• Title/Summary/Keyword: Self-calibration Method

Search Result 63, Processing Time 0.024 seconds

A Case Study of Quality Assurance and Control for the Soil Environmental Assessment in Abandoned Mine (광산지역 토양정밀조사 정도관리(QA/QC) 사례 연구)

  • Ji, Won Hyun;Kim, Jong Keun
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.134-141
    • /
    • 2014
  • A testing inspection is one of the important in the industry, owing to determine the reliability and directivity of testing inspection results. Therefore, the quality assurance and quality control (QA/QC) work which performed by personnel not directly in the inventory compilation development, in testing inspection must be thoroughly considered. Some agencies for environmental test inspection, they sometimes misunderstood that the QA/QC was ended with proficiency testing performance and on-site assessment by a director. Thus, results were often calculated without QA/QC work by self manual when conducting test. The objective of this study was to improve reliability of testing and inspection agency through the QA/QC case study which basically performed to raising reliability of testing and inspection agency. In this study, it increased reliability of result by verifying calibration curve (IC, ICV, CCV), blank, accuracy (LCS, MS) and precision as QA/QC performance, while performing investigation of soil contamination in mining areas. This study suggests that reliability establishing method of test result and management method of analysis process, through the QA/QC instance of testing agency.

Probabilistic Calibration of Computer Model and Application to Reliability Analysis of Elasto-Plastic Insertion Problem (컴퓨터모델의 확률적 보정 및 탄소성 압착문제의 신뢰도분석 응용)

  • Yoo, Min Young;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1133-1140
    • /
    • 2013
  • A computer model is a useful tool that provides solution via physical modeling instead of expensive testing. In reality, however, it often does not agree with the experimental data owing to simplifying assumption and unknown or uncertain input parameters. In this study, a Bayesian approach is proposed to calibrate the computer model in a probabilistic manner using the measured data. The elasto-plastic analysis of a pyrotechnically actuated device (PAD) is employed to demonstrate this approach, which is a component that delivers high power in remote environments by the combustion of a self-contained energy source. A simple mathematical model that quickly evaluates the performance is developed. Unknown input parameters are calibrated conditional on the experimental data using the Markov Chain Monte Carlo algorithm, which is a modern computational statistics method. Finally, the results are applied to determine the reliability of the PAD.

A study on the spray characteristics of a coaxial nozzle by LDV measurement (LDV계측에 의한 동축노즐의 분무특성 연구)

  • 윤석주;노병준
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1613-1620
    • /
    • 1990
  • For the purpose of the study on the spray characteristics of a coaxial nozzle, the measurement of the velocity and size of droplets, concentration, and the statistical correlation coefficient between the fluctuation of the velocity and that of the corresponding drop diameter have been carried out. Various method of simultaneous measurement of velocity and drop size have been developed from LDV techniques. The technique used here belongs to the method that supposed by Yule, Holve and Self. It has the advantages of making use of a standard LDV apparatus to which minor modifications have been brought, photomultiplier is equipped with a slit instead of a pinhole and observed the measuring volume at an angle of 90.deg.. The voltage supplied by the photomultiplier has undergone an appropriate analog and digital processing. The experimental results give a good idea of the two phase flow organization and can be helpful to find a drop diffusion model when suitable data are imput.

Estimation of the Fundamental Matrix using a Non-linear Minimization Technique and Its Accuracy Analysis (비선형 최소화에 의한 F행렬 추정 및 정확도 분석)

  • Eom, Seong-Hun;Lee, Jong-Su
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.38 no.6
    • /
    • pp.657-664
    • /
    • 2001
  • It is possible to extract a 3D models from its multiple views using the self-calibration. Though it is possible to construct 3D models of objects from their multiple views, accuracy of 3D models depends on the fundamental matrix estimated between two views. In this paper, we show the fundamental matrix accuracy can be improved by taking a non-linear minimization technique. Furthermore, the corresponding points which are completely mismatches or have greater discrepancy errors in their locations, reduce the fundamental matrix accuracy. Thus, applying the Monte Carlo technique and the non-linear minimization Levenberg-Marquardt method to remove the outliers, we can estimate the fundamental matrix with the higher accuracy.

  • PDF

A Study on the Development of New Coded Targets for a Mobile Mapping System (차량측량시스템을 위한 코드 타겟 개발에 관한 연구)

  • Eom, Woo-Hak;Kim, Byung-Guk
    • Journal of Korea Spatial Information System Society
    • /
    • v.5 no.2 s.10
    • /
    • pp.83-89
    • /
    • 2003
  • In this study, a new coded targets that being suitable for a Mobile Mapping System and method of automated target recognition and coordinates determination of center point was developed, the purpose of a Mobile Mapping System is acquisition and logging data around the road for the camera calibration and the Exterior orientation of system, target installed previously and CCD cameras captured the image, target center point was observed by hands, but using coded target, target recognition and center point observation process will be automated effectively, in addition we keeped up the consistency of photo coordinates observation.

  • PDF

Calibration of cylindrical NaI(Tl) gamma-ray detector intended for truncated conical radioactive source

  • Badawi, Mohamed S.;Thabet, Abouzeid A.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1421-1430
    • /
    • 2022
  • The computation of the solid angle and the detector efficiency is considering to be one of the most important factors during the measuring process for the radioactivity, especially the cylindrical γ-ray NaI(Tl) detectors nowadays have applications in several fields such as industry, hazardous for health, the gamma-ray radiation detectors grow to be the main essential instruments in radiation protection sector. In the present work, a generic numerical simulation method (NSM) for calculating the efficiency of the γ-ray spectrometry setup is established. The formulas are suitable for any type of source-to-detector shape and can be valuable to determine the full-energy peak and the total efficiencies and P/T ratio of cylindrical γ-ray NaI(Tl) detector setup concerning the truncated conical radioactive source. This methodology is based on estimate the path length of γ-ray radiation inside the detector active medium, inside the source itself, and the self-attenuation correction factors, which typically use to correct the sample attenuation of the original geometry source. The calculations can be completed in general by using extra reasonable and complicate analytical and numerical techniques than the standard models; especially the effective solid angle, and the detector efficiency have to be calculated in case of the truncated conical radioactive source studied condition. Moreover, the (NSM) can be used for the straight calculations of the γ-ray detector efficiency after the computation of improvement that need in the case of γ-γ coincidence summing (CS). The (NSM) confirmation of the development created by the efficiency transfer method has been achieved by comparing the results of the measuring truncated conical radioactive source with certified nuclide activities with the γ-ray NaI(Tl) detector, and a good agreement was obtained after corrections of (CS). The methodology can be unlimited to find the theoretical efficiencies and modifications equivalent to any geometry by essential sufficiently the physical selective considered situation.

A Design of 10bit current output Type Digital-to-Analog converter with self-Calibration Techique for high Resolution (고해상도를 위한 DAC 오차 보정법을 가진 10-비트 전류 출력형 디지털-아날로그 변환기 설계)

  • Song, Jung-Gue;Shin, Gun-Soon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.4
    • /
    • pp.691-698
    • /
    • 2008
  • This paper describes a 3.3V 10 bit CMOS digital-to-analog converter with a divided architecture of a 7 MSB and a 3 LSB, which uses an optimal Thermal-to-Binary Decoding method with monotonicity, glitch energy. The output stage utilizes here implements a return-to-zero circuit to obtain the dynamic performance. Most of D/A converters in decoding circuit is complicated, occupies a large chip area. For these problems, this paper describes a D/A converter using an optimal Thermal-to-Binary Decoding method. the designed D/A converter using the CMOS n-well $0.35{\mu}m$ process0. The experimental data shows that the rise/fall time, settling time, and INL/DNL are 1.90ns/2.0ns, 12.79ns, and a less than ${\pm}2.5/{\pm}0.7\;LSB$, respectively. The power dissipation of the D/A converter with a single power supply of 3.3V is about 250mW.

Evaluation of Clinical Availability for Shoulder Forced Traction Method to Minimize the Beam Hardening Artifact in Cervical-spine Computed Tomography (CT) (경추부 전산화단층촬영에서 선속 경화 인공물을 최소화하기 위한 견부 강제 견인법에 대한 임상적 유용성 평가)

  • Kim, Moonjeung;Cho, Wonjin;Kang, Suyeon;Lee, Wonseok;Park, Jinwoo;Yu, Yunsik;Im, Inchul;Lee, Jaeseung;Kim, Hyeonjin;Kwak, Byungjoon
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.37-44
    • /
    • 2013
  • In study suggested clinical availability to shoulder forced traction method in term of quality of image, the patient's convenience and stability, according to whether to use of shoulder forced traction bend using computed tomography(CT) that X-ray calibration and various mathematic calibration algorithm application can be applied by AEC. To achieve this, 79 patients is complaining of cervical pain oriented that shoulder forced traction bend use the before and after acquires lateral projection scout image and transverse image. transverse image of a fixed size in concern field of pixel and figure the average HU value compare that quantitative analysis. Artifact and pixel and resolution to qualitative clinical estimation image analysis. the patient feel inconvenience degree that self-diagnosis survey that estimate. As a result, lateral projection scout image if you used shoulder forced traction bend for the depicted has been an increase in the number of a cervical vertebrae. transverse image concern field shoulder forced traction bend use the before and after for pixel and the average HU-value changes was judged to be almost irrelevant. Artifact and resolution and contrast, in qualitative analysis of the results relating the observer to the unusual result. So, the patients of 82.27% complained discomfort that use of shoulder forced traction bend in self-diagnosis survey. No merit of medical image by using of bend from result was analyzed quality of image to quantitative and qualitative method judged. Nowadays, CT is supplied possible revision of quality of radiation by reduction of slice and automatic exposure controller, etc and application of preconditioning filter process due to various mathematic revision algorithm. So, image noise by beam hardening artifact should not be a problem. shoulder forced traction bend of use no longer judged clinically availability because have not influence of image quality and give discomfort, have extra dangerousness.

Measurement of Soil Deformation around the Tip of Model Pile by Close-Range Photogrammetry (근접 사진측량에 의한 모형말뚝 선단부 주변의 지반 변형 측정)

  • Lee, Chang No;Oh, Jae Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.2
    • /
    • pp.173-180
    • /
    • 2013
  • In this paper, we studied on measurement of soil deformation around the tip of model pile by close-range photogrammetry. The rigorous bundle adjustment method was utilized to monitor the soil deformation in the laboratory model pile-load test as function of incremental penetration of the pile. Control points were installed on the frame of the laboratory model box case and more than 150 target points were inserted inside the soil around the model pile and on the surface. Four overlapping images including three horizontal and one vertical image were acquired by a non-metric camera for each penetration step. The images were processed to automatically locate the control and target points in the images for the self-calibration and the bundle adjustment. During the bundle adjustment, the refraction index of the acrylic case of the laboratory model was accounted for accurate measurement. The experiment showed the proposed approach enabled the automated photogrammetric monitoring of soil deformation around the tip of model pile.

Fundamental Investigation of Non-invasive Determination of Glucose by Near Infrared Spectrophotometry (근적외선 분광법을 이용한 비침투적 혈당 분석법 개발에 관한 기초 연구)

  • Kim, Hyo J.;Woo, Young A.;Chang, Soo H.;Cho, Chang H.;Cantrell, Kevin;Piepmeier, Edward H.
    • Analytical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • This study is to improve the diagnosis of diabetes mellitus and the self-monitoring of blood glucose in people with diabetes by providing a non-invasive method of monitoring blood glucose. A near-infrared (NIR) spectrophotometer was used to measure absorption spectra of 80 glucose samples ranges from 1 mg/dL to 200 mg/dL, and shows the standard error of prediction 1.8 mg/dL. Also, to investigate the effect of interference in blood, NaCl and sand were added in glucose and found the standard error of prediction of 2.8 mg/dL and 3.8 mg/dL, respectively. A new and more accurate calibration system for the spectrophotometer was developed from systematic study of light scattering, which cause nonlinear spectrophotometer response.

  • PDF