• Title/Summary/Keyword: Semi-conductor

Search Result 241, Processing Time 0.023 seconds

Response of transmission line conductors under different tornadoes

  • Dingyu Yao;Ashraf El Damatty;Nima Ezami
    • Wind and Structures
    • /
    • v.37 no.3
    • /
    • pp.179-189
    • /
    • 2023
  • Multiple studies conducted in the past evaluated the conductor response under one tornado wind field, while the performance of transmission lines under different tornado wind fields still remains unknown. Thus, the objective of this paper is to estimate the variation in the conductor's critical longitudinal and transverse reactions under different tornado wind fields, as well as providing the corresponding critical tornado configurations. The considered full-scale tornadoes are the Spencer, South Dakota, 1998, the Stockton, Kansas, 2005 and the Goshen County, Wyoming, 2009. Computational Fluid Dynamics (CFD) simulations were previously conducted to develop these wind fields. All tornadoes have been rescaled to have a common velocity matching the upper limit of the F2 Fujita scale. Eight conductor systems, each including six spans, are considered in this paper. For each conductor, parametric studies are conducted by varying the location of the three tornado wind fields relative to the tower of interest, therefore the peak reactions associated with each tornado are determined. A semi-analytical closed-form solution, previously developed and validated, is used to calculate the reactions. The study conducted in this paper can be divided into two parts: In the first part, a parametric study considering a wide range of tornado locations is conducted. In the second part, the parametric study focuses on the tornado location leading to the critical tangential velocity on the tower. Based on this extensive parametric study, a critical tornado defined as the Design Tornado and its critical locations, tornado distance R = 125 m, tornado angle 𝜃 = 15° and 30°, are recommended for design purposes.

A Study on the Load Carrying Capacity and Equivalence Friction Coefficient of a Textured Plane Bearing with Semi-spherical Dimples and Semi-ellipsoidal Dimples (반구형 및 반타원형으로 텍스처링된 평면 베어링의 부하지지능력과 등가마찰계수에 대한 해석)

  • Lee, Soo-Young;Kim, Pil-Kee;Seok, Jong-Hyuk;Seok, Jong-Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.741-746
    • /
    • 2012
  • The increase of energetic efficiency in plane bearing is getting more important in the transfer mechanism of semi-conductor and display panel manufacturing processes. To accomplish this objective, the technique of surface texturing on bearing surface has recently emerged as one of the most effective candidates. In this study, the effects of various pattern parameters on two bearing performance indices(load carrying capacity and effective friction coefficient) are investigated through a semi-analytic method, i.e., the 2-dimensional Reynolds equation incorporated into the finite difference scheme. Here, cavitation effect is also taken into account by employing an appropriate numerical scheme. In this study, the patterns in the textured surface are composed of a series of semi-spheres or semi-ellipsoids in shape. The effects of their size and number density on the performance indices are examined through the performance of various numerical experiments. Also, the effects of the anisotropy of the semi-ellipsoidal pattern on the bearing's lubrication characteristics are investigated and discussed.

A Study on Electrified Railway Traction System Impedance Calculation (전철선로 임피던스계산에 관한 연구)

  • Lee, Chon-Bae;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1407-1412
    • /
    • 2004
  • Impedance calculations of electric railway traction systems is essential to define characteristics and to design it. The self impedance is defined voltage drop rate per unit length, the mutual impedance is represented as a voltage induced to transmission line from transmission line. The self and the mutual impedance are influenced by ground return currents. The earth is considered as a semi-infinitely extended non-ideal conductor. The current of transmission line produces earth current induced magnetically and it flow through a path having minimum impedance. Carson proposed the impedance calculation formula using wave equations and magnetic field equations. Though the formula have an improper equation, that is still used as a standard impedance calculation method. This paper introduced an impedance calculation method that the complex depth of earth return method assumes that the current in conductor returns through an imagined earth depth path located directly under original conductor at a depth of. In this paper, we showed that this proposed method has a closed form and is easier than Carson's.

  • PDF

A study on dynamic design for the sub-micro vibration control of substructure in semi-conductor factory (반도체공장에서 미진동제어를 위한 격자보의 동적 설계에 관한 연구)

  • 이홍기;권형오;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.52-57
    • /
    • 1994
  • 본 논문에서는 실험적 모우드해석법을 이용하여 현재, 국내에서 가동 또는 건설 중인 반도체공장의 세가지 유형에 대한 격자보의 동적특성을 분석, 결정하고 이를 격자보의 동적설계에 활용하고자 한다.

  • PDF

LP 모형에 의한 한국 정보산업기술의 R&D 투자규모 결정사례

  • 백관호;이규헌
    • Journal of Technology Innovation
    • /
    • v.4 no.1
    • /
    • pp.27-47
    • /
    • 1996
  • The information technology, such as computer, telecommunication, semi- conductor and software technology, is very crucial to enhance the overall level of industrial technology. The workability of linear programming to decide the R&D investment of information technology has been tested in this paper. The case study of Korea during the year 1995 - 2004 suggests that we should enlarge the total investment volume especially on the software technology.

  • PDF

A Study on the Design for Pattern Generator Circuit (Pattern generator 회로 설계에 관한 연구)

  • 노영동;김준식
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.262-267
    • /
    • 2003
  • At process of production according to development of accumulation degree of semi-conductor element, because functional mistake examination time required increases, is becoming big obstacle factor in cost-cutting. Studied pattern generator that generate pattern and address that is bundle enemy to process these controversial point effectively.

  • PDF

Analysis of Trace Impurities in The Bulk $H_2$ and He Gases by a Cold Concentration Method (저온 농축법에 의한 수소와 헬륨 중의 미량가스 분석)

  • Lee, Taeck Hong;Park, Doo Seon;Son, Moo Ryong
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.5
    • /
    • pp.526-530
    • /
    • 1998
  • Analysis of trace impurities in the gases has been very important with the development of semi-conductor related industry. Particularly, the contamination of the gas handling systems in a semi-conductor plant by the air has been a trouble to the manufacturers. Thus, the analysis of the air components in the system has been a task to the analysts. In this study, we report the analysis data with a expanded uncertainty for the trace impurities of nitrogen and argon in the bulk helium and hydrogen. All data show a good correspondence, exhibiting reliable statistical error ranges.

  • PDF

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.