• Title/Summary/Keyword: Sensitive Equipment

Search Result 246, Processing Time 0.036 seconds

Development of Valve Balance Test Equipment for Power Steering Gear (파워 스티어링 기어의 밸브 밸런스 테스트 장비 개발)

  • Go, S.J.;Park, M.K.;Won, T.H.;Kim, H.S.;Kim, K.H.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.1
    • /
    • pp.65-71
    • /
    • 2011
  • Steering gear is the part of an automobile that change circular movement of steering wheel to lateral movement of rack to change driving direction. This can be classified with manual and power steering gear. Manual steering gear is operated only with human power while power steering gear use oil pressure support. These days power steering gear is more common to almost of the car. Recently a korean company manufactures a speed sensitive power steering which provide variable steering feel depend on the speed of car. The Broens company of Australia produces and exports the test equipments for the manufacture of power steering valves and assemblies to major vehicle manufactures. Some korean companies imported the test equipments from Australia, thus increasing the cost. The purpose of this study is development of the valve balance test equipment to measure the valve torque of the power steering gear. This study designed and manufactured the valve balance test equipment to take hold of the power steering valve using CAE analysis. In order to evaluate the performance of the developed valve balance test equipment, the R&R tests have been conducted.

Development of Three-Phase Line-Interactive Dynamic Voltage Restorer with Hybrid Detection Method (Hybrid 검출방식을 적용한 삼상 선로 응동형 DVR(Dynamic Voltage Restorer))

  • Jeong, Jong-Kyou;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.901_902
    • /
    • 2009
  • This paper describes the development of a three-phase Line-Interactive DVR(Dynamic Voltage Restorer), which is applied to Hybrid detection method and super-capacitor. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental will be work with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF

Development of Watt-Hour Meter Exchange Equipment without Outage (전력량계 무정전 교체장치 개발에 관한 연구)

  • Jung, Tae-Hoon;Cho, Sung-Min;Shin, Hee-Sang;Lee, Hee-Tae;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.99-103
    • /
    • 2009
  • This paper presents equipment that can exchange watt-hour meters without outage for customers, It is simpler than other methods to avoid outage during exchange. Furthermore, it has protective function to ensure customer's facility from engineer mistake. Because of good point mentioned above, it can improve efficiency and safety. Adopting developed equipment can ensure continuous electric power supply to customers.

Vibration Analysis of Network Communication Equipment (네트워크 통신장비의 진동 해석)

  • Lee Jae-Hwan;Kim Jin-Sup;Kim Young-Jung
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.467-472
    • /
    • 2006
  • The purpose of this paper is to check the structural safety of the network equipments by performing the static and dynamic finite element analysis. The stress and displacement of structures under static loading condition are evaluated to check whether satisfying the design requirement conditions. Since the computed natural frequencies are similar to the results of experiment. the model could be used for the response spectrum analysis where experimental acceleration value at each frequency are used as seismic input excitation. It is shown that the analysis results are a little bit larger than that of the experimental values. Also sensitivity analysis and optimization for the natural frequency are performed and it is found that the first natural frequency is very sensitive to the stiffness of the equipment.

  • PDF

The Optimum Design of Green Water Protector for FPSO (FPSO - Green Water Protector 구조 최적 설계)

  • Bae, Myung-Hyun;Kim, Sung-Jun;Moon, Jung-Yang
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2007.09a
    • /
    • pp.94-98
    • /
    • 2007
  • The latest development of the submarine oil field and the deep-sea explorer, FPSO is commonly proposed and used for offshore oil production. And because the fundamental requirement of FPSOs to remain moored at their position, they are unable to avoid severe weather and environment. FPSO normally operates head to the weather, and sensitive equipment located the exposed area will be influenced by green water damages, the damages may occur to both onboard equipment and topside structures with resulting risk to personnel. In this paper, the main focus considers the physical structures of green water protector in order to preserve topside structures, equipment and personnel from green water.

  • PDF

Development of High-Performance Single-Phase Line-Interactive Dynamic Voltage Restorer (고성능 단상 선로응동형 DVR(Dynamic Voltage Restorer))

  • Bae, Byung-Yeol;Lee, Dong-Geun;Kwak, No-Hong;Park, Sang-Ho;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1947-1954
    • /
    • 2007
  • This paper describes the development of a high-performance single-phase line-interactive Dynamic voltage Restorer, which is composed of an H-bridge inverter and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable duration of voltage interruption is 1.5 seconds. It can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

Diagnosis of Plasma Equipment using Neural Network and Impedance Match Monitoring

  • Byungwhan Kim
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.120-124
    • /
    • 2002
  • A new methodology is presented to diagnose faults in equipment plasma. This is accomplished by using neural networks as a pattern recognizer of radio frequency (rf) impedance match data. Using a match monitor system, the match data were collected. The monitor system consisted mainly of a multifunction board and a signal flow diagram coded by Visual Designer. Plasma anomaly was effectively represented by electrical match positions. Twenty sets of fault-symptom patterns were experimentally simulated with variations in process factors, which include rf source power, pressure, Ar, and $O_$2 flow rates. As an input to neural networks, two means and standard deviations of positions were used as well as a reflected power. Diagnostic accuracy was measured as a function of training factors, which include the number of hidden neurons, the magnitude of initial weights, and two gradients of neuron activation functions. The accuracy was the most sensitive to the number of hidden neurons. Interaction effects on the accuracy were also examined by performing a 2$^$4 full factorial experiment. The experiments were performed on multipole inductively coupled plasma equipment.

  • PDF

Development of Single-Phase DVR(Dynamic Voltage Restorer) Composed of H-Bridge Inverter and SuperCapacitor (H-브리지 인버터와 수퍼커패시터로 구성된 단상 DVR(Dynamic Voltage Restorer)의 개발)

  • Lee, Dong-Geun;Lee, Doo-Young;Yang, Seung-Chul;Bae, Byung-Yeol;Han, Byung-Moon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.160-161
    • /
    • 2007
  • This paper describes the development of a single-phase DVR(Dynamic voltage Restorer), which is composed of H-bridge inverter and super-capacitors. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software, and experimental works with 3kVA prototype. The developed system can compensates the input voltage sag and interruption within 2ms, in which the maximum allowable duration of voltage interruption is 1.5 seconds. It can be effectively used to compensate the voltage interruption in the sensitive load, such as computer, communication equipment, automation equipment, and medical equipment. The developed system has a simple structure to be easily implemented with commercially available components and to be highly reliable in operation.

  • PDF

실험적 방법을 이용한 TFT-LCD 정밀 검사 장비의 진동 허용 규제치 평가 및 진동 저감 대책

  • Lee Hong-Gi;Park Sang-Gon;Jeon Jong-Gyun;Son Seong-Wan
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.09a
    • /
    • pp.49-54
    • /
    • 2005
  • In the case of a sensitive equipment, it require a vibration free environment to provide its proper function. Especially, lithography and inspection device, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved Giga Class semi conductor wafers. The aim of this study is to evaluate the allowable vibration response of a precision inspect ion equipment, which has some trouble in field, by using experimental measurement data and to proposal a proper ant i-vibration method.

  • PDF

Analysis of Construction Cost Fluctuation Trends and Features on Apartment Housing

  • Park, Wonyoung;Kang, Tai-Kyung;Baek, Seung-Ho;Lee, Yoo-Sub
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.6
    • /
    • pp.624-635
    • /
    • 2012
  • Construction projects, including housing, are carried out over long periods of time. According to changes to the construction period, the cost of input materials and wages also changes. Therefore appropriate management is important in order to minimize cost risks caused by fluctuations in prices. In Korea, housing units are usually sold in lots prior to construction completion. Therefore, careful management of input elements such as materials and equipment that are sensitive to price fluctuations is very important. This study deals with how the price fluctuation of materials, labor, and equipment influences the change of housing cost and seeks a way for cost management through identifying key resources sensitive to price fluctuation. As a result, a change to the housing cost index multiplies depending on cost changes of materials and labor together. Labor costs are a major factor on the housing cost index. In addition, certain types of materials and labor input to housing construction greatly influence price fluctuations. Thus, it is found that managing those main cost factors is the key for effective cost management.