• Title/Summary/Keyword: Self-ligating system

Search Result 7, Processing Time 0.017 seconds

Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial

  • Rahman, Norma Ab;Wey, Mang Chek;Othman, Siti Adibah
    • The korean journal of orthodontics
    • /
    • v.47 no.1
    • /
    • pp.11-20
    • /
    • 2017
  • Objective: This randomized controlled trial aimed to compare the stability of mandibular arch orthodontic treatment outcomes between passive self-ligating and conventional systems during 6 months of retention. Methods: Forty-seven orthodontic patients with mild to moderate crowding malocclusions not requiring extraction were recruited based on inclusion criteria. Patients (mean age $21.58{\pm}2.94years$) were randomized into two groups to receive either passive self-ligating ($Damon^{(R)}$ 3MX, n = 23) or conventional system (Gemini MBT, n = 24) orthodontic treatment. Direct measurements of the final sample comprising 20 study models per group were performed using a digital caliper at the debonding stage, and 1 month, 3 months, and 6 months after debonding. Paired t-test, independent t-test, and non-parametric test were used for statistical analysis. Results: A significant increase (p < 0.01) in incisor irregularity was observed in both self-ligating and conventional system groups. A significant reduction (p < 0.01) in second interpremolar width was observed in both groups. Mandibular arch length decreased significantly (p = 0.001) in the conventional system group but not in the self-ligating system group. A similar pattern of stability was observed for intercanine width, first interpremolar width, intermolar width, and arch depth throughout the 6-month retention period after debonding. Comparison of incisor irregularity and arch dimension changes between self-ligating system and conventional system groups during the 6 months were non-significant. Conclusions: The stability of treatment outcomes for mild to moderate crowding malocclusions was similar between the self-ligating system and conventional system during the first 6 months of retention.

Randomized controlled clinical trial of oral health-related quality of life in patients wearing conventional and self-ligating brackets

  • Othman, Siti Adibah;Mansor, Noorhanizar;Saub, Roslan
    • The korean journal of orthodontics
    • /
    • v.44 no.4
    • /
    • pp.168-176
    • /
    • 2014
  • Objective: The aim of this randomized controlled clinical trial was to compare oral health-related quality of life (OHRQoL) of patients treated with conventional, active self-ligating (ASL), and passive self-ligating (PSL) brackets in different therapeutic phases. Methods: Sixty patients (mean age 18.3 years; 29 males and 31 females) requiring orthodontic treatment were randomly and equally assigned to receive conventional (Victory Series), ASL (In-Ovation R), or PSL (Damon 3MX) brackets. OHRQoL was measured with a self-administered modified 16-item Malaysian version of the Oral Health Impact Profile for immediate (soon after the visit) and late (just before the subsequent visit) assessments of the bonding and activation phases. Data were analyzed with the Kruskal-Wallis and chi-square tests. Results: The PSL and ASL groups showed more immediate and late impacts in the bonding phase, respectively; the conventional group was affected in both the assessments. The first activation phase had similar impacts in the groups. After the second activation, the conventional group showed more immediate impacts, whereas the PSL and ASL groups had more late impacts. The commonly affected domains were "physical disability," "functional limitation," "physical pain," and "psychological discomfort." No significant differences in the prevalence and severity of immediate and late impacts on OHRQoL of the patients were noted in any therapeutic phase. Conclusions: No bracket system seems to ensure superior OHRQoL. This information could be useful for explaining the therapeutic phases, especially the initial one, and selecting the optimal bracket system based on the patient's preference.

In vitro evaluation of resistance to sliding in self-ligating and conventional bracket systems during dental alignment

  • Cordasco, Giancarlo;Giudice, Antonino Lo;Militi, Angela;Nucera, Riccardo;Triolo, Giuseppe;Matarese, Giovanni
    • The korean journal of orthodontics
    • /
    • v.42 no.4
    • /
    • pp.218-224
    • /
    • 2012
  • Objective: To investigate the resistance to sliding (RS) in self-ligating and conventional ligation bracket systems at 5 different second-order bracket angulations by using low-stiffness alignment wires in a 3-bracket experimental model and to verify the performance of the main RS components in both systems when these wires are used. Methods: Interactive self-ligating brackets with closed and open slides were used for the self-ligating (SL) and conventional ligation (CL) groups, respectively; elastomeric ligatures (1 mm inner diameter) were used in the latter system. The alignment wire used was 0.014 inch heat-activated NiTi (austenitic finish temperature set at $36^{\circ}C$ by the manufacturer). A custom-made testing machine was used to measure frictional resistance. Tests were repeated 5 times at every angulation simulated. All data were analyzed statistically. Results: The RS increased significantly with increasing angulation in both SL and CL groups (p < 0.0001). However, the RS values were significantly higher at every angulation (p < 0.0001) in the CL group. Conclusions: Despite the relevance of the binding phenomenon, ligation forces predominantly affect the RS when lowstiffness alignment wires are used.

Effect of passive self-ligating bracket placement on the posterior teeth on reduction of frictional force in sliding mechanics

  • Kim, Kyu-Ry;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.73-80
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the static (SFF) and kinetic frictional forces (KFF) in sliding mechanics of hybrid bracket systems that involve placing a conventional bracket (CB) or active self-ligating bracket (ASLB) on the maxillary anterior teeth (MXAT) and a passive SLB (PSLB) on the maxillary posterior teeth (MXPT). Methods: The samples consisted of two thoroughbred types (group 1, anterior-CB + posterior-CB; group 2, anterior-ASLB + posterior-ASLB) and four hybrid types (group 3, anterior-CB + posterior-PSLB-type 1; group 4, anterior-CB + posterior-PSLB-type 2; group 5, anterior-ASLB + posterior-PSLB-type 1; group 6, anterior-ASLB + posterior-PSLB-type 2) (n = 13 per group). After maxillary dentition alignment and maxillary first premolars removal in the stereolithographically-made typodont system, a $0.019{\times}0.025$-inch stainless steel wire was drawn through the right quadrant of the maxillary arch at 0.5 mm/min for 5 min. The SFF and KFF were measured with a mechanical testing machine and statistical analyses were performed. Results: Four different categories of SFF and KFF were observed among all groups (all p < 0.001). Group 1 demonstrated the highest SFF and KFF; groups 4 and 3 were second and third highest, respectively. The fourth category included groups 2, 5, and 6. Placing PSLBs on the MXPT resulted in significant SFF and KFF reductions in cases with CBs on the MXAT, but not in cases with ASLBs on the MXAT. Conclusions: These data might aid in the development of a hybrid bracket system that enables low-friction sliding of an archwire through the MXPT.

Frictional property comparisons of conventional and self-ligating lingual brackets according to tooth displacement during initial leveling and alignment: an in vitro mechanical study

  • Kim, Do-Yoon;Lim, Bum-Soon;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.46 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Objective: We evaluated the effects of tooth displacement on frictional force when conventional ligating lingual brackets (CL-LBs), CL-LBs with a narrow bracket width, and self-ligating lingual brackets (SL-LBs) were used with initial leveling and alignment wires. Methods: CL-LBs (7th Generation), CL-LBs with a narrow bracket width (STb), and SL-LBs (In-Ovation L) were tested under three tooth displacement conditions: no displacement (control); a 2-mm palatal displacement (PD) of the maxillary right lateral incisor (MXLI); and a 2-mm gingival displacement (GD) of the maxillary right canine (MXC) (nine groups, n = 7 per group). A stereolithographic typodont system and artificial saliva were used. Static and kinetic frictional forces (SFF and KFF, respectively) were measured while drawing a 0.013-inch copper-nickel-titanium archwire through brackets at 0.5 mm/min for 5 minutes at $36.5^{\circ}C$. Results: The In-Ovation L exhibited lower SFF under control conditions and lower KFF under all displacement conditions than the 7th Generation and STb (all p < 0.001). No significant difference in SFF existed between the In-Ovation L and STb for a 2-mm GD of the MXC and 2-mm PD of the MXLI. A 2-mm GD of the MXC produced higher SFF and KFF than a 2-mm PD of the MXLI in all brackets (all p < 0.001). Conclusions: CL-LBs with narrow bracket widths exhibited higher KFF than SL-LBs under tooth displacement conditions. CL-LBs and ligation methods should be developed to produce SFF and KFF as low as those in SL-LBs during the initial and leveling stage.

Long-term stability of dentoalveolar, skeletal, and soft tissue changes after non-extraction treatment with a self-ligating system

  • Basciftci, Faruk Ayhan;Akin, Mehmet;Ileri, Zehra;Bayram, Sinem
    • The korean journal of orthodontics
    • /
    • v.44 no.3
    • /
    • pp.119-127
    • /
    • 2014
  • Objective: To evaluate the long-term effects of self-ligating brackets (SLBs) on transverse dimensions of arches and skeletal and soft tissues and to quantitatively evaluate the treatment outcome after non-extraction treatment with SLBs. Methods: The sample consisted of 24 (18 female and six male) subjects, with a mean age of $14.23{\pm}2.19$ years, who received treatment with the Damon$^{(R)}$3 appliances. Complete records including cephalometric radiographs and plaster models were obtained before treatment (T1), immediately after treatment (T2), six months after treatment (T3), and two years (T4) after treatment. Digital study models were generated. Twenty lateral cephalometric, six frontal cephalometric, and eight dental cast measurements were examined. The Peer Assessment Rating index was used to measure the treatment outcome. The Wilcoxon test was applied for statistical analysis of the changes. Results: There were significant increases in all transverse dental cast measurements with active treatment. There was some significant relapse in the long term, particularly in maxillary width (p < 0.05). Statistically significant increases were found in nasal (p < 0.001), maxillary base, upper molar, lower intercanine, and antigonial (p < 0.05) widths in T1-T2. Lower incisors were proclined and protruded in T1-T2. Conclusions: SLBs correct crowding by mechanisms involving incisor proclination and protrusion and expansion of the dental arches, without induction of clinically significant changes in hard and soft tissues of the face.