• 제목/요약/키워드: Seismic strengthening

검색결과 217건 처리시간 0.027초

Seismic performance evaluation of fiber-reinforced prestressed concrete containments subject to earthquake ground motions

  • Xiaolan Pan;Ye Sun;Zhi Zheng;Yuchen Zhai;Lianpeng Zhang
    • Nuclear Engineering and Technology
    • /
    • 제56권5호
    • /
    • pp.1638-1653
    • /
    • 2024
  • Given the unpredictability of the occurrence of the earthquake and other potential disasters into consideration, the nuclear power plant may be confronted with beyond design-basis earthquake load in the future. The containment structure may be severely damaged under such severe earthquake loading, increasing the risk of containment concrete cracking and potential radioactive materials leaking. Moreover, initial damage caused by the earthquake may significantly alter the pressure performance of the containment under follow-up internal pressure. To compromise the dangers of beyond design-basis earthquake to the containment, an alternative of replacing the conventional concrete with fiber-reinforced concrete (FRC) to upgrade the seismic resistance capacity of the containment is attempted and thoroughly researched. In this study, the influence of various fiber types such as rigid fiber and mixed fiber is regarded to constitute fiber-reinforced PCCVs. The physical properties of traditional and fiber-reinforced PCCVs under earthquake ground motions are scientifically compared and identified by using traditional and proposed evaluation indices. The results indicate that both the traditional evaluation index (i.e. top displacement, stress, strain) and the proposed damage index are greatly reduced by the practice of fiber strengthening under earthquake ground motions.

Performance-based framework for soil-structure systems using simplified rocking foundation models

  • Smith-Pardo, J. Paul
    • Structural Engineering and Mechanics
    • /
    • 제40권6호
    • /
    • pp.763-782
    • /
    • 2011
  • Results from nonlinear time-history analyses of wall-frame structural models indicate that the condition of vulnerable foundations -for which uplifting and reaching the bearing capacity of the supporting soil can occur before yielding at the base of the shear walls- may not be necessarily detrimental to the drift response of buildings under strong ground motions. Analyses also show that a soil-foundation system can inherently have deformation capacity well in excess of the demand and thus act as a source of energy dissipation that protects the structural integrity of the shear walls.

납-고무베어링을 적용한 제어장치의 동적평가를 위한 해석적 연구 (Analytical Study to Determine the Dynamic Property of Control Equipment Room using LRB)

  • 김우범;김대곤;이경진;박병구
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.473-480
    • /
    • 2003
  • In these days, The base isolation system is often used improve the seismic capacity of the structure Instead of conventional techniques of strengthening the structural members. The purpose of this study is to evaluate dynamic property evaluation of control equipment using Lead Rubber Bearing. In this study, analysis numerical was performed to determine the optimal dynamic property of lead rubber bearing and damper which minimize the response of base from in main control room. Also the analytical results was composed with the test results peformed in previous study

  • PDF

확대단면에서의 띠철근 배근 방법에 따른 보강 기둥의 중심 축하중 거동 평가 (Evaluation of Axial Behavior of Columns Strengthened with Different Transverse Reinforcements in Jacket Section)

  • 황용하;양근혁;심재일;최용수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권6호
    • /
    • pp.81-88
    • /
    • 2018
  • 이 연구에서는 실제 단면크기를 갖는 철근 콘크리트 기둥의 내진보강을 위한 단면확대 공법에서 효율적인 띠철근 배근 방법을 평가하였다. 비내진 상세를 갖는 기존 기둥의 단면크기는 $450{\times}450mm$이며, 단면확대 보강기둥의 단면크기는 $750{\times}750mm$이다. 확대 단면에서의 폐쇄형 외부 띠철근 배근을 위해 ㄷ-형 띠철근의 겹칩이음 및 철근 선조립 공법을 제시하였으며, 보조 띠철근으로서 크로스타이 앵커링 시공 및 V-타이를 고려하였다. 실험 결과, 무보강 기둥 및 ㄷ-형 외부 띠철근을 적용한 보강기둥의 압축내력은 ACI 318-14의 공칭내력과 비슷한 수준인 반면 철근 선조립 공법을 적용한 기둥의 압축내력은 ACI 318-14의 공칭내력 대비 1.25배 높았다. 특히 철근 선조립 공법을 적용한 보강 기둥의 압축 연성비는 크기효과에 의한 연성비 저하 가능성에도 불구하고 기존 기둥에 비해 139% 증가하였다. 즉, 제시된 철근 선조립 공법은 단면확대 보강기둥에서 주철근 조기 좌굴방지 및 콘크리트 구속에 효율적인 띠철근 상세로 평가될 수 있었다.

프리캐스트 ECC 벽판으로 보강된 비내진 상세를 갖는 철근콘크리트 골조의 내진성능 (Seismic Performance of Non-ductile Reinforced Concrete Frames with Precast ECC Wall Panels)

  • 김지현;조성필;서수연;윤현도
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.105-112
    • /
    • 2019
  • 본 논문은 비내진 상세를 갖는 철근콘크리트 골조 및 필로티 건물의 보강방법으로 높은 연성을 갖는 ECC를 적용한 PC 벽판을 내진 보강요소로 사용하고자 하였다. PC 벽판의 형상비 및 설치 위치를 변수로 RC 골조에 대한 반복가력실험을 실시하여 내진성능을 평가하였다. 실험결과 PC 벽판을 보강함에 따라 기존 RC 골조의 내력 증진, 강도저하 방지, 강성증진 및 에너지 소산능력 향상에 효과적인 것으로 나타났다. 실험결과를 근거로 비내진 상세를 갖는 골조의 강도 증진을 위하여 ECC PC 벽판을 골조의 중앙에 설치하고 연성증진을 위하여 세장한 벽판을 골조의 양측면에서 설치할 것을 제안한다.

Performance evaluation of a seismic retrofitted R.C. precast industrial building

  • Nastri, Elide;Vergato, Mariacristina;Latour, Massimo
    • Earthquakes and Structures
    • /
    • 제12권1호
    • /
    • pp.13-21
    • /
    • 2017
  • Recent seismic events occurred in Italy (Emilia-Romagna 2012, Abruzzo 2009) and worldwide (New Zealand 2010 and 2011) highlighted some of the weaknesses of precast concrete industrial buildings, especially those related to the connecting systems traditionally employed to fasten the cladding panels to the internal framing. In fact, one of the most commons fails it is possible to observe in such structural typologies is related to the out-of-plane collapse of the external walls due to the unsatisfactory behaviour of the connectors used to join the panels to the perimeter beams. In this work, the strengthening of a traditional industrial building, assumed as a case study, made by precast reinforced concrete is proposed by the adoption of a dual system allowing the reinforcement of the structure by acting both internally; by pendular columns and, externally, on the walls. In particular, traditional connections at the top of the walls are substituted by devices able to work as a slider with vertical axis while, the bottom of the walls is equipped with two or more hysteretic dampers working on the uplift of the cladding panels occurring under seismic actions. By means of this approach, the structure is stiffened; obtaining a reduction of the lateral drifts under serviceability limit states. In addition, its seismic behaviour is improved due to the additional source of energy dissipation represented by the dampers located at the base of the walls. The effectiveness of the suggested retrofitting approach has been checked by comparing the performance of the retrofitted structure with those of the structure unreinforced by means of both pushover and Incremental Dynamic Analyses (IDA) in terms of behaviour factor, assumed as a measure of the ductility capacity of the structure.

고연성 PET-AF 스트랜드로 외부 보강한 RC 원형 기둥의 내진 성능에 관한 실험적 연구 (Experimental Investigation on Seismic Performance of RC Circular Columns Strengthened Using Highly-Ductile PET-AF Fiber Strand)

  • 곰보수렌 진저릭트;김소영;최동욱;임명관;이진용
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권5호
    • /
    • pp.56-66
    • /
    • 2017
  • 이 연구에서는 고연성 PET 시트 및 HF(PET+aramid) 스트랜드로 보강한 RC 원형 기둥의 내진 보강 성능에 대하여 실험적으로 비교 고찰하였다. 고연성 PET 및 HF 스트랜드로 횡 구속된 RC 원형 기둥의 내진 성능 실험결과, 모든 보강 기둥에서 최대 휨 강도 및 연성 능력 모두 무보강 기둥보다 향상되었으며 극한단계에서 섬유의 파단은 발생하지 않았다. 또한 PET 시트 25겹 보강 기둥과 HF 스트랜드 1겹 보강 기둥의 저항 내력 및 변위가 거의 유사하여 HF 스트랜드 1겹은 PET 시트 약 25겹(동일 폭 기준)과 동일한 횡 구속 효과를 나타내었다. 결과적으로 휨 강도 증진 및 연성 능력 측면에서 PET는 RC 구조물의 내진 보강재로서 적합한 것으로 사료되나 현장적용의 가능성을 높이기 위해서는 이 연구에서 사용된 HF 스트랜드와 같이 많은 양의 섬유를 함유한 제작품과 같이 1겹으로 다수 PET 시트의 성능 효과를 내는 재료가 필요할 것으로 사료된다. 한편 PET의 내구성에 대해서는 별도의 연구가 필요하며 현재 연구가 진행중이다.

콘크리트채움 U형 강재보-강재기둥 합성 내진접합부에 대한 주기하중 실험 (Cyclic Seismic Testing of Concrete-filled U-shaped Steel Beam-to-Steel Column Connections)

  • 박홍근;이철호;박창희;황현종;이창남;김형섭;김성배
    • 한국강구조학회 논문집
    • /
    • 제23권3호
    • /
    • pp.337-347
    • /
    • 2011
  • 본 논문에서는 콘크리트 채움 U형 강재보와 강재 H단면 기둥으로 구성된 접합부의 내진 성능을 평가하였다. 접합부 내진성능을 평가하기 위하여 세 개의 보-기둥 접합부 실험체를 반복주기하중에 대하여 실험하였다. 합성보는 콘크리트 슬래브와 스터드를 이용하여 일체화 되었으며, 슬래브에는 부모멘트를 위한 철근이 배치되었다. 접합부 상세를 실험 변수로 하였으며, 보 접합부의 강화방안 및 약화방안, 합성효과의 정도를 고려하였다. 합성보의 춤은 슬래브 두께를 포함하여 600mm이며, 강재보와 슬래브의 철근은 H형강 기둥과 용접을 통해 접합하였다. 접합부 강화방안은 합성보 플랜지에 덧댐플레이트를 용접하였으며, 약화방안으로서 소성힌지 발생지점에 채움콘크리트 안에 스티로폼을 삽입하였다. 실험 결과 완전합성 실험체는 강도와 변형능력, 에너지 소산에 있어서 우수한 성능을 보여주었다. 변형능력은 특수모멘트골조 기준인 4% 이상의 회전각을 발휘하였다.

Probabilistic seismic assessment of RC box-girder bridges retrofitted with FRP and steel jacketing

  • Naseri, Ali;Roshan, Alireza Mirzagoltabar;Pahlavan, Hossein;Amiri, Gholamreza Ghodrati
    • Coupled systems mechanics
    • /
    • 제9권4호
    • /
    • pp.359-379
    • /
    • 2020
  • Due to susceptibility of bridges in the past earthquakes, vulnerability assessment and strengthening of bridges has gained a particular significance. The objective of the present study is to employ an analytical method for the development of fragility curves, as well as to investigate the effect of strengthening on the RC box-girder bridges. Since fragility curves are used for pre-and post-earthquake planning, this paper has attempted to adopt the most reliable modeling assumptions in order to increase the reliability. Furthermore, to acknowledge the interaction of soil, abutment and pile, the effect of different strengthening methods, such as using steel jacketing and FRP layers, the effect of increase in the bridge pier diameter, and the effect of vertical component of earthquake on the vulnerability of bridges in this study, a three-span RC box-girder bridge was modeled in 9 different cases. Nonlinear dynamic analyses were carried out on the studied bridges subjected to 100 ground motion records via OpenSEES platform. Therefore, the fragility curves were plotted and compared in the four damage states. The results revealed that once the interaction of soil and abutment and the vertical component of the earthquake are accounted for in the calculations, the median fragility is reduced, implying that the bridge becomes more vulnerable. It was also confirmed that steel jackets and FRP layers are suitable methods for pier strengthening which reduces the vulnerability of the bridge.