• Title/Summary/Keyword: Sensitivity analysis

Search Result 7,163, Processing Time 0.049 seconds

Comparison of Family Support and Mental Health Between the Rural and Urban Elderly (농촌과 도시지역 노인의 가족지지와 정신건강에 관한 비교)

  • Min, Kyung-Hwa;Kim, Sang-Soon
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.175-185
    • /
    • 1995
  • This study is to compare family support and mental health between the rural and the urban elderly. In order to do that I collected the data through questioning 238 people in 3 urban areas in Busan and 201 people in 9 rural areas near Daegu. The degree of their family support is 36.70 on the average in the rural area and 40.77 in the urban area. The degree of family support of urban elderly is a little higher. According to general characters between the differences of family support in both areas, in the rural area there are differences in sex, age, whether they have a spouse or not, education level, financial state, number of children, number of co living, status of co living, subjective health status, amount of pocket money and how much they are participating in leisure activity. In the urban area there are differences in sex, whether they have a spouse or not, religion, financial state, number of co living, status of co living, subjective health status, amount of pocket money, how much they are participating in leisure activity and house pattern. In the stepwise multiple regression analysis the main variables that affect degree of family support in the rural area are age, whether they have a spouse or not and financial state which account for 33% of the total variance and in the urban area are subjective health status, financial state, whether they have a spouse or not and number of co-living which account for 35%. Health status is better in the urban area(average 36.87) than in the rural area(57.42). In each item the people whose mark was more than 75%(low) have Depression 8.4%, Somatization 8.0% in the urban area and Somatization 8.5%, Depression 8.5%, Anxiety 4.0%, Phobic anxiety 4.0%, Obsessive compulsive reaction 2.5%, Hostility 2.0%, Paranoid ideation 2.0%, Psychoticism 1.5% and Interpersonal sensitivity 1.5% in the rural area. In the mental health condition, on the basis of 4 points in both areas, the average is Somatization(rural : 1.69, urban : 1.51), Depression (rural : 1.64, urban : 1.37) and Obsessive compulsive reaction(rural : 1.33, urban : 0.99). According to the differences between mental health conditions by general characters, in the rural area the differences are presented in sex, age, whether they have a spouse or not, religion, education level, financial state, number of children, status of co living, subjective health status, amount of pocket money and how much they are participating in leisure activity, in the urban area the differences are presented in sex, whether they have a spouse or not, religion, financial state, number of co living, status of co living, subjective health status, house pattern, amount of pocket money and how much they are participating in leisure activity. In the stepwise multiple regression analysis the main variables that affect mental health condition in the rural are family support degree subjective health status, religion sex, age and financial state which account for 43% of the total and in the urban area are family support degree, subjective health status and financial state which account for 51%. In the matter of family support degree and mental health condition the rural area was -0.4555, of urban area was -0.6446. The rural area that has a high percentage in family support degree and mental health condition Depression was -0.5036, Psychoticism was -0.4265 in the urban area Psychoticism was -0.6452, Depression was -0.5955. Family support has a great influence on mental health of old people and family support and mental health condition can be different according to living area. So in their problems nursing intervention through family and nursing strategies according to living area should be established.

  • PDF

Increased Peripheral NK Cell Fraction and Their Cytolytic activity in Patients with History of Recurrent Spontaneous Abortion (말초혈액 자연살해세포 분획 및 세포용해 활성도 분석을 통한 습관성 유산 위험군의 진단적 유용성에 관한 연구)

  • Choi, Ji-Young;Hwang, Su-Jin;Han, Ae-Ra;Yoo, Ji-Hee;Park, Dong-Wook;Park, Chan-Woo;Kim, Hye-Ok;Cha, Sun-Hwa;Kim, Jin-Young;Song, In-Ok;Koong, Mi-Kyoung;Kang, In-Soo;Yang, Kwang-Moon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.37 no.2
    • /
    • pp.115-124
    • /
    • 2010
  • Objective: To testify whether the increased peripheral blood natural killer (pbNK) cells fraction and their cytolytic activity could coincide with patient's history of recurrent spontaneous abortion (RSA) and to evaluate these factors are can be valuable diagnostic markers in RSA. Methods: Women with a history of RSA comprised the patient group (n=35). Normal fertile women, who were experienced at least one healthy term birth without history of infertility or recurrent miscarriage, were included as the healthy control group (n=15). The pbNK cells of $CD3^-/CD56^+/CD16^+$ and their cytolytic activities against K562 cells were measured by flow cytometry and the values were compared between study and control groups. Results: Proportions of pbNK cells among peripheral blood monocytes (PBMC) ($14.2{\pm}5.2$ vs. $9.4{\pm}3.7%$, p=0.002, 95% confidence interval [CI], 1.8 to 7.8) was significantly higher in the patient group. The odds ratio of having RSA history was increased as 8.4 folds (59% of sensitivity, 80% of specificity, and 95% CI: 2.0 to 35.8) in patients who showed pbNK cells fraction above 12.1% which was determined as cut-off value by using ROC curve analysis. The cytolytic activities of pbNK cells which measured by three different ratio of effecter pbNK cells to target K562 cells and calculated by the percent of cytolytic K562 cells, were significantly higher in study group than that of control group (in 50:1 ratio, $48.3{\pm}19.0$ vs. $31.3{\pm}11.9%$, p=0.002; in 25:1 ratio, $37.0{\pm}18.1$ vs. $20.2{\pm}9.2%$, p<0.001; in 12.5:1 ratio, $23.5{\pm}12.7$ vs. $12.4{\pm}7.3%$, p=0.001). With the cut-off values of cytolytic activity of pbNK cells as 43.1% (50:1), 26.9% (25:1), and 17.4% (12.5:1) each, the risk of having RSA history was increased by 10.0, 11.4, and 15.0 folds in patients who had increased in each effector of pbNK to target of K562 cells ratio. Conclusion: The analysis of pbNK cells fraction and their cytolytic activity can be valuable diagnostic markers for RSA. We are going to planning the large scaled studies which include the data of obstetric outcomes in subsequent pregnancies to clarify our results of this study.

The Effects of Storage of Human Saliva on DNA Isolation and Stability (인체타액의 보관이 DNA 분리와 안정도에 미치는 영향)

  • Kim, Yong-Woo;Kim, Young-Ku
    • Journal of Oral Medicine and Pain
    • /
    • v.31 no.1
    • /
    • pp.1-16
    • /
    • 2006
  • The most important progress in diagnostic sciences is the increased sensitivity and specificity in diagnostic procedures due to the development of micromethodologies and increasing availability of immunological and molecular biological reagents. The technological advances led to consider the diagnostic use of saliva for an array of analytes and DNA source. The purpose of the present study was to compare DNA from saliva with those from blood and buccal swab, to evaluate diagnostic and forensic application of saliva, to investigate the changes of genomic DNA in saliva according to the storage temperature and period of saliva samples, and to evaluate the integrity of the DNA from saliva stored under various storage conditions by PCR analysis. Peripheral venous blood, unstimulated whole saliva, stimulated whole saliva, and buccal swab were obtained from healthy 10 subjects (mean age: $29.9{\pm}9.8$ years) and genomic DNA was extracted using commercial kit. For the study of effects of various storage conditions on genomic DNA from saliva, stimulated whole saliva were obtained from healthy 20 subjects (mean age: $32.3{\pm}6.6$ years). After making aliquots from fresh saliva, they were stored at room temperature, $4^{\circ}C$, $-20^{\circ}C$, and $-70^{\circ}C$. Saliva samples after lyophilization and dry-out procedure were stored at room temperature. After 1, 3, and 5 months, the same experiment was performed to investigate the changes in genomic DNA in saliva samples. In case of saliva aliquots stored at room temperature and dry-out samples, the results in 2 weeks were also included. Integrity of DNA from saliva stored under various storage conditions was also evaluated by PCR amplification analysis of $\beta$-globin gene fragments (989-bp). The results were as follows: 1. Concentration of genomic DNA extracted from saliva was lower than that from blood (p<0.05), but there were no significant differences among various types of saliva samples. Purities of genomic DNA extracted from stimulated whole saliva and lyophilized one were significantly higher than that from blood (p<0.05). Purity of genomic DNA extracted from buccal swab was lower than those from various types of saliva samples (p<0.05). 2. Concentration of genomic DNA from saliva stored at room temperature showed gradual reduction after 1 month, and decreased significantly in 3 and 5 months (p<0.05, p<0.01, respectively). Purities of DNA from saliva stored for 3 and 5 months showed significant differences with those of fresh saliva and stored saliva for 1 month (p<0.05). 3. In the case of saliva stored at $4^{\circ}C$ and $-20^{\circ}C$, there were no significant changes of concentration of genomic DNA in 3 months. Concentration of DNA decreased significantly in 5 months (p<0.05). 4. There were no significant differences of concentration of genomic DNA from saliva stored at $-70^{\circ}C$ and from lyophilized one according to storage period. Concentration of DNA showed decreasing tendency in 5 months. 5. Concentration of genomic DNA immediately extracted from saliva dried on Petri dish were 60% compared with that of fresh saliva. Concentration of DNA from saliva stored at room temperature after dry-out showed rapid reduction within 2 weeks (p<0.05). 6. Amplification of $\beta$-globin gene using PCR was successful in all lyophilized saliva stored for 5 months. At the time of 1 month, $\beta$-globin gene was successfully amplified in all saliva samples stored at $-20^{\circ}C$ and $-70^{\circ}C$, and in some saliva samples stored at $4^{\circ}C$. $\beta$-globin gene was failed to amplify in saliva stored at room temperature and dry-out saliva.

Clinical Analysis of Influenza in Children and Rapid Antigen Detection Test on First Half of the Year 2004 in Busan (2004 상반기 부산 지역에서 유행한 인플루엔자의 임상 역학적 분석 및 인플루엔자 진단에 있어서의 신속 항원 검사법)

  • Choi, So Young;Lee, Na Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Pediatric Infection and Vaccine
    • /
    • v.11 no.2
    • /
    • pp.158-169
    • /
    • 2004
  • Purpose : Although influenza is one of the most important cause of acute respiratory tract infections in children, virus isolation is not popular and there are only a few clinical studies on influenza and diagnostic methods. We evaluated the epidemiological and clinical features of influenza in children and rapid antigen detection test(QuickVue influenza test) on fist half of the year 2004 in Busan. Methods : From January 2004 to June 2004, throat swab and nasal secretion were obtained and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : Influenza viruses were isolated in 79(17.2%) out of 621 patients examined. Influenza virus was isolated mainly from March to April 2004. The ratio of male and female with influenza virus infection was 1.2 : 1 with median age of 4 years 6month. The most common clinical diagnosis of influenza virus infection was bronchitis. There was no difference between influenza A and B infection in clinical diagnosis and symptoms. All patients recovered without severe complication. The sensitivity obtained for rapid antigen detection test (QuickVue influenza test) was 93.6% and the specificity was 80.2%, the positive predictive value 40.8%, the negative predictive value 98.8%. Conclusion : With rapid antigen detection test, it is possible early detection of influenza in children. reduction in use of antimicrobial agent and early use of antiviral agent.

  • PDF

Differential Diagnosis By Analysis of Pleural Effusion (흉수분석에 의한 질병의 감별진단)

  • Ko, Won-Ki;Lee, Jun-Gu;Jung, Jae-Ho;Park, Mu-Suk;Jeong, Nak-Yeong;Kim, Young-Sam;Yang, Dong-Gyoo;Yoo, Nae-Choon;Ahn, Chul-Min;Kim, Sung-Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.51 no.6
    • /
    • pp.559-569
    • /
    • 2001
  • Background : Pleural effusion is one of the most common clinical manifestations associated with a variety of pulmonary diseases such as malignancy, tuberculosis, and pneumonia. However, there are no useful laboratory tests to determine the specific cause of pleural effusion. Therefore, an attempt was made to analyze the various types of pleural effusion and search for useful laboratory tests for pleural effusion in order to differentiate between the diseases, especially between a malignant pleural effusion and a non-malignant pleural effusion. Methods : 93 patients with a pleural effusion, who visited the Severance hospital from January 1998 to August 1999, were enrolled in this study. Ultrasound-guided thoracentesis was done and a confirmational diagnosis was made by a gram stain, bacterial culture, Ziehl-Neelsen stain, a mycobacterial culture, a pleural biopsy and cytology. Results : The male to female ratio was 56 : 37 and the average age was $47.1{\pm}21.8$ years. There were 16 cases with a malignant effusion, 12 cases with a para-malignant effusion, 36 cases with tuberculosis, 22 cases with a para-pneumonic effusion, and 7 cases with transudate. The LDH2 fraction was significantly higher in the para-malignant effusion group compared to the para-pneumonic effusion group [$30.6{\pm}6.4%$ and $20.2{\pm}7.5%$, respectively (p<0.05)] and both the LDH1 and LDH2 fraction was significantly in the para-malignant effusion group compared to those with tuberculosis [$16.4{\pm}7.2%$ vs. $7.6{\pm}4.7%$, and $30.6{\pm}6.4%$ vs.$17.6{\pm}6.3%$, respectively (p<0.05)]. The pleural effusion/serum LDH4 fraction ratio was significantly lower in the malignant effusion group compared to those with tuberculosis [$1.5{\pm}0.8$ vs. $2.1{\pm}0.6$, respectively (p<0.05)]. The LDH4 fraction and the pleural effusion/serum LDH4 fraction ratio was significantly lower in the para-malignant effusion group compared to those with tuberculosis [$17.0{\pm}5.8%$ vs. $23.5{\pm}4.6%$ and $1.3{\pm}0.4$ vs. $2.1{\pm}0.6$, respectively (p<0.05)]. Conclusion : These results suggest that the LDH isoenzyme was the only useful biochemical test for a differential diagnosis of the various diseases. In particular, the most useful test was the pleural effusion/serum LDH4 fraction ratio to distinguish between a para-malignant effusion and a tuberculous effusion.

  • PDF

DC Resistivity method to image the underground structure beneath river or lake bottom (하저 지반특성 규명을 위한 전기비저항 탐사)

  • Kim Jung-Ho;Yi Myeong-Jong;Song Yoonho;Cho Seong-Jun;Lee Seong-Kon;Son Jeongsul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2002.09a
    • /
    • pp.139-162
    • /
    • 2002
  • Since weak zones or geological lineaments are likely to be eroded, weak zones may develop beneath rivers, and a careful evaluation of ground condition is important to construct structures passing through a river. Dc resistivity surveys, however, have seldomly applied to the investigation of water-covered area, possibly because of difficulties in data aquisition and interpretation. The data aquisition having high quality may be the most important factor, and is more difficult than that in land survey, due to the water layer overlying the underground structure to be imaged. Through the numerical modeling and the analysis of case histories, we studied the method of resistivity survey at the water-covered area, starting from the characteristics of measured data, via data acquisition method, to the interpretation method. We unfolded our discussion according to the installed locations of electrodes, ie., floating them on the water surface, and installing at the water bottom, since the methods of data acquisition and interpretation vary depending on the electrode location. Through this study, we could confirm that the dc resistivity method can provide the fairly reasonable subsurface images. It was also shown that installing electrodes at the water bottom can give the subsurface image with much higher resolution than floating them on the water surface. Since the data acquired at the water-covered area have much lower sensitivity to the underground structure than those at the land, and can be contaminated by the higher noise, such as streaming potential, it would be very important to select the acquisition method and electrode array being able to provide the higher signal-to-noise ratio data as well as the high resolving power. The method installing electrodes at the water bottom is suitable to the detailed survey because of much higher resolving power, whereas the method floating them, especially streamer dc resistivity survey, is to the reconnaissance survey owing of very high speed of field work.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.

Consideration on Shielding Effect Based on Apron Wearing During Low-dose I-131 Administration (저용량 I-131 투여시 Apron 착용여부에 따른 차폐효과에 대한 고찰)

  • Kim, Ilsu;Kim, Hosin;Ryu, Hyeonggi;Kang, Yeongjik;Park, Suyoung;Kim, Seungchan;Lee, Guiwon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.32-36
    • /
    • 2016
  • Purpose In nuclear medicine examination, $^{131}I$ is widely used in nuclear medicine examination such as diagnosis, treatment, and others of thyroid cancer and other diseases. $^{131}I$ conducts examination and treatment through emission of ${\gamma}$ ray and ${\beta}^-$ ray. Since $^{131}I$ (364 keV) contains more energy compared to $^{99m}Tc$ (140 keV) although it displays high integrated rate and enables quick discharge through kidney, the objective of this study lies in comparing the difference in exposure dose of $^{131}I$ before and after wearing apron when handling $^{131}I$ with focus on 3 elements of external exposure protection that are distance, time, and shield in order to reduce the exposure to technicians in comparison with $^{99m}Tc$ during the handling and administration process. When wearing apron (in general, Pb 0.5 mm), $^{99m}Tc$ presents shield of over 90% but shielding effect of $^{131}I$ is relatively low as it is of high energy and there may be even more exposure due to influence of scattered ray (secondary) and bremsstrahlung in case of high dose. However, there is no special report or guideline for low dose (74 MBq) high energy thus quantitative analysis on exposure dose of technicians will be conducted based on apron wearing during the handling of $^{131}I$. Materials and Methods With patients who visited Department of Nuclear Medicine of our hospital for low dose $^{131}I$ administration for thyroid cancer and diagnosis for 7 months from Jun 2014 to Dec 2014 as its subject, total 6 pieces of TLD was attached to interior and exterior of apron placed on thyroid, chest, and testicle from preparation to administration. Then, radiation exposure dose from $^{131}I$ examination to administration was measured. Total procedure time was set as within 5 min per person including 3 min of explanation, 1 min of distribution, and 1 min of administration. In regards to TLD location selection, chest at which exposure dose is generally measured and thyroid and testicle with high sensitivity were selected. For preparation, 74 MBq of $^{131}I$ shall be distributed with the use of $2m{\ell}$ syringe and then it shall be distributed after making it into dose of $2m{\ell}$ though dilution with normal saline. When distributing $^{131}I$ and administering it to the patient, $100m{\ell}$ of water shall be put into a cup, distributed $^{131}I$ shall be diluted, and then oral administration to patients shall be conducted with the distance of 1m from the patient. The process of withdrawing $2m{\ell}$ syringe and cup used for oral administration was conducted while wearing apron and TLD. Apron and TLD were stored at storage room without influence of radiation exposure and the exposure dose was measured with request to Seoul Radiology Services. Results With the result of monthly accumulated exposure dose of TLD worn inside and outside of apron placed on thyroid, chest, and testicle during low dose $^{131}I$ examination during the research period divided by number of people, statistics processing was conducted with Wilcoxon Signed Rank Test using SPSS Version. 12.0K. As a result, it was revealed that there was no significant difference since all of thyroid (p = 0.345), chest (p = 0.686), and testicle (p = 0.715) were presented to be p > 0.05. Also, when converting the change in total exposure dose during research period into percentage, it was revealed to be -23.5%, -8.3%, and 19.0% for thyroid, chest, and testicle respectively. Conclusion As a result of conducting Wilcoxon Signed Rank Test, it was revealed that there is no statistically significant difference (p > 0.05). Also, in case of calculating shielding rate with accumulate exposure dose during 7 months, it was revealed that there is irregular change in exposure dose for inside and outside of apron. Although the degree of change seems to be high when it is expressed in percentage, it cannot be considered a big change since the unit of accumulated exposure dose is in decimal points. Therefore, regardless of wearing apron during high energy low dose $^{131}I$ administration, placing certain distance and terminating the administration as soon as possible would be of great assistance in reducing the exposure dose. Although this study restricted $^{131}I$ administration time to be within 5 min per person and distance for oral administration to be 1m, there was a shortcoming to acquire accurate result as there was insufficient number of N for statistics and it could be processed only through non-parametric method. Also, exposure dose per person during lose dose $^{131}I$ administration was measured with accumulated exposure dose using TLD rather than through direct-reading exposure dose thus more accurate result could be acquired when measurement is conducted using electronic dosimeter and pocket dosimeter.

  • PDF

Home Economics teachers' concern on creativity and personality education in Home Economics classes: Based on the concerns based adoption model(CBAM) (가정과 교사의 창의.인성 교육에 대한 관심과 실행에 대한 인식 - CBAM 모형에 기초하여-)

  • Lee, In-Sook;Park, Mi-Jeong;Chae, Jung-Hyun
    • Journal of Korean Home Economics Education Association
    • /
    • v.24 no.2
    • /
    • pp.117-134
    • /
    • 2012
  • The purpose of this study was to identify the stage of concern, the level of use, and the innovation configuration of Home Economics teachers regarding creativity and personality education in Home Economics(HE) classes. The survey questionnaires were sent through mails and e-mails to middle-school HE teachers in the whole country selected by systematic sampling and convenience sampling. Questionnaires of the stages of concern and the levels of use developed by Hall(1987) were used in this study. 187 data were used for the final analysis by using SPSS/window(12.0) program. The results of the study were as following: First, for the stage of concerns of HE teachers on creativity and personality education, the information stage of concerns(85.51) was the one with the highest response rate and the next high in the following order: the management stage of concerns(81.88), the awareness stage of concerns(82.15), the refocusing stage of concerns(68.80), the collaboration stage of concerns(61.97), and the consequence stage of concerns(59.76). Second, the levels of use of HE teachers on creativity and personality education was highest with the mechanical levels(level 3; 21.4%) and the next high in the following order: the orientation levels of use(level 1; 20.9%), the refinement levels(level 5; 17.1%), the non-use levels(level 0; 15.0%), the preparation levels(level 2; 10.2%), the integration levels(level 6; 5.9%), the renewal levels(level 7; 4.8%), the routine levels(level 4; 4.8%). Third, for the innovation configuration of HE teachers on creativity and personality education, more than half of the HE teachers(56.1%) mainly focused on personality education in their HE classes; 31.0% of the HE teachers performed both creativity and personality education; a small number of teachers(6.4%) focused on creativity education; the same number of teachers(6.4%) responded that they do not focus on neither of the two. Examining the level and type of performance HE teachers applied, the average score on the performance of creativity and personality education was 3.76 out of 5.00 and the mean of creativity component was 3.59 and of personality component was 3.94, higher than standard. For the creativity education, openness/sensitivity(3.97) education was performed most and the next most in the following order: problem-solving skill(3.79), curiosity/interest(3.73), critical thinking(3.63), problem-finding skill(3.61), originality(3.57), analogy(3.47), fluency/adaptability(3.46), precision(3.46), imagination(3.37), and focus/sympathy(3.37). For the personality education, the following components were performed in order from most to least: power of execution(4.07), cooperation/consideration/just(4.06), self-management skill(4.04), civic consciousness(4.04), career development ability(4.03), environment adaptability(3.95), responsibility/ownership(3.94), decision making(3.89), trust/honesty/promise(3.88), autonomy(3.86), and global competency(3.55). Regarding what makes performing creativity and personality education difficult, most HE teachers(64.71%) chose the lack of instructional materials and 40.11% of participants chose the lack of seminar and workshop opportunity. 38.5% chose the difficulty of developing an evaluation criteria or an evaluation tool while 25.67% responded that they do not know any means of performing creativity and personality education. Regarding the better way to support for creativity and personality education, the HE teachers chose in order from most to least: 'expansion of hands-on activities for students related to education on creativity and personality'(4.34), 'development of HE classroom culture putting emphasis on creativity and personality'(4.29), 'a proper curriculum on creativity and personality education that goes along with students' developmental stages'(4.27), 'securing enough human resource and number of professors who will conduct creativity and personality education'(4.21), 'establishment of the concept and value of the education on creativity and personality'(4.09), and 'educational promotion on creativity and personality education supported by local communities and companies'(3.94).

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF