• Title/Summary/Keyword: Semi-aqueous

Search Result 49, Processing Time 0.021 seconds

Enviromentally Friendly Aqueous/Semi-aqueous Cleaning Technology (환경친화적 수계/준수계 세정 기술)

  • Bae, Jae-Heum;Kim, Jung-Sik
    • Clean Technology
    • /
    • v.3 no.2
    • /
    • pp.36-46
    • /
    • 1997
  • CFC and organic chlorine solvents has been used in the fine machinery and electronics industries for a long time since they have various excellent properties as cleaning agents. However, it is inevitable that alternative cleaning agents should be used since CFC and organic chlorine solvents were identified as ozone-depleting chemicals. There are various alternative cleaning agents. Among them, aqueous/semi-aqueous cleaning agents are environmentally friendly and promising in the long term. And their use and developement are on the increase in advanced countries, but few in our countries. In this paper, the charactistics and major components aqueous/semi-aqueous cleaning agents are analyzed and compared. And various cleaning equipments for aqueous/semi-aqueous cleaning agents such as immersion cleaner, ultronsonic cleaners, power spray cleaner, and vibration or rotational cleaners are compared and evaluated. Finally, important consideration points for selction of a cleaning system are analyzed and suggested in this paper.

  • PDF

Evaluation of Cleaning ability and Environmental Evaluation of Commercial Aqueous/Semi-aqueous Cleaning Agents (시판 수계/준수계 세정제의 세정성 및 환경성 평가 연구)

  • Cha, A.J.;Park, J.N.;Kim, H.S.;Bae, J.H.
    • Clean Technology
    • /
    • v.10 no.2
    • /
    • pp.73-87
    • /
    • 2004
  • In most of industrial fields, cleaning is employed for removing soils on their products or parts. Halogenated cleaning agents such as CFC-113, 1,1,1-TCE(1,1,1-trichloroethane), MC(methylene chloride) and TCE (trichloroethylene) have been used as cleaning ones in most of companies in the world since their excellent performance of cleaning ability and good material compatibility. However, CFC-113 and 1,1,1-TCE which are ozone destruction substances are not used any more in the advanced countries because of the which are ozone destruction substances are not used any more in the advanced countries because of the Montreal protocol. MC and TCE are now used restrictively at small part of industrial fields in most of countries since they are known to be hazardous or carcinogenic materials. Thus, it is indispensible that the alternative cleaning agents which are environmental-friendly and safe, and show good cleaning ability should be developed or utilized for replacement of the halogenated cleaning agents. Aqueous/semi-aqueous cleaning agents are evaluated to be promising alternative ones among various alternatives in environmental and economical view point. In this study, commercially available 12 aqueous and 6 semi-aqueous cleaning agents were selected and their physical properties, cleaning abilities, rinsing abilities and recycling of contaminated rinse water were measured and analyzed. Aqueous cleaning agents with higher wetting index showed better cleaning ability compared with those with lower wetting index. However wetting index did not have any correlation with cleaning ability in semi-aqueous cleaning agents. It was observed that soil concentration in aqueous and semi-aqueous cleaning agents should be maintained below the certain concentrations which depend on types of clearing agents. More than 70% soils in contaminated rinse water by some of aqueous and semi-aqueous clearing agents could be separated by simple settling method. This means that some cleaning agents with high oil-water separation efficiency will be effiective for recycling oil-contaminated rinse water. It was found that contaminated rinse water with aqueous agents was purified easiy by ultrafiltration method with PAN membrane of 30 kDa.

  • PDF

A Study on the Evaluation Methods of Residual Flux Cleaning Ability by Alternative Semi-Aqueous Cleaners Using Metal Test Tools After Soldering with Solder Paste (솔더페이스트로 솔더링 후 잔류 플럭스 오염물에 대한 준수계 세정제의 금속치구를 이용한 세정성능 평가방법 연구)

  • Lee, Dong-Kee
    • Clean Technology
    • /
    • v.14 no.2
    • /
    • pp.103-109
    • /
    • 2008
  • In this study, in order to develop evaluation method of the cleaning efficiency of residual flux which remains on the surface after soldering with solder paste, a specially designed metal tool is used to reduce spread uncertainty of flux while soldering. Using this tool, the measurement of cleaning efficiency of flux after soldering for some typical alternative semi-aqueous cleaners and 1,1,1-TCE by weighing method was conducted. As the test result of cleaning efficiency for each cleaner at several different cleaning times, the precision of the data is confirmed to within about 4% relative standard deviation (RSD) range. So, it is considered that this would be a good evaluation method for evaluating the cleaning efficiency of the residual flux which remains after solder paste soldering in the alternative cleaning. The results of this test method shows that the cleaning efficiency of ST 100SX and Neozal 750H in the cleaning of residual flux was better than other semi-aqueous cleaners, but its cleaning efficiency was clearly inferior to 1,1,1-TCE.

  • PDF

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.

Synthesis, Characterization and Swelling Properties of Chitosan/Poly(acrylic acid-co-crotonic acid) Semi-Interpenetrating Polymer Networks (Chitosan/Poly(acrylic acid-co-crotonic acid) Semi-IPN의 합성, 분석 및 팽윤거동)

  • Hosseinzadeh, Hossein;Alijani, Darioush
    • Polymer(Korea)
    • /
    • v.38 no.5
    • /
    • pp.588-595
    • /
    • 2014
  • A semi-interpenetrating polymer network (semi-IPN) hydrogel composed of crosslinked chitosan and poly (acrylic acid-co-crotonic acid) was prepared in the presence of glutaraldehyde (GA) as a crosslinker. Fourier-transform infrared, thermogravimetric analysis and scanning electron microscopy were employed to confirm the structure of the semi-IPN hydrogel. The swelling capacity of hydrogel was shown to be affected by the monomers weight ratio, chitosan content, initiator and GA concentrations. The results also indicated that the semi-IPN hydrogel had different swelling capacity at various pHs. Additionally, the swelling behavior of the hydrogel was investigated in aqueous solutions of NaCl, $CaCl_2$, and $AlCl_3$.

Characteristics of Semi-Aqueous Cleaning Solution with Carboxylic Acid for the Removal of Copper Oxides Residues (산화구리 잔유물 제거를 위한 카르복시산 함유 반수계 용액의 세정특성)

  • Ko, Cheonkwang;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.54 no.4
    • /
    • pp.548-554
    • /
    • 2016
  • In this study, semi-aqueous solutions containing carboxylic acids such as oxalic acid (OA), lactic acid (LA) and citric acid (CA) were formulated for the removal of copper etching residues produced at the interconnection process, and their characteristics were analyzed. Carboxylic acids in the solutions were apt to form various copper complexes according to the value of pH. Semi-aqueous solution containing 10 wt% CA showed the lowest etching rate of copper in the range from pH2 to pH7 and the highest selectivity in the range of pH 2 to pH 4. However, the cleaning solution containing 10 wt% LA revealed the superior selectivity at the range from pH 5 to pH 7. Appropriate selection of carboxylic acid should be required to improve the performance of cleaning solution. In the case of CA, the etching selectivity of copper oxide complex to copper was increased with the concentration of CA in the solution, when the solutions contain over 5 wt% CA, the copper interconnection layer has a metallic copper surface more than 88% in the area. The result shows that CA contained semi-aqueous solution has a relatively good cleaning ability.

Semi-Automatic Hydride Generation and Atomic Absorption Determination of Bismuth with in situ Concentration in a Graphite Furnace

  • Yong-Keun Lee;Dong Soo Lee;Byung Mok Yoon;Hoon Hwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.12 no.3
    • /
    • pp.290-295
    • /
    • 1991
  • A semi-automatic method for the determination of dissolved bismuth at parts per trillion levels is described. The method involves bismuthine generation, in situ collection of bismuthine in a graphite furnace, and atomic absorption detection. In order to facilitate semi-automation of bismuthine generation and separation from aqueous solution, Gore-tex microporous PTEE membrane is used. The absolute detection limit, taken as three times the standard deviation of the instrument noise is 2 pg. The precisions are 3.1% for 100 pg and 1.9% for 1 ng of bismuth, respectively. As many as 90 measurements can be made in an hour.

Separation Purification Characteristics of Rinsing Solution in Semiconductor Process using Bigh Performance Polymer Membranes ( I ) (기능성 고분자막을 이용한 반도체 공정 세정액의 분리정제특성 (I))

  • Lee Jae-Dal;Hong Young-Ki;Ro Duck-Kil;Bae Kie-Seo
    • Textile Coloration and Finishing
    • /
    • v.17 no.3 s.82
    • /
    • pp.34-42
    • /
    • 2005
  • In this work, a practical separation performance was investigated on aqueous alcohol solutions, especially for iso-propyl alcohol (IPA), which is usually used during the semi- conductor rinsing process. The removal of various substances from waste aqueous IPA solutions was carried out by microfiltration with $0.1\~1{\mu}$m pore size of mean diameter as a pre-filter. Permeability and molecular weight cut-off of the functional polysulfone(PSf) ultrafiltration membrane to purify waste aqueous IPA solutions were measured through the ultrafiltration test. The solute rejection of PSf membrane had $92\%$ in 1,000ppm aqueous PEG solution with PEG molecular weight 10,000, the molecular weight cut-off had 10,000. The IPA concentration on the $CMPA-K^+$ membrane performance using pervaporation module system could be increased from $95.04 wt\%$ to more than $98.50wt\%$ in about 9hr at operation temperature of $70^{\circ}C$ using the pervaporation module system.

Preparation of Semi-solid Fibroin Gel and its Flow Property (반고형 피브로인 단백질 겔의 제조 및 유동특성)

  • Hur, Won;Lee, Shin-Young
    • KSBB Journal
    • /
    • v.24 no.6
    • /
    • pp.563-569
    • /
    • 2009
  • Fibroin is an insoluble structural protein from Bombyx mori. It can be solubilized by dissolving in a hot $CaCl_2$ solution and subsequent dialysis. The aqueous solution is unstable and a transition from aqueous fibroin molecules rich in random coil is undergo to one rich in $\beta$-sheet content, resulting in hydrogelation. However, fibroin gel is so fragile and plastic that its mechanical property should be reformed for various applications. In this report, a semi-solid form of fibroin gel was prepared using glycerol and ethanol and was investigated to analyze their flow properties. A fibroin gel with 80% glycerol showed pseudoplastic and thixotropic properties. The square root of its yield stress varied linearly with fibroin concentration and it extrapolated to zero shear stress at 0.2% fibroin. A fibroin gel with 40% ethanol was shown to be highly thixotropic but its shear-thinning behavior was only observed above a certain level of shear rate. Its pseudoplasticity was restored by a high rate of shear stress.

Increased 26S proteasome non-ATPase regulatory subunit 1 in the aqueous humor of patients with age-related macular degeneration

  • Lee, Hyungwoo;Choi, Ae Jin;Kang, Gum-Yong;Park, Hyung Soon;Kim, Hyung Chan;Lim, Hyunjung Jade;Chung, Hyewon
    • BMB Reports
    • /
    • v.47 no.5
    • /
    • pp.292-297
    • /
    • 2014
  • Age-related macular degeneration (AMD) is the leading cause of blindness in the world. Evidence indicates that the suppression of the ubiquitin-proteasome system (UPS) contributes to the accumulation of toxic proteins and inflammation in retinal pigment epithelium (RPE), the functional abnormalities and/or the degeneration of which are believed to be the initiators and major pathologies of AMD. To identify new protein associations with the altered UPS in AMD, we used LC-ESI-MS/MS to perform a proteomic analysis of the aqueous humor (AH) of AMD patients and matched control subjects. Six UPS-related proteins were present in the AH of the patients and control subjects. Four of the proteins, including 26S proteasome non-ATPase regulatory subunit 1 (Rpn2), were increased in patients, according to semi-quantitative proteomic profiling. An LC-MRM assay revealed a significant increase of Rpn2 in 15 AMD patients compared to the control subjects, suggesting that this protein could be a biomarker for AMD.