• Title/Summary/Keyword: Sensitivity Equation

Search Result 481, Processing Time 0.03 seconds

Simulation of Two-Phase Fluid Flow in a Single Fracture Surrounding an Underground LPG Storage Cavern: II. Verification of Numerical Model and Field Application (지하 LPG 저아공동에 인접한 단일절리에서의 이상유체거동해석: II. 수치모형의 검증 및 적용)

  • Han, Il-Yeong;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • In order to verify the numerical model, which was developed to simulate the behavior of the two-phase fluid flow in a single fracture, the characteristic equation of relative permeability was incorporated into the developed numerical model, and the computed results were compared with the experimental results of the model test. As results of the sensitivity analysis on the roughness and the aperture size of fracture, the gas velocity was inversely proportional to the fracture roughness, and not proportional to the square of aperture size which is usually observed in single phase flow in a single fracture. The numerical model was applied to the underground LPG storage terminal in order to check the field applicability. The simultaneous flow of water and gas in accordance with the operation pressures in a single fracture near cavern was simulated by the model. It was shown that the leaked gas was able to be controlled in a single fracture neither by the pressure of operation nor by that of groundwater in case the fracture became smoother in roughness and smaller in aperture size.

  • PDF

Experimental Verification of Sag Sensitivities using Catenary Model for PPWS Configuration Control in a Suspension Bridge (모형 현수선을 이용한 현수교 PPWS 형상관리를 위한 새그민감도의 실험적 검증)

  • Jeong, Woon;Seo, Ju Won;Lee, Sung Hyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.711-721
    • /
    • 2014
  • PPWS, a large number of which a main cable of a suspension bridge consists of, must be precisely erected at a target location under construction considering the differences among design conditions. The absolute sag is measured for several PPWSs, which are reference strands and the relative sag is surveyed from them to other PPWSs, which are divided into several groups. And the adjustment of PPWS length is performed to erect it at target configuration. When PPWS is being under erection in a real bridge site, the procedures are as follows; evaluate sag sensitivities according to sag variation factors, calculate an adjustment length of PPWS corresponding to them and adjust a sag of PPWS by controlling the calculated amount of PPWS length. In this study, the differential-related equations of sag sensitivity were proposed for support movement of PPWS. Before site demonstration study of a series of them, we established a catenary model system and accomplished verification tests of them. From test results, the validation of them was done.

Standardization of an enzyme-linked immunosorbent assay for detection of antibody to avian reticuloendotheliosis virus (세망내피증 바이러스 항체검출을 위한 ELISA 표준화)

  • Sung, Haan Woo;Lee, Su Jeong
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.4
    • /
    • pp.569-574
    • /
    • 2005
  • Enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to reticuloendotheliosis virus (REV) at single serum dilution was standardized. REV HI, one of the Korean field isolates, was inoculated into chicken embryo fibroblast (CEF) cells and was harvested from the culture fluids and cells after 10 to 12 days. Viruses were purified by centrifugation at the $107,000{\times}g$ for 12 hours on 20, 30, 45% (W/V) sucrose gradient. Virus specific fraction was collected and used as ELISA antigen. To standardize ELISA, the optimal concentration of coating antigen ($1{\mu}g/well$) and conjugate (1/1000) was determined by corrected OD (OD value of positive serum-OD value of negative serum) and P/N ratio (OD value of positive serum/OD value of negative serum). To calculate ELISA titer by measuring absorbance at 1/400 single serum dilution, serum titrations were carried out for various sample sera together with standard positive and negative sera. The observed titers of serum samples were plotted against sample/positive (s/p) ratios at 1/400 serum dilution. From the above data, the ELISA titers could be calculated by the equation of $log_{10}$ ELISA titer = 2.2763 ($log_{10}$ s/p) + 3.482 (r = 0.93). For evaluating the sensitivity, the standardized method were compared with conventional agar gel immunodiffusion (AGID) test method using serum samples collected from REV infected field chicken flocks. Fifty seven of 60 samples (95%) were positive for REV by ELISA, whereas only 11 (18.3%) samples were positive by AGID test. This results suggested that the ELISA tests developed in this study could be used for detection of antibodies to REV with high sensitivity.

Conjugate Gradient Least-Squares Algorithm for Three-Dimensional Magnetotelluric Inversion (3차원 MT 역산에서 CG 법의 효율적 적용)

  • Kim, Hee-Joon;Han, Nu-Ree;Choi, Ji-Hyang;Nam, Myung-Jin;Song, Yoon-Ho;Suh, Jung-Hee
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.2
    • /
    • pp.147-153
    • /
    • 2007
  • The conjugate gradient (CG) method is one of the most efficient algorithms for solving a linear system of equations. In addition to being used as a linear equation solver, it can be applied to a least-squares problem. When the CG method is applied to large-scale three-dimensional inversion of magnetotelluric data, two approaches have been pursued; one is the linear CG inversion in which each step of the Gauss-Newton iteration is incompletely solved using a truncated CG technique, and the other is referred to as the nonlinear CG inversion in which CG is directly applied to the minimization of objective functional for a nonlinear inverse problem. In each procedure we only need to compute the effect of the sensitivity matrix or its transpose multiplying an arbitrary vector, significantly reducing the computational requirements needed to do large-scale inversion.

Applicability evaluation of velocity profile method by V-ADCP measuring real-time river water use (실시간 하천수사용량 계측을 위한 V-ADCP 유속분포법의 적용성 평가)

  • Song, Jae Hyun;Park, Moon Hyung;Cha, Jun-Ho;Kim, Chi Young
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.83-96
    • /
    • 2019
  • In order to properly manage the river water use, it is necessary to collect reliable data of river water use. However, It is not easy to get credible river water use data in Korea because there are some difficultites in reporting and measuring river water use data. Thus, Han River Flood Control Office has installed and operated measuring facility using V-ADCP on the EOUBO intake open channel in the Gosan-Bongdong station section of the Mankyung river, where the use of agricultural water is large. In this study, the applicability of the V-ADCP velocity profile method was evaluated for real-time river water use. For this reason, the parameter sensitivity of Chiu's 2D velocity distribution equation was analyzed and the optimal parameters based on actual discharge data were calculated. In addition, the characteristics of the velocity profile method were analyzed by comparative evaluation of the rating curve method and the index velocity method.

Study on the Steam Line Break Accident for Kori Unit-1 (고리 1호기에 대한 증기배관 파열사고 연구)

  • Tae Woon Kim;Jung In Choi;Un Chul Lee;Ki In Han
    • Nuclear Engineering and Technology
    • /
    • v.14 no.4
    • /
    • pp.186-195
    • /
    • 1982
  • The steam line break accident for Kori Unit 1 is analyzed by a code SYSRAN which calculates nuclear power and heat flux using the point kinetics equation and the lumped-parameter model and calculates system transient using the mass and energy balance equation with the assumption of uniform reactor coolant system pressure. The 1.4 f $t^2$ steam line break accident is analyzed at EOL (End of Life), hot shutdown condition in which case the accident would be most severe. The steam discharge rate is assumed to follow the Moody critical flow model. The results reveal the peak heat flux of 38% of nominal full power value at 60 second after the accident initiates, which is higher than the FSAR result of 26%. Trends for the transient are in good agreement with FSAR results. A sensitivity study shows that this accident is most sensitive to the moderator density coefficient and the lower plenum mixing factor. The DNBR calculation under the assumption of $F_{{\Delta}H}$=3.66, which is used in the FSAR with all the control and the shutdown assemblies inserted except one B bank assembly and of Fz=1.55 shows that minimum DNBR reaches 1.62 at 60 second, indicating that the fuel failure is not anticipated to occur. The point kinetics equation, the lumped-parameter model and the system transient model which uses the mass and energy balance equation are verified to be effective to follow the system transient phenomena of the nuclear power plants.lear power plants.

  • PDF

Rate-Product Correlations for the Solvolysis of 5-Nitro-2-Furoyl Chloride

  • Choi, Ho-June;Koh, Han-Joong;Ali, Dildar;Yang, Ki-Yull;Koo, In-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3293-3297
    • /
    • 2012
  • The solvolysis rate constants of 5-nitro-2-furoyl chloride (5-$NO_2(C_4H_2O)$-2-COCl, 1) in 27 different solvents are well correlated with the extended Grunwald-Winstein equation, using the $N_T$ solvent nucleophilicity scale and YCl solvent ionizing scale, with sensitivity values of $1.20{\pm}0.05$ and $0.37{\pm}0.02$ for l and m, respectively. The activation enthalpies (${\Delta}H^{\neq}$) were 5.63 to $13.0kcal{\cdot}mol^{-1}$ and the activation entropies (${\Delta}S^{\neq}$) were -25.9 to $-43.4cal{\cdot}mol^{-1}{\cdot}K^{-1}$, which is consistent with the proposed bimolecular reaction mechanism. The solvent kinetic isotope effect (SKIE, $k_{MeOH}/k_{MeOD}$) of 2.65 was also in accord with the $S_N2$ mechanism and was possibly assisted using a general-base catalysis. The product selectivity (S) for solvolysis of 1 in alcohol/water mixtures was 1.2 to 11, which is also consistent with the proposed bimolecular reaction mechanism.

Reliability Analysis of Gas Turbine Engine Blades (가스터빈 블레이드의 신뢰성 해석)

  • Lee, Kwang-Ju;Rhim, Sung-Han;Hwang, Jong-Wook;Jung, Yong-Wun;Yang, Gyae-Byung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1186-1192
    • /
    • 2008
  • The reliability of gas turbine engine blades was studied. Yield strength, Young’s modulus, engine speed and gas temperature were considered as statistically independent random variables. The failure probability was calculated using five different methods. Advanced Mean Value Method was the most efficient without significant loss in accuracy. When random variables were assumed to have normal, lognormal and Weibull distributions with the same means and standard deviations, the CDF of limit state equation did not change significantly with the distribution functions of random variables. The normalized sensitivity of failure probability with respect to standard deviations of random variables was the largest with gas temperature. The effect of means and standard deviations of random variables was studied. The increase in the mean of gas temperature and the standard deviation of engine speed increased the failure probability the most significantly.

An Eulerian-Lagrangian Hybrid Numerical Method for the Longitudinal Dispersion Equation (Eulerian-Lagrangian 혼합모형에 의한 종확산 방정식의 수치해법)

  • 전경수;이길성
    • Water for future
    • /
    • v.26 no.3
    • /
    • pp.137-148
    • /
    • 1993
  • A hybrid finite difference method for the longitudinal dispersion equation was developed. The method is based on combining the Holly-Preissmann scheme with the fifth-degree Hermite interpolating polynomial and the generalized Crank-Nicholson scheme. Longitudinal dispersion of an instantaneously-loaded pollutant source was simulated by the model and other characteristics-based numerical methods. Computational results were compared with the exact solution. The present method was free from wiggles regardless of the Courant number, and exactly reproduced the location of the peak concentration. Overall accuracy of the computation increased for smaller value of the weighting factor, $\theta$ of the model. Larger values of $\theta$ overestimated the peak concentration. Smaller Courant number gave better accuracy, in general, but the sensitivity was very low, especially when the value of $\theta$ was small. From comparisons with the hybrid method using the third-degree interpolating polynomial and with split-operator methods, the present method showed the best performance in reproducing the exact solution as the advection becomes more dominant.

  • PDF

Studies on avian infectious bronchitis: II. Standardization of an indirect enzyme-linked immunosorbent assay (ELISA) for antibody measurement (닭 전염성 기관지염에 관한 연구: II. 간접 enzyme-linked immunosorbent assay(ELISA)에 의한 항체가 측정)

  • Chang, Chong-ho;Kim, Sun-joong
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.4
    • /
    • pp.503-515
    • /
    • 1989
  • Critical parameters affecting sensitivity and specificity of an enzyme-linked immunosorbent assay(ELISA) for detection of antibodies to avian infections bronchitis virus(IBV) were standardized. By adopting the optimized conditions an equation calculating ELISA antibody titers from the observations at single serum dilution was formulated. The purified antigen of IBV Mass-41 strain was dispensed into polystyrene microplate wells at a concentration of 300ng per well($100{\mu}l$) and the plates were coated by completey drying at $37^{\circ}C$. Diluted chicken serum and horseradish peroxidase conjugated goat anti-chicken IgG were added in order in $100{\mu}l$ volumes per well and allowed to react for 30 minutes each at room temperature. Just before use and after each reaction the plates were washed three times with distilled water. Finally o-phenylenediamine solution was added as an enzyme substrate. After incubation for another 15 minutes at room temperature absorbances were read at 492nm. Hyperimmune serum against Mass-41 strain was used as internal reference positive(IRP) serum. After repeated titration of IRP and negative serum, a constant titer of IRP was determined. Serum titrations were carried out for various sample sera together with IRP and negative sera and the observed titers of sample sera were corrected by reflecting the ratio between observed and constant titers of IRP serum. These corrected titers of the sample sera were plotted against sample/positive(S/P) OD ratios. All the OD's measured in the serum titrations were also corrected by substracting negative serum OD. The following equation was formulated from the above data; $Log_{10}$ ELISA titer=$5.568({\log}_{10}S/P)+4.161$ Thus it was possible to calculate ELISA titer by measuring absorbance at 1/400 single serum dilution. Titer measured by cross ELISA tests employing Mass-41 strain and three local IBV isolates were similar. These results suggest that the ELISA tests standardized in this study can be used for evaluating not only vaccinal immunity but also for infection status against fields IBV's.

  • PDF