satisfies basic desires through the characteristics, convenience and quality of goods and services to an era of 'experiential consumption,' in which consumers pursue distinctive value systems and way of life along with a total 'experience' provided by such goods and services. Such a sign of the times has given birth to the experience design that aims at maximizing the strategic use of experiences in design. Research on this subject is gradually increasing. The research and application peformed even without the proper understanding about the concepts and purposes of experience design, however, is likely to deviate from the true nature in its process or method. Also, they are likely to cause rather than solve problems. Accordingly, this study examined the meaning of experience from a spatial aspect, focusing on areas that recognize the experience as economically valuable, making the most of it substantively. The main concept of experience practical used on-line is enhancement of the usability of a medium by reflecting the experience of users accustomed to both off-line and on-line environments and materializing the environment doser to and more familiar with the users, thus allowing them to comfortably use the medium. This is to allow the users to feel more comfortable. The experience practical used pertaining to off-line is a tool to fulfill the sensitivity of users, with efforts to create new, future-oriented consumer values. This, based on the understanding of consumer behavior, seeks to maximize the consumption experience of consumers by providing a combination of sensual and sensitive experiences as well as to enhance the existing experiences by permitting users to create new, extended experiences from the fixed characteristics of products. Furthermore, it aims to provide consumers with the hedonic experience of play through the joy, fun and uniqueness of alternate experiences.

  • PDF

An Outbreak of Epidemic Keratoconjunctivitis by Adenovirus Type 8 in a Neonatal Intensive Care Unit (신생아 중환자실에서의 아데노바이러스 8형에 의한 유행성 각결막염의 발생)

  • Park, Na-Ri-Mi;Na, Ji-Youn;Joung, Kyoung-Eun;Lee, Ji-Na;Kim, Ee-Kyung;Kim, Han-Suk;Kim, Seong-Joon;Song, Jung-Suk;Oh, Hyang-Soon;Lee, Hoan-Jong;Choi, Jung-Hwan
    • Neonatal Medicine
    • /
    • v.15 no.1
    • /
    • pp.44-53
    • /
    • 2008
  • Purpose : Epidemic keratoconjunctivitis (EKC) caused by adenovirus is a highly contagious disease, which has been reported as outbreaks involving adults in the community. However, there has been no report on EKC outbreak by adenovirus in a neonatal intensive care unit (NICU) in Korea. Aims of this study were to investigate the EKC outbreak by adenovirus type 8 in NICU and to confirm an effectiveness of polymerase chain reaction (PCR) for diagnosis. Methods : Conjunctival swab or nasopharyngeal aspirate specimens were taken from all patients and tested by viral culture and PCR. Adenovirus serotype was determined by sequencing of PCR product of selected region of hexon gene using the virus isolates or specimens. Results : An outbreak of EKC occurred which was involving 12 preterm infants in the NICU of the Seoul National University Children's Hospital between July 12th and August 1st, 2005. Three hospital staffs and one family member of the neonate were also affected. Adenovirus was detected in 12/12 (100%), 6/11 (54.5%) by PCR and virus culture, respectively. Eleven PCR-positive neonates were identified as serotype 8 by sequencing. The first affected 4 babies have had routine ROP (retinopathy of prematurity) examinations one week ago. While previous outbreaks were sustained for a few months, the event in our unit was controlled without complications in 3 weeks. Conclusion : We analyzed the EKC outbreak by adenovirus type 8 in NICU. Adenovirus serotype was identified by PCR and sequencing with high sensitivity for the first time in Korea, so we suggest this method can be very useful for rapid diagnosis and infection control.

Convenient Nucleic Acid Detection for Tomato spotted wilt virus: Virion Captured/RT-PCR (VC/RT-PCR) (Tomato spotted wilt virus를 위한 간편한 식물바이러스 핵산진단법: Virion Captured/RT-PCR (VC/RT-PCR))

  • Cho Jeom-Deog;Kim Jeong-Soo;Kim Hyun-Ran;Chung Bong-Nam;Ryu Ki-Hyun
    • Research in Plant Disease
    • /
    • v.12 no.2
    • /
    • pp.139-143
    • /
    • 2006
  • Virion captured reverse transcription polymerase chain reaction (VC/RT-PCR) could detect plant virus quickly and accurately. In the VC/RT-PCR, no antibody is needed unlike immuno-captured RT-PCR (IC/RT-PCR) which had been improved method of RT-PCR for plant viruses, and virus nucleic acids can be obtained easily within 30minutes by property of polypropylene PCR tube which is hold and immobilized viral particles on its surface. For the virion capture of Tomato spotted wilt virus (TSWV), the extraction buffer was tested. The optimum macerating buffer for TSWV was 0.01M potassium phosphate buffer, pH 7.0, containing 0.5% sodium sulfite. The viral crude sap was incubated for 30 min at $4^{\circ}C$. The virions in the PCR tubes were washed two times with 0.01M PBS containing 0.05% Tween-20. The washed virions were treated at $95^{\circ}C$ immediately for 1 min containing RNase free water and chilled quickly in the ice. Disclosed virions' RNAs by heat treatment were used for RT-PCR. Dilution end point of $10^{-5}$ from plant's crude sap infected with TSWV showed relatively higher detection sensitivity for VC/RT-PCR. During multiple detection using two or more primers, interference was arisen by interactions between primer-primer and plant species. The result of multiplex RT-PCR was influenced by combinations of primers and the kind of plant, and the optimum extraction buffer for the multiplex detection by VC/RT-PCR should be developed.

Differences in the Clinical Characteristics of Children with Urinary Tract Infections Based on the Results of $^{99m}Tc$-Dimercaptosuccinic Acid Renal Scanning (요로감염 소아에서 입원 초기 시행한 DMSA 신 스캔 결과에 따른 임상양상의 차이에 대한 연구: DMSA 신 스캔의 임상적 의미)

  • Kim, Dong Ouk;Lee, Sang Min;Lee, Jeong Bong;Ko, Young Bin;Kim, Su Jin
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • Purpose: The $^{99m}Tc$-Dimercaptosuccinic acid (DMSA) renal scan is used primarily for the diagnosis of renal scarring and acute pyelonephritis in children with urinary tract infections (UTI). This study aimed to evaluate clinical differences based on the positive or negative results of DMSA scans and kidney ultrasonography (US) in pediatric UTI. Method: We retrospectively reviewed 142 pediatric patients with UTI who were admitted to Myongji Hospital from January 2004 to December 2012. We performed a comparative analysis of clinical parameters such as age, sex, white blood cell (WBC) count, neutrophil count, blood urea nitrogen (BUN) level, creatinine (Cr) level, C-reactive protein (CRP) level, and durations of hospitalization and fever, grouped by the results of the DMSA scans and kidney US. Results: The mean age of the patients was $33.8{\pm}48.3$ months, and 78 (55%) were male. Fifty-two patients had abnormal DMSA findings, and 71 patients had abormal kidney US findings (test positive groups). In the DMSA scan positive group, there were significant differences in age, WBC counts, neutrophil counts, CRP level, BUN level, Cr level, hospitalization duration, number of abnormal findings on kidney US, and incidence of vesicoureteral reflux (VUR) compared with the scan negative group. The kidney US positive group had significant differences in age, neutrophil count, CRP level, BUN level, Cr level, hospitalization duration, number of abnormal findings on the DMSA scans, and more frequent VUR compared with the US negative group. Conclusion: Our data suggest that there were no major differences in clinical parameters based on the results of the DMSA scans compared with kidney US in pediatric UTI. However, as kidney US and DMSA scan were performed to predict VUR, the sensitivity and negative predictive value was increased.

$^{99m}Tc$-HMPAO-labelled Leucocyte Scintigraphy in the Diagnosis of Infection after Total Knee Replacement Arthroplasty (인공슬관절 전치환술 환자에서 $^{99m}Tc$-HMPAO-백혈구 스캔을 이용한 인공관절 감염의 진단)

  • Park, Dong-Rib;Kim, Jae-Seung;Ryu, Jin-Sook;Moon, Dae-Hyuk;Bin, Seong-Il;Cho, Woo-Shin;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.4
    • /
    • pp.413-421
    • /
    • 1999
  • Purpose: This study was performed to evaluate the usefulness of $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy for diagnosing prosthetic infection after total knee replacement arthroplasty without the aid of following bone marrow scintigraphy Materials and Methods: The study subjects were 25 prostheses of 17 patients (one man and 16 women, mean age. 65 years) who had total knee replacement arthroplasty. After injection of $^{99m}Tc$-HMPAO-labelled leucocyte, the whole body planar and knee SPECT images were obtained in all patients. The subjects were classified into three groups according to clinical suspicion of prosthetic infection. Group A (n=11) with high suspicion of infection; Group B (n=6) with equivocal suspicion of infection, and Group C (n=8) with asymptomatic contralateral prostheses. Final diagnosis of infection was based on surgical, histological and bacteriological data and clinical follow-up. Results: Infection was confirmed in 13 prostheses (11 in Group A and 2 in Group B). All prostheses in Group A were true positive. There were two true positives, one false positive and three true negatives in Group B, and six true negatives and two false positives in Group C. Overall sensitivity, specificity, and accuracy for diagnosis of the infected knee prosthesis were 100%, 75% and 88%, respectively Conclusion: $^{99m}Tc$-HMPAO-labelled leucocyte scintigraphy is a sensitive method for the diagnosis of infected knee prosthesis. However, false positive uptakes even in asymptomatic prosthesis suggest that bone marrow scintigraphy may be needed to achieve improved specificity.

  • PDF