• Title/Summary/Keyword: Sensing and Application

Search Result 1,526, Processing Time 0.034 seconds

A High-precision AC Power Control System for Variable Loads Application (가변부하 적용을 위한 고정밀 교류전원 제어시스템)

  • Han, Wun-Dong;Shon, Jin-Geun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.7 no.3
    • /
    • pp.74-81
    • /
    • 2008
  • The control system of high-precision AC power is important in traffic management lighting and beaconing of aerodromes, etc. To control AC power supply in these load characteristics, inverter systems of AC/DC/AC conversion are widely used in high-precision current control. Therefore, in this paper, a inverter system of constant current regulation using improved measuring technique of feedback current is proposed. Proposed measuring techniques improve response and precision in that it use moving average method of instantaneous RMS for measuring current sensing. Results of the computer simulation and experiment prove the effects of proposed system.

  • PDF

A Study about the Application of Rogowski Coil on the LTCC (LTCC기판상에 구현한 로고스키코일의 적용에 관한 연구)

  • Kim, Eun-Sup;Son, Won-Keun;Moon, Hyung-Shin;Park, Sung-Hyun;Shin, Byung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.28-28
    • /
    • 2008
  • Generally speaking, Rogowskii coil for magnetic flux change detection according to electric current is used for digital addition watt-hour meter, because it is not saturated at electromagnetic that not Current Transformer working by magnetic material but non-magnetic material. In this paper, we described sensitive quality an electric current coil sensor followed by the principal of Rogowskii coil on the low dielectric loss LTCC, change different line width, gap, line length at sensing parts and extinction parts.

  • PDF

Application of Temperature Inversion by Using Spectral Radiation Intensities (파장별 복사강도를 사용한 온도 역계산의 적용)

  • Yang, Soo-Seok;Song, Tae-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.4
    • /
    • pp.533-542
    • /
    • 2000
  • Analytical experiments to determine the line-of-sight temperature distribution is conducted by using spectral radiation intensities. For this study, fourteen narrow bands of $25cm^{-1}$ interval in $CO_2\;4.3{\mu}m$ band ($2,050cm^{-1}$ to $2375cm^{-1}$) are selected. The applied system is a one-dimensional gas slab filled with 100% $CO_2$ gas at 1 atm. Two types of temperature profile are tested; parabolic and boundary layer types. Three kinds of radiation calculation are used in the iteration procedure for the temperature inversion; LBL(Line by Line), SNB(Statistical Narrow Band) and WNB(WSGGM. based Narrow Band) models. The LBL solution shows perfect agreement while some error of temperature prediction is caused by radiation modeling error when using SNB and WNB models. The inversion result shows that the WNB model may be used more accurately in spectral remote sensing techniques than the traditional SNB model.

AN APPROACH TO THE TRAINING OF A SUPPORT VECTOR MACHINE (SVM) CLASSIFIER USING SMALL MIXED PIXELS

  • Yu, Byeong-Hyeok;Chi, Kwang-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 2008.10a
    • /
    • pp.386-389
    • /
    • 2008
  • It is important that the training stage of a supervised classification is designed to provide the spectral information. On the design of the training stage of a classification typically calls for the use of a large sample of randomly selected pure pixels in order to characterize the classes. Such guidance is generally made without regard to the specific nature of the application in-hand, including the classifier to be used. An approach to the training of a support vector machine (SVM) classifier that is the opposite of that generally promoted for training set design is suggested. This approach uses a small sample of mixed spectral responses drawn from purposefully selected locations (geographical boundaries) in training. A sample of such data should, however, be easier and cheaper to acquire than that suggested by traditional approaches. In this research, we evaluated them against traditional approaches with high-resolution satellite data. The results proved that it can be used small mixed pixels to derive a classification with similar accuracy using a large number of pure pixels. The approach can also reduce substantial costs in training data acquisition because the sampling locations used are commonly easy to observe.

  • PDF

POTENTIAL OF MULTI-BAND SAR DATA FOR CLASSIFYING FOREST COVER TYPE

  • Shin, Jung-Il;Yoon, Jong-Suk;Kang, Sung-Jin;Lee, Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.258-261
    • /
    • 2007
  • Although there have been lack of studies using X-band SAR data particularly for forestry application as compared to C-, and L-band SAR data, it has a potential to distinguish tree species because most signals are backscattered on the top of canopy. This study aimed to compare signal characteristics of multi-band SAR data including X-band for classifying tree species. The data used for the study are SIR-C/X-SAR data (X-, C-, L-band) obtained on Oct. 3, 1994 over the forest area near Seoul, S. Korea. Thirty ground sample plots were collected per each tree species. Initial comparison of backscattering coefficients among three SAR bands shows that X-band data showed better separation of tree species than C- and L-band SAR data irrespective of polarization. The weak penetrating in canopy layer might be possible source of information for X-band data to be useful for the classification of forest species and cover type mapping.

  • PDF

Detection of the mechanical resonance of a micromechanical cantilever using dynamic flexural measurement technique and its mass sensing application

  • Kim, Hak-Seong;Yun, Ho-Yeol;Jeong, Un-Seok;Yu, Na-Ri;Park, Jeong-Ho;Lee, Sang-Uk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.447-447
    • /
    • 2011
  • We studied to detect the mass variation using micro mechanical resonator. For measuring the resonance frequency of the micro mechanical system, optical method using laser interference is selected. A simple resonator is prepared by attaching an AFM cantilever on the piezo stack. The piezo stack makes a the cantilever vibrated with its resonance frequency. To change the mass of the resonator, gold was evaporated on the cantilever. We measured how much resonance frequency was changed according to the amount of gold attached on cantilever. This resonator is able to perform the role of a mass sensor and has a resolution of the order of micrograms. The fabrication of the resonator and measurement setup for detecting the mechanical resonance will be introduced in this presentation.

  • PDF

Humidity Calibration for a Pressure Gauge Using a Temperature-Stable Quartz Oscillator

  • Suzuki, Atsushi
    • Applied Science and Convergence Technology
    • /
    • v.25 no.6
    • /
    • pp.124-127
    • /
    • 2016
  • Humidity calibration for a temperature-stable quartz oscillator (TSQO) was investigated to exclude the influences of relative humidity on the TSQO output in order to use the corresponding devices outdoors. The TSQO output is a voltage that is inversely proportional to the electric impedance of the quartz oscillator, which depends on the viscosity and density of the measured gas. The TSQO output was humidity calibrated using its humidity dependence, which was obtained by varying the relative humidity (RH) from 0 to 100 RH% while other conditions were kept constant. The humidity dependencies of the TSQO output were fit by a linear function. Subtracting the change in the TSQO output induced by the change in humidity, calculated with the function from the experimentally measured TSQO output for a range of 0-100RH%, eliminated the influence of humidity on the TSQO output. The humidity calibration succeeded in reducing the fluctuations of the TSQO output from 0.4-3% to 0.1-0.3% of the average values for a range of 0-100RH%, at constant temperatures. The necessary stability of the TSQO output for application in hydrogen sensors was below one-third of the change observed for a hydrogen leakage of 1 vol.% hydrogen concentration, corresponding to 0.33% of the change in each background. Therefore, the results in this study indicate that the present humidity calibration effectively suppresses the influence of humidity, for the TSQO output for use as an outdoor hydrogen sensor.

Video Strip Mapping (VSM) and Patch Dynamics Analysis for Revegetation Monitoring of a Pipeline Route (송유관선로의 식생복원 감시를 위한 비디오선형지도화 및 patch dynamics분석)

  • Jung-Sup Um
    • Journal of the Korean Geographical Society
    • /
    • v.33 no.3
    • /
    • pp.435-446
    • /
    • 1998
  • This Paper reports that a new remote sensing techlique focused on a narrow and long strip target (e.g. 15m wide and 100km long) has been specifically developed for pipeline ROW (Right-Of-Way) recovery monitoring. With video it was possible to isolate the maior vegetation communities of the narrow pipeline ROW with acceptable spatial precision by visual or quantitative methods. It was particuarly useful when used to assess a variety of spatial patch dynamics for ROW recovery through digital change-detection techniques in a GIS environment. The main conclusion of this paper is that VSM is a realistic operational technique for a pipeline ROW application. The results also indicate that VSM could be extensively used for other examples of linear thematic mapping.

  • PDF

Conductivity Characteristics of ${Ge_1}{Se_1}{Te_2}$ Amorphous Chalcogenide Thin Film for the Phase-Change Memory Application (상변화 메모리 응용을 위한 ${Ge_1}{Se_1}{Te_2}$ 비정질 칼코게나이드 박막의 전도 록성)

  • Choi, Hyuk;Kim, Hyun-Gu;Cho, Won-Ju;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.32-33
    • /
    • 2006
  • As next generation nonvolatile memory, chalcogenide-based phase change memory can substitute for a conventional flash memory from its high performance. Also, fast writing speed, low writing voltage, high sensing margin, low power consumption and repetition reliability over $10^{15}$ cycle shows its possibility. At our laboratory, we invented ${Ge_1}{Se_1}{Te_2}$ material to alternate with conventional ${Ge_2}{Sb_2}{Te_5}$ for improve its ability. We respect the ${Ge_1}{Se_1}{Te_2}$ material can be a solution for high power consumption problem and long time at 'set' performance. A conductivity experiment from variable temperature was performed to see reliability of repetition at read and write performance. Compare with conventional ${Ge_2}{Sb_2}{Te_5}$ material, these two materials are used as complex compound to get the finest parameter.

  • PDF

Application of Stereo Vision for Shape Measurement of Free-form Surface using Shape-from-shading (자유곡면의 형상 측정에서 shape-from-shading을 접목한 스테레오 비전의 적용)

  • Yang, Young-Soo;Bae, Kang-Yul
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.5
    • /
    • pp.134-140
    • /
    • 2017
  • Shape-from-shading (SFS) or stereo vision algorithms can be utilized to measure the shape of an object with imaging techniques for effective sensing in non-contact measurements. SFS algorithms could reconstruct the 3D information from a 2D image data, offering relatively comprehensive information. Meanwhile, a stereo vision algorithm needs several feature points or lines to extract 3D information from two 2D images. However, to measure the size of an object with a freeform surface, the two algorithms need some additional information, such as boundary conditions and grids, respectively. In this study, a stereo vision scheme using the depth information obtained by shape-from-shading as patterns was proposed to measure the size of an object with a freeform surface. The feasibility of the scheme was proved with an experiment where the images of an object were acquired by a CCD camera at two positions, then processed by SFS, and finally by stereo matching. The experimental results revealed that the proposed scheme could recognize the size and shape of freeform surface fairly well.